Aquavida AQ30 User manual

Contents
I. INTRODUCTION.........................................................................................................................1
II. SAFETY NOTES.........................................................................................................................1
Ⅲ. PRECAUTIONS.........................................................................................................................1
Ⅳ. MAINTENANCE .......................................................................................................................1
Ⅴ.HOW IT WORKS? .....................................................................................................................2
Ⅵ. FEATURES.................................................................................................................................2
Ⅶ. OPERATION ..............................................................................................................................3
1 CONTROL PANEL ............................................................................................................3
1.1 Screen Indication.........................................................................................................4
1.2 Digital Touch Screen indication..................................................................................4
2 INITIAL SETUP.................................................................................................................5
3 OPERATING INSTRUCTION...........................................................................................5
4 CLEANING, STERILIZATION AND REPLACEMENT OF FILTERS............................6
4.1 Cleaning ......................................................................................................................7
4.2.Sterilization .................................................................................................................8
4.3 Replacement................................................................................................................9
5 ATTENTION ....................................................................................................................10
Ⅷ. TROUBLE SHOOTING...........................................................................................................11
Ⅸ. TECHNICAL SPECIFICATIONS............................................................................................12
Note:We reserve the right to at any time without notice make any changes/amendments/deletions and/or variations to the
contents of this manual.

ATMOSPHERIC WATER GENERATOR
I. INTRODUCTION
Thank you for purchasing the Atmospheric Water Generator. The Atmospheric Water Generator is a new,
state-of-the-art water-generating machine, which uses some of the latest and most sophisticated technology
available in the industry today. We have designed your Atmospheric Water Generator with one objective in
mind i.e. to produce the most maximum amount of high quality drinking water while using only minimum
amount of electricity. When hook up with city water or external water bucket supply, the machine can
produce purified drinking water thus makes it a multi-functional machine.
II. SAFETY NOTES
1The socket should be equipped with reliable grounding protection and with a load capacity of 10 Amperes.
2Do not remove ground terminal from the power cord.
3Do not use an extension cord or an extension adapter.
4Always keep the unit from poisonous gas and liquid.
5Do not use damaged electrical plug or power cable.
6Unplug power cord before maintenance.
7Do not share the electrical socket with other high power consumption appliance.
8Replace spare parts with the correct methods.
9Do not unplug power cord with wet hands.
10 Use the enclosed water pipe kits to connect with city water inlet. Do not use any old water pipelines to
connect to the unit.
11 When moving the machine, please unplug the power cord and empty water of all tanks. Do not tilt the
machine more than 20º during moving.
12 Please make sure the person who is not have completed body, sensory or mental disabilities, or lack of
experience and knowledge (Children included) to use the machine under the supervision and guidance of
who is responsible for their safety.
13 Make sure the children do not use the machine.
14 Shipment of the Machine, do not make it over tilted 20°, please make the machine stand horizontally for
30minutes before using it. Because in the process of shipment, the refrigerant could be not go back to the
compressor totally in time, if you start up immediately when arrival, it could cause the compressor to be
damaged.
15 Use the enclosed parts to connect with city water inlet.
Ⅲ. PRECAUTIONS
1Do not place the unit too close to the wall. Best performance is obtained when the unit
is placed at least 30 cm from the wall.
2This unit is not for outdoor use.
3Avoid prolonged exposure to direct sunlight.
4Keep the unit work in standing position.
5Operating voltage must not drop below 10% of standard Power supply. When the unit
operates below this level, the unit becomes noisy with the possibility of overheating.
When this occurs, immediately switch the unit off until the voltage returns to normal.
6Avoid prolonged direct eye exposure to ultraviolet device as it may damage the eye.
7Prevent children playing with HOT knob to avoid scalding.
8This unit is not suitable for use at places with spray water, do not use spray water to
clean the unit.
9To prevent the machine from damage caused by freezing, please drain off the remaining water and stop
operating the machine if the environment temperature during its working is below 0 ℃.
10 If there is any damage to the power cables, the cables must be repaired or replaced by an authorized
person to avoid danger.
11 Please fix the unit with mounting bracket when using this unit.(as
shown in the picture on the right)
12 Do not place any object on top of the machine, there is no obstacle
around the unit. Do not use machinery or any other way to
accelerate the defrosting process, do not damage the refrigerating
circuit. Good ventilation is required to ensure optimum
performance.
Ⅳ. MAINTENANCE
13 Always keep the unit clean. Wipe the outer casing with soft damp fabric to clean. Use water to clean,
1

