ATI Technologies SX160 Reference manual

1936
ATI DI MARIANI SRL - Via E. Mattei, 461 - Industrial Area No. 4 Torre del Moro - 47522 Cesena (FC) - Italy
Tel .: +39 0547 609711 - Fax: +39 0547 609724 - Web: www.atimariani.it - Email: info@atimariani.it
IVA IT 00281090407 - REA 143693
ed 02-2021
GAS STORAGE WATER HEATER
SEALED CHAMBER AND FORCED DRAFT
(type C).
SX160
SX220
SX300
SX400
SX600
SX800
ENG - Manual installation, use and
maintenance.
Original instructions.
Read and follow these instructions before installing the unit.
Always keep on hand this manual during the maintenance phase.
This manual is also available in electronic format and downloadable from the website. www.atimariani.it
feb-21

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
2
Ed 2021-02
SUMMARY
1. GENERAL WARNINGS ................................................................................................................................................................. 3
2. TRANSPORTATION, STORAGE AND RECYCLING ......................................................................................................................... 4
3. CORRECT DISPOSAL OF THIS PRODUCT...................................................................................................................................... 4
4. CONTENT, WEIGHT AND DIMENSIONS OF PACKAGE................................................................................................................. 5
5. CATEGORIES OF APPLIANCE....................................................................................................................................................... 5
6. TECHNICAL DATA........................................................................................................................................................................ 6
7. DESTINATION COUNTRIES AND GAS CATEGORIES..................................................................................................................... 6
8. DIMENSIONS AND EQUIPMENT ................................................................................................................................................. 7
9. DESCRIPTION FUNCTIONAL AND CONSTRUCTION..................................................................................................................... 8
10. COMPONENTS OF THE APPLIANCE ........................................................................................................................................ 9
11. LOCAL REGULATIONS, AND INSTALLATION OF SAFETY ....................................................................................................... 10
12. INSTALLATION...................................................................................................................................................................... 11
13. POSITIONING APPARATUS ................................................................................................................................................... 11
14. INSTALLATION COVER SMOKE EXTRACTION........................................................................................................................ 12
15. EXHAUST FUMES.................................................................................................................................................................. 13
16. HYDRAULIC CONNECTIONS.................................................................................................................................................. 16
17. TRUNK GAS .......................................................................................................................................................................... 17
18. ELECTRICAL CONNECTIONS.................................................................................................................................................. 17
19. IGNITION AND TEMPERATURE CONTROL ............................................................................................................................ 18
20. GAS CHANGE........................................................................................................................................................................ 19
21. WIRING ................................................................................................................................................................................ 21
22. PERIODIC MAINTENANCE .................................................................................................................................................... 22
23. PREVENTION AGAINST FROST.............................................................................................................................................. 22
24. POSSIBLE OPERATING DEFECTS ........................................................................................................................................... 22
25.DIAGNOSTIC TOOL ............................................................................................................................................................... 23
26. VALIDATION OF THE WARRANTY......................................................................................................................................... 23

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
3
Ed 2021-02
1. GENERAL WARNINGS
THIS BOOKLET IS AN INTEGRAL PART OF THE APPLIANCE AND ESSENTIAL AND MUST BE KEPT WITH
CARE IN THE VICINITY OF THE APPLIANCE ITSELF FOR FUTURE CONSULTATION. It CONTAINS
IMPORTANT INFORMATION REGARDING SAFETY, INSTALLATION, OPERATION AND MAINTENANCE.
THE APPLIANCE HAS BEEN BUILT FOR THE PRODUCTION OF HOT WATER: ANY OTHER TYPE OF USE
IS TO BE DEEMED NOT SUITABLE AND DANGEROUS.
THE APPLIANCE SHOULD NOT BE INSTALLED IN DAMP, it MUST BE PRESERVED BY JETS, JETS OF
WATER OR OTHER LIQUIDS TO AVOID TROUBLE TO ELECTRICAL AND THERMAL.
INSTALLATION MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL RESPONSIBLE
FOR COMPLIANCE WITH THE CURRENT SAFETY STANDARDS. INCORRECT INSTALLATION, WITHOUT
FOLLOW THE INSTRUCTIONS GIVEN BY THE MANUFACTURER MAY CAUSE DAMAGE TO PERSONS,
ANIMALS OR THINGS, FOR WHICH THE MANUFACTURER IS NOT RESPONSIBLE.
