104804 Issue B
ECN: 04179
INSTALLATION INSTRUCTION
PRODUCT DIMENSIONS
ARISTON CANOPY
Model RHE9IX, RHE6IX
All Dimensions are in mm
225
597 (600mm Model)
897 (900mm Model)
215-235
Min 585
Max 885
500
170
CANOPY OPERATION
the control panel.
PLEASE READ THE ENTIRE INSTRUCTION BEFORE INSTALLING THE CANOPY
Particular care must be taken with grease filters which must be periodically cleaned
(at least every two months). Remove the grease filters and wash them either by
hand or in the dishwasher using mild detergent. CAUTION: Never use products
containing abrasives (e.g. scouring pads, steel wipes, abrasive liquid cleaner etc.)
Use lukewarm water and mild detergent to clean stainless steel components. In high
humidity and coastal environments, cleaning should be carried out frequently.
Thank you for purchasing a quality stainless steel canopy rangehood. We have a
high standard of quality control and each rangehood is tested and approved before
it leaves the factory.
IMPORTANT: Please read prior to installation or operation
•
Always switch power off prior to installing, servicing or cleaning the appliance.
•
Never use the appliance without filters.
• Please read the notes on general cleaning, especially the filters.
• Exhaust air must not be discharged into a heating flue or wall cavity, unless the
cavity is designed for that purpose.
• Areas where the rangehood is installed that also have gas, oil or coal fired
heaters, must be well ventilated to prevent a partial vacuum in the room. This
includes gas hobs. (A partial vacuum in the room could result in too high a
concentration of gas in the atmosphere).
• The appliance is supplied with an approved power cable which must not be
changed. If the supply cord of this equipment is damaged, it must only be
replaced by the manufacturer or its service agent or similarly qualified person in
order to avoid hazard.
Care and attention should always be taken when cooking with oils, alcohol, etc;
which give off flammable vapours.
Pre-used oil is especially dangerous in this respect. Do not use uncovered electrical
grill.
To avoid possible risks of fire always comply with the maintenance instruction below.
ATTENTION: This appliance must be earthed
When making the electrical connection, check that the socket has an earth
connection and that the voltage values correspond to those indicated on the rating
plate inside the appliance. The power socket connection is to be easily accessible
after installation.
CONTROL PANEL
The light and fan are controlled by a switch in accordance with the graphics printed on
MAINTENANCE
INSTALLATION OF UNIT
(Read in conjunction with the following diagrams)
The unit is designed for 2.4 to 2.7 metre high ceiling. The decorative chimney cover
is telescopic and is designed for 585 to 885mm adjustment.
Note: Ducting accessories are not supplied. Please refer to the optional ducting kits.
The air outlet from the motor requires 150mm round ducting which requires 160mm
diameter round hole in the ceiling. This hole will be covered by the decorative
chimney. Care should be taken to align canopy with decorative chimney allowing
sufficient clearance to accommodate the ducting.
Before starting assembly, read the instructions carefully and remove the filters from
canopy to allow access to wall mounting holes. To remove the filters, pull the
relative catch and tilting it downwards until it disengages from the supports.
Reverse these instructions when refitting the filters.
NOTE: Stainless steel is very easily damaged during installation if abraided or knocked
by tools.
IMPORTANT:
IF INSTALLING THE PRODUCT WITH A SPLASHBACK, THE SPLASBACK MUST
BE INSTALLED FIRST. THE SPLASHBACK WILL DICTATE THE INSTALLATION
HEIGHT OF THE PRODUCT TO THE COOKING SURFACE.
104804 Issue B
ECN: 04179
SCREW
CUP-WASHER
DECORATIVE
SCREW COVER
(4 PLACES)
8
7
9
9
9
6
INSTALLATION OF THE UNIT
WARNING: The distance between the hob and the mounting holes of the canopy
to be at least 855mm for 600 and 875mm for 900 models to ensure that the
fully installed canopy has a clearance of 700mm (recommended height) between