ATMOSPHERIC WATER GENERATOR
avoid using corrosive cleaning agent.
14 Do not use cleaning agent to clean water tanks.
15 Clean air filter regularly to ensure proper air flow, and check it every week, replace the new one when it
is blocked.
16 If you don’t use the machine for a long time, please unplug it and drain out all the water of top tank and
bottom tank, and clean the water tanks
Ⅴ. HOW IT WORKS?
It is important to be aware that your Atmospheric Water Generator is a humidity and temperature driven machine.
This means the machine totally depends on the level of humidity in the air and the temperature to produce water.
Ideally, the humidity level should be at least 80% or above to achieve the machine’s optimum performance. In
places with lower humidity level, the machine will still produce water but not as quickly, nor as much as in
places with high level of humidity. In the house environment, higher level of humidity tends to be around the
kitchen area, near an open window or in more spacious rooms. This unit also performs well in an air-conditioned
room, but it is recommended to open the window at night to make the room ventilated.
Because your Atmospheric Water Generator works by converting the humidity in the air to water, this unit also
acts as an effective dehumidifier. In areas with high humidity, it not only acts as a good water generator, but also
a perfect dehumidifier to keep you healthy and ensure your home appliances a long service time.
To ensure high quality of drinking water, TheAtmospheric Water Generator is utilizing multiple filtration
technologies, includes the most advanced and secure RO filtration and highly effective UV sterilization
technologies.
When the air is dry or during cold season, water production capacity will be slow. Connect to external water will
make the machine served as excellent water purifier by utilization of the RO filtration, UV sterilization system
and special water recirculation patent technology.
Ⅵ. FEATURES
1Microcomputer
The unit is fitted with a microcomputer, which ensures proper working of internal parts. The machine has preset
hot/cold temperature adjustable functions. Temperature of hot or cold water can preset according to personal
preference.
2Electronic Sensors
Various electronic sensors are attached to parts such as UV light, heating mechanism and water tanks. These
sensors ensure that all parts are working properly and warn you that breakdown or performance irregularities
occur in the machine.
3Energy Saving Features
To conserve electricity, electronic sensors have been placed in the storage tank to automatically stop the machine
from making more water when the tank is full and hot/cold water reaches the preset data.
4Child-proof Hot Water Lock out
The function of hot water lockout is to prevent child from scalding upon touching the water tap.
5Water Leakage Detector
In case of any unexpected situation of water leakage, the machine can stop working automatically and
accompany with warning sound and flashing screen.
6Condensing coils
The condenser is designed especially and with food class coating to prevent any metal pollution and improve
water production efficiency.
7Multi-Stage Filtration System
Our dedication to providing high-quality, great tasting water to our consumers is accomplished by our unique
multi-stage filtration system. It can remove odor and pollutant.
7.1Anti-static / HEPA patented air-filter:
Before air becomes water drop through condensation, the air must go through Anti-static air filter to
2

