Spellman’s SL150kV rack mount high voltage power sup-
ply is designed for scientific and industrial OEM applica-
tions requiring 150kV at 1200 watts in a compact cable
connected standard sized rack. Models are available in
positive, negative or reversible polarity. The SL150kV is
fully arc and short circuit protected. Excellent regulation
specifications are provided along with outstanding stability
performance. The vacuum encapsulated high voltage
output section assures reliable corona free operation by
eliminating any concerns due to environmental factors.
T PICAL APPLICATIONS
Electrostatics
HiPot Testing
Semiconductor Processing
Capacitor Charging
OPTIONS
200 200Vac Input Voltage
AOL Adjustable Overload Trip
APT Adjustable Power Trip
AT Arc Trip
BFP Blank Front Panel
CPC Constant Power Control
DPM4 4.5 Digit Panel Meters
EFR External Fault Relay
LL(X) Non-Standard HV Cable Length
(10 standard)
NAD No Arc Detect
NSS No Slow Start
RFR Remote Fault Reset
SS(X) Non-Standard Slow Start
(6 seconds standard)
•CABLE CONNECTED 150kV @ 1200W POWER SUPPLY
•REQUIRES ONLY 8.75˝ 5U) PANEL HEIGHT
•EXTENSIVE ANALOG INTERFACE
•ARC QUENCH/ARC COUNT/ARC TRIP
•COMPREHENSIVE DIGITAL FAULT DIAGNOSTICS
SPECIFICATIONS
Front Panel Controls:
Front Panel Controls Power ON/OFF switch, HV ON
Switch, HV OFF Switch with preset feature, 3.5 digit
backlight digital meters for display of output voltage
and output current,10 turn locking potentiometers with
counting dials for adjustment of both output voltage
and output current.
Front Panel Indicators:
HV ON High Voltage Inhibit
HV OFF Over Current
Voltage Control Mode Over Voltage
Current Control Mode Arc
Interlock Open Regulation Error
Interlock Closed Overtemperature
Input:
220Vac ±10%, 50/60 Hertz
Output Voltage:
0 to 150kV
Output Polarity:
Positive, negative or reversible specify at time of order
Output Current:
8mA
Output Power:
1200W
Voltage Regulation:
Load: 0.01% of rated voltage for a full load change
Line: ±0.01% of rated current over specified input
voltage range
Current Regulation:
Load: 0.01% of rated current ±100µA for full voltage change.
Line: ±0.01% of rated current over specified input
voltage range
Ripple:
0.1% peak to peak of maximum output
Temperature Coefficient:
100ppm/°C.
Stability:
100ppm/hr after a 2 hour warm up, for both voltage and
current regulation
PAGE 1 OF 2
SPELLMAN HIGH VOLTAGE ELECT ONICS CO PO ATION
SL150kV
1200W
POWER SUPPLY
www.spellmanhv.com/manuals/SL150KV
Corporate Headquarters
Hauppauge, New York USA
+1-631-630-3000 FAX: +1-631-435-1620
e-ma l: sales@spellmanhv.com
www.spellmanhv.com 128062-001 EV. F
Spellman H gh Voltage s an ISO 9001:2008 and ISO 14001:2004 reg stered company
For locat ons worldw de

SL1200
18.12 [460.24]
17.25[438.15]
JB4
J1
17.00 [431.8 ]
R13TYP
8.72[221.48]
0.44
[11.17]1.48 [37.59]
FRONT VIEW
BACK VIEW
TOPVIEW
19.00 [482.60]
5.75 [146.05]
SL150 ANALOG INTERFACE—
JB4 25 PIN MALE D CONNECTOR
PAGE 2 OF 2
DIMENSIONS: in.[mm]
PIN SIGNAL PARAMETERS
1 Power Supply Common Signal Ground
2 External Inhibit Ground Inhibit, Open HV ON
3 External Interlock +15Vdc @ open, ≤5mA @ closed
4 External Interlock Return Connect to pin 3 to enable supply
5 Current Monitor 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
6 Voltage Monitor 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
7 +10Vdc Reference +10Vdc @ 1mA, maximum
8 Remote Current Program Input 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
9 Local Current Program Output Multi-turn front panel pot for local control capability
10 Remote Voltage Program Input 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
11 Local Voltage Program Output Multi-turn front panel pot for local control capability
12 EFR (Common) External Fault Relay (Optional)
13
EFR (Normally Open) External Fault Relay (Optional)
14 Local HV OFF OUT +15Vdc @ open, <25mA @ closed, connect to
HV OFF for front panel operation
15 HV OFF Connect to HV OFF OUT for front panel operation
16 Remote HV ON +15Vdc @ 10mA maximum HV OFF
17 Remote HV OFF Indicator 0 HV ON, +15Vdc @ 10mA maximum HV OFF
18 Remote HV ON Indicator 0 HV OFF, +15Vdc @ 10mA maximum HV ON
19 Remote Voltage Mode Open collector 50Vdc @ 10mA maximum, ON Active
20 Remote Current Mode Open collector 50Vdc @ 10mA maximum, ON Active
21 Remote Power Mode Open collector 50Vdc @ 10mA maximum, ON Active
22 Power Supply Fault Open collector, 50Vdc @ 10mA maximum
23 +15Vdc Output +15Vdc @ 100mA, maximum
24 Power Supply Ground Signal Ground
25 Shield Return Chassis Ground
Operating Temperature:
0 to 40°C operating
Storage Temperature:
-40 to +85°C storage
Humidity:
20% to 85%, non-condensing
Input Line Connector:
3 conductor 12 AWG 6 ft (1.83m) cable, permanently attached
Output Connector:
A detachable 10 ft (3.05m) shielded HV cable is provided
Cooling:
Forced Air
Dimensions:
8.75”H x 19”W x 22”D rack mount.
(22.23cm x 48.26cm x 55.88cm)
Weight:
89 pounds (40.4kg)
Regulatory Approvals:
Compliant to 2004/108/EC, the EMC Directive
and 2006/95/EC, the Low Voltage Directive.
Specify “P” for positive polarity or “N” for negative polarity, and PN = reversible as
illustrated below.
Sample Model Number: SL150P1200/BFP/LL(20)
Where SL = power supply series, 150 = maximum output voltage in kV,
P = positive output polarity, 1200 = maximum output power (watts), BFP = Blank
Front Panel, LL(20) = 20 foot HV cable.
SPELLMAN HIGH VOLTAGE ELECT ONICS CO PO ATION
SL150kV
1200W
POWER SUPPLY
Corporate Headquarters
Hauppauge, New York USA
+1-631-630-3000 FAX: +1-631-435-1620
e-ma l: sales@spellmanhv.com
www.spellmanhv.com 128062-001 EV. F
Spellman H gh Voltage s an ISO 9001:2008 and ISO 14001:2004 reg stered company
For locat ons worldw de

