Aseko ASIN Pool User manual

1
L N PE
GNDA B2 3 4 5 6 GND GND
REL 1 REL 2 REL 3 REL 4 REL 5 REL 6 REL 7
GND
n1 n2 n3
STOP
SENSOR POWER
USER MANUAL
www.aseko.com
ASIN Pool
INTELLIGENT NETWORK CONTROLLER
to Control the Pool Technology with Smartphone
ASIN Pool VS Pump Module
1
EN

EN
2
General Safety Information
This user manual has basic information that should be observed during
assembly, start-up, operation, and maintenance. Therefore, this user
manual must be read by installers and operators prior to assembly and
start/up, and must be accessible to every user of this unit. Additionally,
allfurther safety information in this document absolutely must be observed.
Readand follow all instructions. In order to minimise the danger of injury,
donot allow children to use this product. Hazards from non-compliance with
safety information. Non-compliance with safety information can result in
hazards to persons, the environment, and the equipment. Non-compliance
with safety information will result in a forfeit of any potential right to damage
compensation.
Non-Observance of Safety Instructions
Failure to observe the safety instructions given in this User Manual can result
in damage to Device and/or health and property, including environment.
Failure to observe the safety instructions and information given in this User
Manual shall result in exclusion or restriction of the prospective right to
compensation for damage.
Insufficient Qualification of Person Using the Device
Hazards in the event of insuciently qualified personnel,
potential consequence: Injury, heavy material damage.
• The system operator must ensure compliance
with the required qualification level.
• Any and all work may only be performed by
correspondingly qualified personnel.
• Access to the system must be prevented for insuciently
qualified persons, e.g. via access codes and passwords.
Connection of power supply must be provided by person with
corresponding qualification. Opening the unit cover or change
of any components of the unit is prohibited.

EN 3
Non-compliance with informational text
There is a great deal of informational text indicating hazards and their
avoidance. Not observing informational text may lead to hazards. Potential
consequence: gravest degree of injury, heavy material damage.
• Read all informational text carefully.
• Cancel the process if you are unable to exclude all potential hazards.
Use of Device New Functions
Because of the continued development, a ASIN Pool®unit may contain
functions, which are not completely described in this version of the user
manual. The use of such new or extended functions without a profound
and secure understanding by the operator may result in malfunctions and
severe problems. Potential consequence: Injury, heavy material damage.
• Make sure to get a profound and secure understanding of a function
and relevant boundary conditions, before you start to use it.
• Check for an updated version of the user manual or additional
documentation available for the relevant functions.
• Make use of the integrated help function of the ASIN Pool®to get
detailed information on functions and their parameter settings.
• In case it should not be possible to get a profound
and secure understanding of a function based on the
available documentation, do not use this function.
Conditions to be Met before You Start Using Device
Make sure you have a newest and updated version of the user manual
and other documentation for all functions of the unit. Use and read the
integrated help features. In case of not understanding the information
about certain features of the unit, do not use these features.
Pool cover
Operate the pool cover only if you have clear view of the pool. Watch
the pool whole time that cover is on the move. Operating the cover
without the clear sight of the pool can cause serious injuries or death.
The remote control of the swimming pool cover may
be in violation of the laws of your country.

EN
4
1
L N PE
GNDA B2 3 4 5 6 GND GND
REL 1 REL 2 REL 3 REL 4 REL 5 REL 6 REL 7
GND
n1 n2 n3
STOP
SENSOR POWER
ASIN Pool Electrical Box
ASIN Pool
1
L N PE
GNDA B2 3 4 5 6 GND GND
REL 1 REL 2 REL 3 REL 4 REL 5 REL 6 REL 7
GND
n1 n2 n3
STOP
SENSOR POWER
ASIN Pool # 12166 VS Module # 12167
110 mm
155 mm
110 mm
55 mm
ASIN Pool Electrical Box # 12168
??? mm
??? mm
??? mm
??? mm

EN 5
Technical specification
Power supply 110-240 VAC / 50 Hz / 60 Hz
Input power 10 VA
Overvoltage category II
Protection degree IP30
Climatic resistance +5 to +40°C
Weight 800 g
Installation wall DIN rail mounting
Relay output contacts max 230 V / 1 A, potential free contact - NO
Dimensions 155 x 110 x 60 mm and 55 x 110 x 60 mm
Sensor power supply 6 x 18 VDC / max 50mA
Accessories for Purchase
Water thermometer with holder #12010 Air thermometer #8953 Solar collector thermometer #8953
Solenoid valve (water filling) #13153
Pressure-type level sensor #12086
5-way BESGO valve (backwash) 3-way BESGO valve (flow switch)

