Ariterm Arimatic 151 User manual

ARITERM OY
Arimatic 151
User manual

v2.00 Ariterm Oy 21.5.2013
1
Contents
1. General .........................................................................................................................3
2. Transport, storage and package opening......................................................................3
3. Warranty........................................................................................................................3
4. Installation and commissioning .....................................................................................4
5. System description........................................................................................................5
6. Operating the system....................................................................................................6
7. Main pages....................................................................................................................7
7.1 MAIN PAGE ...............................................................................................................7
7.2 ALARMS -page ..........................................................................................................8
7.3 SETTINGS -page.......................................................................................................9
7.4 OPERATION -page..................................................................................................10
8. Options........................................................................................................................13
9. Time and date .............................................................................................................14
10. Language.....................................................................................................................14
11. Ignition.........................................................................................................................15
11.1 Automatic ignition...................................................................................................17
12. Effect............................................................................................................................19
13. Effect settings..............................................................................................................21
13.1 Feeding auger settings...........................................................................................21
13.2 Primary fan settings................................................................................................22
13.3 Secondary fan settings...........................................................................................23
14. Factory settings ...........................................................................................................23
14.1 Pellet auger............................................................................................................24
14.2 Pellet feeder PS10 (250-400kW)............................................................................25
14.3 Wood chip auger....................................................................................................26
15. Storage auger settings.................................................................................................27
16. Smoke gas fan.............................................................................................................28
17. Accessories .................................................................................................................29
17.1 Bar discharger........................................................................................................29

v2.00 Ariterm Oy 21.5.2013
2
17.2 Sweeping settings..................................................................................................30
17.3 Pulse extinguishing ................................................................................................31
17.4 Residual oxygen-control.........................................................................................32
17.5. Ash screws............................................................................................................34
17.6 MultiJet control.......................................................................................................35
17.7 Shunt control (Heating circuit control) ....................................................................36
17.8 Smoke gas temperature.........................................................................................38
17.9 Buffer tank control..................................................................................................38
17.10 GSM alarms .........................................................................................................40
18. Troubleshooting...........................................................................................................40

v2.00 Ariterm Oy 21.5.2013
3
1. General
Arimatic 151 control centre is designed to control 40-150kW bio heating
systems supplied by Ariterm Oy. The centre is suitable for controlling the
HakeJet, BioJet and MultiJet burners and the BioComp boiler. There are
several options available for the control centre, including ash auger control ,
residual oxygen (Lambda sensor) and GSM alarms.
The system is controlled with programmable logic (Siemens S7-1200). The
interface is a 4.3" graphic touch screen display. Arimatic 151 system burners
use energy-efficient and easy to adjust EC combustion air blowers.
2. Transport, storage and package opening
The centre is delivered with a platform. The package should be opened as
close to the installation site as possible. The centre should be stored indoors.
It is important that the recipient check the condition of the centre before
reception. In case of damage, the dealer must be contacted without delay.
It is important to inspect the contents of the centre after opening the package.
Sensors included in the centre are delivered in a separate package with other
equipment. Inspect the sensors by consulting the part list delivered with the
package.
3. Warranty
Ariterm provides a one-year warranty for its equipment. The warranty is valid
for one year starting from the date of implementation or for maximum of 18
months from the date of delivery.
The warranty covers craftsmanship and material defects. Ariterm Oy will
deliver new replacement parts for defective parts free of charge.
Spare parts are provided with a 12-month warranty.
The warranty does not cover damages resulting from incorrect installation or
thunder.

