ASM NMG2 User manual

Installation and operation manual EN
NMG2®
Stop-Time Measuring System
Please read carefully before installation and operation!
The Instruction Manual for posiwire®sensors must be considered!

© ASM Automation Sensorik Messtechnik GmbH, 2019
All rights reserved.
Am Bleichbach 18 - 24
85452 Moosinning
Germany

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
3
1Safety instructions ........................................................................................................ 4
1.1 Signal words and symbols .............................................................................................................4
1.2 General safety instructions.............................................................................................................5
1.3 Intended use...................................................................................................................................5
1.4 Safety instructions for the use of posiwire®Cable Extension Position Sensors............................6
2Transport and storage................................................................................................... 7
3Installation and initial operation ................................................................................... 8
3.1 Electrical connection ....................................................................................................................10
3.2 Initial operation.............................................................................................................................11
4Operation ...................................................................................................................... 12
4.1 NMG2 basic settings....................................................................................................................16
4.2 Input of a Protocol ID (machine number).....................................................................................17
4.3 Stop-Time Measurement..............................................................................................................18
4.4 Velocity Measurement..................................................................................................................19
4.5 Printer protocol.............................................................................................................................20
4.6 Calculation of the Safety Distance...............................................................................................23
4.7 Option Friction Wheel with encoder.............................................................................................24
4.8 Actuator Option ............................................................................................................................25
4.9 Interface RS-232- / PC connection via USB/RS232....................................................................25
4.10 Option Printer...............................................................................................................................26
4.11 Error numbers ..............................................................................................................................27
5Maintenance and disposal .......................................................................................... 28
5.1 Maintenance and repair ...............................................................................................................28
5.2 Disposal........................................................................................................................................28

NMG2®
Stop-Time Measuring System
4
Version 3.0.0
www.asm-sensor.com
Pos: 6/ Bedienungsanleit ungen/Module Universal/Ü berschriften/Sicher heitshinweise UE @ 6\mod _1507630884828_78. docx @ 48429 @ 1@ 1
1 Safety instructions
Pos: 7/ Sicherheitshi nweise/Signalwört eru nd Symbole UE @ 1\m od_140014046 7807_78.docx @ 9166 @ 2 @1
1.1 Signal words and symbols
Pos: 8/ Sicherheitshin weise/Signalwörter @ 1\mod_1 400240492762_7 8.docx@ 9 385 @ @ 1
WARNING, Risk of Injury:
Indicates a potentially hazardous situation, which, if not avoided, can result in serious
injury or property damage.
WARNING, Risk of Personal Injury or Death:
Indicates a situation that can result in serious personal injury or death if not properly
avoided.
WARNING, Risk of Personal Injury or Death:
Indicates a situation that can result in moderate personal injury or death if not properly
avoided.
WARNING, Risk of Personal Injury:
Indicates a situation that can result in minor personal injury if not properly avoided.
WARNING, Risk of Property Damage:
Indicates a situation that can result in minor to major property damage if not properly
avoided.
Product liability
•Disregarding the following instructions may result in malfunction, damage to property and personal injury
and releases the manufacturer from product liability.
Safety regulations
•National safety regulations must be observed!
Pos: 9/ ######### ##S eitenumbruch ##### ########### ############## ##### @ 0\mod_135 3584168894_0. docx@ 336 @ @ 1

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
5
Pos: 10 /Sicherheitshinweis e/Allg_Sicherheitshi nweiseU E @ 0\mod_13853 98033298_78.doc x@ 261 0@ 2 @ 1
1.2 General safety instructions
Pos: 11 /Sicherheits hinweise/Sicherheits hinweise_NMG 2 @ 7\mod_154393 0800167_78.doc x@ 60275 @ @ 1
Risk of injury by the machine to be measured
•Use the stop-time measuring system only in such a way that in the case of
malfunction or failure no person can be injured and no machine can be damaged.
•Do not override the safety devices of the machine.
Danger of electric shock when touching the instrument due to faulty
connection
•Guarantee that the earthing contact of the line socket is on earth potential.