PARTS OF THE PACKAGING (PLASTIC BAGS, POLYSTYRENE, WOOD, CLIPS, ETC.) MUST NOT BE LEFT
TO THE REACH OF CHILDREN AS DANGEROUS.
THE APPLIANCE CAN BE USED BY CHILDREN AGED LESS THAN 8 YEARS AND PERSONS WITH
REDUCED PHYSICAL, SENSORY OR MENTAL, OR LACK OF EXPERIENCE OR KNOWLEDGE REQUIRED,
PROVIDED UNDER SURVEILLANCE OR AFTER THAT THEY WILL GET ALL INSTRUCTIONS ' SAFE USE OF
THE APPLIANCE AND UNDERSTANDING HAZARDS RELATING TO IT.
CHILDREN SHOULD NOT PLAY WITH THE APPLIANCE.
CLEANING AND MAINTENANCE TO BE PAID BY THE USER MUST NOT BE MADE BY CHILDREN
WITHOUT SUPERVISION.
IF THE APPLIANCE SHOULD BE SOLD OR TRANSFERRED TO ANOTHER OWNER, MAKE SURE THAT
THIS booklet stays with the, SO AS TO BE CONSULTED BY THE NEW OWNER AND / OR INSTALLER.
DO NOT PUT ANY KIND OF PURPOSE OF THE DEVICE. TO AVOID RISK OF DAMAGE DUE TO FROST IN
THE EVENT REQUIRES TO LEAVE THE EQUIPMENT STORED FOR A LONG PERIOD IN AN
ENVIRONMENT NOT HEATED, it IS RECOMMENDED drained completely. THE MANUFACTURER IS
NOT RESPONSIBLE FOR FAILURE OR BROKEN PARTS DUE TO FROST AND RELEASE OF WATER IN THE
SYSTEM.
TO GET THE BEST RESULTS AND RECOGNITION OF WARRANTIES WE RECOMMEND YOU TO FOLLOW
THE INSTRUCTIONS BELOW AND ONLY USE ORIGINAL SPARE PARTS AND KIT PROVIDED BY THE
MANUFACTURER.
MORE APPLIANCES IN THE SAME ROOM FOR A TOTAL THERMAL CAPACITY HIGHER A 35 KW, ARE
HEATING PLANT AND ARE SUBJECT TO THE PROVISION OF THE CIRCULAR # 68 firemen.
And 'ABSOLUTELY NO TAMPERING WITH ANY DEVICE SETTINGS AND FACTORY SEALED BY THE
MANUFACTURER.
THE EQUIPMENT SHOULD BE PERIODICALLY CHECKED AND VERIFIED BY A COMPETENT PERSON
ACCORDING TO THE LAW OF THE COUNTRY WHERE THE UNIT IS INSTALLED.
POSSIBLE REPLACEMENT COMPONENTS OF OPERATIONS TO BE PERFORMED BY AUTHORIZED BY
THE MANUFACTURER.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
4
Ed 2021-02
2. TRANSPORTATION, STORAGE AND RECYCLING
The appliance must be transported and stored dry and protected from frost.
The appliance must be stored, transported and used at a temperature between +10 and +40 ° C and at a humidity
between 40% and 80%.
The appliance must not be handled and / or laid horizontally: it is only and exclusively in the vertical can carry it.
Use, handling, a lift truck or a manual trans pallet. As shown in the figure below, enter the parallel arms of the carriage
in the lower part of the appliance.
Remove the packing 4 by unscrewing the screws at the bottom corners of the appliance, then pull upwards the
packaging for whole, taking care not to damage the appliance.
3. CORRECT DISPOSAL OF THIS PRODUCT
PRODUCT IN COMPLIANCE WITH EU DIRECTIVE 2012/19 / EU-D.Lgs.49 / 2014 pursuant to art.
