Argo-Hytos EL6 User manual

1
Functional Description
HA 9150
04/2014
Electronics for Proportional Valve Control EL6
qMicrocontroller design
qIndependent adjustments (Incl. ramp up and ramp down)
q3 digit extra bright seven segment LED display
qLarge, easy-to-use adjustments and readout
qDisplay and adjust actual values (current & voltage)
qWide range of supply voltage
qUser selectable input type through menu setup (ex: 0 to 5V,
0 to 10 V, 4 to 20 mA)
qWide ramp time range (0 to 99,5 sec)
qSimple control with analog input, locally supplied reference
voltage
qEnergy efficient PWM circuit, no heat sink required
qElectronic limiting circuit/ short circuit proof
qReverse polarity, command input protection
qLoad can be connected and disconnected live
The control electronics is intended for controlling of
proportional valves with one control solenoid. Its great
advantage is a miniature design in form of a socket for a
standardized DIN connector base. On the electronic
card’s top surface, two revolving selectors, a terminal
block for connecting of supply and control wires, and
three-position LED display are attached. The selector
marked as “SELECT” serves for selecting of parameters
for setting up. The second selector, marked as
“ADJUST”, serves for setting up of a desired value. In a
basic mode, the display shows an input/output
parameter value; conversely, in a setting mode, a
selected parameter abbreviation and the value being set
up are indicated. Setting up of an input control signal
selected type .
Technical Data
Operating Voltage V DC 9 - 36
Maximum output current A 3,00
Input signal 0 - 5 [V] 0 - 10 [V] 4 - 20 [mA]
Maximum ramp time s 99,5
PWM / Dither frequency Hz 40 - 450
Linearity % 1
Operating Temperature °C - 40 ... 75
Recommended cross-section of lead-in wires mm20,5 ... 0,75
Protection Grade IP 65
Attention:
A cable with a circular cross-section and outside diameter of 4 to 6mm should be used for the electronics supply, only
this way the declared degree of IP protection can be secured.
Replaces
HA 9150 08/2013

9-36 V
9-36 V
0-10V
0 V
+5 V
9-36 V
9-36 V
4-20 mA
9-36 V
4-20 mA
REF IN +VDC GND
2
1
3
IN
+VDC
GND
2
1
3
2
HA 9150
Schematics
1) EXTERNAL INPUT SIGNAL CONNECTION
”in” set to ”10”)
2) POTENTIOMETER CONNECTION
(” in” set to ”5”)
3) RAMP UP & DOWN ONLY OPERATION
(” in” set to ”5”)
4) EXTERNAL INPUT SIGNAL CONNECTION 4-20 mA
(” in” set to ”420”)
4) TWO WIRE TRANSMITTER INPUT CONNECTION 4-20 mA
(” in” set to ”420”)
Power supply
Fuse
Analogue
output
Power supply
Command
signal
Potentiometer
10kW
Analogue
output
Command signal
Command signal
Command signal
Power supply
Power supply
Power supply Analogue
output
Command signal

