Installation instructions E-SHR series page 4
1 Introduction
These instructions describe the functioning, installation,
use and primary maintenance of ATAG central heating
units for United Kingdom and Ireland. Where necessary
different regulations of each country are separately
described.
These instructions are intended for the use of Corgi
registerd installers or registered Bord Gais installers in
connection ith the installation and putting into operation
of ATAG units. It is advisable to read these instructions
thoroughly, ell in advance of installation. Separate
instructions for use are supplied ith the unit for users of
ATAG central heating units. ATAG is not liable for the
consequences of mistakes or shortcomings hich have
found their ay into the installation instructions or users
manual. Further, ATAG reserves the right to alter its
products ithout prior notification.
When delivering the unit, give the customer
clear instructions concerning its use; present
the customer with the users manual and card.
Each unit is fitted ith an identification plate. Consult the
details on this plate to verify hether the unit is compliant
ith its intended location, e.g.: gas type, po er source
and exhaust classification.
On completion of the installation the installer or
commissioning engineer must fill out and complete the
Benchmark commission section of the boiler log book and
hand to customer or end user for future record keeping. The
Benchmark log book must also be filled out and completed
by the service agent follo ing each service call, and returned
to the customer. A copy of the Benchmark commissioning
certificate must be returned to ATAG Heating UK Ltd / Total
Energy Management Ltd along ith the arranty registration
card to register the appliance for the standard arranty
benefits.
2 Regulations
The follo ing regulations apply to installation of ATAG
central heating units:
Legislation and Regulations.
Gas Safety (Installation and Use). All gas appliances must
by la , be installed by a competent person, eg. Members
of CORGI and in accordance ith the current Gas Safety
Regulation. Failure to install appliance correctly could lead
to prosecution.
In addition to the above regulations this appliance must be
installed in compliance ith the current IEE Regulations, the
Building Standards (Scotland Consolidation) Regulations.
Regulations and bye la s of the Local Water Authority and
the Current Health and Safety Regulation.
Ireland:
- Irish standard 813
- Domestic gas installations
The current, Electricity at Work Regulation must be
complied ith and also be in accordance ith the relevant
and current editions of the British Standards.
The ATAG Premier boiler is a certified appliance and must
not be modified or installed in any ay contrary to this
Installation Manual.
Manufactures instructions must not be taken in any ay
as overriding statutory obligations.
The ATAG Premier is a central heating unit ith an
optional integrated hot ater function. These units must
be connected according to these instructions and all
installation norms in respect of the part of the unit to be
connected.
Observe the follo ing rules of safety:
- All ork on the unit must take place in a dry
environment.
- ATAG units must never be in operation ithout their
housing, except in connection ith maintenance or
adjustments (see Chapter 12 and 13).
- Never allo electrical or electronic components to
come into contact ith ater.
Carry out the follo ing tasks in connection ith
maintenance, etc. to an already-installed unit:
- Shut do n all programmes;
- Close the gas tap;
- Isolate the appliance from the electricity supply;
- Close the stop cock of the units intake connection.
Take note of the follo ing hen maintenance or
adjustments are needed:
- The unit must be able to function during these
activities; for this reason, the units supply voltage,
gas pressure and ater pressure must be
maintained. Ensure that these are not a source of
potential danger during these activities.
Following maintenance or other activities;
always check the installation of all parts
through which gas flows (using leak search
spray).
Following maintenance or other activities,
always replace the housing and secure it with
the screws (5x).