Asus PureGo User manual

User Manual
E19580
V4 / 2021 November
Fruit and Vegetable Cleanliness Detector

2PureGo User Manual
Copyright © 2021 ASUSTeK COMPUTER INC. All Rights Reserved.
No part of this manual, including the products and software described in it, may be reproduced, transmitted,
transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except
documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK
COMPUTER INC. (“ASUS”).
Product warranty or service will not be extended if: (1) the product is repaired, modified or altered, unless such
repair, modification of alteration is authorized in writing by ASUS; or (2) the serial number of the product is defaced
or missing.
ASUS PROVIDES THIS MANUAL“AS IS”WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE. IN NO EVENT SHALL ASUS, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE
FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF
PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ASUS HAS
BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL
OR PRODUCT.
SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE
ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A
COMMITMENT BY ASUS. ASUS ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES
THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT.
Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of
their respective companies, and are used only for identification or explanation and to the owners’benefit, without
intent to infringe.

3
PureGo User Manual
Contents
Contents ..........................................................................................................3
Safety Precautions........................................................................................4
Product specications ................................................................................5
Getting to know your PureGo..................................................................6
Getting Started..............................................................................................9
Charging your PureGo...........................................................................9
Calibrating your PureGo ....................................................................10
Detecting with the PureGo when washing fruits or
vegetables ..............................................................................................11
Using the APP........................................................................................ 14
Cleaning your PureGo ........................................................................15
Charging dock cleaning and maintenance.................................17
Notices...........................................................................................................18

4PureGo User Manual
Safety Precautions
• This product is a sensor designed specifically to detect the degree of pollutant residue in the
water while you are washing fruits and vegetables.
• This product uses UV light to detect residues. For safety reasons, this product does not
contain any anti-yellowing agents, therefore prolonged exposure to the UV lights it emits
may cause the certain parts of this device to turn yellow after time. This is completely natural
and does not affect the functions of the device, nor cause harm to humans.
• This product uses UV light detection, therefore before opening the bottom cover or cleaning
the device, ensure that the device is powered off or in Standby mode and make sure not
to look directly into the light source. Please seek medical help immediately if you feel
uncomfortable.
Fruit and Vegetable test list
Description
Fruits and Vegetables not
applicable to the test results
(Including but not limited to:)
Rich in phytochemicals (Chlorophyll /
Anthocyanin); colorants are released in large
amounts when washing these fruits and
vegetables. This may affect the test results.
Okinawa Spinach, Red Amaranth,
Strawberry
Rich in phytochemicals or plant spores, which
are released in large quantities when washed
and may affect the test results.
Mushrooms, Cloud Ear Fungus,
Seaweed, Enoki Mushroom
* For the latest Fruits and Vegetables test list please refer to the ASUS website
https://www.asus.com/us/Networking-IoT-Servers/Smart-Home/Smart-kitchen/PureGo-PD100/.

5
PureGo User Manual
Product specifications
Model PD100 / PD100A
Dimensions (L x W x D) 102 x 98 x 47 mm
Weight 180g
Battery capacity 1200mA/h
Charging method Wireless charging
Power input 5V, 2A
Operation time 6 hours (water temperature approximately 25°C)
Operating water
temperature 8°C ~ 35°C
Storage humidity -10°C ~ 50°C, 0% ~ 95% RH
Water resistance rating IOS-6425 / IP67
Bluetooth BLE 5.0
Outer casing material LSR
Inner detection chamber
material PPE