•Do not attach the stop cable under voltage.
Pos: 12 /Sicherheits hinweise/Bestimmu ngsgemäße Verwen dung/Bestimmungsg emäße Ver wendung UE @ 1\mod_1 400142179648_ 78.docx @ 9192 @ 2 @ 1
1.3 Intended use
Pos: 13 /Bedienungs anleitungen/NMG2 /Bestimmungsgem äße Verwendung _NMG2 @ 6\mod_1 510926556222_7 8.docx @ 49607 @ @ 1
The Stop-Time Measuring System NMG2 is intended to measure stop time, stop distance and velocity of
power driven machinery like presses, robots and other machines with user access. For determining
measuring ranges, environmental compatibility and connection data of the sensor, please note the data
sheet. Use the unit as intended by operating within its specified technical data and ambient conditions.
The installation and operating instructions supplied with the unit must be observed. All maintenance and
service work must be carried out. The data sheet of the Stop-Time Measuring System is part of this
instruction manual. If yet not available, please request it.
The Position Sensor posiwire®must not be improperly mounted, operated or serviced. In addition, operation
of the sensor in faulty condition is prohibited.
Pos: 14 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
6
Version 3.0.0
www.asm-sensor.com
Pos: 15 /Bedienungsanl eitungen/NMG2/Sich erh.hinw_WS UE @ 6\mod_1 511861536787_78.doc x@ 4 9985@ 2 @ 1
1.4 Safety instructions for the use of posiwire® Cable Extension
Position Sensors
Pos: 16 /Sicherheitshinweis e/Sicherheitshinw eise_WS @ 8\mod_1557 824287034_78.docx @ 6377 3@ @ 1
Danger of injury to the operator or damage to the property
•Connection to power supply must be performed in accordance with safety
instructions for electrical facilities and performed only by qualified personnel.
•Any alteration, reconstruction or extension of the sensor is not allowed!
•The sensor must be operated only within values specified in the datasheet.
•The danger of personal injury and danger of property damage due to a
malfunction of the sensor in machines or systems must be excluded by
additional safety measures.
•In safety-relevant applications, additional facilities must be provided for
maintaining safety and preventing damage.
•Check whether the protection class of the sensor is suitable for the application.
Risk of crushing and cutting injury due to pre-tensioned spring being released
from housing when opened!
•Do not open the sensor.
Risk of cutting injury due to uncontrolled retraction of the cable
•Do not damage the measuring cable!
•Do not let the measuring cable and the cable fixing spring back uncontrolled!
•Do not exceed the maximum cable extension range!
•Do not bend the measuring cable!
•Do not let the measuring cable be dragged on objects!
Mechanical damage or destruction of the sensor
•Avoid impact and shock to the sensor.
•Do not allow the measuring cable to spring back uncontrolled.
•Do not pull out the measuring cable beyond the range of the sensor.
Malfunction due to the accumulation of dirt on the measuring cable
•Do not oil or lubricate the measuring cable.
Pos: 17 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
7
Pos: 18 /Bedienungs anleitungen/Posi wire/Transport und Lag erung @ 6\mod_1 508768821175_7 8.docx @ 49055 @ 1 @ 1
2 Transport and storage
Risk of damage to the measuring cable or cable fixing
•Do not lift the sensor by the cable or cable attachment.
Observe storage and transport temperatures according to the temperatures specified in the data sheet.
Max. rel. humidity 60%, dew condensation must be prevented at all times.
The device must be secured against slipping and tipping during transport.
Pos: 19 /Bedienungs anleitungen/NMG2 /Lieferumfang_NMG 2 @ 6\mod_15 10928950246_78.d ocx @ 49645 @ @ 1
Unpacking
Check the device after delivery for transport damages. Particularly check the switches, control panels and
sockets. If the stop-time measuring system is damaged or if deviations from the specifications contained in
this operation manual can be recognized, contact us immediately.
Shipment damages
Check sensor immediately for shipping damage. In case of any damage, please contact your supplier.
