Artize QUADRO OXYPOOL User manual

OWNER'S MANUAL
QUADRO OXYPOOL

Safety, Operation, Maintenance, and Warranty
SAFETY GUIDELINES
This manual contains information for YOUR SAFETY and will also help
in PREVENTING PROBLEMS. To help you recognise these items of
importance, this document uses the following symbols. PLEASE read
the manual and pay special attention to these sections.

02
SAVE THESE INSTRUCTIONS!
Urgent Safety Information
A Hazard That Will Cause Serious Injury
Important Safety Information
A Hazard That Might Cause Serious Injury
Information To Prevent
Damage To Equipment
Important Instructions and
References
DANGER !
WARNING
CAUTION
Model:
Serial/ Invoice No.:
Owner's Record
Date of Installation:
Name of Installer:
Telephone:
This information may be required for service and warranty.

03
IMPORTANT SAFETY INSTRUCTIONS
Basic precautions to be taken to prevent fire hazards, electrical shocks, personal injury or damage
when using your unit. READ AND FOLLOW ALL INSTRUCTIONS!
• Risk of lethal electric shock in Hydroelectric product. To reduce risk of electric shock, connect your product only to circuits protected
by a Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD)-sensitivity not more than 30 Milliamp (mA)
• CIRCUIT INTERRUPTER (GFCI). A GFCI should be provided by the entrepreneur electrician and should be routinely tested. To test the GFCI,
push the test button. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this
manner, there is a ground fault, indicating the possibility of electrical shock. DO NOT USE THE UNIT. Disconnect the unit and have the
problem corrected by a qualified electrician before using
• Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening. Do not use electrical
appliances while in the tub
• To reduce the risk of injury, do not allow children to use this unit unless they are closely supervised at all times. Those requiring supervision
should never be allowed to use the units unattended
• Use the unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer
• Never drop any objects into any openings/holes within the product.
• Do not use the oxypool if the protective cover is not installed on the suction intake. Keep foreign objects, including hair, away from the
suction intake as they could block the intake or get caught in it. For comfort and safety, persons with long hair should tie their hair in a bun
to keep it out of the water and away from the suction fitting. Keep your head above water at all times
READ AND FOLLOW ALL INSTRUCTIONS
DANGER !

04
• Persons under a doctor's care, pregnant women, persons with high or low blood pressure, heart disease, diabetes, or any serious illness,
should not use this unit without prior consultation with their physician. Never use this unit while under the influence of any drug or alcohol.
• The maximum temperature of the water should never exceed 104°F (40°C).
IMPORTANT SAFETY INFORMATION
WARNING
• To reduce risk of injury, enter and exit the bath carefully.
• Do not fill the tub beyond the air volume controls or the overflow.
• Never operate the oxypool system if there is less than 2" (5 cm) of water over the highest whirlpool jet (except for the back jets) or if the
bathtub is empty.
• Do not bathe pets in your whirlpool. Their hair could clog the pump.
• Make sure the water temperature does not exceed 104°F (40°C). Damage and discoloration of the acrylic surface may occur.
• The oxypool should be drained after each use.
• Oil-based additives must not be used, and cleaning instructions must be followed. Do not use harsh abrasives or solvents for cleaning
your oxypool.
INFORMATION TO PREVENT DAMAGE TO EQUIPMENT
CAUTION
• SAVE THESE INSTRUCTIONS •

05
Dear Product Owner,
Thank you for choosing an Artize product. The minute you sit back and relax
in your new product you'll see and feel the difference. In your whirlpool, jets
are strategically placed to create a soothing, swirling flow of relaxing water.
It's the OXYPOOL action which you'll only experience in Artize products..
Now relax and enjoy your bath in your new ARTIZE OXYPOOL.
Sincerely,
Artize.

06
Oxypool Specifications-------------------------- 07
Oxypool and Bathtub Sizes--------------------- 08
Installation Legend Diagram-------------------- 9
Pre-installation Requirements------------------- 10
Tools For Installation
Before You Start
Installation Procedure---------------------------- 12
Electrical Supply and Safety Devices
Components Identification
Block Connection Diagram--------------------- 16
ECU Terminal Connection Diagram
Operating The Controls-------------------------- 18
Electronic Control
How To Use Your Oxypool---------------------- 19
User Maintenance Instructions----------------- 20
Cleaning The Tub Surface
Cleaning the Pump and Plumbing System
Minor Scratches and Scuffs
Major Repairs To The Surface
Jet Hardware Wrench
Troubleshooting---------------------------------- 22
Oxypool System
CONTENT

07
SAFETY
3 Tier Testing Yes
Steel Frame Yes
Sanitisation/
Cleaning System No
Food Grade Pipe Yes
Level Sensor Yes
Digital Yes
Manual No
Cross No
Smart No
Body 5 years
Electrical 2 years
Jets 5 years
SANITISATION
CONTROLLER
WARRANTY
TECHNICAL INFO
Size
Depth
Material
Reinforcement
Oxypool Jets
Pump Oxypool
Chromotherapy
Headrest
Overflow Cum Filler
Keypad
Power Rating (Max)
1900*900x660/mm
500mm
Acrylic
PU
2
1.8 HP
Yes (2)
Yes
Yes
Yes
1.5KW
OXYPOOL (ARTIZE190X90)
S. No. DESCRIPTION REMARKS
1 Packing Weight 70Kg
2 Dry Weight 56.7Kg
3 Water Capacity (Ltr) 270Ltr
OXYPOOL SPECIFICATION