26 of Legislative Decree 14 March 2014, n. 49 "Implementation of Directive 2012/19 / EU
Waste Electrical and Electronic Equipment (WEEE)" (Applicable in the European Union
countries and countries with separate collection systems)
The marking on the product or its literature indicates that the product should NOT be
disposed of with other household waste at the end of the life cycle. To prevent possible harm
to the environment or human health from uncontrolled waste disposal, the user is
encouraged to separate this from other types of wastes and recycle it responsibly to promote
the sustainable reuse of material resources. Household users should contact either the
retailer where you purchased the product or their local government office, for details on
separate collection and recycling for this type of product. Business users should contact their
supplier and check the terms and conditions of the purchase agreement.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
5
Ed 2021-02
4. CONTENT, WEIGHT AND DIMENSIONS OF PACKAGE
The appliance is delivered packaged in a wooden box with appropriate protection. See table below for size.
Dimensions in mm: mm - Weight in kilograms: Kg
SX160
SX220
SX300
SX400
SX600
SX800
Width
580
780
780
780
980
980
Depth
580
780
780
780
980
980
Height
1850
1410
1760
2110
1800
2100
Weight with
packaging
125
210
260
300
290
335
5. CATEGORIES OF APPLIANCE
These appliances are classified as: "Gas storage water heater."
Classes apparatus (EN 483) TYPE C (see table):
C12 The air intake and evacuation of
the combustion products takes
place by means of a horizontal
coaxial duct or with openings close
enough so that they can be
considered in the same wind
conditions.
C52 The openings of the air intake
duct and evacuation of the
combustion products must be
located in different pressure
conditions.
C32 The air intake and evacuation of
the combustion products takes
place by means of a vertical conduit
coaxial.
C82 The air intake takes place
through a suction terminal while the
evacuation of the combustion
products using a connector to an
individual or collective chimney.
C42 An apparatus connected to a
collective duct system consists of a
duct for combustion air supply and a
conduit for evacuation of the
combustion products. The orifices of
this system are concentric or close
enough to be exposed to wind
conditions comparable.
B52 The evacuation of the
combustion products takes place by
means of a smoke duct outside the
environment. The air intake takes
place in the same environment
where the appliance is installed.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
6
Ed 2021-02
6. TECHNICAL DATA
SX160
SX220
SX300
SX400
SX600
SX800
Classe efficienza sanitaria - efficiency class
B
B
B
B
B
B
Profilo di carico - load profile
XL
XXL
XXL
XXL
XXL
XXL
Capacità nominale serbatoio - tank nominal capacity
l
160
220
300
400
560
740
Efficienza –efficiency
%
95
95
96
97
95
96
Portata termica nominale Q - nominal calorific flow rate QN
kW
13.5
22.0
23.0
23.0
23.0
23.0
Potenza termica nominale P - nominal power output PN
KW
12.8
20.9
22.1
22.3
21.9
22.1
Consumo gas - gas consumption
m3/h
1.4
2.3
2.4
2.4
2.4
2.4
Temperatura fumi –flue gas temperature
°C
75
92
70
64
88
69
CO2 (G20)
%
5.5±1
5.5±0.5
5.5±0.5
5.5±0.5
5.5±0.5
4.5±1
CO2 (G31)
%
6±0.5
6.5±0.5
6±0.5
6±0.5
6±0.5
5±0.5
NOx (G20)
mg/kWh
55
50
50
30
24
5
Pressione di esercizio pressostato –APS operativity pressure
Pa
≥140
≥140
≥140
≥140
≥140
≥140
Apertura pressostato –APS opening pressure
Pa
<110
<110
<110
<110
<110
<110
Pressione max acqua - max water pressure
kPa
600
600
600
600
600
600
ηcombustione - Η combustion
%
95
95
96
97
95
96
ηacqua - H water
%
93
91
90
94
92
93
Grado di protezione –protection level for electrical appliance
IP
20
20
20
20
20
20
Potenza elettrica nominale - nominal electric power
W
51
51
51
51
51
51
Caratteristiche elettriche - Electrical characteristics
V/Hz
230~50
230~50
230~50
230~50
230~50
230~50
7. DESTINATION COUNTRIES AND GAS CATEGORIES
Country (EN ISO 3166-1):
Category:
gas / pressure type (EN 437):
TO THE
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
AT
I2H
G20 - 20 mbar
CH
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
CY
I2H
G20 - 20 mbar
CZ
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
DK
I2H
G20 - 20 mbar
EE
I2H
G20 - 20 mbar
ES
