7
Doc.-no: PU21_PI21_1 issue: 01/2017
ABMESSUNGEN
9. Disposal
Dispose of parts so as not to endanger the human health or environment. Follow the laws
in the country of use for disposing of electronic components and devices during disposal.
ACCURACY / ERROR LIMIT:
< 0.5 %
< 0.5 %
< 0.2 %
< 0.15 %
Operating mode:
Measuring medium:
Measuring principle:
Smallest measuring range:
Largest measuring range:
Measuring range:
Measuring range selection:
Characteristic:
Ambient temperature:
Storage temperature:
TECHNICAL SPECIFICATIONS:
Measuring mode
Relative pressure
Monolithic ceramic technology
0...1 bar
0...100 bar
0...1 bar, 0...1,6 bar, 0...2,5 bar, 0...4
bar, 0...6 bar, 0...10 bar, 0...16 bar,
0...25 bar, 0...40 bar, 0...60 bar, 0...100
bar
factory preset
linear
-40...+85 °C
-25...+60 °C
Dimensions:
Weight:
Protection class:
Electrical connections:
Pressure connections:
PHYSICALLY:
ø 28 mm, ca. 97 mm lang (incl. plug)
approx. 220 g
IP65 according EN 60529
Angel connector according DIN 43650
G1/2“, SW 27
Zero drift:
Sum of linearity and hysteresis:
Temperature drift zero point:
Temperature drift measuring range:
Power supply:
Output:
ELECTRONIC:
13...30 Vdc
0...10 V, three-wire circuit
EMC:
RoHS:
CONFORMITY:
EN 61000-6-2, EN 61000-6-3, CE-mark
according RoHS-directive 2011/65/EU
10. Specication