ATELLANI BRID User manual

BRID
User Manual


Please read this manual before use
Please keep this manual in a safe place for future reference
BRID
User Manual
.04
.08
.12
.06
.10
.14
.05
.09
.13
.07
.11
.15
Thank you for choosing Brid
By purchasing BRID, you made the wise decision to improve
the quality of the air you breathe
GENERAL SAFETY INFORMATION
HOW TO SET UP
MEET BRID & COMPONENTS
CARE & MAINTENANCE
CO MODULE & APP
WARNINGS & CAUTIONS
OPERATING MODES
TECHNICAL SPECIFICATIONS
QUICKSTART
HOW TO CLEAN/REPLACE THE
NWF PRE-FILTER
HOW TO CLEAN THE CERAMIC
FILTERS
FAQ

04
BRID is a modular air purifier that uses the exclusive
multi-patented L.E.A.P. technology.
BRID literally vaporizes: VOC, Carbon Monoxide, NOx,
organic odors, formaldehyde, bacteria, mold spores and
more.
BRID has a modular and compact design that makes it the
perfect solution for every indoor environment. By using the
latest nanotechnology, BRID has set a new standard for air
purification devices.
* According to your purchase, this
component may be repeated (BRID XL, XXL)
1. TOP MODULE
2. CERAMIC FILTER*
3. POWER MODULE*
4. BASE MODULE
5. NWF PRE-FILTER
6. PROTECTION GRILL
7. POWER CORD
8. SAFETY ROD
MEET BRID
COMPONENTS
1
3
2
4
5
6
7
8

05
1. UNPACK BRID
Carefully extract BRID and all its components from
the cardboard box. Take extra care when handling
the ceramic filter/s.
2. PLACE FILTER/S
Remove the top module and place the ceramic filter
in the dedicated slot of the power module*. Put the
top module back in place.
* This operation should be repeated for every power module
QUICKSTART
3. SAFETY ROD
You can use the provided safety rod to lock the
different modules to the base. Screw the rod
inserting it in the dedicated hole at the bottom of
the device and tighten it all the way to the cap.
4. CONNECT THE POWER CORD
Insert the power cord into the slot located at the
base of the product. Be sure to insert the plug
completely into the socket. Press the power
button. BRID is ON.

06
BEFORE USING THE DEVICE, READ ALL INSTRUCTIONS AND
CAUTIONARY WARNINGS IN THIS MANUAL.
When using an electrical appliance, basic precautions should always be
taken, including the following:
Stop using BRID if there’s any irregularity,
such as unusual sounds, smells or if it
overheats.
Do not insert foreign objects or your fingers
inside the grill or moving parts. Please
observe extreme caution when using the air
purifier in close proximity to children.
Turn BRID off if you hear abnormal sounds
coming from the fan.
Make sure the cable is fully inserted into the
socket. BRID is for indoor use only.
Do not use BRID on unstable surfaces or
next to precarious objects. This may cause
injuries if it falls over.
Do not obstruct BRID’s fan located inside
the base of the product. It is important not
to block the airflow.
Do not place objects on or near the device
and keep it away from water at all times!
GENERAL SAFETY INFORMATION

07
The following warnings indicate hazards with a medium to
high level of risk which, if not avoided, could result in death
or serious injury.
• Do not damage the power cord or plug
• Do not use if the power cord or plug becomes
damaged, hot or loosely plugged into the socket
• Do not use on voltages over 220-240V or over the
specified ratings for the socket or wiring appliances
• Do not handle the plug or the appliance with wet
hands
• Make sure the plug is fully inserted into the base
• Stop using BRID and unplug it if there are any
abnormalities or malfunctions
• Unplug from socket if not in use for long periods
• Regularly clean and remove the dust from the electric
plug
• When unplugging from the socket, pull from the plug.
The use of an extension cable is not recommended
• Never pull or jerk the plug out of the socket from a
distance
• When cleaning, inspecting or moving the product, be
sure to turn the power off and unplug
• Do not insert objects such as your fingers, or metal
items into the air outlet, filters or openings inside the
body of the device
• Do not disassemble, repair or alter the product
• Do not wet or run water over the product other than
when cleaning the filters
• Do not use chlorine or acidic detergents on filters or
anywhere near BRID
• Do not use in the following locations:
- Unstable surfaces
- Places where there might be leakage or use of oil or
burnable gases
- Places where there are corrosive gases or dust from
metallic objects
- Places with direct heat such as a radiator
• Do not wipe or clean with benzine, thinners or use
harmful chemicals in or on BRID
• Do not allow pets near BRID or its power cord
• Do not obstruct the airflow with laundry, clothing or
any other type of fabric
The following cautions indicate hazards with
a low level of risk which, if not avoided, could
result in minor or moderate injury or damage to
property or furniture.
• Do not sit or lean on the product
• Do not lean on BRID when running
• When moving the product, do not place it
on its side
• Once BRID is switched on, do not move it
• Always carry the appliance by its base
• Turn off the product before unplugging it
• Unplug from the socket when not in use
for extended periods of time
• To avoid tripping hazards, safely coil the
cable
WARNINGS
CAUTIONS

