1) A optical transmitter or receiver
2) A 20VDC/2500mA DC power adapter
3) A user's manual
Optical transmitter
1. Output power working normally in the first beginning but it is not working when reconnecting.
Solution: clean the optical connector with alcohol or change optical connector
2. Using optical power meter for testing, output power work normally. But it not working when
connect to link.
Solution: checking the type of optical connector if APC. If in PC or UPC, use optical Fiber Patch
Cord for connecting Optical Receiver
3. Input with optical signal but no RF signal output-
Solution: Check OPT indicator light, if the light off, the input optical power is lower than
working range, if the light in red, the input optical power is higher than working range. Please
be sure input optical power is in the working range.
4. RF signal output working normally when testing, but here not have RF signal output when install
on designated spot.
Solution: Check if there any pollution on designated spot and clean the optical connector with
alcohol. Also it will have same problem relevant to space on designated spot. If fiber cable
bending in large, it will lead to excessive loss of fiber. Please install the optical receiver in the
right position.