v2.00 Ariterm Oy 21.5.2013
4
4. Installation and commissioning
Install the centre in a place where the system is easy to use and cables are
easy to install. The centre should have 1 m of space in front of it.
Electrical connections should be done according to the wiring diagrams. The
wiring diagrams also indicate accessories. If no safety devices are connected
to the system, the respective terminal block should be short-circuited.
Example: Dry-boiling protection is not required for systems under 100kW. If
there is no dry-boiling protection, a permanent loop should be installed
between terminal blocks 10X1: 24 V DC and 41.
Current limits for the thermal overload relays and motor protectors should be
set according to the current value consumed by the motor. The current values
are indicated in the type plate of the motor.
The centre can be started once all electrical connections are completed. By
accessing the OPTIONS -menu from the SETTINGS -page, you can configure
system devices, such as Ash screw 1. Do not select functions/devices not
included in the system, because they may cause unnecessary alarms. NOTE!
The OPTIONS -menu can be accessed with Maintenance -level codes.
After completing system configuration, check the system for any alarms
caused by, for example, uninstalled or incorrectly connected sensors.
Functionality of all safety devices, such as emergency stop buttons,
thermostats and hatch switches must be tested/checked.
Then, check the rotation directions of screws and test all functions (fans,
screws/augers) in the MANUAL -menu.
The system has factory default settings, but certain settings, such as the
EFFECT -settings should be adjusted according to the fuel (Check chapter
14). Adjustments should be made by means of a flue gas analyser in order to
ensure clean combustion. Additionally the STORAGE AUGER -settings must
be adjusted based on the size of the funnel between the feeding auger and
the storage auger.
NOTE! If the system is equipped with automatic ignition, the AUTOMATIC
IGNITION -settings must always be defined case-specifically. The settings
should be made by an authorised maintenance professional during
commissioning. Incorrect ignition times and settings may result in a failed
ignition and halt the system.

v2.00 Ariterm Oy 21.5.2013
5
5. System description
The system is started with the AUTOMATIC -button, after which the ignition
pages open. If the flame detection system detects a flame in the burner head,
the burner switches to effect mode. After the ignition phase, the burner
switches to effect mode, during which the effect of the burner is adjusted
according to the required heating power. The automatic system attempts to
maintain the boiler water temperature at the set level. If a high level of heating
is not required, but the boiler water temperature increases excessively, the
burner will activate the upkeeping mode.
The burner uses the upkeeping mode to maintain ember in the burner head.
When the boiler water temperature decreases, the burner returns to the effect
mode. The user can stop storage operation and empty the burner screw by
NOT IN USE (STOP
mode)
- pumps are running
- flue gas fan is on
AUTOMATIC
IGNITION 1
1. Fanning
2. Funnel filling
3. Ignition load
4. Ignition
No flame
Flame
IGNITION 2
Constant voltage
EFFECT MODE
21-100% power
UPKEEPING
Ember
maintenance
Boiler temperature > Setting
+hysteresis
Boiler temperature < Setting +0.5 x hysteresis
Flame
ALARM
For example,
Emergency stop or
flame detection.
SHUTDOWN
- by the user
- Buffer tank
control (automatic
start-up)

v2.00 Ariterm Oy 21.5.2013
6
pressing the SHUTDOWN -button. This function is used, for example during
maintenance.
STOP -button stops the system immediately. Only the pumps and the smoke
gas fan remain in operation. These operations must be stopped manually.
In buffer tank use, the shutdown function is activated automatically, when the
lower temperature of the buffer tank exceeds its setting (e.g. 80°C). Automatic
ignition starts when the buffer tank temperature decreases below its setting
(e.g. 60°C).
Alarms are indicated with a red blinking light appearing on the display. The
ALARMS -page indicates the reason for the alarm and its time. You can
acknowledge alarms and review the alarm history.
6. Operating the system
The graphic interface makes it easy to control the system. The interface
contains four main pages: MAINPAGE, ALARMS, SETTINGS and
OPERATION. You can navigate the pages with the button located on the
bottom of the display.
ALARMS
SHUNT
BUFFER TANK
MAIN PAGE
page
SETTINGS
OPERATION
page

v2.00 Ariterm Oy 21.5.2013
7
The MAINPAGE displays the operation of the system. The page contains, for
example, temperature, blower power and the operation of the feeding auger.
The ALARMS -page displays active error notifications. You can also
acknowledge alarms and review the alarm history here.
The SETTINGS -page contains the settings menus where you can adjust the
parameters of various functions. The menus displayed are determined
according to the features activated in the OPTIONS -menu.
The system is operated from the OPERATION -page. The user can perform
operations manually, set the system run them automatically or stop the
system. The page also includes, for example, pump operations.
The system has two password-protected user levels: USER and
MAINTENANCE. The USER levels restrict access to all settings, preventing
unauthorised users from adjusting the settings. The USER level user name is
user and the password is user.
The MAINTENANCE level is for authorised maintenance professionals,
restricting access to, for example, sensor scaling settings, PID parameters
and OPTIONS-menu.
7. Main pages
7.1 MAIN PAGE
Figure 1. MAIN PAGE - burner in STOP mode.
The interface MAINPAGE contains the following items:

