manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Archer
  6. •
  7. Controllers
  8. •
  9. Archer SR9 Owner's manual

Archer SR9 Owner's manual

Archer Instruments, LLC www.archerinstruments.com
Model SR9 Automatic Switchover
Installation, Operation & Maintenance
General: The Archer Instruments Model SR9 Automatic Switchover vacuum regulator
is designed for use in pairs, with one unit connected to an on-line gas cylinder / gas
source and the other connected to a standby cylinder / gas source. The SR9 can also be
used in the same way with multiple units connected to multiple standby gas sources.
Safety: When working with chlorine, always use caution and follow applicable safety
procedures. General safety considerations:
* Store Chlorine separately from Ammonia.
* When using chlorine, avoid locations that expose the cylinder and equipment to direct
sunlight.
* Do not apply heater or heat source directly to chlorine cylinders.
* 150lb (upright) cylinders: Always keep cylinders upright and ensure the steel valve
cap is in place when moving cylinders. Once cylinder is in place, a safety chain should be
used to secure the cylinder.
* Ton Containers: Use appropriate handling equipment when moving ton containers.
When readying ton container for use, ensure valves are aligned vertically. The top valve
accesses gaseous chlorine and the bottom valve accesses liquid chlorine. The bottom
valve should never be touched unless your system employs a chlorine heat exchanger
(evaporator) designed expressly for use with liquid chlorine. When drawing gas from ton
containers an appropriate ton container adapter & drip leg must be used (also available
from Archer Instruments).
Archer Instruments, LLC www.archerinstruments.com
Installing the Model SR9:
1) Carefully inspect the cylinder valve outlet surfaces and vacuum regulator inlet capsule
surfaces for damage or debris prior to installation.
2) Note that the inlet port on the SR9 regulator ships with a filter cartridge installed. Do
not remove this filter, as doing so will bring on maintenance requirements.
3) Always use a new lead gasket when connecting the vacuum regulator to a chlorine
cylinder valve.
4) Holding the SR9 vacuum regulator upright, settle it over the cylinder valve and fit the
inlet capsule into the cylinder valve outlet port.
5) Using a 3/8” wrench, tighten the yoke assembly “half-dog” set screw so that the lead
gasket is crushed between the valve and the inlet capsule.
6) Connect the vent and vacuum tubing to the SR9 regulator (these are labeled).
Vacuum tubing should be connected to a tee fitting, which connects the two vacuum
regulators and the remote meter panel. See figure below:
NOTE: Vent tubing should always be connected and run to a safe location (outside of
any building). A vent bug cap (provided with every Archer Instruments vacuum
regulator) should be fitted over the end of vent tubing to prevent insects from entering
the equipment.
Archer Instruments, LLC www.archerinstruments.com
Operating the Model SR9:
1) Prior to placing the SR9 vacuum regulator into operation, it is important to carefully
test the lead gasket seal. A small squeeze bottle (provided with every Archer
Instruments vacuum regulator) should be partially filled with ammonia. Squeezing the
bottle allows the ammonia fumes to be used to test for chlorine leaks. A leak is detected
by a visible light gray / white gas cloud when the two fumes interact. To test for leaks,
open the cylinder valve ¼ turn and then close immediately. This pressurizes the lead
gasket seal but ensures the full cylinder of chlorine is isolated during leak testing. Use
ammonia fumes around the cylinder valve and lead gasket to check for any signs of
leaking gas. If a leak is found, this must be addressed before placing the unit into
operation.
2) After confirming no leaks exist, open the chlorine cylinder valve 1/3 of a turn. This is
fully open and there is no need to open the valve further.
3) If the Model SR9 being placed into operation is meant to be the on-line unit (cylinder
being used first), no further action is needed.
4) If the SR9 being placed into operation is meant to be the standby unit, turn the reset
knob 2 to 2-1/4 turns counter clockwise to engage the automatic switchover detent.
Then immediately turn the knob clockwise until it rests flush against the body of the SR9
regulator.
5) The indicator screw should protrude as shown on the label, indicating the unit is in
standby. The regulator will now not allow gas to be fed until the on-line gas source is
depleted, at which time it will automatically switch into operation.
Maintaining the SR9:
Recommended Maintenance Frequency: Archer Instruments recommends yearly routine
maintenance of the SR9 vacuum regulator.
-Refer to the following parts diagram when performing maintenance on the SR9.
*IMPORTANT NOTE:
The VRA-511 reset screw and the VRA-546 reset pin have LEFT HANDED THREADS.
The VRA-546 reset pin also has left-handed threads where it is connected to the VRA-
547 diaphragm back plate.
1) To disassemble the SR9, first make sure the unit is in the feed position (not in
standby).
2) Next unscrew the VRA-511 reset screw (clockwise to unscrew). Then remove the
VRA-541 reset knob.
3) Remove the two BTA-125 yoke screws and pull the yoke & inlet assembly out of
the back of the vacuum regulator.
Archer Instruments, LLC www.archerinstruments.com
4) Remove the BTA-124 and BTA-129 body screws and separate the SR9 front and
back bodies. The diaphragm assembly can then be removed.
5) The reset pin VRA-546 can be unscrewed if necessary (left-hand threads) from