ATMOSPHERIC WATER GENERATOR
filter out dust particles and effectively block dust in the air from entering the machine.
7.2 LF2 active carbon filter
This device can remove organic compound, dust and large particles in the air. It can also reduce
ammonia level in the water.
7.3 Bottom tank small filter:
Removes large grain impurity in the water of bottom tank, to protect the water booster pump and make it
service life longer.
7.4 Multistage filtration system:
Our filter system not only can produce light alkaline water which is more pure without dirty sewage, but
also produces tasteful purified water with mineral and microelements which bring health to our body.
7.4.1. Pre-Carbon Filter
Remove different color and smell, residual chlorine halohydrocarbon and organic
compounds etc.
7.4.2. Post carbon filter
Further remove any different color, smell, residual chlorine etc., and improve and adjust water
quality.
7.4.3. RO membrane
Mainly remove micro impurity, colloid, heavy metal, soluble solids, bacteria and other harmful
substances.
7.4.4. TCR carbon filter
Mainly provide microelements and minerals which are beneficial to human body health, raise pH
level to light alkaline, improve taste.
The above filtration system for reference only, may change without prior notice.
8Water Recirculation
Our patented exclusive technology ensures that stored water remains fresh and clean and avoids second pollution.
9Overheat Protector
Overheat protector offers further protection for your machine. In case of overheat in hot pot during heating
process, this protector will automatically shut off heating device.
10 Novel and Noble Body
The attractive modern design together with LCD display screen makes the machine easy to operate and more
options to select personal preference.
Ⅶ. OPERATION
By following these simple instructions and simple maintenance procedures, your Water Generator should give
you years of trouble-free operation while producing the most maximum amount of pure, high-quality, drinking
water that is not only healthy, but also beneficial to your health.
Please read this operation manual carefully before you start the machine.
1. CONTROL PANEL
3

ATMOSPHERIC WATER GENERATOR
1.1 Screen Indication
1.1-1. Hot water dispensing indication: When “ ” icon flashes, it means the tap is unlock; Continue light
pressing “ ” icon, “ ” water dropping icon motion flashing means hot water is dispensing.
1.1-2. Bottom tank water level indication: The arrow indicates water level , pointing at 1 means the tank is empty,
number incease as water level rises, 5 means the tank is full.
1.1-3. UV warning indicator: UV light is working well when icon keeps on. If it blinks, UV light
is not functioning.
1.1-4. Water generating indicator: When “ ” icon shows motion, the machine is generating water. When icon
lights on without motion, water generating stops. If the icon blinks, it means the water generating function
has been shut off manually.
1.1-5. Booster bump icon indicator: The bump is working when the icon flashes.
1.1-6. Humidity indicator: Under normal operation, it indicates humidity level. During settings, it indicates
adjusting value.
1.1-7. Top tank water level indicator: The arrow indicates water level , pointing at 1 means the tank is empty,
number incease as water level rises, 5 means the tank is full.
1.1-8. Cold water dispensing indication: Light pressing on the “ ” icon, “ ” water dropping icon motion
flashing means cold water is dispensing.
1.1-9. Cold water temperature indicator: Indicates cold water temperature.
1.1-10. Cooling function indicator: When icon light on means cooling process allows; Icon lights
off means cooling stops; Flashing means cooling in process.
1.1-11. Leak warning icon: “ ” icon light off means normal, light on when leak is detected.
1.1-12. Filter indicator: When “ ” icon light on means normal, flashing means need to
replace filter or clean up is needed.
1.1-13. Recycle indication: “ ” icon flashing means water is recycling.
1.1-14. Deforst icon: “DEFROST” icon flashing means the machine is defrosting.
1.1-15. Water heating icon: When icon light on means heating process allows; Icon lights off
means heating stops; Flashing means heating in process.
1.1-16. UV light icon:
①Top tank U V l i ght i ndi cator : When “ ” icon light on means top tank UV light function
normal, light off means UV light not working; Flashing means top tank UV not functioning normally.
②Reflux UV light indicator : When “ ” icon light on means reflux UV light function
normal, light off means UV light not working; Flashing means reflux UV not function normal
③Bottom tank UV light indicator : When “ ” icon light on means bottom tank UV light
function normal, light off means UV light not working; Flashing means bottom tank UV not functioning
normally.
1.1-17. Hot water temperature indicator: Indicates temperature value.
1.2 Digital Touch Screen indication:
1.2-18. Cold water spout dispense icon : Continuous light pressing the icon will dispense cold water.
1.2-19. Hot water unlock indicator : When hot water is needed, press unlock icon to unlock then keep
pressing unlock icon until hot water dispensing icon “ ” flashing. Then press “ ” to release hot
water.
1.2-20. C/F conversion indicator : To convert centigrade & fahrenheit value. It can control to fill water from
external water bucket; the display window shows “ADD”.
1.2-21. Adjustment icon : Enters function setting, choose function and make adjustments.
1.2-22. Press mode icon “ ” to select function: Selects function needed to be adjust.
4