6PureGo User Manual
Getting to know your PureGo
Top view
The status LED indicators and Start/Standby button are located on the top side
of the device, and provide a quick way for you to view battery power, Bluetooth
status, and test results through the different LED colors.
Start/Standby button
Bluetooth indicator
Power indicator
LED ring
NOTE:
• PureGo's revolutionary smart water detection feature makes it so that no buttons have
to be pressed during the detection process; PureGo will automatically begin detection
once it is placed in the water. You can also press the Start/Standby button then begin
using the PureGo when the LED ring starts blinking white.
• If no LEDs light up after a long period of time, the device may be out of power. Place the
device onto the charging dock, then try again after the device is charged.
• Please refer to the following table for the LED descriptions of the Start/Standby button.
Wireless
charging dock
Charger catch pan
PureGo
Inner: Optical detection chamber
Outer: Detachable filter
Activity LED & Start/Standby button

7
PureGo User Manual
Activity LED LED behaviour Description
Bluetooth indicator
Blinking Pairing
Lights up for 5
seconds then turns off Successfully paired
Off Pairing unsuccessful
Power indicator (not
on charging dock)
Red Low power; charge immediately
Red light on button
press
Extremely low power, washing detection
cannot be used; charge immediately
Off No power
LED ring
Power indicator
(on charging dock)
Green Power full
Green (blinking) Power level 10% - 100%
Red (blinking) Power leve below 10%
Off No power
LED ring (under
water)
White (blinking) Detection started
Red (blinking)
Lots of pollutants / impurities detected
in the water, please change the water or
continue washing thoroughly
Orange (blinking)
Medium amount of pollutants / impurities
detected in the water, we recommend
continuing with washing the fruits and
vegetables
Green (blinking)
Low amount of pollutants / impurities
detected in the water; the cleanliness of the
water is close to clean water. You can stop
washing
Blue (blinking) Calibrating
Blue Calibration completed
(continued on the next page)

8PureGo User Manual
Activity LED LED behavior Description
LED ring
LED ring (others)
White (looping) Firmware updating
Red
Error notification. Remove the device from
water then place it back into the water, or
short press the Start button to turn off the
red LED light
Off No changes in status after washing for 40
minutes
Function Start/Standby button
behavior APP mode
Activate washing
detection Short press for 0.5 seconds Start washing session
Stop washing detection
(Standby mode) Short press for 0.5 seconds Stop washing session
Calibration mode Press for 1.5 seconds Trigger calibration mode
Bluetooth pairing Long press for 5 seconds Trigger BLE pairing
Firmware update None Trigger firmware update

9
PureGo User Manual
Getting Started
Charging your PureGo
Please follow the steps below to charge your PureGo
1. Place the PureGo onto the charging dock with the front side facing outwards.
(The side with the ASUS logo is the front side of the PureGo; the side with the
model name and certifications is the rear of the PureGo.)
2. Connect the cable from the charging dock to the USB power adapter.
3. Plug the USB power adapter into a power outlet.
NOTE:
• Ensure to wait until your PureGo is fully charged before using it for the first time. Your
PureGo is fully charged when the LED ring lights up green.
• This device uses a power adapter with a power input of 5V/2A. Ensure to use the
bundled power adapter when charging the PureGo.

10 PureGo User Manual
CAUTION!
• Ensure to follow the calibration tutorial and calibrate when using your PureGo for the
first time.
• You do not need to calibrate after every use, but we recommend calibrating your PureGo
periodically (once every 1 to 3 months, depending on usage frequency) to ensure
detection accuracy.
• We recommend recalibrating when changing usage locations to ensure detection
accuracy.
• There may be slight differences in the water quality of the same area during different
times. We recommend calibrating periodically, or calibrating when the PureGo APP
reminder appears.
CAUTION! To ensure the optical detection chamber is completely immersed in the water,
the belt should be below water level when your PureGo is placed into the water.
To Calibrate your PureGo:
1. Press and hold the Start/Standby button for approximately 1.5 seconds until
the LED ring lights up blue, then place your PureGo into clean water.
2. The LED ring will blink blue during
calibration. When the calibration process is
completed, the LED ring becomes a solid
blue light. The calibration process should
take about 25 seconds.
Calibrating your PureGo
Belt