v2.00 Ariterm Oy 21.5.2013
8
- Burner mode (EFFECT MODE,UPKEEP, MANUAL, STOP)
- Boiler water temperature
- Effect percentage at which the burner is currently run
- Primary and secondary fan power
- Smoke gas fan power
- Operation of burner screw
- Operation of storage auger
- Funnel surface level sensor status
- Flame detection information
- Underpressure of combustion chambers
- Residual oxygen (if option is activated)
- Burner screw temperature (if option is activated)
- Bar discharger (if option is activated)
- Silo lower limit (if option is activated)
- Time and date.
System settings cannot be adjusted on the MAINPAGE. Settings can be
adjusted on the OPERATION -page.
7.2 ALARMS -page
Figure 2. ALARMS -page
Alarms are indicated with a red blinking light appearing on the display and the
system goes into Stop-mode. The ALARMS page displays active alarms

v2.00 Ariterm Oy 21.5.2013
9
(State), time (Active Time) and the reason for the alarm (Text). The source of
the alarm must be removed before the alarm can be acknowledged (Ack All
button). The alarms are recorded in the alarm history, which can be reset with
the Clear button.
The system must be restarted with the AUTOMATIC -button after
acknowledging alarms.
7.3 SETTINGS -page
Figure 3. SETTINGS page - all options selected.
The SETTINGS -page contains the settings menus where you can adjust the
parameters/settings of various functions. The menus displayed are
determined according to the features activated in the OPTIONS -menu.
The following menus are always displayed: EFFECT,BURNER SCREW,
STORAGE AUGER, PRIMARY FAN, SECONDARY FAN, SMOKE GAS FAN,
LANGUAGE and OPTIONS.

v2.00 Ariterm Oy 21.5.2013
10
7.4 OPERATION -page
Figure 4. OPERATION page - System in STOP mode.
The system is operated from the OPERATION -page. When the system is
stopped (STOP), the AUTOMATIC, MANUAL and STOP buttons are
displayed. The upper field indicates system status "STOP". When the system
is in the Automatic mode (burner in effect mode), the SWEEPING and
SHUTDOWN -buttons appear instead of the MANUAL -button.
If the Sweeping and Ash screw options are selected, their operating buttons
are displayed. These buttons can be used to override their scheduled
operation.
The system is stopped with the STOP -button. However, the cooling pump
and the smoke gas fan must be stopped with their dedicated buttons.

v2.00 Ariterm Oy 21.5.2013
11
MANUAL MODE
It is necessary to run the system manually during commissioning or, for
example, maintenance. If the user opens the manual operation page during
automatic operation (NOTE! STOP -button must be pressed first), the smoke
fan and pumps remain in operation. The following functions are controlled
here:
- Burner screw
- Storage auger
- Primary fan power adjustment
- Secondary fan power adjustment
- Smoke gas fan power adjustment
- Bar discharger system
- Ash screws
- Moving grate
- BACKWARD -button for reversing the screws/augers.
- Sweeping
- Cooling pump
- Hot air gun
NOTE! The buttons displayed on the MANUAL -page depend on settings
made (selected functions) on the OPTIONS -page.
Figure 5. Manual -page

v2.00 Ariterm Oy 21.5.2013
12
AUTOMATIC
If the burner is set to Automatic mode, the burner will activate the Effect -
mode, when the flame detection system detects a flame. Burner effect is
adjusted on a scale of 20-100%. If the flame detection does not detect a
flame, the system activates the controlled ignition phase (see section 11.
Ignition)
SHUTDOWN
This function stops the storage system operation and the funnel is no longer
filled. The system continues to operate as long as the burner screw and funnel
contain fuel. The operation stops, when the Alarm! Flame alarm is displayed.
The function can be used, for example, during preparations for boiler and
burner maintenance.
In buffer tank use, the shutdown function is activated automatically, when the
lower temperature of the buffer tank exceeds its setting. The burner will
remain in standby mode. The start-up command is given when the buffer tank
upper temperature falls below the set temperature.
STOP
This button stops all devices of the system, except for the cooling pump and
the smoke gas fan which must be stopped with their dedicated buttons.
SWEEPING
This button controls the convection sweeping motor, overriding their
scheduled functions.
ASH SCREW
This button controls the ash screws, overriding their scheduled functions.