IMPORTANT SAFETY PRECAUTIONS
SAFETY
THIS POWER SUPPLY GENERATES VOLTAGES THAT ARE DANGEROUS AND MAY BE FATAL.
OBSERVE EXTREME CAUTION WHEN WORKING WITH THIS EQUIPMENT.
High voltage power supplies must always be grounded.
Do not touch connections unless the equipment is off and the
Capacitance of both the load and power supply is discharged.
Allow five minutes for discharge of internal capacitance of the power supply.
Do not ground yourself or work under wet or damp conditions.
SERVICING SAFETY
.
Maintenance may require removing the instrument cover with the power on.
Servicing should be done by qualified personnel aware of the electrical hazards.
WARNING note in the text call attention to hazards in operation of these units
that could lead to possible injury or death.
CAUTION notes in the text indicate procedures to be followed to avoid possible
damage to equipment.
Copyright ©2000, Spellman High Voltage Electronics Corporation. All Rights Reserved.
This information contained in this publication is derived in part from proprietary and patent data. This information has
been prepared for the express purpose of assisting operating and maintenance personnel in the efficient use of the
model described herein, and publication of this information does not convey any right to reproduce it or to use it for
any purpose other than in connection with installation, operation, and maintenance of the equipment described.
118004-001 REV. B

SL150 MANUAL I 118093-001 REV B
Table of Contents
PAGE
1. INTRODUCTION
1.1 Description of the SL150.....................................................................................1
1.2 Standard Features.................................................................................................2
1.2.1 Remote Operating Features ..................................................................2
1.2.2 System Status and Fault Diagnostic Display........................................2
1.3 Options.................................................................................................................3
1.4 Interpreting the Model Number...........................................................................4
2. INSPECTION & INSTALLATION
2.1 Initial Inspection..................................................................................................5
2.2 Mechanical Installation........................................................................................5
3. OPERATING INSTRUCTIONS
3.1 Operation .............................................................................................................7
3.2 Standard Features.................................................................................................8
4. PRINCIPLES OF OPERATION
4.1 Chassis .................................................................................................................17
4.2 High Voltage Transformer...................................................................................18
4.3 High Voltage Assembly.......................................................................................18
4.4 Control/Power PWB ............................................................................................18
4.5 Front Panel Assembly..........................................................................................18
4.6 Options.................................................................................................................18
5. OPTIONS
5.1 Adjustable Overload Trip ....................................................................................19
5.2 200Vac Single Phase Input .................................................................................19
5.3 No Slow Start ......................................................................................................19
5.4 Non-Standard Slow Start.....................................................................................19
5.5 Extra Length Output Cable..................................................................................19
5.6 Arc Trip Option ...................................................................................................19
5.7 Reversible Polarity Option...................................................................................19
5.8 Adjustable Power Trip/Constant Power Control.................................................19
5.9 External Fault Relay Option................................................................................20
5.10 NAD Option.........................................................................................................20
5.11 RFR Option..........................................................................................................20
5.12 Custom Design Models........................................................................................20
Table of contents
Popular Power Supply manuals by other brands

Videx
Videx 520MR Installation instruction

Poppstar
Poppstar 1008821 Instructions for use

TDK-Lambda
TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda
TDK-Lambda 500A instruction manual

Calira
Calira EVS 17/07-DS/IU operating instructions

Monacor
Monacor PS-12CCD instruction manual