EN
6
ASIN Pool
The network controller.
The ASIN Pool network controller is designed to control and set all the pool
technology elements:
• Lights or pool cover
• Automatic water filling
• Solar collector pump
• Heating
• Flow control over/bottom
• Automatic filter backwash
The ASIN Pool can be set by user friendly application. TheASINPool is
intended for the DIN rail mounting directly into the switchboard.
Lights Water level
meter
Heating
Automatic
water filling
Over/bottom
3-way
BESGO valve
VS Filtration
pump
Backwash
5-way
BESGO valve
Solar
collector
pump
Pool cover
INTERNET
LAN
Pool Technology
Connected
HOME
NETWORK

EN 7
INTERNET
LAN
Pool Technology
Connected
HOME
NETWORK
HOME ROUTER
iPool REMOTE
app for
iOS and Android
Real time
secure
communication
Real time
communication
SSL protected
ASEKO
SERVER
Protected
safe located
ASEKO
WEB
SERVICES

EN
8
Initial start
ASIN Pool will turn to standard operating mode with factory settings after the
initial connection of power supply. After repeated switching on the unit continue
in the original mode preset by user.
LED Power shines – signalize connected power supply
LED Auto shines – ASIN Pool works in standard operating mode
with automatic control.
Manual mode
It is possible to use buttons at the front panel of ASIN Pool for simple
control intesting operation when necessary to check function of connected
components or in extreme cases when there is no available connection to
ASINPool by application.
Press the button ON/OFF for switching the ASIN Pool o or on. ASIN Pool
switches all outputs o and after switching on will continue in the preset mode.
Press the SELECT button to enter the manual mode. ASIN Pool will switch o all
outputs and blue LED at the (HEATING) output start blinking. You can switch on
or o the selected output by pressing ON/OFF button and move to next output
by pressing SELECT. This way you can switch on or o all outputs. There will not
blink any blue LED (after 8 press of SELECT button) and you can leave ASIN Pool
or in manual mode or by pressing ON/OFF button return to automatic mode.
Manual Operation
For easier installation and necessary events...
1
L N PE
GNDA B2 3 4 5 6 GND GND
REL 1 REL 2 REL 3 REL 4 REL 5 REL 6 REL 7
GND
n1 n2 n3
STOP
SENSOR POWER
Turning on/off
POWER:
On/O
AUTO:
automatic mode / manual
mode (testing)
Relay status indication:
ON/OFF
Relay selection

EN 9
Mode selection
OFF All STOP
ON Nonstop filtration
PARTY Nonostop filtration, heating ON.
Mode for using the pool at the time of your wild party.
AUTO Automatic mode, heating ON
Mode for common fully automatic operation of swimming
pool technology.
ECO Saving mode, heating OFF
Mode for economical operation of the pool in your absence.
WINTER Antifreeze mode
Mode for winter pool operation when not in use.
Direct control
Filter backwash
Pool cover
or
Lights
Operation via iPool REMOTE
iPool REMOTE
app for
iOS and Android

EN
10
iPool REMOTE Installation
Install the iPool REMOTE application from App Store on iOS device
or Google play for Android.
FIRST TIME
LOGIN
First time login
Prior to the first connection to the ASIN Pool, confirm your acceptance
of “ASIN Pool Terms and Conditions”.
Type your serial number
Enter the serial number of your ASIN Pool.
First time login
Please, be sure tu use 1234 as a password for first time login.
For iOS For Android

EN 11
Create new password
Type your serial number
Enter the serial number of your ASIN Pool.
Recovery email
Provide a valid email address to which you have access. E-mail address
serves to remind the forgotten password.
Create new password
When signing in for the first time, choose a password you will use. ASIN Pool
will remember the password. From this moment use the serial number and
this password to log in to your ASIN Pool.
Installation time zone
Set the time zone of the ASIN Pool location.
Forgotten password
To recover a forgotten password, click for reminding the password.