ATMOSPHERIC WATER GENERATOR
①.W-ON / OFF: Indicates present water generating function on or off, press “ ” to make desire
adjustment.
②.H- ON / OFF: Indicates present heating function on or off, press “ ” to make desire adjustment.
③.C- ON / OFF: Indicates present cooling function on or off, press “ ” to make desire adjustment.
④.H-075 ~ 095: Shows the present hot water temperature, soft press adjustment icon “ ” to set desire
temperature, adjusting range between 75~95 ℃.
⑤.C-004 ~ 010: Shows the present cold water temperature, soft press adjustment icon “ ” to set desire
temperature, adjusting range between 4~10 ℃.
⑥.T-***: Indicates filter system usage time period, soft press adjustment icon “ ” to reset time.
⑦.RESET: Soft press adjustment icon “ ” to reset machine back to original factory setting.
1.2-23. Power control key : Normal operating condition and stand by condition function. When machine
operates normally, continuous soft touching the “Power” key, machine will switch to “stand by” condition.
During stand by condition, soft touch “Power” key and machine will switch back to normal operating
condition.
1.2-24. Hot water spout dispense icon : Continuous soft pressing the “ ” icon until the “ ” icon
flashing , then press “ ” to dispense hot water.
2. INITIAL SETUP
2.1. Please confirm parts in the package are of complete set. The unit should be placed on solid and level ground,
and be located in place with good air circulation. The unit should be placed no less than 30 cm from the wall.
Push down the lever of braking wheel to get the machine in fixed position.
2.2. Do NOT connect it to power within 12 hours, letting the machine in a standing position to make sure the
refrigerant return to compressor. Upon arrival, instant plugging to power may damage the compressor.
2.3. Insert into electrical socket capable of handling no less than 10A.
2.4. If required to connect to city water supply, you may purchase our optional PPF filter cup. Please turn to user
manual “operating procedure”, section 11 and follow the instructions.
3. OPERATING INSTRUCTION
3.1. First time plug in the machine there will be a “beep” sound, the display screen will light on. The compressor
will start working two minutes later, at the same time, the compressor icon will show the machine is
functioning normally. To turn off the machine, keep soft pressing the “ ” key. To restart the machine, keep
soft pressing the same key.
3.2. During the first few hours after the machine start working, with limited amount of water, hot & cold water is
available until the water level rise to a certain point ( under normal condition, the machine takes one full day to
fill up all the tanks, depends on weather condition).
3.3. When the machine has enough water, soft press the “ ” icon, and then press “ ” to select options to
adjust. When heating is on, the “Hot” in red color light will turn on, light turns off when function is off. This
will happen when there is enough water and start heating. It won’t stop until the temperature reached the
pre-set level. When close the heating function In the heating state , the “Hot” in red color will turn off, and the
machine will stop heating in any water level and water temperature condition.
3.4. When the machine has enough water, soft press the “ ” icon and , then press “ ” to select options
to adjust. When heating is on, the “Cool” in red color light will turn on, light turns off when function is off.
This will happen when there is enough water and start cooling. It won’t stop until the temperature below the
pre-set level.When close the cooling function in the cooling state,the “Cool” in red color light will turn off, and
the machine will stop cooling in any water level and water temperature condition..
3.5. Usually, when heating and cooling function is working, the hot & cold water temperature will maintain within
the pre-set temperature range. Temperature can adjust by soft press “ ” then make adjustment on preferred
5