v2.00 Ariterm Oy 21.5.2013
13
8. Options
All features/accessories of the system are configured in the OPTIONS -menu
during commissioning. Example: The woodchip system consists of the
hydraulic storage T1, MultiJet 60kW burner, pulse extinguishing system and
residual oxygen measurement. When using the system, the bar discharger,
moving grate, pulse extinguishing system and O2-control must be enabled in
the OPTIONS -menu. Then, the settings menus of the functions appear on the
SETTINGS -page.
NOTE! Make sure that unconnected options are not enabled. Otherwise they
may cause unnecessary alarms.
Available options:
1. Burner screw temperature
2. Pulse extinguishing
3. Burners cooling pump (BioJet)
4. Shunt control (Heating circuit control)
5. Bar discharger
6. Ash screw 1
7. O2-control
8. Smoke gas temperature
9. Sweeping
10. Ash screw 2
11. Moving grate (MultiJet)
12. Automatic ignition
13. Buffer tank
14. GSM (SMS alarms)

v2.00 Ariterm Oy 21.5.2013
14
Figure 6. OPTIONS -page
9. Time and date
Settings are displayed on the top left corner of the MAIN PAGE. You can
adjust time and date by pressing the respective button.
10. Language
You can select the OSD language by pressing a flag on the SETTINS -page.

v2.00 Ariterm Oy 21.5.2013
15
11. Ignition
If the AUTOMATIC -button is pressed on the OPERATION -page, the smoke
gas fan ventilates the boiler (2 min). If the flame detection does not detect a
flame, the user can select the Automatic or Manual ignition (NOTE!
automatic ignition is an accessory).
Figure 7. Ignition selection
MANUAL IGNITION
With the manual ignition, the user can manually run the burner screw or switch
on the primary or secondary fan.
If the automatic ignition option is enabled, the HOT AIR GUN -button will also
be displayed. The ignition can also be used for manual ignition.

v2.00 Ariterm Oy 21.5.2013
16
Figure 8. Manual ignition -page - Burner equipped with automatic ignition.
Run the burner auger with the BURNER SCREW -button so that the burner
head has enough fuel. The storage auger automatically fills the funnel while
the smoke gas fan maintains an underpressure in the combustion chamber.
Ignite the fuel and turn on combustion air fans. Wait for the fuel to properly
ignite. You can add more fuel to the burner head. When the flame is large
enough, the Ignition 1 -phase can be acknowledged with the MANUAL
IGNITION 2 -button, after which the system will proceed to the Ignition 2 -
phase.
During the Ignition 2 -phase, the burner is run at a fixed effect level, which the
user can adjust. In this case, the fuel feed and fanning is controlled
automatically. NOTE! During the first heating process, the burner should
be run at low power (21-30%) for approximately one hour in order to
remove humidity from the burner ceramics. When the flame detection
detects a flame, a flame symbol will be displayed . Then you can activate
automatic effect adjustment by pressing the MAN. IGNITION READY -button.
You do not need to wait for the flame information. The Ignition 2 can be
acknowledged earlier as well.
The flame information is provided by the flame detection thermostat
measuring the temperature of smoke gas. When the smoke gas temperature
exceeds the thermostat limit (approximately 70°C), the flame information is
displayed. The flame detection phase (10 min.) is activated after the Ignition
2-phase. During this phase, the smoke gas temperature increases over the
set temperature.
If the system is equipped with automatic ignition, the flame data is monitored
during the ignition with an optical flame detection sensor.