11
PureGo User Manual
Belt
CAUTION! To ensure the optical detection chamber is completely immersed in the water,
the belt should be below water level when your PureGo is placed into the water.
Detecting with the PureGo when washing fruits or vegetables
PureGo's revolutionary smart water detection feature allows instant detection of
the amount of pollutants in the water once it is placed in the water.
When the LED ring begins blinking orange,
we recommend continuing with
washing the fruits and vegetables, or changing the water and soaking the
fruits and vegetables again. When the LED ring blinks green, the cleanliness of
the water is close to clean water.
NOTE: For more information on the LED descriptions, please refer to the table on page 7.
Recommended washing steps
1. Clean the surface of the leafy parts and dirt from the roots of the fruits and
vegetables using clean water or with a tool.
2. Soak the fruits and vegetables in clean water for approximately 1 minute to
allow agricultural pesticide or other residue such as dust to dissolve in the
water. PureGo's revolutionary smart water detection feature makes it so that
no buttons have to be pressed during the detection process; PureGo will
automatically begin detection once it is placed in the water.

12 PureGo User Manual
5. Remove the inedible parts of your fruits and vegetables.
NOTE: A short press on the Start/Standby button will start/end this session.
3. Continue washing the fruits and vegetables with a small trickle of water to
wash away agricultural pesticide or other residue on the surface of the fruits
and vegetables, while continuing the detection process with the PureGo.
4. The cleanliness is indicated by the LED ring on PureGo:
• Red (blinking): Lots of pollutants / impurities detected in the water, please
change the water or continue washing thoroughly.
• Orange (blinking): Medium amount of pollutants / impurities detected in the
water, we recommend continuing with washing the fruits and vegetables.
• Green (blinking): Low amount of pollutants / impurities detected in the
water; the cleanliness of the water is close to clean water. You can stop washing.

13
PureGo User Manual
Notes when washing fruits and vegetables:
• Please follow the recommended procedures and recommended water temperature (8°C
~ 35°C) when using PureGo to avoid detection abnormalities.
• This device is made to function in clear water. Do not use the device in other non clear
water aqueous solutions such as sodas, tea, or coffee.
• Clear water is the best solution when washing fruits and vegetables. We do not
recommend using commercial fruit and vegetable wash solutions, salt water, baking
soda, or vinegar as it may not be able to remove agricultural pesticide, and may even
prolong the degradation time of the agricultural pesticide, increase the chances of
chemical contamination of the fruits and vegetables, or result in detection abnormalities.
• Take care not to damage the surface of the fruits and vegetables when washing them, as
an excess of phytochemicals in the water may affect the detection accuracy. If you find
damages or bruises on the fruits and vegetables when washing them, we recommend
removing them from the water used for detection and rinsing them each individually.
• This device is used to assist with the washing of common fruits and vegetables. Do not
wash items that may contaminate the water such as tea leaves or herbal medicine.
• Cooked food cannot be used with the detection feature of this device.
• If your LED ring lights up red due to an error while washing the fruits and vegetables,
please refer to the following for help:
- Refer to the PureGo APP for troubleshooting steps
- FAQ on the ASUS website (https://www.asus.com/us/Networking-IoT-Servers/Smart-
Home/Smart-kitchen/PureGo-PD100/)
- Fruit and Vegetable test list in this manual.

14 PureGo User Manual
Using the APP
You may use the device independently, or link it to the PureGo APP for more
detailed information. You can download and install the PureGo APP from Google
Play or App Store, or scan the QR code with your mobile phone.
Android iOS
!"#$%&'!"#$%&(
!"#$%&'()*+,-.
/0123456789:'(
;<=>
?@ABBCDEFG/0H'(&I
J=K-?@ABBCDEFGLMN
OPQRSTUVWX
!""#$%&'
PureGo
Pairing through Bluetooth after downloading the APP:
1. Follow the instructions on the APP and long press the Start/Standby button
located on the top of the device for about 5 seconds until the Bluetooth
indicator lights up blue.
2. PD100 SNXXXX should be displayed on the APP, where XXXX represents the
serial number of your PureGo device.
3. Select the device on your mobile phone to begin pairing. The pairing is
successful if the Bluetooth indicator lights up solid blue.