ATMOSPHERIC WATER GENERATOR
temperature level. Hot water range from 75 ℃~95 ℃, cold water range from 4℃~10 ℃。
3.6. The “ ” key locating on the screen is to select Fahrenheit or Celsius indication.
3.7. After the filter system has been use for a period of time, the icon will flash. This is to remind owner to
replace RO membrane or clean up the filters (please refer to filter cleaning and maintenance menu).After
cleaning or replacement finish, soft press “ ” key and re-set number to zero T-000, soft press “ ” again
and the icon will stop flashing. Timer has been re-set.
3.8. When temperature drop to below normal, machine will start defrost, the “Defrost” icon will flash.
3.9. For cool water dispensing, keep pressing on the “ ” key; For hot water dispensing, press “ ” key until
“” icon flashes to unlock spout, then press “ ” to release hot water.
3.10. For energy saving purpose, water level sensors are installed, when water filled to certain level, the machine
will stop generating water.
3.11. Areas with very low humidity and low temperature, the compressor stops working automatically, and the
machine is not produce water anymore, then the machine can hook up external water bucket supply to the
machine. Under extreme weather condition, the machine still can produce tasteful healthy drinking water.
Installation instructions are as follow:
3.12 Brand new machine under first time use needs to follow “Machine cleaning and sterilizing” procedure and
remove odor from machine parts.
4. CLEANING, STERILIZATION AND REPLACEMENT OF FILTERS
6

ATMOSPHERIC WATER GENERATOR
The above structure and filtration system is for reference only.
Recommended Timing for Filter Replacement (It might be verified according to different water consumption. The
timing below is based on 10 liters water consumption per day.):
①Pre-active carbon 3-6 months
②Post-active carbon 3-6 months
③RO membrane 15-24 months
④TCR acti ve carbon 6-9 months
⑤UV lightbulb 12 months or replace when UV warning happens
Attention
:
Different countries or regions may have different environment, the above replacement period is for reference only.
If the machine is continues operation for a long term, filters and UV light tube inside the machine need to be
replaced every once in a while and cold tank,hot tank and bottom tank need to be cleaned and sterilized in order to insure
the machine can produce the most pure drinkable water efficiently.
4.1. Cleaning
4.1.1. Air Filter Cleaning
Please check it every week. When it is blocked, please replace a new one. When replace, please put the white
side outside.(diagram 4.1.1)
Note:
Air filter could not be washed by water, only with air gun or hands to remove dust softly.
In order to a good performance of air purification and water source, please replace the air filter in
time.
4.1.1
Hot/cold Water Drain
Water collector
Standby application
Standby application
Air filter
Bottom tank
Air exhaust
Electric control center
LeakageDetect Device
Standby application
Water
ilt
LCD Screen
Water Tap
Drip Tray
Wheel
Pre carbon
filter
RO Membrane
Pre carbon
filter
Post carbon
filter
TCR Carbon
Filter
7

ATMOSPHERIC WATER GENERATOR
4.1.2. Cleaning of water collector
After machine running for a period of time, clean up the dust that may store up in the water collector.
Please check and clean for every week, and replace every 2-3moths.when cleaning, take out water
collector from the back (diagram 4.1.2) .Clean and replace back to original position.Attention: insert the
water collector along its track until its original position.
4.1.3. Cleaning of bottom tank
①Soft press on the “ ” icon until the machine enter stand by stage (diagram 4.1.3-1), unplug the power cord;
②Take out bottom tank (diagram 4.1.3-2);
③Open tank cover(diagram 4.1.3-3), remove filter cup (diagram4.1.3-4);
④Take out filter net and filter fibre(diagram4.1.3-5), rinse the cup filter with clean water
(diagram4.1.3-6);
⑤Pull out the bottom tank level sensor PIN(diagram4.1.3-7), PIN disconnect UV light
connection pin (diagram4.1.3-8);
⑥D i sconnect thetube of outlet (diagram 4.1.3-9),
⑦Unscrew UV light plastic bolts, (diagram 4.1.3-10); and take out UV light
⑧R emove bottom tank mash fi l ter and ri nse w i th cl ean w ater(diagram 4.1.3-11) and check if the mash small filter
has been broken, replace with new one. Clean the bottom tank with clean cloth.
⑨Install back all the parts and bottom tank once cleaning is finished (diagram 4.1.3-12).
The above cleaning procedure recommend to use city water supply. Install back all part after finish.
4.1.3-1 4.1.3-2 4.1.3-3 4.1.3-4
4.1.3-5 4.1.3-6 4.1.3-7 4.1.3-8
4.1.3-9 4.1.3-10 4.1.3-11 4.1.3-12
4.2. Sterilization
The brand new machine should be sterilized after one week service.
4.2.1. Sterilization solution: Prepare a 15 Liter container and mix 10 liters of clean water with 0.06 liter of
sterilization liquid (30% hydrogen peroxide sterilization liquid),to configure 2% concentration hydrogen peroxide
sterilization solution. Formular:
0.2%=ρ30%hydrogen peroxide×V30%hydrogen peroxide/(ρ30% hydrogen peroxide×V30% hydrogen peroxide+ρwater×Vwater)×100%
Note:ρ=m/V
ρ—density, V—volume, m—quality
4.2.2. Soft touching the “ ” icon until the machine enter stand-by condition (diagram 4.2-1);
Open the top cover (diagram 4.2-2) and then open the top tank cover (diagram 4.2-3); Mix sterilization
solution according to ratio and pour into the top tank (diagram 4.2-4); Check to make sure tank cover
closed properly and tight;
4.1.2
8