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
FI
I2H
G20 - 20 mbar
GB
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
GR
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
HU
I2H
G20 - 25 mbar; G31 - 37 mbar
IE
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
IT
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
LT
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
LV
I2H
G20 - 20 mbar
MK
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
MT
I2H
G20 - 20 mbar
NO
I2H
G20 - 20 mbar
PT
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
RO
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
SELF
I2H
G20 - 20 mbar
YES
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
SK
I2H, II 2H3P
G20 - 20 mbar; G31 - 37 mbar
TR
I2H, II 2H3P
G20 - 20 mbar

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
7
Ed 2021-02
8. DIMENSIONS AND EQUIPMENT
SX160
SX220
SX300
SX400
SX600
SX800
A HEIGHT APPARATUS
2035
1563
1913
2263
1928
2278
B IN OUT SMOKE
1915
1446
1796
2146
1821
2171
C OUTPUT HOT G 1-1 / 4 "
1743
1278
1628
1978
1639
1989
RECIRCULATION D G 1 "
738
952
952
952
1021
1021
ENTRY AND GAS G ½ "
420
481
481
481
481
481
F INLET
408
404
404
404
404
404
G WIDTH
520
720
720
720
920
920
Dimensions in millimeters: mm

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
8
Ed 2021-02
9. DESCRIPTION FUNCTIONAL AND CONSTRUCTION
The function of this device is to generate hot water through the heat exchange between the combustion products of the burner
and the water present in the storage tank.
The combustion takes place in a completely sealed with respect to the device that contains, by withdrawing the air required for
combustion from the outside and discharging the products of combustion itself always outside.
The sealed combustion chamber, is placed in the lower part of the appliance.
BOILER
E 'it built with a sturdy sheet and ensures a remarkable resistance to pressure. It 'also subjected internally to a cryolite glass
treatment. To allow for the inspection of the inner part and the cleaning is provided a Ø120 flange.
BURNING ROOM
E 'at the bottom of the appliance and contains: the burner manifold, injectors. The chamber is sealed off from the environment
in which the appliance is installed.
COVER SMOKE EXTRACTION
A fan located in the top cap provides both air supply both the evacuation of the combustion products. The cap can be rotated
360 °. In case of abnormal operation of the fan or obstruction of the ducts, a pressure cut off the gas flow to the burner.
KIT EXHAUST FUMES (Required to install the kit provided by the manufacturer)
To be selected from those estimated by the installation requirements. It allows the connection of the combustion chamber with
the outside, to bring the combustion air to the burner and to allow the discharge of the fumes.
INSTRUMENT PANEL
It contains everything you need to control and regulate the normal functioning: regulating thermostat, ignition switch, button
unlock bright, bright operation indicator, thermometer.
MAGNESIUM ANODE
To protect the device from galvanic currents that can corrode the interior of the device, they are installed two magnesium
anodes series, one in the inspection flange and one in the upper part of the appliance.
A. COVER SMOKE
B. KIT EXHAUST FUMES
C. CONTROL PANEL
D. BOILER
E. BURNING ROOM

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
9
Ed 2021-02
10.COMPONENTS OF THE APPLIANCE
A. THERMOMETER
Measure the temperature inside the tank.
B. RED LIGHT BLOCK
Report device lock, to unlock, hold down the button for 3
seconds.
C. SWITCH
It allows switching on and off.
D. LIGHT GREEN POWER
Report proper burner ignition. Comes into operation when
the combustion chamber is fed.
E. SAFETY THERMOSTAT
When the device temperature rises above the maximum
threshold, the safety thermostat comes into operation by
blocking the appliance. To unlock it, unscrew the lid and
hold the button sub-
F. THERMOSTAT
Used to adjust the internal temperature of the tank.
G. AIR PRESSURE
It is used to verify and monitor the correct operation of the
air blower, placed on top of the appliance.
H. CONTROL UNIT
The control unit has the purpose of controlling, handle the
electrical devices and appliance gas.
I. PCB CONNECTIONS
The connection card is used to centralize the user control
devices with the controller interface.
