ASG PS-55 Quick start guide

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
PS-55, PS-55C, PS-110
Power Supply Operaonal Manual
Important: Please read and save the operang instrucons.
Danger: To reduce the risk of re or electric shock, carefully follow these instrucons.
Storage, Operaon, Set-Up
1. Be sure that the power source is equipped with a circuit breaker.
2. Store the power pack in a place free from excessive humidity, temperature, and dust. Keep
it away from metallic objects.
3. Do not place objects on the unit.
4. Use the ngs provided to secure the unit. The installaon area should be vibraon free.
5. Do not store the unit next to high voltage equipment.
Cauon
1. Do not drop the power supply.
2. Connect to a power source of only the specied voltage.
3. Only use compable screwdrivers with the power supply.
4. Do not drag the unit by its power cord. Keep the cord away from foreign objects, oil, and sharp
implements.
5. Grasp the plug when disconnecng the power cord.
6. Do not disassemble or modify the unit.
7. If the unit overheats, acvates a circuit breaker, or exhibits other abnormalies, stop operaon
immediately, unplug the unit, and contact ASG for repair.
8. When the unit is not in use, turn the power switch o and disconnect it from its power source.
9. For connecon to a supply not in the USA, use an aachment plug adapter of the proper
conguraon for the power outlet.
10. Install a leakage breaker and safety breaker on the input power source and connect the ground
to use the unit.
11. Do not use if the AC cord is cut, frayed, or abraded.
Specicaons
Compable Screwdrivers
Power Supply For use with Compable Screwdrivers
PS-55C 1 screwdriver BL-2000 CL-2000 CL-3000 CL-4000 SS-3000 SS-4000 TL-3000
PS-55 1 screwdriver BL-2000 BL-5000 CL-2000 CL-3000 CL-4000 A-4500 A-5000 CL-6000 CL-6500
TL-3000 TL-6500 SS-3000 SS-4000 SS-6500 SSCR-3000 SSCR-4000 SSCR-6500
PS-110 2 screwdrivers BL-2000 BL-5000 CL-2000 CL-3000 CL-4000 A-4500 A-5000 CL-6000 CL-6500
TL-3000 TL-6500 SS-3000 SS-4000 SS-6500 SSCR-3000 SSCR-4000 SSCR-6500
The PS-55C has a reduced output capacity and will not properly operate tools other than
the tools listed. You would not be able to achieve full performance on tools not listed. While
CL-7000, BL-7000 SS-7000 and A-6500 series tools will operate using the PS-55, PS-55 SS and
PS-110 you my not be able to achieve full performance or the maximum rated torque output
of these tools. Please contact ASG with any quesons regarding screwdriver/power supply
compability.
Model Number PS-55 PS-110 PS-55C
Input Voltage 110-115 VAC 2A/ 220-230 VAC 1A 110-115 VAC 2A
Output Amp 2.5 1.5
Output Voltage 20-30 DC 20-30 DC
Size 7.1 x 3.5 x 4 in
180.3 x 88.9 x 101.6 mm
4.1 x 2.4 x 2.4 in.
104.14 x 61 x 61 mm
Weight 6.5lb (2.9 kg) 2.2 lb (1 kg)
AC Cord Length 6 . (1.8m) detachable 3 . (0.9m)

ASG, Division of Jergens, Inc.
15700 S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
PS-55, PS-55C, PS-110
Power Supply Operaonal Manual
Front View of PS-55C
The PS-55 C is a smaller lighter power supply enclosed in a plasc case.
It has a lower output which is why it can only be used properly with
the smaller lighter torque drivers.
Front View of PS-55 and PS-110
The ON / OFF switch will illuminate when the switch is turned to the ON posion. The HIGH/
LOW switch will change the DC output voltage from 30 VDC to 20VDC. The PS-110 can
power 2 drivers at the same me. NOTE: while the PS-110 unit can power two screwdrivers
simultaneously both drivers will operate at the same speed seng as determined by the
posion of the HIGH/LOW switch.
CE Approval
The PS-55 and PS-110 carry the CE approval. The PS-55C does not, but is double insulated for
electrical safety and uses the same PC board assembly as the PS-55. The PS-55C does provide a
ground path through the 3rd pin on the plug.
Rear View of PS-55 and PS-110
• The PS-55 can operate either on 110-115 VAC or
220-230 VAC by selecng the desired voltage on
the slide switch located on the back of the units.
NOTE: 220 VAC opon not available on PS-110.
• Only the PS-55 is designed to connect to the STC-02
Screw Counter, ASG # 65646.
• Oponal cable, #65705 is available to connect the
PS-55 to a PLC or other equipment to provide a
momentary dry contact / relay closure signal when
the clutch shuts o.
Cord, Fuse, Circuit Breaker
• The PS-55 and PS-110 all have a detachable IEC style
AC cord. The AC cord supplied with the units have the
correct style plug for operang in the US. If you are
using the unit on 220-230 VAC, or outside the US where
a dierent style connector is needed, these can be
acquired locally.
• All units have an internal circuit breaker protecng the
DC output. If the breaker opens, turn the power o and
wait a few minutes to allow the circuit breaker to reset.
If the breaker is connually opening it could mean
you have a problem with the tool or the tool power
cord, the power supply or have selected the wrong
screwdriver or power supply for the applicaon. Contact ASG.
• The AC FUSE on the PS-55 and PS-110 is located in the IEC connector on the back of the
units along with a spare fuse. The spare fuse is located in the rear “pocket” of the fuse
holder. The part # for the replacement fuse is # 720318, or use a GMA-2R Bussman 2
Amp fuse or equivalent. NOTE: The PS-55C has a hard wired cord and can be operated on
110-115 VAC ONLY. The PS-55C AC FUSE is inside the case and is not recommended to be
replaced by the user.