ATMOSPHERIC WATER GENERATOR
4.2.3. Soft touch the “ ” icon to turn on machine, touch the “ ” icon, then touch “ ”to unlock then touch
the “ ” icon to dispense about one liter of sterilization solution (diagram 4.2-5, 4.2-6, 4.2-7). Drain off
about 0.5L of the remaining solution from hot water drain outlet at the back (diagram 4.2-8); Keep the
remaining solution soaking in the top tank for more than 2 hours (or as per instruction of the solution);
4.2.4.After the soaking period finished, turn on machine, touch the “ ” icon, and then continue touching
“” icon to unlock then touch the “ ” icon to dispense about 2Lof sterilization solution; Shut down
machine, drain out the rest of the water from the hot water outlet in behind;
4.2.5. Fill city water into bottom tank. Turn on the unit and have it running automatically till top tank is full of
water;
4.2.6. Touch the “ ” icon and then continue touching “ ” icon to unlock then touch the “ ” icon to
dispense about 2L of water; Shut down the unit. Drain off all remaining water from hot water drain outlet at
the back (diagram 4.2-8);
4.2.7. Repeat the above steps in 5 and 6 in order to clean off the remaining solution in top tank. Suggest twice the
same operation.
4.2-1 4.2-2 4.2-3 4.2-4
4.2-5 4.2-6 4.2-7 4.2-8
4.3 Replacement
4.3.1. Replace a filter
Turn off the machine and then unplug the power cable, take off the front lower panel;
②To repl ace the pre-carbon, post-carbon and TCR carbon filters, Pull out and screw out filters, then take out filters
from bottom (diagram 4.3.1-1、4.3.1-2、4.3.1-3); Replace the new filters.
③R epl ace R O membrane: tak e out R O m embrane i nl et w ater tube (di agram 4. 3. 1-4), screw out filter(diagram
4.3.1-5) , take out RO membrane upward(diagram 4.3.1-6);plug back onto the new RO membrane; Put back
lower front panel.
4.3.1-1 4.3.1-2 4.3.1-3
4.3.1-4 4.3.1-5 4.3.1-6
Note:
9