L. GAS VALVE
The gas valve allows to manage and control the gas inlet to
the combustion chamber

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
10
Ed 2021-02
11.LOCAL REGULATIONS, AND INSTALLATION OF SAFETY
LOCAL REGULATIONS
In the installation the local regulations must be observed regarding:
Fire fighters
Gas Company
power Company
Office hygiene and health
SAFETY RULES
Do not perform any cleaning or maintenance work without turning off the water heater and interrupting power supply.
E 'absolutely forbidden to operate the water heater with protection of electrical parts or disassembled safety equipment
excluded. E 'absolutely forbidden to remove or tamper with safety devices.
In case of failure and / or malfunction switch off the appliance, close the gas valve and not groped to repair it but contact an
authorized service center.
In case of fire should be used in powder extinguishants: not direct jets of water directly against the heaters as they may
cause short circuits.
Apply tools and / or equipment manuals and / or electrical proper use, they are in good condition and used properly.
Make sure that ladders and / or any rolling ladders are positioned securely, that are appropriate and that the steps are
intact and not slippery, that they are not moved when someone climbs them and ensure someone supervises.
INSTALLATION INSTRUCTIONS
Make sure, for installation and maintenance work at height (generally with higher altitude to two meters), which are used in
scaffolding standards and the space below is free during the eventual fall of tools and objects.
Make sure that, in case of installation and maintenance, the workplace has adequate hygienic conditions with regard to
lighting, aeration and solidity.
Wear during installation and maintenance, clothing and adequate personal protective equipment.
Do not take any action without a prior assessment of the absence of gas leaks using special detector.
The installer must be enabled in the installation of heating equipment according to the law n. 46 of 05/05/1990 and after
work must issue the CONFORMITY 'DECLARATION to the customer.
The appliance must be connected to a hot water distribution network compatible with its performance and its power. Make
sure the installation site and any systems to which it must connect the device comply with the current regulations.
Since the C-type unit, this unit can be installed in any type of local, without any limitation on aeration conditions and
volume of the room.
Before each installation, maintenance or repair, remove the power supply. Protecting tubes and external connection cables
in such a way as to prevent them from being damaged.
The device is to be installed on the floor surface, leaving a suitable distance from the side walls to allow the gas and water
connections, as well as any maintenance interventions. Furthermore, the appliance must be installed on a solid floor, not
subject to vibration, not uneven or non-planar.
Reseal the openings used to make the readings of the exhaust emission values.
The operations inside the unit must be performed with caution so as to avoid abrupt contact with sharp parts.
Do not take any action without a prior assessment of the absence of an open flame or ignition sources.
If you detect a smell of burning, see the smoke out exit from the apparatus, or is felt strong smell of gas, remove the power
supply, close the gas valve, open the windows and notify the authorized service centers nearest
IN ANY SITUATION AND 'WELL ALWAYS REMEMBER THAT COMMON SENSE IS THE BEST SECURITY AGAINST ANY AND / OR
INJURY.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
11
Ed 2021-02
12.INSTALLATION
OPERATION CARRIED OUT BY A QUALIFIED
Warning! The installation of the residential ventilation system must be performed only by qualified personnel in order to avoid
damage or injury.
Before installing the appliance, ensure that the nominal supply voltage is 220 / 240V - 50 / 60Hz.
Make sure that the electrical system is adapted to deliver, in addition to the operating current required by the unit, also
the necessary current for powering appliances and equipment already in use.
Make the electrical connections in accordance with national laws and regulations.
Upstream of the unit to provide a single-pole switch with a minimum distance of 3.5 mm contacts.
The installation of the device is divided into 6 distinct phases, listed below, to be followed with attention and respecting the
order.
1. Positioning device
2. fume extraction hood Installation
3. Installing flue
4. Water connections
5. Connection gas circuit
6. Electrical connection
You should always make the grounding of the unit. Check that the power cord is in perfect condition. Under no circumstances
must repair the cable, possibly damaged, with tape or clamps. If the power cord is damaged, it must be replaced by service
agent or a similarly qualified person in order to avoid a hazard.
Incorrect installation can cause damage to people and things for which the manufacturer can not be held responsible.
13.POSITIONING APPARATUS
The location of the device must be chosen bearing in mind the maximum length allowed for each type of discharge, gas and
electrical connection. The device has been designed to have the water connections, electrical and gas to the right of the
appliance and the flue above: it is recommended to place the heater in such a way as to facilitate the installation and
maintenance operations.