the diaphragm assembly using a pair of pliers, being careful to only grab the
smooth part of the pin. This part has a raised ring, which must not be marred.
6) The diaphragm back plate VRA-547 and diaphragm front plate are threaded
together using standard right-hand thread and can often be unscrewed by hand. If
they will not unscrew, it may be necessary to use a vice and / or channel locks.
7) The vent (relief) valve assembly can be unscrewed from the back body for service.
8) Whenever routine maintenance is being performed, all parts should be thoroughly
cleaned. It is recommended that all o-rings be replaced. Replacing the VRA-546
reset pin is only necessary if the SR9 will not remain in the standby position. This
part has left-hand threads and must be fully screwed in until it bottoms out.
9) When reassembling, new o-rings should be given a thin film of the Fluorolube
grease.
10) The inlet assembly is a critical component of the SR9 and improper handling
or reassembly can result in dangerous leakage of chlorine gas. Archer
Instruments recommends only trained personnel or those familiar with
vacuum regulator maintenance service the inlet assembly. To service the
inlet assembly:
a. Remove the inlet assembly from the yoke plate by sliding the VRA-142
retainer clip off of the inlet capsule.
b. Remove the inlet filter from the inlet capsule. The inlet filter cartridge (FCA-1
& FCA-2 used for 250 PPD and below) can be removed using the tool
provided of by any ¼-20 threaded bolt or screw. The SR9 body screws and
yoke screws are also ¼-20 thread. Unscrew the FCA-2 from the FCA-1 and
replace the filter. For 500 PPD, a silver screen & filter floss are used.
c. The inlet assembly can now be disassembled by using a small flathead
screwdriver to unscrew the inlet valve (VRA-112) from the vent plug (VRA-
111). Be careful when disassembling as the inlet assembly is under spring
tension and small parts could be lost.
d. Once the inlet valve, vent plug, spring, spring holder and spring retainer are
removed, the seal plug (VRA-182) and inlet capsule (VRA-141) can be
unscrewed.
e. The inlet valve seat (VRA-110) can be removed by pressing it up and
through the inlet capsule. The inlet valve seat is a maintenance part and
once removed should never be reused.
f. Carefully clean the inlet capsule, seal plug, inlet valve stem, vent plug,
spring holder, spring retainer and spring. NOTE: The VRA-112 inlet valve
stem must be cleaned using a non-abrasive cloth (or Scotch-Brite pad).
g. Using a new inlet valve seat and new o-rings (with a thin film of the grease
provided on each o-ring), reassemble the inlet assembly in reverse order.
-Should you have any questions during maintenance of your SR9 vacuum regulator,
please contact your local service provider or Archer Instruments for support.
Archer Instruments, LLC www.archerinstruments.com
Item# Qty. Part # Description
Item# Qty. Part # Description
1 1 BTA-511 #10-24 x 2” reset screw
19 1 OA-VIT-112 O-Ring
2 1 RSW-9 Reset Screw Washer
20 1 VRA-141 Inlet Capsule
3 1 VRA-541 Reset Knob
21 1 VRA-111 Vent Plug
4 1 VRA-546 Reset Pin
22 1 VRA-5010 Filter Membrane (100PPD)
1 VRA-102 Silver Screen (250 PPD)
1 VRA-455 Filter Floss (250 PPD)
5 1 VRA-545 Reset Collar
23 1 FCA-1 Filter Cartridge Base
6 1 VRA-555 Front Body
24 1 FCA-2 Filter Cartridge Body
7 1 VRA-269 Diaphragm Front Plate
25 1 VRA-112 Inlet Valve Stem
8 2 DIA-106 SR9 Diaphragm
26 2 OA-VIT-011 O-Ring
9 1 OA-CEM-207 O-Ring
27 1 VRA-110 Inlet Valve Seat
10 1 TCA-64 Vent Tube Connector
28 1 SPA-104 Inlet Spring
11 1 VRA-521 Vent Seat
29 1 VRA-113 Inlet Spring Holder
12 1 VRA-522 Vent Cap
30 1 BTA-123 ¼-20 x 1-1/2” Screw
13 5 BTA-129 ¼-20 x 2-1/4” Screw
31 1
OA-VIT-331
O-Ring
14 1 SPA-520 Spring (vent)
32 1 VRA-556-XXX Back Body
250 / 500 250 PPD / 500 PPD
15 1 OA-VIT-212 O-Ring
33 1 VRA-547 Diaphragm Back Plate
16 1 VRA-182 Seal Plug
34 1 VRA-183 Spring Retainer
17 1 VRA-346 Yoke Assembly
35 1 OA-VIT-126 O-Ring
18 1 VRA-142 Retainer Clip
Not Shown-2 BTA-125 ¼-20 x 2-3/4” Yoke Screw
Notes: Vacuum Tube Connector (not shown) supplied as
follows: 3/8” tubing for 100 PPD & below, ½” tubing for 250
PPD and 5/8” tubing for 500 PPD. Tap size is ¼” NPT for 100
PPD & 250 PPD / ½” NPT for 500 PPD.
Date: Nov 2016
Drawing Number: SR9
Archer Instruments, LLC www.archerinstruments.com
Item# Qty. Part # Description
Item# Qty. Part # Description
1 1 BTA-511 #10-24 x 2” reset screw
19 1 OA-VIT-112 O-Ring
2 1 RSW-9 Reset Screw Washer
20 1 VRA-141 Inlet Capsule
3 1 VRA-541 Reset Knob
21 1 VRA-111 Vent Plug
4 1 VRA-546 Reset Pin
22 1 VRA-101 Inlet Screen
5 1 VRA-545 Reset Collar
23 1 VRA-455 Filter Floss
6 1 VRA-555 Front Body
24 1 LGA-100 Lead Gasket
7 1 VRA-269 Diaphragm Front Plate
25 1 VRA-184 Filter Stop
8 2 DIA-106 SR9 Diaphragm
26 1 VRA-112 Inlet Valve Stem
9 1 OA-CEM-207 O-Ring
27 1 VRA-110 Inlet Valve Seat
10 1 TCA-64 Vent Tube Connector
28 1 SPA-104 Inlet Spring
11 1 VRA-521 Vent Seat
29 1 VRA-113 Inlet Spring Holder
12 1 VRA-522 Vent Cap
30 1 BTA-123 ¼-20 x 1-1/2” Screw
13 5 BTA-129 ¼-20 x 2-1/4” Screw
31 1
OA-VIT-331
O-Ring
14 1 SPA-520 Spring (vent)
32 1 VRA-556-500 Back Body 500 PPD
15 1 OA-VIT-212 O-Ring
33 1 VRA-547 Diaphragm Back Plate
16 1 VRA-182 Seal Plug
34 1 VRA-183 Spring Retainer
17 1 VRA-346 Yoke Assembly
35 1 OA-VIT-126 O-Ring
18 1 VRA-142 Retainer Clip
36 1 OA-VIT-011 O-Ring
Notes: Vacuum Tube Connector (not shown) supplied as
follows: 5/8” tubing for 500 PPD. Tap size is ½” NPT for 500
PPD. Vent tube connector for 3/8” tubing.
Not Shown-2 BTA-125 ¼-20 x 2-3/4” Yoke Screw
Date: July 2014
Drawing Number: SR9-500