Supplied parts
The stop-time measuring system (dimensions: 425 x 325 x 205 mm)
is suitable as hand luggage for the airplane transport. The cover of
the case may be opened to a maximum angle of 90°. The cover can
be removed in the 45° position.
During transport the sensor must be inserted at the intended
position. Disconnect the cable from sensor. Shipment only in
sufficiently upholstered packing!
•Stop-Time Measuring System NMG2-X in a transportation case ‒complete equipment see data sheet
•Position Sensor ‒sensor type see data sheet
•Sensor connector cable WS-KABEL-5M-NMG
•Mains cable NMG2-NETZANSCHLUSSKABEL
•Stop cable NMG-STOPKABEL
•Magnetic clamp MAG1
•Operation manual NMG2
•Operation manual posiwire®
•Keys, 2 pieces
•Spare fuses, 2 pieces: 1 AT, 5 AT
Pos: 20 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
8
Version 3.0.0
www.asm-sensor.com
Pos: 21 /Bedienungs anleitungen/Mo duleU niversal/Überschrift en/Montage, In betriebnahme UE @ 4\ mod_149147469 4256_78.doc x@ 38 324 @ 1 @1
3 Installation and initial operation
Pos: 22 /Bedienungs anleitungen/NMG2 /Funktionsbeschr eibung @ 6\mod_1 511174581645 _78.docx @ 49691 @ @ 1
Description
The NMG2 perform safety-related measurements of power driven machinery like presses, shears, welders,
riveters and robots. In accordance with national and international safety standards machines with dangerous
movements have to be equipped with protection devices. The improper placement of a protection device
(2-hand control, safety light curtain and so on) will result in the potential for injury of the operator. With the
NMG2 all the important measurement values such as stop-time, stop-distance and velocity are provided to
calculate the minimum safety distance. The safety distance is defined in national and international standards
EN ISO 13855 (EN999). To ensure maximum safety the stop-time measurements have to be repeated
periodically (6 months).
The measuring cable of the posiwire®Position Sensor will be connected to the moving part of the machine
with the magnetic clamp or a fixing screw. The Sensor sends an incremental pulse signal to the
microprocessor controlled counter. The stop position can be selected by a digital encoder. The operator will
adjust the stop position of the measurement to the position of max. velocity of the moving part of the
machine.
To determine this max. velocity NMG2 provides the following measurement functions:
•Measurement of the max. velocity within the complete movement
•Measurement of the velocity at the stop position
•Measurement of the position of the max. velocity
If the position signal passes through the determined stop position in the selected direction a galvanic isolated
contact will cause the stop of the machine and the stop-time measurement will be started. The position
measurement values will be recorded until the machine has stopped completely. The two displays of the
measuring device will show the measurement values of stop-time and distance. By pressing a button the
velocity at the stop position can be displayed. A measurement protocol will be printed. The NMG2 electronics
ensures that the measurement is started only at the adjusted stop position and only in the selected direction
of motion.
The NMG2 can be used as a comfortable position and velocity measurement system in different
applications. The measurement values can be transmitted to a PC or a Laptop via the RS-232 interface and
processed with any software. Additional an actuator can be controlled to interrupt a safety light curtain, so
that it is not necessary to insert the relay contact into the machine circuit.