OXYPOOL BATHTUB SIZES
Product Dimensions
Top View
A
Side View
B
Control Panel
1293
1586
1900
314
70
138
440 460
91
684
900
08
1900
510
610
660
50

9
INSTALLATION LEGEND DIAGRAM
References for Installation
1200
200
120
C1/F1
150
08
200
400
380
120
100
1535
01
c.v.
A : Outer dimensions
* Bathtub depth
** Dimensions relative to the panel.
B : Inner dimensions
C : Legend for installation or product placing
O1 : Area for drainage sunken in floor.
C1 : Area for hot water pipe outlet from the
house. Water mains in case ARTIZE taps
are installed on tub edge
F1 : Area for cold water pipe outlet from the
house.Water mains in case ARTIZE taps
are installed on tub edge.
C.V.: Suggested area for electrical input
wall outlet.
Refer to product drawing / installation legend for marked references.

10
PRE-INSTALLATION REQUIREMENTS
Tools for Installation
Safe use of tools:
• Wear safety glasses or a face shield (with
safety glasses or goggles) and well-fitting
gloves for safety.
• Ensure that users are properly trained in the
safe use of hand tools.
• Select the right tool for the job. Substitutes
increase the chance of having an accident.
• Replace cracked, splintered, or broken handles
on files, hammers, screwdrivers, or sledges.
• Ensure that the handles of tools like hammers
and axes fit tightly into the head of the tool.
• Use and maintain tools carefully. Keep them
dry and store them properly after each use.
Tools Required For Installation: (Not Included)
#10 x 1 " self –tapping
washer head screw
OR 1 " Galvanized roofing nail
Safety Glasses
3/16"
Drill Bit
Drill
Hammer
Level
Pencil
Phillips Screw Bit
Tape Measure

11
Before You Start
IMPORTANT: Observe all governing codes
and ordinances.
1. Proper installation is your responsibility. Ensure a
qualified/Jaquar technician installs your product.
2. An air vent and a service window must be
provided for product as basic requirement.
3. Electrical supply requirement: 220~240 volt (16 A)
Fluctuation may damage the product or its
component. Manufacturer recommends the use
of fluctuation free or stabilized power supply to
feed the product.
4. Water supply parameters like pH/hardness must
be maintained at below recommended level.
pH 7.5 – 8.5
TH 150 – 450 ppm.
Sanitizer 2- 4 ppm
Electrical Supply and safety devices.
a) The equipment must be connected to single phase
220 ~ 240 V and 50hz supply.
b) The equipment must be connected to the
equipotential/ differential switches of the room and
duly fastened to the specified clamp/terminals that
can be found on the product.
c) Connection to the power mains foresees installation
of a 30mA max. differential switch
(RCCB/ELCB/GFCI), with at least 3 mm contact
opening and suitable for a single phase supply.
d) Switches must be arranged near the device,
upstream of power boxes (only for product versions
equipped with power box).
e) The product’s supporting structure is made of metal,
therefore an efficient ground dispersal provision is
required, with regulations compliant sensitivity.
Earth Wire
The earth wire must be connected and fixed permanently
with a 3 mm dia. core conductor to the electrical system.

12
INSTALLATION PROCEDURE
Place your oxypool/bathtub on flat surface & check
level for water flow towards drain.
Water drain may be adjusted by leg adjustment
Pictures used above for reference only.
For product placement check dimensions
of required model.
Level measurement

13
Note: Connecting pipe (Flexible pipe of diameter 40)
Pictures used above for reference only.
For product placement check dimensions
of required model.
Fill a minimum 4 litres of water in the bathtub to
check proper drain flow
Connecting drain pipe : Use a flexible pipe of
diameter 40 mm - not supplied with the product.

14
Electrical supply and
safety devices
f) The equipment must be connected to single
phase 220 ~ 240 V and 50hz supply.
g) The equipment must be connected to the
equipotential/ differential switches of the room
and duly fastened to the specified clamp/
terminals that can be found on the product.
h) Connection to the power mains foresees
installation of a 30mA max. differential switch
(RCCB/ELCB/GFCI), with at least 3mm contact
opening and suitable for a single phase supply.
i) Switches must be arranged near the device,
upstream of power boxes (only for product
versions equipped with power box).
j) The product supporting structure is made of
metal, therefore an efficient ground dispersal
provision is required, with regulations compliant
sensitivity.15
It is recommended that the product be kept filled for 24 hours to
check for leakages in plumbing/drain connections.
3
24h
12
9
6
S
ILI
CO
NE
±5%
20min
12
39
6
16s
12
39
6
4s
12
39
6
12
39
6