EN
12
Overview
The screen provides all the important information about the current status
ofyour pool and the connected components controlled by ASIN Pool.
Overview Remote
Mode Settings
Water temperature, air temperature, solar panel temperature
Pool technology status
ASIN AQUA paired device status
Actual operation mode
Reload data

EN 13
Mode selection
The screen serves to switch between operation modes of your pool controlled
via ASIN Pool.
This mode switches the circulating pump on
speed MEDIUM and heating to the required
temperature.This mode has no time functions.
All o, only in case of solar panels reach the
preset temperature the filter pump and solar
circulation pump are switched on.
Filter pump is set on MEDIUM speed. This mode
has no time functions. The water flow is set to
OVER, and heating is set toOFF.
This mode is intended for normal pool operation.
Heating to your required temperature. At four
time intervals per day it is possible to set the filter
pump’s power and set whether an overflow or
bottom drain will be used.
This mode is designed to operate the swimming
pool in your absence or when you want to
operate economically.
To activate this function, an outdoor
thermometer must be installed*.
Thecirculation pump switches on for 15 minutes.
After15minutes the water temperature is
measured. If the water temperature is below 4°C
the heating and circulation pump is switched on.
When this temperature is reached, the circulation
pump is switched o. Further control of the water
temperature and switching on of the circulation
pump will happen in 6 hours.
*) If outdoor temperature is below 0°C
The slider serves
to control your pool
operation modes.

EN
14
Direct control
Switches on the filter
backwash process
Open / close cover
or
Turns the lights on/off

EN 15
Settings
The screen serves to set the ASIN Pool and parameters
of each mode including the filtration timer.

EN
16
Smart heating
Heating at Time
This function allows to set time of heating operation. This is particularly
useful for switching on the heat pumps that have higher eciency during the
day time when outdoor temperature is higher.
Heating at air Temperature
This function allow you to customize the pool heating and achieve the
highest possible eciency of the heat pump.
“I heat just when the outdoor temperature is higher than ......,
or I heat just till the outdoor temperature reaches ...... .”
The high-accuracy electronic thermometer is used for water temperature
measurement. It should be installed to the inlet pipe comming from the pool.
Never install it downstream of the heat exchanger. Significant distortion of
temperature would occur.
When temperature drops below the required value, the relay No. 1 switches
on the heat source (heat pump, electric heating, gas boiler circulating
pump).
Temperature Control Takes Priority over Filtration
Control
If you select the temperature control to take priority over the filtration timer,
heating as well as the circulating pump will be in operation even after the
adjusted time of filtering. The circulation pump will stop after the required
temperature is achieved. It will restart at next preset period of the timer.

EN 17
Watter filling
The water level is measured by the level sensor. This allows very easy
installation by inserting the sensor into the balance tank or skimmer.
Water Level is controlled at four adjustable levels that are easily entered in
centimetres.
The level sensor cable must not be broken anywhere in order to prevent the
balancing tube that is a part of the cable from being clogged.
High level
Too much water in the pool
When this level is reached:
1. The circulating pump starts
2. If the automatic filter backwash is enabled,
one filter backwash cycle starts.
Level OK
Filling stops
Filling ON
Level at which pool filling starts
Filling starts after one minute during which the level is permanently below
this value in order to prevent oscillating
Low level
The circulating pump as well as heating will be disabled
Maximum filling time
The maximum filling time acts as protection for case of any failure of the level
measuring. This function will switch o the pool filling after the adjusted time
has elapsed regardless of a level sensor signal.
ASIN AQUA should be switched off during the filling.
This functionis implemented in ASIN Pool Eletrical Box.

EN
18
Automatic Filter Backwash
The automatic backwash function ensures the filter backwash on a regular
basis in the preset intervals. To enable this function is necessary to use the
automatic 5-way BESGO valve. Its moving controlled by the relay switching
on/o. When the relay switches on, the BESGO valve is activated and moved
to the required position by the action of pressure water or air. See the
BESGO manual.
ASIN AQUA should be switched off during the backwash.
Flow control
Overflow/Bottom
To use this function, it is necessary to install the 3-way BESGO
switchingvalve. It is possible to make a decision whether water shall
circulate through the overflow or the bottom drainage.

EN 19
Solar
The ASIN Pool allows control of the solar heating. To enable this function
itisnecessary to install the outdoor thermometer to the solar collector.
At the preset temperature of the solar collector, e.g. 40°C, solar system
circulating pump as well as the filter pump will start on. This start takes
absolute priority over other settings in order to prevent the solar collector
from being overheated.
Variable speed Pump Control
The ASIN Pool with the additional VS Pump module enable to control the
power of circulating pumps with a variable drive. Power can be selected
at preset periods in individual modes. In case of backwashing, the pump
isrunning at speed HIGH. Individual speeds LOW, MEDIUM, HIGH are
adjusted directly on the pump according to the respective pump manual.
In case of use of pool cover the pump can slow down to speed LOW if pool
cover isclosed.

EN
20
Relay settings (lights/cover)
Optional relay settings, switch between lights control and pool cover control.
Calibration
Allows more accurate measurement of probes and sensors by assigning
them measured values by certified meters.
Other manuals for ASIN Pool
1
Table of contents
Other Aseko Controllers manuals