Since the C-type unit, this unit can be installed in any type of local, without any limitation on aeration conditions and volume of
the room.
Refer to the clearances required as in the figure below.
The front and right of the appliance must be easily accessible, in order to facilitate proper installation and periodic maintenance.
To prevent possible infiltration of water during a thunderstorm, we recommend a slight downward slope of the drain pipe and
air suction.
IMPORTANT: FOLLOW THE EXTENT TO INSTALL NATIONAL STANDARDS.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
12
Ed 2021-02
14.INSTALLATION COVER SMOKE EXTRACTION
The fume hood box, delivered separately, contains:
A. cap in black painted aluminum
B. Fan Group
C. coaxial fitting Ø 60/100 with Flue gas bag fixing screws
Place the fan assembly on the appliance with
the flue gas outlet Ø 60 in the desired direction, and fix
with the screws supplied.
Fix the cable holder bracket in the vertical position
(Use only the supplied screws)
Connect the motor supply cables, position 2 and 3.
Connect the ground cable, position 1.
Connect the two grommets to the pressure taps.
IMPORTANT :
pink eraser: 1 socket (metal)
neutral eraser: socket 2 (plastic)
Place the cap on the device in black aluminum,
centering between 4 spacers specially crafted
Fix the appliance cap with the screws
equipment

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
13
Ed 2021-02
15.EXHAUST FUMES
The installation of the exhaust terminals must comply with the regulations in force.
In any case, any provisions foreseen by municipal, provincial or sectorial regulations must be respected. The flue gases of several
boilers must not be conveyed inside the same flue gas exhaust pipe: each boiler must have its own independent exhaust pipe.
The boiler is supplied as standard without exhaust kit. The following table shows the kits available for this appliance. Use only
the original kits (to be purchased separately depending on the type of exhaust you want to make) supplied by the manufacturer.
SMOKE EXHAUST KIT
COMPOSITION
LIMITS
APPLICATION
AKIT21
Horizontal coaxial drain Ø60 /
100
Material: White aluminum
C1
Min 1m
Max 3m
AKIT22
Split horizontal exhaust Ø80 / 80
Material: White aluminum
C4, C5, C8
Min 1m + 1m
Max 6m + 6m
AKIT23
Vertical coaxial discharge
Ø60 / 100
Material: White aluminum
C3
Max 1m
AKIT24
Vertical coaxial exhaust Ø80 /
125
Material: stainless steel
C3
Min 1m vertical
Max 4m vertical
Min 0m horizontal
Max 1m horizontal
AKIT25
Horizontal single wall drain Ø80
Material: stainless steel
B5
Min 1m horizontal
Max 6m horizontal
AKIT26
Vertical double wall drain Ø80 /
130
Material: stainless steel (inside))
Black painted aluminum (outside)
Insulation: rock wool
B5
Min 1m horizontal
Max 6m horizontal
Min 1m vertical
(including terminal)
Max 5m vertical
(including terminal)

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
14
Ed 2021-02
To increase the drain length it is necessary to purchase the appropriate extensions proposed in the following table. The
maximum supported extension is shown in the previous table. Each curve is equivalent to 1 meter of the total length.
The choice of the type of drain must take into account local and national regulations.