Pos: 23 /Bedienungs anleitungen/NMG2 /Besondere Eige nschaften @ 6\mod_ 1511174217915_ 78.docx @ 49685 @ @ 1
Special Characteristics
•Easy to use
•Portable and solid equipment
•Built-in matrix printer (option)
•Built-in RS-232 interface
•Fast set-up time
•Traceability of measurement values
•ISO9000 Calibration certificate
•Adjustable stop point
•Standstill detection down to v < 1 mm/s
•Measurement of max. velocity
•Measurement of velocity at stop point
•Measurement of rotary tables
Pos: 24 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
9
Pos: 25 /Bedienungs anleitungen/NMG2 /Technische Daten @ 6\mod_15109 29723823_78.d ocx @ 49656 @ @ 1
Specifications
Measurement function Stop-Time
Measurement range
0 ... 5000 ms
Resolution
1 ms
Accuracy of time base
0.5 ms -0.05 %
Stability of time base
±50 ppm / K
Relay compensation
Time delay of release contact will be compensated at every measurement
Standstill detection
v < 1 ... 10 mm/s; default: 10 mm/s
Measurement function: Position
Measurement range
-2500 ... +2500 mm (standard)
-9999 ... +9999 mm (maximum) measurement ranges of sensor up to
30000 mm
Determination of stop point
-9999 ... +9999 mm
Resolution of measuring
device
up to 0.1 mm
Resolution of sensor
25 µm
Accuracy
±0.05 % f.s. ± 1 digit
Influence of temperature
±0.005 % f.s. / K
Measurement function: Velocity
Measurement range
-9999 ... +9999 mm/s
Resolution
2.5 mm/s
Accuracy
±2.5 mm/s
General specifications
Displays
2 x 4-digit LED with sign
Trigger output
Logic signal 5 V, High Low at stop point
Stop contact
NC / NO 230 V AC / 5 A
Fuse protection of stop circuit
5 A slow-blow
Supply voltage
100 ... 240 V AC, 50/60 Hz
Power consumption
30 W max.
Fuse protection mains
1 A slow-blow
Dimensions
425 mm x 325 mm x 205 mm
Weight
10.5 kg incl. case
Operating temperature
0 °C to 40 °C
Humidity
80 % R.H. max., non-condensing
EMC
EN 61326-1:2006
Options
(further options see
data sheet NMG2)
Built-in matrix printer NMG2-2500-P
Measurement ranges from 1250 to 30000 mm
Actuator to release no-touch safety equipment
USB/RS-232 cable and PC software
Adjustable standstill detection
Pos: 26 /Bedienungsanl eitungen/NMG2/Ele ktrischer Anschluss_NMG2 @ 7\ mod_154393172 4207_78.docx @ 60280 @ 2 @ 1

NMG2®
Stop-Time Measuring System
10
Version 3.0.0
www.asm-sensor.com
3.1 Electrical connection
Check before the first operation
•Make sure that supply voltage indicated on the device corresponds with the supply network. Check
likewise the assigned fuse.
•Replace the fuse only with the type indicated in the operation manual.
Grounding link
•Use only plug sockets with mains protection. Guarantee that the earthing contact of the plug socket is
on earth potential.
Danger of electric shock when touching the instrument due to incorrect
connection
•Make sure that the earthing contact of the plug socket is on earth potential.
•Do not connect the stop cable under voltage.
Electrical connection of posiwire® Cable Extension Position Sensors
Damage or destruction of the sensor due to excessive operating voltage or
mounting error
•The applied operating voltage must not exceed the value specified in the data
sheet.
•Operate the sensor only within the limits specified in the data sheet.
•Connect to the power supply only by qualified personnel and in accordance with
the applicable safety regulations for electrical equipment.
•Do not connect or disconnect the sensor under voltage!
Corrosion in the sensor due to moisture penetration
•Use the sensor only according to protection class.
•The mating connector should have the same protection class as the sensor,
otherwise the lower IP rating of the mating connector is valid.
•Avoid crossing the dew point.
•Cable outputs must be installed in such a way that no moisture can get into the
cable.
•The protection class of sensors with connector output is valid only if the electrical
plug is connected!
Damage of the sensor cable due to mechanical stress
•Do not twist the M12/M8 connector inserts.
•It is important that the knurled nuts on the connectors are tightened to the correct
torque for each different size of the connector:
•M8-ASM connectors / couplings: 0.6 Nm
•M12-ASM connectors / couplings: 1.0 Nm
•connectors / couplings of other manufacturers: according to manufacturer
instruction.
•Use a torque wrench.
•Do not strain the connection cable.
•A separate cord grip is recommended.