15
These drawings represent only the major components of the system; the position of the components
may vary depending on the bath model.
These pictures represent Combined Systems; Oxypool Systems components are identified with
“Component Identification”.
Component Identification
DRAIN KNOB
KEY PAD
CHROMO LIGHT
ELECTRONIC BOX
WATER MOTOR
WATER SUCTION
OXY JET

16
BLOCK CONNECTIONS DIAGRAM
Technical Data
Nominal voltage 220-240v AC 50/60Hz
Total connected load max. 15kw (max. 6A)
Switching current each channel 6A at cos phi = 1
Power Vcc1 max. 10w
System of preotection IP55
Housing dimensions 130x95x60mm
1 2 3 L 5 6 7 N 9 10 11 PE
1234
S 1
ON
4 N 8 PE 12
D6
D4
26
25
Vcc1
29 28
1
E5
E4 E3 E2 E1
S06
E6
13
E1 mains voltage supply
E2 pump or blower
E3 RGB Light 1
E4 RGB Light 2
E5 TL5 whirlpool
E6 switch whirlpool
1 DP-switch for sellings
28, 29 EGB Light
D6 LED for TLS- control
+12V black
brown
blue
+12V Vcc
common
waler
air
light RGB-1 button
lght RGB
light-slup
motor valve
side-LED
GND
26
25
24
23
22
21
20
19
18
17
16
15
14
13
2 but.
switch
whirl.
TLS
whirl.
DP-switch NO OFF
S1.1
S1.2
S1.3
S1.4
supply voltage Vcc1
10v / 5v
TLS-sensor RGB light
deactivated / active
* dry out
automatic / manual
interval
ON / OFF
WHIRL POOL CNTROL TYPE 240 9043C - S06

17
Ecu Terminal connections Diagram
Oxypool Lighting Connection
Sxx
29 28
S1_1 = ON
Vcc1 = 10V
(RGB LED SPOT 10V)
S1_1 = OFF
Vcc1 = 5V
(Effect Light Chain)
(RGB LED SPOT 5V)
1 2 3 L
4H 8
PE
12
5 6 7 N 9 10 11 PE
ON
S1 DL
26
25
D6
13
1 2 3 4
Double RGB LED Spot
010 5301B
10V DC
1,5W
Double RGB LED Spot
010 5301B
10V DC
1,5W
RGB light max. 10W
- 5 -

18
OPERATING THE CONTROLS
STOP
Position Symbol Fuction
Oxypool1
2
3
Light On
Light Stop

19
HOW TO USE YOUR OXYPOOL
BEFORE TAKING YOUR FIRST BATH, READ AND APPLY THE "IMPORTANT SAFETY INSTRUCTIONS".
To reduce the risk of injury, do not permit children to use the oxypool unless they are closely supervised at all times. Those requiring
supervision for any reason, should never be allowed to use the oxypool unattended. Persons under a doctor's care, pregnant
women, persons with high blood pressure, heart disease, diabetes, or any serious illness, should not use a oxypool without prior
consultation with their physician. Never use a oxypool while under the influence of any drugs or alcohol.
Do not use the oxypool if protective cover is not installed on the suction intake. Keep foreign objects, including hair, away from the
suction intake as they could block the intake or get caught in it. For comfort and safety, persons with long hair should tie their hair in
a bun to keep it out of the water and away from the suction fitting. Never place your head below the surface of the water.
TIME TO RELAX
It's time to relax, unwind, daydream, meditate. Lie back and relax while the effervescent oxypool action works on your body and
floats away your cares.
WATER TEMPERATURE
Warm to moderately hot water is ideal for a relaxing and comfortable whirlpool bath. That temperature is between 100° F and 102°
F. The maximum water temperature should never exceed 104° F. If your system uses the electronic control with back lighting, the
LCD displays the temperature when the system is on. Try cooler water for an invigorating oxypool.
Temperatures exceeding 104°F may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches
a level several degrees above normal body temperature of 98.6° F. The effects of hyperthermia include: failure to perceive heat,
failure to recognise the need to exit the oxypool and unawareness of pending hazards.
FILLING THE TUB
When the tub is filled with water above the highest jet, step in and sit down before turning the whirlpool on. Do not fill over the air
controls or bath waste handles. We recommend this procedure for two reasons. Some switching systems will not work unless the
bather is in the oxypool and the action of the water can alter your sense of touch and balance as your foot "seeks" the bottom of
the tub.
TURNING ON THE OXYPOOL
Turn on the pump by pressing or touching your controls as described previously in the section on Operating the controls.
Table of contents
Other Artize Bathtub manuals
Popular Bathtub manuals by other brands

Empava
Empava EMPV-JT367 Installation instructions and owner's manual

RAVAK
RAVAK SUPERNOVA VSK 2 ROSA installation instructions

BATH DELUXE
BATH DELUXE Wellino Combi Series installation guide

Kohler
Kohler K-1114P-GLF Roughing-In Guide

Kohler
Kohler K-18347X Installation and care guide

Signature Heardware
Signature Heardware Copper Tub Installation and care guide