Other Archer Controllers manuals

Archer VR2K Owner's manual

Archer

Archer VR2K Owner's manual

Archer VR3 Owner's manual

Archer

Archer VR3 Owner's manual

Archer VR6 Owner's manual

Archer

Archer VR6 Owner's manual

Popular Controllers manuals by other brands

VTsistema RV 2 Series Original user manual

VTsistema

VTsistema RV 2 Series Original user manual

Evco EVF815 Installer manual

Evco

Evco EVF815 Installer manual

LINK-MI LM-TV03-4K2K user manual

LINK-MI

LINK-MI LM-TV03-4K2K user manual

Emerson TARTARINI FL Series instruction manual

Emerson

Emerson TARTARINI FL Series instruction manual

CAME ZT6 manual

CAME

CAME ZT6 manual

Epever SolarV AN Series user manual

Epever

Epever SolarV AN Series user manual

INSTROTECH 4004 operating manual

INSTROTECH

INSTROTECH 4004 operating manual

BEA MS41 manual

BEA

BEA MS41 manual

Tunze RO Water Controller 8555 Instructions for use

Tunze

Tunze RO Water Controller 8555 Instructions for use

Mitsubishi MELSEC-F FX-TRN-BEG-E user manual

Mitsubishi

Mitsubishi MELSEC-F FX-TRN-BEG-E user manual

3M Touch Screen Controller RX181 reference guide

3M

3M Touch Screen Controller RX181 reference guide

NOVAK KINETIC 1S manual

NOVAK

NOVAK KINETIC 1S manual

Vacon CANopen OPTE6 user manual

Vacon

Vacon CANopen OPTE6 user manual

JFY tech SCM48100 user manual

JFY tech

JFY tech SCM48100 user manual

GE 37 Series instruction manual

GE

GE 37 Series instruction manual

ROBBE RO-CONTROL PRO WIFI 200A OPTO user manual

ROBBE

ROBBE RO-CONTROL PRO WIFI 200A OPTO user manual

Cisco AIR-WLC4402-50-K9 Installation and configuration guide

Cisco

Cisco AIR-WLC4402-50-K9 Installation and configuration guide

GSI Electronics 890-00664 installation instructions

GSI Electronics

GSI Electronics 890-00664 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.