Pos: 27 /Bedienungsanl eitungen/NMG2/Inbetri ebnahme @ 6\mod_1511 181330520_78.docx @ 49 728@ 2 @ 1

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
11
3.2 Initial operation
Risk of crushing and cutting injury due to the movement of the measuring cable
or to moving machine parts during operation
•Operate the measuring instrument only in such a way that no danger for persons
or machines can occur.
•The measuring cable must not be oiled or lubricated. Do not break the cable!
•Do not let the measuring cable and the cable fixing spring back uncontrolled!
•Do not exceed the maximum cable extension range! (see Instruction Manual for
Cable Extension Position Sensors posiwire®).
•Operate the device only at plug sockets with protective ground.
•Replace fuses only with the type indicated in the operation manual.
•Do not override the safety devices of the machine.
•In the ADJUST mode no stop signal will be released.
Preparation
1. Connect the Stop-Time Measuring System and the posiwire®Cable Extension Position Sensor with the
8-wire sensor cable.
2. The connection of the cable clip to the moving part of the machine to be tested is made with the
magnetic clamp or an eye. Do not let the cable snap back! Note that the applicable force on the magnet
is reduced in the case of tangential force or on coated (paint) or uneven surfaces. Mount the sensor on a
plain base (see figure below). Note that a cable misalignment will cause measurement errors!
3. Make sure that the machine is switched off and connect the stop cable (2 wire) into the safety circuit of
the machine and connect the other end with the stop cable connector [25] of the NMG2.
4. Connect the power supply with the line socket and make sure that the earthing contact of the plug socket
is on earth potential.
5. Switch on the machine.
6. Switch on the Stop-Time Measuring System.
Pos: 28 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
12
Version 3.0.0
www.asm-sensor.com
Pos: 29 /Bedienungsanl eitungen/Module Uni versal/Übersc hriften/Bedienung U E@ 7\ mod_1536677472 767_78.docx @ 58611 @ 1 @ 1
4 Operation
Pos: 30 /Bedienungs anleitungen/NMG2 /Bezeichnung der Bedi enelemente @ 6\ mod_1511175081 559_78.doc x@ 49702 @ @ 1
Controls and Displays

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
13
Identification of Controls and Displays
[1] TEST RUN/ADJUST
This button offers a reset function in the ADJUST position. The values of stop time and stop distance will be
set to zero and the stop contact is in normal position. The machine can be operated and no measurement
will be performed. Measurement will be started in the TEST RUN position only.
[2] RELEASE/OPERATE
This button sets the function of the potential-free stop contact looped into the stop circuit of the machine
(OPERATE or RELEASE). In most cases the RELEASE function is used. This button must be set before
starting measurement!
[3] UP/DOWN
Toggles the measuring direction.
UP = pull out measuring cable = positive counting.
[4] PRINT ON/PRINT OFF
Switches the built in printer on or off.
[5] ZERO
Sets the measuring system to zero.
[6] Velocity measurement (Vmax)
In the VELOCITY MEASUREMENT mode the max. velocity and the corresponding position can be
measured.
[7] The Actuator Option
An actuator to break safety light curtains is available as an option.
[8] Automatic Measurement Mode
In the automatic measuring mode, it is possible to perform any number of measurements without pressing
the key ADJUST/TEST RUN. After each measurement, the stop contact is set to the normal condition
automatically and the machine can be moved. If the machine passes the stop point in the opposite direction
the measurement data will be deleted and the NMG2 is ready for the next test run.
[9] Jog wheel
With the jog wheel the stop position of the stop-time measurement can be set. Example: The moving part of
the machine, e.g. a press, is in the top dead center and the wheel is turned until the stop-point display [18]
shows -500. That means that the measurement will be started 500 mm below the top dead center of the
machine. The result of the measurement will be shown as a negative value because of the downward
movement.
[10] LED Indicators
Assignment of display and shown parameter.
[11] ... [16] Definition of the measurement displays.
[17], [18] Displays 4 digits + sign.
[19] ... [21] Protocol printer

NMG2®
Stop-Time Measuring System
14
Version 3.0.0
www.asm-sensor.com
Connectors

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
15
Identification of connectors
22] Mains connector.