ATMOSPHERIC WATER GENERATOR
Recommend to replace one by one in order.
4.3.2 Replace the top tank UV
After the machine operate for a period of time, the UV light may break. There will be a warning beep sound and
UV icon will flash, the UV light has to be replaced.
①Before repl aci ng, soft touchi ng the“ ” icon until the machine enter stand-by condition
(diagram 4.3.2-1) and unplug power cord;
②Open top cover(diagram 4.3.2-2);
③R emove screw s on top end (diagram 4.3.2-3);
④D i sconnect U V connecti on pi n(diagram 4.3.2-4); Pull out UV bulb (diagram 4.3.2-5); Replace
with new bulb and replace back top cover (diagram 4.3.2-6).
4.3.2-1 4.3.2-2 4.3.2-3
4.3.2-4 4.3.2-5 4.3.2-6
4.3.3 Replace the cool water out UV
①Before replacing, soft touching the “ ” icon until the machine enter stand-by condition
(diagram 4.3.3-1) and unplug power cord.
②Open top cover(diagram 4.3.3-2);
③Remove foam cup of UV (diagram4.3.3-3);
④R emove bl ack i nsul ati on cover(diagram 4.3.3-4);
⑤D i sconnect U V connecti on pin (diagram 4.3.3-5); Pull out UV bulb (diagram 4.3.3-6); Replace with new bulb
and replace back all parts.
4.3.3-1 4.3.3-2 4.3.3-3
4.3.3-4 4.3.3-5 4.3.3-6
5. Attention
5.1. It is recommended to dispense not less than 3 liters of water every day.
5.2. If hot water is not dispensed for a long period, it is recommended to turn on heating process and keep hot
water temperature between 88 ℃
~93℃ for more than 30
“ ” icon until the faucet is unlock, then press “ ” icon, to release 500 ml of hot water from faucet.
10

ATMOSPHERIC WATER GENERATOR
5.3. If the machine was not in use for 2 to 5 days, please drain out 500ml of cool water before dispensing for
drinking use. If the machine is to be inactive for more than 5 days, it is recommended to drain off water in
all tanks and switch off the machine in advance. For its reactivation, please run the system to produce
about 5 liters of water, and drain off from the back drain outlets.
5.4. If the machine was not in use for more than 7 days or it has been in continuous operation for more than 4
months, please follow the steps in CLEANING, STERILIZATION & REPLACEMENT to sterilize the
system.
Switch off the power first before drain out water from the back outlets.Must soft press the “ ” icon
until machine enter stand-by condition, then drain water out from the machine.
Ⅷ.
TROUBLE SHOOTING
Problem One: The UV warning icon “ ” blinks “ ” with three short beeps.
Solution: Check the ultraviolet device in top tank to make sure the bulb is lit and all wirings are correct. If the UV
is not working, replace with new bulb by following steps in REPLACEMENT.
Problem Two: The UV warning icon “ ” blinks “ ” with three short beeps.
Solution: Check the ultraviolet device at cool water outlet to make sure the bulb is lit and all wirings are correct. If
the UV is not working, replace with new bulb by following steps in REPLACEMENT.
Problem Three: The machine does not work even after the power cord is plugged in.
Solution: Check for proper power voltage and ensure that it is in the correct range for operation. Make sure that
the connection to the wall socket is tight and secure.
Problem Four: The indicator on screen display is blinking with beeping.
Solution: After a long period of operation, the filter might be over dirty and will be replaced. Replace with a new
filter by following steps in CLEANING, STERILIZATION & REPLACEMENT. Reset the filtration
warning time by following the 7th step in section OPERATIONAL STAGE.
Problem Five: The system detected water leakage on base. The red logo on screen blinks and the system
cannot produce water.
Solutions:
①Immediately touch the “ ” icon until the machine enter stand-by condition, unplug power cord from
electrical outlet.
②Check all tubing of filtration system is tight and secure.
③Check the tubing of bottom tank is tight and secure.
④Check the draining tubing at the back is tight and secure.
⑤Check the water collector is on correct position.
After problem is solved, remove lower panel at the back of the machine, locate leak detecting device (diagram 5-1),
take out the silicon cup and clean out water inside (diagram 5-2, 5-3), put the cup back on (diagram 5-4) then turn
on machine.
5-1 5-2 5-3 5-4
Problem Six:Remaining water cannot be drained out from the back outlets when cleaning top tank and hot
tank.
Solutions: Check water stopper inside water drain outlet is removed.
Problem Seven:There is burning smell from the machine and meanwhile hot temperature
indication has exceeded the preset.
Solutions:
11