08
For maximum performance and reliability, place BRID at a suitable distance from the wall. Do not obstruct
BRID’s fan located at the base of the product. It is important not to block the airflow.
DO NOT PLACE UNDER A TABLE OR WHERE
THE AIR OUTLET WILL BE BLOCKED
DO NOT PLACE ON UNSTABLE AND SOFT
SURFACES LIKE CARPETS OR RUGS.
DO NOT PLACE BRID BETWEEN LARGE
OBJECTS THAT COULD LIMIT THE AIRFLOW
MORE THAN 120CM FROM CEILING
MORE THAN 30CM FROM THE WALL
FROM THE WALL
MORE THAN 30CM
MORE THAN 10CM
FROM THE WALL
HOW TO SET UP

09
OPERATING MODES
SWITCH BRID ON
Press the power button.
SWITCH MODE (SMART > BOOST > NIGHT)
Pressing the power button while BRID is on.
SWITCH BRID OFF
Press the power button for 2 seconds.
MASTER RESET
Turn BRID on.
Turn BRID off.
Wait 6 seconds.
Keep the power button pressed until lights flash,
release the power button.
DISABLE WIFI
Turn BRID on.
Turn BRID off.
Wait 6 seconds.
Keep the button pressed for approx. 10 seconds,
then release the power button.
Lights flash 3 times
SMART MODE
BRID adjusts its cleaning cycles to the pollution
level of the room thanks to its smart sensors. When
the fan is not in motion BRID’s light will turn on and
off every 5 minutes to let you know the device is
working properly.
BOOST MODE
BRID works at maximum speed for faster cleaning
cycles.
NIGHT MODE
BRID slows down the fan and dims the light. You
can turn the light completely off through BRID’s
App.

10
Caring for your BRID is an important part
of achieving optimal performance.
It’s simple and easy:
CARE AND MAINTENANCE
Before cleaning your unit, make sure to unplug it.
Remove any visible dust from the unit’s surface. Gently wipe with
a clean soft cloth. DO NOT USE the following products: benzine,
thinners, polishing powder or other solvents.

11
Remove the protective grill by gently pressing the
2 clips towards the center.
1
3
2
4
The NWF pre-filter should be cleaned/replaced
according to the level of dust in the room,
approximately once every 3 months or once every
2 months if living with pets.
HOW TO CLEAN/REPLACE THE NWF PRE-FILTER
Remove the NWF pre-filter. Vacuum clean or
wash the prefilter under running water eliminating
all dust. If the NWF pre-filter is extremely dirty,
dispose correctly and substitute it with a new/
unused one.
Vacuum the protective grill eliminating all the dust
until clean.
Insert the NWF pre-filter on the inside of the
protective grill. Insert the protective grill into the
slot positioned on the bottom of the purifier until it
clicks in place.