[23] Mains fuse 1 A slow blow.
[24] Mains switch.
[25] Connector for stop cable to be connected into the safety stop circuit of the machine.
[26] Fuse F1 for the stop control circuit, 5 A slow blow.
[27] Connector for the posiwire® Position Sensor or friction wheel encoder, 8 pin DIN socket.
[28] Trigger output
The signal changes its potential from logical 1 to logical 0 (+4,5 V to 0 V DC) if the stop control is released.
The signal can be used to trigger data recorders or other registration devices.
[29] PC connector RS-232
The measurement data can be transmitted to the PC in ASCII format and processed there.
Recommended software: NMG2-RS232/USB-PROSOFT.
[30] Actuator connector
The actuator causes the interruption of light curtains and light barriers.
Pos: 31 /######## ### Seitenumbruch # ############## ############## ###### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
16
Version 3.0.0
www.asm-sensor.com
Pos: 32 /Bedienungs anleitungen/NMG2 /Grundeinstellunge n @ 7\mod_1546 953012858_78.d ocx @ 61435 @ 2 @ 1
4.1 NMG2 basic settings
There are two ways of opening the menu for basic settings:
1. NMG2 switched off: set the button [1] in the ADJUST position, keep the ZERO button [5] pressed ‒the
NMG2 will be switched on.
2. NMG2 switched on: set the button [1] in the ADJUST position, keep the ZERO button [5] pressed and
set the button [1] in the position TEST RUN, then release the ZERO button [5].
Both displays show the message FUNC/END. Turn the jog wheel [9] clockwise until the display shows
FUNC. Select the needed function and press the ZERO [5] button. The set function will be saved; then leave
the display FUNC;END.
Basic setting of the formula parameters
FUNC;END ⇒gr
Turn the jog wheel [9] clockwise until [gr] will appear. Press the ZERO [5] button to achieve the setting mode
for the hand speed, which can be adjusted now with the jog wheel. Then press the ZERO [5] button. Now
FUNC;END appears again.
FUNC;END ⇒t2
Turn the jog wheel [9] clockwise until [t2] will appear. Press the ZERO [5] button to achieve the setting mode
for the addition to the stop time, which can be adjusted now with the jog wheel. Then press the ZERO [5]
button. Now FUNC;END appears again.
FUNC;END F1
Turn the jog wheel [9] clockwise until [F1] will appear. Press the ZERO [5] button to achieve the setting mode
for the proportional addition factor for stop time, which can be adjusted now with the jog wheel. Then press
the ZERO [5] button. Now FUNC;END appears again.
FUNC;END F2
Turn the jog wheel [9] clockwise until [F2] will appear. Press the ZERO [5] button to achieve the setting mode
for the addition to the safety distance, which can be adjusted now with the jog wheel. Then press the ZERO
[5] button. Now FUNC;END appears again.
Number of measurements in automatic mode
FUNC;END n
Push briefly the ZERO button [5] to achieve the setting mode for the number of measurements in automatic
mode, which can be adjusted now with the jog wheel [9]. For n=0 the automatic measurement mode will be
terminated by pressing ADJUST. According to ISO 13855 the preset is n = 10. Then press the ZERO button
[5]. Now FUNC;END appears again.
Selection of the measurement type
FUNC;END Fcod
Push briefly the ZERO button [5] to achieve the setting mode for the selection of the measurement type,
which can be adjusted now with the jog wheel [9]:
•Bi-dir: bidirectional standard measurement mode for measurements on presses etc.
•Uni-dir: unidirectional measurement mode for continuous movements (e.g. conveyors, rotary tables)
•AUto rES: like Uni-dir, but the ZERO button [5] must be pressed for a new measurement NULL [5]
•ES24 for measurements on systems with emergency stop or 2-hand control using the switch
NMG2-KABEL-ES24V
Then press the ZERO button [5]. Now FUNC;END appears again.