EXHAUST FUMES KIT
DESCRIPTION
CODE
AKIT21
Coaxial horizontal drain Ø60 / 100
Coaxial extension Ø60 / 100 L = 500
AIPC05
Coaxial extension Ø60 / 100 L = 1000
AIPC10
Coaxial bend Ø60 / 100 at 45 °
AICC45
Coaxial bend Ø60 / 100 at 90 °
AICC90
AKIT22
Split horizontal drain Ø80 / 80
Extension Ø80 L = 250
AIPR802
Extension Ø80 L = 500
AIPR805
Extension Ø80 L = 1000
AIPR80
Curve Ø80 at 45 °
AICV804
90 ° bend Ø80
AICV809
AKIT24
Vertical coaxial drain Ø80 / 125
Coaxial bend Ø80 / 125 45 °
AKIT24-01
Coaxial extension Ø80 / 125 L = 500
AKIT24-02
Coaxial extension Ø80 / 125 L = 1000
AKIT24-03
Adjustable wall collar Ø125 Inox
AKIT24-04
Coaxial extension Ø60 / 100 L = 1000
AIPC10
AKIT25
Single wall horizontal drain Ø80
Extension Ø80 L = 500
AKIT25-01
Extension Ø80 L = 1000
AKIT25-02
Curve Ø80 at 45 °
AKIT25-03
90 ° bend Ø80
AKIT25-04
AKIT26
Double wall vertical drain Ø80 / 130
Horizontal extension Ø80 L = 500
AKIT25-01
Horizontal extension Ø80 L = 1000
AKIT25-02
Double wall vertical extension Ø80 / 130 L = 500
AKIT26-01
Double wall vertical extension Ø80 / 130 L = 1000
AKIT26-02
Double wall bend Ø80 / 130 45 °
AKIT26-03
Wall support
AKIT26-04
Make sure you have always guaranteed the mechanical stability of the duct.
The hole, for the passage through the wall of the exhaust and air intake pipe,
must not be concreted: the flue gas exhaust must be free to slide through the
hole so that it can be extracted later.
For this purpose, the wall cover rosettes supplied with the flue gas exhaust kit
can be used to cover the empty space of the hole.
IMPORTANT:
LEAVE A SPACE NOT LESS THAN 30 CM ABOVE THE APPLIANCE TO ALLOW ANY MAINTENANCE INTERVENTION ON THE UPPER
PART.
TO AVOID POSSIBLE WATER INFILTRATION DURING THORMS, WE RECOMMEND A SLIGHT SLOPE DOWNWARDS OF THE AIR
INTAKE AND EXHAUST PIPE.
DIAPHRAGM
For correct operation of the appliance it is mandatory to install the diaphragm A contained in the exhaust kit together with the
additional gasket B on the intake duct.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
15
Ed 2021-02
AKIT21 and AKIT24 diaphragm mounting
AKIT22 diaphragm assembly
According to the model of the appliance and the length of the suction pipe, install the diaphragm shown in the table.
AKIT21
AKIT22
AKIT24
1 m
2 m
3 m
1 m
2 m
3 m
4 m
5 m
6 m
1 m V
1 m H +
1 m V
1 m H +
2 m V
1 m H +
3 m V
1 m H +
4 m V
SX160
Ø84
Ø86
-
Ø40
Ø42
Ø44
Ø44
Ø44
no
Ø82
Ø82
Ø82
Ø82
Ø84
SX220
Ø82
Ø86
-
Ø42
Ø46
Ø46
Ø48
Ø50
no
Ø82
Ø84
Ø84
Ø90
Ø92
SX300
Ø82
Ø86
-
Ø45
Ø45
Ø45
Ø45
Ø45
no
Ø82
Ø84
Ø83
Ø84
Ø84
SX400
-
-
-
Ø48
Ø48
Ø52
Ø56
Ø56
no
no
no
no
no
no
SX600
Ø82
Ø86
-
Ø44
Ø44
Ø44
Ø44
Ø44
no
Ø78
Ø78
Ø80
Ø80
Ø80
SX800
Ø82
Ø82
-
Ø38
Ø38
Ø40
Ø40
Ø50
Ø58
Ø78
Ø80
Ø80
Ø82
Ø82
AKIT25, AKIT26 diaphragm mounting
AKIT25
AKIT26
1 m
2 m
3 m
4 m
5 m
6 m
+ 1.5m
H + 5m
V
+ 3m H
+ 5m V
+ 6m H
+ 1m V
+ 6m H
+ 2m V
+ 6m H
+ 3m V
+ 6m H
+ 4m V
+ 6m
H +
5m V
SX160
Ø44
Ø44
Ø46
Ø44
Ø44
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
SX220
Ø46
Ø46
Ø48
Ø48
Ø48
Ø48
Ø48
Ø48
Ø52
Ø52
Ø52
Ø52
Ø52
SX300
Ø48
Ø48
Ø50
Ø50
Ø50
Ø50
Ø50
Ø52
Ø52
Ø52
Ø52
Ø52
Ø52
SX400
Ø50
Ø50
Ø50
Ø52
Ø52
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
Ø54
SX600
Ø42
Ø42
Ø42
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
SX800
Ø38
Ø38
Ø40
Ø42
Ø42
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
Ø44
IMPORTANT:
DURING THE INSTALLATION OF THE KIT AKIT24, AKIT25,
AKIT26, THE SPECIAL CONDENSATE DRAIN CONNECTION
MUST BE CONNECTED TO A CLEAR WATER DRAIN.