12
HOW TO CLEAN THE CERAMIC FILTERS
For best results, clean the ceramic filters at least once every 4
months.
Unplug BRID and unscrew the
safety rod if present.
Gently remove the top unit and
disassemble the remaining power
filter modules.
Safely remove the ceramic filter
from the power filter module.
Lay the filter in a bowl filled with
warm water. Let it soak for 30
minutes.
* Wet ceramic filters may have a distinctive smell. It will fade away after 12-24 hours.
Rinse the filter under lukewarm
running water.
Let the filter dry for 12 hours* or
until completely dry. Re-assemble
the filter back in place.
1
4 5 6
2 3

13
TECHNICAL SPECIFICATIONS
DIMENSIONS
BRID BRID XL BRID XXL
25x25x24 cm
9,8x9,8x9,4 in
3,5 kg
(7,7 lb)
27 W
||
||
||
||
||
||
||
||
||
||
||
||
||
||
25x25x28 cm
9,8x9,8x11 in
4,5 kg
(9,9 lb)
46 W
110/220 V - 5.9 V D.C.
50/55 Db
45/50 Db
30/35 Db
50 GHz
every 6/8 months
every 2/4 months
25x25x33 cm
9,8x9,8x33 in
5,5 kg
(12,1 lb)
65 W
WEIGHT
ENERGY
CONSUMPTION*:
* In BOOST Mode
POWER SOURCE
NOISE LEVEL (BOOST)
NOISE LEVEL (SMART)
NOISE LEVEL (NIGHT)
FREQUENCY
CLEANING FREQUENCY
(CERAMIC FILTER)
CLEANING FREQUENCY
(PRE-FILTER)

14
If you purchased the CO Guardian module, your BRID will
come equipped with a Carbon Monoxide sensor and alarm.
If the Carbon Monoxide concentration in your room exceeds
a dangerous level BRID will warn you with a buzzing sound.
You can always monitor the Carbon Monoxide concentration
through BRID’s companion app.
BRID’s CO Guardian module is an extremely useful tool but
in no way substitutes a certified Carbon Monoxide detector.
You can download BRID’s app for free.
The app “BRID AIR” is compatible with iOS and
Android. BRID’s app is available from the App Store
and Google Play.
Main features:
• Wi-Fi connectivity
• Pollution monitoring
• Real-time statistics
• Manual set-up
CO GUARDIAN MODULE
DOWNLOAD THE APP

15
BRID DOESN’T TURN ON
• Is the power plug fully inserted into the base?
• Is the power plug fully inserted into the socket?
• Are the power modules connected correctly?
• Is there a power outage in your area?
• Is the power breaker on?
BRID DOESN’T BLOW AIR
• Did you remove the plastic wrapping from the internal components of BRID?
• Are the power modules connected correctly?
• Is the pre-filter dirty?
• Are you in Smart Mode? Even when not operating, BRID monitors the pollution levels in your
environment
THE FAN MAKES A LOUD NOISE
• Are the filters obstructed in any way?
• Are you in boost mode?
HOW OFTEN SHOULD THE CERAMIC FILTERS BE CLEANED?
• The ceramic filters should be cleaned every 4 to 6 months
• It is recommended to clean the ceramic filters every 3 months or as often as needed if you smoke
indoors or live with smokers and/or pets.
HOW OFTEN SHOULD THE PRE-FILTER BE CLEANED?
• The pre-filter should be cleaned according to the level of dust in the room, approximately every 3
months.
I CAN’T PAIR THE BRID’S APP TO THE DEVICE
• Master reset the device and follow the instructions as indicated on page 9
• Be sure that your router is working on the 2.4 GHz frequency band
• Wifi channels 12 and 13 are not supported
A BAD SMELL WON’T GO AWAY
• BRID can only remove organic odors
• You may need to wash the filters
FAQ

Table of contents
Popular Air Cleaner manuals by other brands

Carrier
Carrier DGAPA 1625 Series Quick start and installation guide

Fellowes
Fellowes AERAMAX PRO AM3 PC quick start guide

Sanuvox
Sanuvox GC S300-G2 Installation, maintenance & operation guide

Healthy Climate Solutions
Healthy Climate Solutions HCC-14-23 installation instructions and home owner's guide

HealthyAir
HealthyAir HA-PAP-G2 owner's manual

Rowenta
Rowenta PURE AIR GENIUS manual

Sharp
Sharp FP-R65CX Operation manual

Honeywell
Honeywell UC100C installation instructions

Honeywell
Honeywell Enviracaire 17005 owner's manual

TOTALINE
TOTALINE Star CG1000 Series Installation & operation manual

Cleanleaf
Cleanleaf CL2500D Series owner's manual

Sharp
Sharp Plasmacluster IG-CH2J Operation manual