3
HA 9150
Set-up Procedure
1. At power up, the display will show either the output current signal or the input signal (Default display setting shows the
output signal). The decimal point will be flashing.
2. Rotate „SELECT“ to enter the set-up mode. Parameter abbreviation is indicated on the display
3. When you reach the setting you want to modify, rotate „ADJUST“ up or down to the desired value.
4. To modify another setting, rotate „SELECT“again and repeat..
5. The Driver is fully functional during the set-up procedure with any adjustments effective immediately.
6. In order to write the new settings in the memory and return to normal mode of operation, rotate „SELECT“ until the
display shows „SR“ and then rotate „ADJUST“ from 0 to 1 or wait for 100 seconds.
7. If you do not want to save the new settings you have just modified, you must disconnect the Driver form the power
supply before the end of the 100 seconds to restore precious settings.
8. After saving parameters to memory, the decimal point will be flashing and the Driver display will be back showing either
the output current signal or input signal depending on your „di“ selection.
9. To start over completely, you can restore the factory settings by rotating „SELECT“ to „rFP“ and then rotate „ADJUST“
up from 0 to 10 for the display to reset. (NOTE for Step 9: You may have to adjust your Input Signal Setting again if you
reset to factory settings.)
Attention:
Prior to setting up parameters, you must select proper Input Signal setting for your system.
Voltage signal from 0 to 10 V is standardly preset.
Applying improper Input Signal to wrong setting on the Driver may be damaging to Driver Unit and may
cause driver to fault to „Error“ Status mode .
Table settings
Parameter
Abbreviation Parameter Adjustable
Range
Hi HIGH, Maximum Current Output 0,20 – 3,00 A
Lo LOW, Minimum Current Output 0,00 – 2,99 A
rUP RAMP UP, Time for Output to Increase from min to max 0,0 – 99,5 s
rdn RAMP DOWN, Time for Output to decrease from max to min 0,0 – 99,5 s
Cdb
area of insensibility – an output current for a coil is zero, until a control signal will exceed a
threshold of insensibility (the threshold is expressed in % of the control signal maximum
value)
0 – 5 %
dFr DITHER FREQUENCY, 40 (40Hz) to 450 (450Hz) 40 – 450 Hz
in
5
10
420
Input control signal type selection
- Voltage signal
- Voltage signal
- Current signal
0 – 5 V
0 – 10 V
4 – 20 mA
di
0
I
Signal value indication for checking or problem solving purposes
- Command signal [V] or[mA]
- Output signal [A]
Flashing decimal point is an indicator for present display mode*:
- Fast Flashing decimal point, several flashes per second indicates –
Command signal (di = 0)
- Slow Flashing decimal point, 1 per second indicates) – Output signal (di = I)
- No Flashing decimal point or No decimal point indicates display in SETTING/ADJUST
SR SAVE SETTINGS
rFP RESET FACTORY PARAMETERS
Err
0
1
2
ERROR DETECTION STATE, Short Circuit, Reverse polarity protection and detection
- Error 0 - No Errors
- Error 1 - Overcurrent in driver likely due to short circuit in Solenoid
- Error 2 - Current exceeding 20 mA in „4 to 20mA“ input mode
CLr CLEAR ERROR, Clears Driver of Error State
NOTE: When adjusting the HI and LO parameters, note the HI parameter value cannot be adjusted below the LO
parameter value as well the LO parameter value cannot exceed the HI parameter value.

4
HA 9150
0% 3% 5% 25%
1,00
2,00
3,00
0,00
100 Hz 200 Hz
0 50 100
0.00
1.00
2.00
3.00
0
0.00
1.00
2.00
3.00
0510
500
0
0 V
4 mA
3.00
2.00
1.00
5 or 10 V
20 mA
3.00
0.00
0 V
4 mA
2.00
1.00
5 or 10 V
20 mA
3.00
0.00
5 10
Adjustment of Maximum:
(High) / parameter „Hi“
Maximum Current output 0,20 až 3,00 A
Time[s] Time [s]
Command signal [V or mA]
Solenoid current [A]
Adjustment Ramp
(Ramp up) / parameter „rUP“
Time for Output to Increase from min to max, 0 až 99,5 s
Adjustment Ramp
(Ramp down) / parameter „rdn“
Time for Output to Decrease from max to min 0až 99,5 s
Adjustment (Command deadband) / parameter „Cdb“
Output disabled if command signal less than deadband
0až 5% of the maximum Command signal
DITHER FREQUENCY / parameter „dFr“
Frequency settable in a range of 40 až 450 Hz
Command signal [V or mA] Time [ms]
Command signal [V or mA]
Solenoid current [A]
Solenoid current [A]
Solenoid current [A]
Solenoid current [A]
Solenoid current [A]
Range Adjustment
Adjustment of minimum
(Low) / parameter „Lo“
Maximum Current output 0,00 až 2,99 A

5
HA 9150
20(0.79) M3
40 (1.57)
32(1.24)
109 (4.31)
52(2.03)
5(0.20)
18 0.71)
18(0.71)
Dimensions Dimensions in milimetres (inches)
A
DETAIL A
M 2:1
312

6
Caution!
The packing foil is recyclable.
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of the law.
Subject to alteration without
ARGO-HYTOS s.r.o. CZ - 543 15 Vrchlabí
Tel.: +420-499-403 111
E-mail: [email protected]
www.argo-hytos.com
Table of contents
Popular Controllers manuals by other brands

URC
URC MRX-4IR owner's manual

SAJ
SAJ 8000m Series user manual

EUCHNER
EUCHNER CES-AR-AES-12 operating instructions

hpmont
hpmont HD3L Series user manual

National Instruments
National Instruments FieldPoint cFP-20 Series quick start guide

Automatic Heating
Automatic Heating Modulex E8 Operation & User’s Guide