the lower part of the hood and the cooking hob. 1 Before drilling any holes check
the wall and the ceiling are clear of any electrical cables, pipes etc. Fixing to a
solid stud is recommended. 1
Fix the mounting washers in position shown in diagram. 1 Check with spirit level
across the washers to ensure they are level.
INSTALLING DUCTING
NOTE: All ducting must comply with local requirements and building codes.
Mark the position of decorative chimney at ceiling and wall, cut cornice moulding
away if necessary to enable panels to fit flat against the wall and ceiling. 2 Mark
and cut the hole in the ceiling to fit the ducting (160mm dia). 3 This is
positioned centrally with the canopy and 80mm from the wall.
INSTALLING CEILING BRACKET
Using the supplied screws, fix the ceiling bracket 4 to the wall, checking that it is
aligned with the hood.
FINALASSEMBLY
Remove protective plastic covering from all parts
including filters. Now fit the canopy on the fixed
mounting washers 5 . Plug in powercord at power
supply. Check function of rangehood light and
motor, before continuing assembly. Fix safety
screw 5 connect 150mm ducting. 6 Secure flexible
ducting with cable tie. 7 Assemble the telescopic
ducting cover covers 8 to accurately suit the
dimension required. 9 Mounting screw and plastic
cover caps are applied on top and bottom of the
chimney.
Electrical Rating:
385W (1.60A)
Max. at 230-240V 50Hz
RECOMMENDED UNIDUCT DUCTING
SYSTEMS FOR RANGEHOODS
WARNING
•This appliance is not intended for use by young children or
infirm persons without supervision.
•Young children should be supervised to ensure that they do
not play with the appliance.
•There shall be adequate ventilation of the room when the
rangehood is used at the same time as appliances burning gas
or other fuels.
•You must read the details concerning the method and frequency
of cleaning.
•There is a fire risk if cleaning is not carried out in accordance
with the instructions.
•Do not flambé under the rangehood.
•Exhaust air must not be discharged into an existing flue which
is used for exhausting fumes from appliances burning gas or
other fuels.
•The minimum distance between the hob surface and the lowest
part of the rangehood is 600mm. This distance shall be at
least 650mm ,if the rangehood is installed over a gas hob.
(We recommend 700mm)
•Attention should be given to ensure that any applicable
regulations concerning the discharge of exhaust air is fulfilled
•If the supply cord of this equipment is damaged, it must only
be replaced by the manufacturer or its service agent or similarly
qualified person in order to avoid a hazard.
Lamp Replacement
TO CHANGE A HALOGEN LIGHT
a) SWITCH OFF THE POWER TO THE RANGEHOOD
b) USE ASMALLBLADE SCREWDRIVER TO PRISE OFF
THE LIGHT COVER (NOTE SLOT)
c) USE A CLOTH TO REMOVE THE BULB. DO NOT TOUCH
THE BULB WITH FINGERS
d) REPLACE WITH A NEW BULBAND “SNAP” THE COVER
BACK IN PLACE
e) HALOGEN BULB 12Volt/20Watt
BULB
CONTROL
PANEL
LEFT SLIDER=
LIGHTS OFF & ON RIGHT SLIDER=
FAN OFF / LOW/ MED / HIGH SPEED
CONTROL LIGHT=
DUCTED
UNIDUCT FLEXI DUCT KIT is
recommended.
1569 Flexi Duct Kit (150mm)
For other Accessories, Parts or Service, please contact your local supplier or
approved service agent.
INSTALLATION OPTION ACCESSORIES
RECIRCULATED
Use Manufacturer Product code:
1742 (for 600mm unit)
1743 (for 900mm unit)
Operation
CUT CORNICE
TO CLEAR COVER IF PREFERRED
FIX TO SOLID
FRAMING
3
2
1
875 (900 MODEL)
855 (600 MODEL)
160mm DIA HOLE 80
CEILING
BRACKET
FIX SAFETY
SCREW AFTER
MOUNTING
CANOPY
KEYHOLES
IN REAR OF
CANOPY
(SHOWN
DOTTED)
4
5
5
IF SPLASHBACK IS USED,
THIS WILL DICTATE THE
INSTALLATION HEIGHT OF
PRODUCT
RECIRCULATING
OPTION
DUCTING
OPTION
155 mm
for
600
Model
175 mm
for
900
Model
1
700mm
UNDERSIDE OF HOOD
TO COOKING SURFACE
1
2.4 TO 2.7 METRE HIGH CEILING
IF SPLASHBACK IS USED,
THIS WILL DICTATE THE
INSTALLATION HEIGHT OF
PRODUCT
Arisit Pty Ltd
Australasian Distributor for Ariston Appliances
Ph: AUS (03) 9557 4044 - NZ (09) 306 10 20
TOP
GUIDE
RECIRCULATING
DUCTING