15
PureGo User Manual
Cleaning your PureGo
Fruit or vegetable remains, or dirt may be stuck to the detection lens or in the
bottom filter cover when washing fruits and vegetables. We recommend cleaning
and recalibrating once every month to ensure an accurate and smooth detection
process.
NOTE: Ensure the PureGo is in Standby Mode before cleaning the PureGo.
Follow the steps below to clean and calibrate your PureGo:
1. Press both sides of the detachable bottom filter cover and remove it from the
PureGo.

16 PureGo User Manual
3. Rinse the bottom filter cover with clean water, then wipe it dry using a soft
cloth and reattach it to the PureGo.
4. After cleaning the PureGo, place the PureGo in clean water. Long press until the
LED ring lights up blue and perform a recalibration to make sure the PureGo
was properly cleaned.
5. The recalibration process is complete once the blue light turns off.
2. Wet a lens cleaning cloth or cotton swab with clean water, and clean both glass
sides of the optical detection chamber.
NOTE: Use clean water to clean your PureGo. Do not use organic solvents (such as oil
removers or alcohol) or detergents.

17
PureGo User Manual
Charging dock cleaning and maintenance
• After using the device, please gently shake to remove excess water inside
the detachable bottom filter, or leave it out to dry for a few minutes. Charge
the device by placing it onto the wireless charging dock once the device is
completely dry.
• The wireless charging dock is not water resistant. Please DO NOT place the
charging dock in water, or wash it under running water. If the surface of the
wireless charging dock is dirty, please use a wet cloth to wipe it clean.
• The wireless charging dock comes with a detachable catch pan, which can hold
up to 10cc of water. Please empty out and clean the catch pan regularly, then
ensure to replace it afterwards.
• If the catch pan overflows, please wipe the surface the charging dock is placed
on dry and ensure the bottom side of the charging dock is dry.

18 PureGo User Manual
Notices
FCC Compliance Information
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with manufacturer’s instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
CAUTION! Any changes or modifications not expressly approved by the grantee of this device
could void the user’s authority to operate the equipment. This device complies with Part 15
of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received
including interference that may cause undesired operation.
RF Exposure Warning
The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment. The
equipment must not be co-located or operating in conjunction with any other antenna or transmitter.

19
PureGo User Manual
Compliance Statement of Innovation, Science and Economic
Development Canada (ISED)
This device complies with Innovation, Science and Economic Development Canada licence exempt
RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
CAN ICES-003(B)/NMB-003(B)
Radio Frequency (RF) Exposure Information
The radiated output power of the Wireless Device is below the Innovation, Science and Economic
Development Canada (ISED) radio frequency exposure limits. The Wireless Device should be used in such
a manner such that the potential for human contact during normal operation is minimized.
This device has also been evaluated and shown compliant with the ISED RF Exposure limits under
portable exposure conditions. (antennas are less than 20 cm of a person's body).
Informations concernant l'exposition aux fréquences radio (RF)
La puissance de sortie rayonnée du dispositif sans fil est inférieure aux limites d'exposition aux
radiofréquences d'Innovation, Sciences et Développement économique Canada (ISED). Le dispositif sans
fil doit être utilisé de manière à minimiser le potentiel de contact humain pendant le fonctionnement
normal.
Cet appareil a également été évalué et montré conforme aux limites d'exposition RF ISED dans des
conditions d'exposition portable. (les antennes mesurent moins de 20 cm du corps d'une personne).
Déclaration de conformitéde Innovation, Sciences et
Développement économique Canada (ISED)
Le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique
Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.
CAN ICES-003(B)/NMB-003(B)

Table of contents