Ascon Tecnologic - TC32- - OPERATING INSTRUCTIONS - PAG. 3
2.2 Standard mode parameters setting
To access the instrument functionning parameters when
password protection is disabled, press the key for 5 s,
after which the display shows the code that identifies the first
programmable parameter, at this point use the / keys
to select the parameter that is to be changed, then press the
key, the upper display shows the parameter code and
the lower one its value that can be changed with the and
keys. Once the desired value has been set, press the
key again: the new value is stored and the upper display
shows only the code of the modified parameter.
Pressing the or keys, it is possible to select another pa-
rameter and change it as described. To exit the programming
mode, press no keys for about 30 s or keep the key pressed
for 2 s, the timer returns showing the actual count value.
PARAMETERS
SET PA RAMETER
Increase
value
Decrease
value
s.lt1.
10.25
NORMAL MODE
s
Hold
for 5 s
Previous
Parameter
Next
Parameter
s.lt1.
99.59
30.50
2.3 Parameter protection using a password
The instrument has a parameter protection function using a
password that can be personalised through the t.PP parameter.
To protect the parameters, set the desired password number
at parameter t.PP and exit the programming mode.
When the protection is active, press the key for 5 s after
which the display shows r.p. Press the key again, the
display shows 0. Using / keys, insert the programmed
password number and press the key again.
If Password is correct the upper display shows the code of
the first programmable parameter. Now is possible to pro-
gram the instrument in the same way previously described.
Password protection can be disabled by setting t.PP = oF.
PARAMETERS
(PR
INS. CORRECT
PASSWORD
PASSWORD
REQUEST
Increase
Value
Decrease
Value
r.pas.
10.25
NORMAL MODE
s
Hold
for 5 s
r.pas.
0
30.50
S.lt1.
Notes: 1. All parameters are configured by default as “pro-
tected” so that by simply setting the t.PP param-
eter they are all protected by the Password.
2. If the Password gets lost, just switch OFF then
ON the instrument, push key during the initial
test keeping it pressed for 5 s. In this way it is
possible to access all the parameters, verify and
modify the parameter t.PP.
2.4 Customized mode parameter programming
(parameters programming level)
When activated, the password protection acts on all parame-
ters. If, once enabled the Password through the t.PP param-
eter, it is necessary to make certain parameters program-
mable without protection while keeping the protection on the
others, follow the procedure below:
–Enter the programming mode using the t.PP Password
and, with / keys, select the parameter that must be
accessible (not password protected).
–Once the parameter is selected, if the SET LED flashes,
the parameter is programmable only entering the pass-
word (
protected
). If SET LED is steady ON the parameter
is programmable without password (
unprotected
).
–To change the parameter visibility, press the key and,
keeping it pressed, press also the button.
–The SET LED changes its state indicating the new level
of the parameter accessibility (ON =
Not protected
; Flash-
ing =
Password protected
).
In case some parameters are set as Not protected, access-
ing the programming mode the display first shows the Not
protected parameters, then the r.p parameter through which
will be possible to access also the protected parameters.
SET
PA RAMETER
NOT PROTECTED
PA RAMETERS
Increase
Value
Decrease
Value
f.cnt.
10.25
NORMAL MODE
s
Hold
for 5 s
f.cnt.
up
30.50
Increase
Parameter
Decrease
Parameter
PARAMETERS
(PROGRAM MODE)
INS. CORRECT
PASSWORD
PASSWORD
REQUEST
Increase
Value
Decrease
Value
r.pas.r.pas.
0
S.lt1.
2.5 Reset parameters to default value
The instrument allows to reset all parameters to those values
programmed in factory as default. To restore the default
parameters value, answer -48 to r.p password request.
Therefore, to make the reset to default parameters, enable
the Password protection using the t.PP parameter so that the
r.p setting is requested, at this point insert -48 instead of the
programmed access password. Once confirmed the pass-
word with the key the display shows “---” for 2 s, then the
instrument resets all the parameters to factory default setting.
2.6 Keyboard lock function
It is possible to completely lock the keyboard. This function
is useful when the controller is used in an accessible area
and unauthorized changes must be avoided.
To activate the keyboard lock, program the parameter t.Lo to
a value different from oF. The t.Lo value is the keys inactiv-
ity time after which the keyboard is automatically locked.
When the keyboard is locked, if any of the key is pressed, the
display shows L.n to indicate that the lock is active. To unlock
the keyboard, press contemporarily + keys and keep
them pressed for 5 s, after which the label LF appears on the
display and all the key functions will be available again.