v2.00 Ariterm Oy 21.5.2013
17
11.1 Automatic ignition
If automatic ignition is enabled in the OPTIONS -menu, the AUTOMATIC
IGNITION -menu is displayed on the SETTINGS -page. NOTE! Only
authorised service professionals can adjust the automatic ignition settings.
Figure 9. AUTOMATIC IGNITION -settings
Setting
Factory
setting
Setting
frequency
Function
Flame value
True
value
0-100%
Displays the true reading of the optical
flame detection.
Flame limit
5%
0-100%
Flame detection limit value for the
optical flame detection sensor.
Flame delay
30s
0-360s
Delay during which the flame detection
should detect the flame.
Ignition step 1
240s
0-600s
Length of the Ignition 1 -phase, during
which the flame should be recognised.
Hot air gun and combustion air fans are
on.
Ignition step 2
600s
0-1200s
Length of the Ignition 2 -phase, during
which the burner runs at a set power
level before switching to automatic
adjustment.
Burner screw filling
time (short)
20s
0-360s
If the burner screw is full in the
beginning of ignition, the automatic
ignition can also be initialised with a
short ignition.
Burner screw filling
time (long)
20s
0-600s
The burner screw should be empty in
the beginning of automatic ignition.

v2.00 Ariterm Oy 21.5.2013
18
Then, the burner screw feeds fuel to the
burner head for the duration of the set
time. There should be an appropriate
amount of fuel in the burner head.
Hot air gun running
time at step 2
30s
0-360s
Hot air gun operation time after flame
detection (ignition phase 2).
The automatic ignition is initialised either by the user or automatically by the
accumulator upper temperature sensor. The storage auger automatically fills
the funnel and the boiler is ventilated before ignition. When the funnel is full,
the burne screw runs for the duration of the Burner screw filling time (long)
-setting, feeding an appropriate amount of fuel to the burner head. NOTE! If
the system is halted by an alarm while the burner screw is full of fuel, the user
can select a short filling time during ignition. During the short filling, the screw
will feed the burner head for the duration of the Burner screw filling time
(short) -setting.
The hot air gun and combustion air fans operate for the duration of the
Ignition step 1 -setting. If the flame detection detects a flame, the burner will
activate the Ignition 2 -phase. The optical flame detection sensor must detect
a flame during the duration of the Flame delay -setting in order to activate the
flame data. If the flame detection fails to detect a flame during the Ignition
step 1 -time setting, the fans and ignition stop and the Alarm! automatic
ignition alarm is displayed.
During the Ignition 2 -phase, the burner runs at a power level configured in
the Burner screw -setting for the duration of the Ignition step 2 -setting. After
this the burner automatically activates the effect mode. If the flame disappears
during the Ignition 2 -phase, the Alarm! Automatic ignition -alarm is
displayed.
Power settings for the burner screw and the combustion air fans during the
ignition phases are set in the BURNER SCREW/PRIMARY
FAN/SECONDARY FAN -setting pages.
The hot air gun can be activated by pressing the IGNITION UP->EFFECT -
button once the burner switches from Upkeep to Effect mode.

v2.00 Ariterm Oy 21.5.2013
19
12. Effect
Figure 10. EFFECT -settings
Setting
Factory
setting
Setting
frequency
Function
Temperature setting
80°C
0-100°C
Set boiler water temperature. The
burner maintains the set
temperature.
Measured temperature
True value
-10…150°C
True boiler water temperature.
Temperature
hysteresis
5°C
0-50°C
If the boiler water temperature
increases above the set boiler water
temperature by the amount of the
hysteresis, the burner activates the
maintenance mode. When the
boiler water temperature decreases
by 0.5 x hysteresis, the burner
switches back to power mode (E.g.
at 82.5°C)
Effect
True value
0-100%
True burner power
Manual effect setting
21%
20-100%
Burner power in manual operation
mode. The burner will run at a
constant power, until the boiler
water temperature increases over
the set temperature by the amount
of hysteresis.
Temperature sensor
scaling min
-10
-
150...150°C
Boiler water temperature scaling.
NOTE! Requires Maintenance level
password.
Temperature sensor
scaling max
150
-
150…150°C
Boiler water temperature scaling.
NOTE! Requires Maintenance level
password.
Table of contents
Popular Control Panel manuals by other brands

LinkAYL
LinkAYL LK-CP63 Series quick start guide

Siemens
Siemens SIMATIC TD 200 user manual

Controls
Controls MVP-L6100 product manual

Honeywell
Honeywell PL-1000 Installation and user manual

Securiton
Securiton SecuriFire 1000 Mounting and installation guide

SMART
SMART Watchdog Installation and operation manual