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
17
While using first set up method, i.e. when NMG2 is switched off, the following parameters will also be
available:
Realtime clock
FUNC;END FUNC;ddtt
Push briefly the ZERO button [5] to achieve the setting mode:
1. d;31 ⇒set the day (e.g. 31) with the jog wheel [9] and push briefly the ZERO button [5]
2. dd;7 ⇒set the month (e.g. July=7) with the jog wheel and push briefly the ZERO button [5]
3. ddd;19 ⇒set the year (e.g. 19) with the jog wheel and push briefly the ZERO button [5]
4. tt;16 ⇒set the hour (e.g. 16) with the jog wheel and push briefly the ZERO button [5]
5. t;24 ⇒set the minutes (e.g. 24) with the jog wheel and push briefly the ZERO button [5]
When the display shows FUNC;END then push the ZERO button [5] to return to the ADJUST mode..
The NMG2 has a real-time clock with backup battery. During each measuring process the current date and
time are stored. On the printout and via the serial data communication date and time are displayed.
Language selection
FUNC;END LnCo
Push briefly the ZERO button [5] to achieve the setting mode for the language selection, which can be
adjusted now with the jog wheel [9]:
1 German
2 English (mm)
3 English (mm and inch)
Standstill velocity
FUNC;END Stop
Push briefly the ZERO button [5] to achieve the setting mode for the standstill velocity, which can be
adjusted from 1 to 10 (mm/s) with the jog wheel [9]. Default value: 10 mm/s.
Pos: 33 /Bedienungs anleitungen/NMG2 /Eingabe einer Messke nnung @ 6\mo d_151092765793 6_78.docx @ 49628 @ 2 @ 1
4.2 Input of a Protocol ID (machine number)
In the ADJUST mode the user can input a freely selectable 8-digit protocol ID. This protocol ID appears in
the printout and in the RS-232 transmission protocol if not zero.
Procedure
Press the ZERO [5] button in the ADJUST mode. At one display [17,18] three LEDs light up. This display
can be adjusted with the jog wheel [9]. Press ZERO [5] again and hold it, now the second display can be
adjusted.
The upper display [17] shows the first 4 characters and the lower display [18] the last 4 characters of the ID.
Now the protocol ID appears in the printout.
Pos: 34 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
18
Version 3.0.0
www.asm-sensor.com
Pos: 35 /Bedienungsanl eitungen/NMG2/Nachl aufmessung @ 8\mod_1 565177153428_78.doc x@ 6 6676@ 2 @ 1
4.3 Stop-Time Measurement
1. Configuration of the machine
Press the [1] button, “ADJUST” active
2. Set the Stop Contact or the Acutator (Aktor) (see page 25)
Button [2] released: “RELEASE” active; the safety circuit of the machine is closed and will be interrupted
at the Start Position (see 8.).
Button [2] pressed: “OPERATE” active; the safety circuit of the machine is open and will be closed at the
Start Position (see 8.).
3. Select the measuring direction
Button [3] pressed: downward measurement, “DOWN” active, pulling in the measuring cable corresponds
with the DOWN direction and will cause negative counting.
Button [3] released: upward measurement, “UP” active, pulling out the measuring cable corresponds with
the UP direction and will cause positive counting.
4. Set the printer
Button [4] pressed: “PRINT ON”, printer activated
Button [4] released: printer deactivated
5. Set the machine to ZERO
Arrange the machine in the upper or lower dead center and set to zero using the button [5] “ZERO.
6. Activate “Stop-Time measurement” mode
Button [6] released: “STOP TIME” active
7. Set Single/multiple measurement
Button [7] pressed: “Automatic measurement” mode, “MULTIPLE” active
Button [7] released: “SINGLESHOT.”mode active
8. Select the Start Position of the measurement
Adjust the “START POSITION” (lower display) with the jog wheel [9], this is usually the half of the whole
movement.
Button [3] pressed: negative value
Button [3] released: positive value
9. Prepare the machine for the measurement
Button [1] released, Mode “TEST RUN” is active, 4 bars appear on the display.