ATMOSPHERIC WATER GENERATOR
①Immediately touch the “ ” icon until the machine enter stand-by condition, unplug power cord from
electrical outlet.
②Stop draining immediately if you are on draining operation from the back. Wait and continue draining until
hot temperature is normal.
③Check if the top tank cover is open, if so, press tight the top tank cover immediately.
Problem Eight:Water output from faucet is too small.
Solutions:
①Clean the filter net inside water faucet or replace with new one.
②Unscrew water tap, adjust and install the nano flter net and silicon sealing ring inside in place ,screw water
tap back to its original position.
Problem Nine: No hot or cool water output but with ambient water only.
Solutions:
①The heating function will be activated only when top tank water level on screen is above two levels.
②The cooling function will be activated only when top tank water level on screen is above three levels.
Problem Ten: The machine makes water at a slow rate even after prolonged period of
operation.
Solutions:
①Make sure the temperature level is in appropriate range.
②Check the humidity level in the room. Low humidity level results in less water production.
③Make sure that the hot/cold water spouts are not blocked.
④Make sure that the ingoing and outgoing air ventilation is not blocked.
⑤Check that the distance between the machine and the wall is not too close.
⑥Make sure that the power voltage is not too low or too high.
⑦Make sure that the internal booster pump is working well.
⑧Make sure that the water lines are not blocked and water flow is smooth.
⑨Make sure that the unit is placed in good ventilation condition, and the air filter net is cleaned regularly to
ensure the free air flow.
Problem Eleven: The humidity indication on screen is different from the real room humidity
level.
Solutions:
①It is normal if the difference is in range of 5% more or less.
②Make sure the machine and the individual humistat are placed in same place.
③Make sure that the humistat sensor is not blocked, covered or too close to the wall.
Problem Twelve: The machine is with excessive vibration or noise.
Solutions:
①Make sure there is no object placed on top of the machine.
②Make sure that there is no water cup placed on water tray.
③Open the front bottom panel and check if the copper tube at the side is touching the side panel. Correct the
position of copper tube slightly and slowly if there is.
Once all the above procedures have been performed and your machine still does not work or does not work
correctly, please do not try to perform other repair procedures yourself. Always call a qualified service technician
to look at the machine and perform the repair procedures. We are not responsible for any damages incurred during
self-reparation and void all warranty.
Ⅸ. TECHNICAL SPECIFICATIONS
①Dimensions
Height: 112cm
Width: 45cm
Depth: 43cm
12

ATMOSPHERIC WATER GENERATOR
Net Weight: 49kg
②Power
Voltage:220W/50Hz
Power input:830W
Heating Wattage:500W
Compressor Power:300W
③
Coefficient of Water Quality
Working Temperature:15 ℃-40 ℃Temperature of Hot Water:75 ℃-95 ℃
Working Humidity:35%-95% Temperature of Cold Water:4 ℃-10 ℃
Water Storage Capacity:12.5 Liters
Atmospheric Water Production Capacity
:
Water Generating (24hours)(Liters)
Temperature Range:15-40
Humidity(%)35 40 50 60 70 80 90
Capacity(liter)10 14 18.5 22 25 28 30
30
40
50
60
70
80
90
0
10
15
20
30
25
Water generating volume
(Liters)
13
Table of contents
Popular Water Dispenser manuals by other brands

Hydrotec
Hydrotec HYDROWELL Compact E Series Operating and maintenance manual

Magic mill
Magic mill MUR25 owner's manual

US Water Systems
US Water Systems Pulsar Bodyguard 390-PWFMS1-A owner's manual

Elkay
Elkay Space-ette FHD70052EJO Series Installation, care & use manual

Culligan
Culligan Super S Installation and operating insctructions

Oasis
Oasis B1RRK Instruction guide

Griesbach
Griesbach Diamond H2O LINQ DLS-30-100 product manual

A.O. Smith
A.O. Smith AO-WH-DSCLR owner's manual

Aqua Cooler
Aqua Cooler Maximus Series use and care manual

Evo-water
Evo-water soft monomatik Installation & operating guide

Hellenbrand
Hellenbrand ProMate-6 user manual

AquA NanO
AquA NanO LIFEFILTA Operation