ARC ALMDT-1407 User manual

Version 1.
Overview :
Preparation :
1. Remove the back holder by pushing holder down then pull it away. ( Fig 1 )
2. Remove of battery cover. ( Fig 2 )
3. Insert battery, pay attention on battery polarity + / – while inset battery. (Fig 3 )
4. Secure the battery cover back. ( Fig 4 )
5. Using a small tool to short press “ Set “ button to test function ( Fig 5 ) , LED inside of detect window
will be quickly blinking ( Fig 6 ). Then short press “ Set ” button again to stop LED blinking.
Fig1 Fig2 Fig3
Fig4 Fig5 Fig6
LED
Motion Detector
ALMDT-1407

Version 1.
Pairing :
Pair Motion Detector (ALMDT) with Siren
1. Press and hold Siren’s “ Learn ” button about 3 seconds till LED is slowly blinking to confirm enter
Learn mode. Lean mode will be lasting 12 seconds then exit automatically.
2. Using a small tool to press and hold “ Set ” button than 3 seconds while Siren is in Learn mode to pair
with Siren. Both ALMDT LED and Siren’s will be quick blinking 5 times to confirm paired successfully.
Enter Learn Mode Press and hold Set for 3 seconds
Test function of Motion Detector (ALMDT) with Siren,
Enter Test mode and test with follow steps.
1 : Short press ALMDT “ Set “ button one time,ALMDT LED will be slowly blinking.
2 : Wait for 25 seconds
3 : To turn Lens of ALMDT to toward movement ( for example: to face user ) Siren
will be flashing two times accompany two alert sounds.
4 : Move Lens away from movement then to turn Lens to face movement again Siren will be
flashing two times accompany two alert sounds again to confirm function is working
Short press “ Set “ again to exit test mode immediately. Test mode will be exit automatically
1 minutes later without pressing “ Set “.
Wait for 25 seconds

Version 1.
Un-pairing Motion Detector (ALMDT ) from Siren
1. Press and hold Siren “Learn “button about 3 seconds till LED is slowly blinking to confirm enter Learn
mode, Learn mode will be lasting 12 seconds then exit automatically.
2. Press and hold ALMDT “DEL” button about 3 seconds while Siren in Learn mode to un-pair ALMDT
from Siren. Both Siren and ALMDT LED will be quick blinking 5 times to confirm successfully
un-pairing.
Enter Learn Mode Press and Hold DELfor 3 seconds
Delete ALMDT’s all Pairings
Pressandhold“Del”buttonmorethan3secondstillLEDisslowlyblinkingtoenter“Delete”mode.
Releasethepressing,thenpress“Del”buttonagainformorethan6secondstillLEDquickblinking,
Releasethepressing,thenshortpress“Del”buttonagaintodeleteallpairs,LEDwillblinking5times
toconfirmhasdeletedallpairs.
Enter Delete Mode Release Press & hold 6 seconds Release Short Press
Important Notice:
Siren’s all parings must be deleted at the same time once ALMDT all pairings be deleted. Please refer
to delete Siren all pairings procedure to delete Siren all pairings after ALMDT all pairings be deleted.

Version 1.
Installation .
Pay attention to the following steps during installation.
1. Choose a suitable installation location for detector then to install back holder first. It is recommended to
mount it at the height of 2.2-2.5 m from the ground and close to entry or exit. ( Fig 7 ) ( Fig 8 )
Fig7 Fig8
Fig9 Fig10
2. Avoid the detector facing glass windows or door.
Strong light interferes with detection sensitivity. (Fig 9)
3. Avoid the detector facing to or positioning close to
heat source may cause false detection . (Fig 10)
4. Place the ALMDT to the back holder.
Please pay attention on four back side slots of holder (Fig 4-1) need to be pushed and
be inserted to the correspondent hook of back holder first (Fig 4-2) then press PIR down ( Fig 4-3 ).
Fig4-1 Fig4-2 Fig4-3

Version 1.
Operation :
Arm :
Press and hold ALKCT “Arm” button more than 1 second to enable siren enter Arm mode. ALCKT red LED
will Lights ON for 1.5 second to confirm in Arm mode. ALCKT LED will be quick blinking for three times
if fail to
enter Arm mode. Repeat pressing ALKCT Arm button to ensure Siren to enterArm mode. Siren will be ready
for operation 75 seconds later after Siren entering into Arm mode. +25 sec.
Disarm:
Press and hold ALKCT Disarm button more than 1 second to disable siren arm mode, ALCKT red will lights
ON for 1.5 second to confirm exist arm mode. ALCKT LED will be quick blinking for three times if fail to
exit Arm mode. Repeat pressing ALKCT “Disarm” button to ensure Siren exist Arm mode.
Arm Disarm
Active and Inactive Siren.
1. Set Siren to enter Arm mode and wait for 75 seconds
2. If Motion Detector sense movement will trigger Siren to active alert alarm sound, the alert alarm sound
will be lasting for 4 minutes. To stop alert alarm sound press “ Disarm “ button .
Self-Diagnosis time.
The Motion Detector needs about 4 to 6 seconds self reset time between each detection. Once ALMDT has
performed detection will not again perform detection before finishing self-reset.

Version 1.
Low Battery.
LED will be blinking 3 times every 6 seconds to indicator battery is low battery. LED will be blinking
for about 7 days. However, it is recommended to replace with new battery immediately.
Technical Specification.
Motion Detector ( PIR ) item number : ALMDT-1407
Frequency : 868.3 MHz FSK two ways communication
Detection : Detect changed in movement by infrared technology
RF Communication distance : Min. 120M (Straight line open area)
Operation Voltage : 2 pcs AA 1.5V Alkaline battery
Battery Life : Min. 18 months
Battery low indicator : LED indicator
Detection angle : Horizontal Max. 120 degree, Vertical 62 degree
Detection range : 10m
Dimension : 112 x 65.5 x 52 mm ( LxWxH)
Table of contents