10. Let the machine perform the complete cycle (e.g. with the 2-hand control).
11. As soon as the moving part of the machine passes the determined stop position the stop contact will
cause the stop of the machine. After the NMG2 has detected the complete standstill of the machine, it
will display the parameters Stop Time and Stop Distance in the upper resp. lower display. The printout
starts, if selected.
In the automatic measuring mode, any number of consecutive measurements can be carried out. The safety
distance measurement will be determined only in this measuring mode.
Pos: 36 /######## ### Seitenumbruch #### ############## ############# #### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
Version 3.0.0
www.asm-sensor.com
19
Pos: 37 /Bedienungsanl eitungen/NMG2/Gesc hwindigkeitsmessu ng@ 6\ mod_151118732 1532_78.docx @ 49755 @ 2 @ 1
4.4 Velocity Measurement
Steps 1 to 5: proceed as in the case of Stop-Time measuring
6. Activate velocity measurement
Button [6] pressed: “VELOCITY” active
7. Set the parameters for the velocity measurement
Button [8] is always released during the velocity measurement, “SINGLESHOT.” active
Adjust the “START POSITION” (start of measurement) with the jog wheel [9]. The recommended value
is +2 mm for upward movement and -2 mm for downward movement.
8. Activate the measuring mode
Now release the button [1], “TEST RUN” is activated, 2 bars appear on the display, NMG2 is ready for
the measurement.
9. Let the machine perform a complete cycle
10. Read the measurement value
After the machine has stopped, press and release the button ZERO [5] to obtain the measurement
values. The max. velocity will be shown on the lower display “MAX. VELOCITY” [18] and the
corresponding position will appear on the upper display “POSITION” [17].
The printout shows the maximum speed between the start position and the complete standstill of the
machine. The actual speed in the start position also appears on the printout, so that the speed at each point
of the stroke can be determined by adjusting the start position.
Pos: 38 /######## ### Seitenumbruch #### ########### ############## ###### @ 0\mod_13 53584168894_0.d ocx @ 336 @ @ 1

NMG2®
Stop-Time Measuring System
20
Version 3.0.0
www.asm-sensor.com
Pos: 39 /Be dienungsanl eitungen/NMG2 /Protokolle/Dr uckerproto koll @ 6 \mod_15 11263097193 _78.doc x @ 49826 @ 2 @ 1
4.5 Printer protocol
As an option the NMG2 can be equipped with a protocol printer. With the button PRINT ON [4] the printer
can be activated. After a test run the measurement data will be printed. It is possible to print the data after a
measurement or the same printout again by pressing the button [4]. Setting button [1] to ADJUST clears all
measurement data and a printer output is not possible any longer.
The button [21] causes the printer paper feed. During printing a paper feed is not possible. If the printer
output is started, the printing cannot be aborted.
Pos: 40 /Bedienungs anleitungen/NMG2 /Protokolle/Nac hlaufmessung –Einz elmessung @ 6\mod_1511 263186499_78.docx @ 49 832@ @ 1
Protocol Stop Distance Measurement – Single Measurement
→0.
→1.
→2.
→3.
→4.
→5.
→6.
→7.
→8.
→9.
→10.
0. Protocol ID (can be set by the customer, see chapter 4.2 Input of a Protocol ID (machine number) on
page 17).
1. Adjusted measurement start position. At this point the contact will be released and the measurement will
be started.
2. A velocity value lower than indicated will be detected as standstill. This velocity can be programmed by
the manufacturer between 1 ... 10 mm/s. Thus, very slow machines can also be measured. Standard
adjustment ex-factory is 10 mm/s.
3. Adjusted measuring direction
4. Adjustment of relay contact
5. The measured stop time
6. The measured stop distance with a resolution of 0.1 mm
7. Velocity at start point
If the NMG measuring system detects a return movement or an oscillation when the machine is stopped, the
following values will be additionally calculated and printed in single measurement mode :
8. Time to final standstill
9. Position of the final standstill
10. Maximum position achieved in return direction