This manual suits for next models

1

Other Ariston Ventilation Hood manuals

Ariston Grease Filter User manual

Ariston

Ariston Grease Filter User manual

Ariston ISLT 65 AS X User manual

Ariston

Ariston ISLT 65 AS X User manual

Ariston ARHS 60X-L User manual

Ariston

Ariston ARHS 60X-L User manual

Ariston CX67SP6 X NG Installation guide

Ariston

Ariston CX67SP6 X NG Installation guide

Ariston AH 90 CM IX User manual

Ariston

Ariston AH 90 CM IX User manual

Ariston AGITUM850 User manual

Ariston

Ariston AGITUM850 User manual

Ariston HGF 9.5SS AB X User manual

Ariston

Ariston HGF 9.5SS AB X User manual

Ariston ARHS 60X User manual

Ariston

Ariston ARHS 60X User manual

Ariston ARH9SIX User manual

Ariston

Ariston ARH9SIX User manual

Ariston HLB 9.8 LTI X User manual

Ariston

Ariston HLB 9.8 LTI X User manual

Ariston AGITBG User manual

Ariston

Ariston AGITBG User manual

Ariston HES Technical manual

Ariston

Ariston HES Technical manual

Ariston ARHS60X-L User manual

Ariston

Ariston ARHS60X-L User manual

Ariston AGITUM520 User manual

Ariston

Ariston AGITUM520 User manual

Ariston ARU52S User manual

Ariston

Ariston ARU52S User manual

Ariston AHBS 9.3F LL X User manual

Ariston

Ariston AHBS 9.3F LL X User manual

Ariston HHVP 6.6F LM K User manual

Ariston

Ariston HHVP 6.6F LM K User manual

Ariston NIMBUS PLUS M NET User manual

Ariston

Ariston NIMBUS PLUS M NET User manual

Ariston SL 19 FX User manual

Ariston

Ariston SL 19 FX User manual

Ariston ARU52BX-L User manual

Ariston

Ariston ARU52BX-L User manual

Ariston RHB9IX User manual

Ariston

Ariston RHB9IX User manual

Ariston RHC60IX User manual

Ariston

Ariston RHC60IX User manual

Ariston AHVP 6.4F AL K User manual

Ariston

Ariston AHVP 6.4F AL K User manual

Ariston ARH6SIX User manual

Ariston

Ariston ARH6SIX User manual

Popular Ventilation Hood manuals by other brands

Whirlpool AKR 509 IX Instruction on mounting and use

Whirlpool

Whirlpool AKR 509 IX Instruction on mounting and use

Sirius Satellite Radio SLEM83 installation instructions

Sirius Satellite Radio

Sirius Satellite Radio SLEM83 installation instructions

Victory Typhoon 28 Installation guide and user's manual

Victory

Victory Typhoon 28 Installation guide and user's manual

sauter SHD 1589 X manual

sauter

sauter SHD 1589 X manual

Multikomplex SL909 cm 140 Installation, Use and Maintenance Instruction

Multikomplex

Multikomplex SL909 cm 140 Installation, Use and Maintenance Instruction

Atag WU50311BM Instructions for use

Atag

Atag WU50311BM Instructions for use

ZANKER ZKP9221X user manual

ZANKER

ZANKER ZKP9221X user manual

ROSIERES RHG580/1IN instruction manual

ROSIERES

ROSIERES RHG580/1IN instruction manual

AIRFORCE F300 Instruction on mounting and use

AIRFORCE

AIRFORCE F300 Instruction on mounting and use

Orbegozo DS 57190 B IN instruction manual

Orbegozo

Orbegozo DS 57190 B IN instruction manual

Think Appliances BAH6019 user manual

Think Appliances

Think Appliances BAH6019 user manual

Cooke & Lewis CLVH60W-C manual

Cooke & Lewis

Cooke & Lewis CLVH60W-C manual

Cata CHK60 manual

Cata

Cata CHK60 manual

GE Monogram ZV370YSS Dimensions and specifications

GE

GE Monogram ZV370YSS Dimensions and specifications

Inalto ASL60DR2S user manual

Inalto

Inalto ASL60DR2S user manual

Smeg SHW800B instruction manual

Smeg

Smeg SHW800B instruction manual

ROBLIN ACTIS PRO 57 Instructions for installation

ROBLIN

ROBLIN ACTIS PRO 57 Instructions for installation

Spagna Vetro AP238-PS15-36 Installation guide and user's manual

Spagna Vetro

Spagna Vetro AP238-PS15-36 Installation guide and user's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.