At the end of the operation, carefully check all the seals of the
ducts for the evacuation of the combustion products and the
air intake.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
16
Ed 2021-02
16.HYDRAULIC CONNECTIONS
The connection to the water mains must be made with a G 3/4 "pipe for the SX160 model or G 1-1 / 4" for the rest of the
models. The cold water inlet is identified by the blue ring, while the hot water outlet is identified by the red ring).
HYDRAULIC COMPONENTS TO BE MANDATORY INSTALLED (NOT INCLUDED)
A. T-shaped drain cock
B. Expansion vessel with a capacity of not less than 5% of the contents of
the appliance.
C. Chemical treatment: <25 ° F polyphosphate dispenser or softener,
≥25 ° F softener.
D. Pressure reducer (for inlet water with pressure ≥ 600 kPa).
E. Filter to eliminate water impurities.
F. Check valve.
G. Shut-off valve.
H. Shut-off valve.
Respect the following water parameters, as required by Legislative Decree. 31 of February 2, 2001 (implementation of Directive
98/83 / EC relating to the quality of water intended for human consumption):
1. Total hardness: between 10 ° F and 25 ° F.
2. PH: between 6 and 8
3. Chlorides: max 200 mg / l
4. Conductivity: max. 2500 μS / cm
SAFETY VALVE
It drains the water from the tank in the presence of an internal pressure higher than 6.5 ± 0.5bar. The valve is sealed by the
manufacturer and tampering is prohibited: in case of tampering, the appliance warranty will not be recognized. If the valve
starts operating releasing water, it will be necessary to reduce the water inlet pressure in the appliance

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
17
Ed 2021-02
17.TRUNK GAS
Connect the gas supply line of the thread, present on the appliance, by means of a removable rigid connector: the pipe must exit
through the slot of the appliance. The attack gas connection is G 1/2 ": it is recommended to mount along the pipe, in the
vicinity of the generator and in an easily accessible location, a faucet interception manual gas. See in the figure below, the gas
attack and the slot of the tube passage.
Check the tightness of the gas pipe and make sure that it has been performed in accordance with regulations on gas system
(seeLOCAL REGULATIONS, AND INSTALLATION OF SAFETY).
18.ELECTRICAL CONNECTIONS
The machine is sold without mains plug: CPU must be mounted to the first installation.
Connect electrically to a power network at 230V-50Hz, single phase, and to an effective grounding. E 'need to perform a
polarized connection. The appliance cable is composed of three distinct colors cables (refer to the table below to identify the
correct polarization).
Connect the power cord of the appliance, taking care to comply with the electrical standards of the country in which the
appliance is installed. If the power cord is damaged, it must be replaced by a technical service center authorized by the
manufacturer, or by a similarly qualified person in order to avoid a hazard. For the eventual stopping of the appliance, in the
feeding of the same network is necessary to provide a disconnect device (not supplied) with an opening distance of the contacts
that allows complete disconnection in the conditions dictated by the overvoltage category III
LINE AND NEUTRAL PLUG TO BE THE SAME AS LINE AND NEUTRAL THE ELECTRICAL OUTLET.
Land
Neutral
Line
green yellow
blue
Brown
Assemble the apparatus in the vicinity of an isolating switch for the eventual general stopping of the appliance. This disconnect
device must be incorporated in the supply system in accordance with installation rules. Connect the power cord of the
appliance, taking care to comply with the electrical standards of the country in which the appliance is installed. In case of
replacement of the electric power cable, use only a cable with the same characteristics (cable H05 VV-F - 3x0.75).
Warning: The device has no protection against the effects caused by lightning. Before accessing any electrical part of the
appliance, remove the power supply using the bipolar switch.
INSTALLATION AND 'FINISHED, THE UNIT AND' READY TO BE LIT AND REGULATED.

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
18
Ed 2021-02
19.IGNITION AND TEMPERATURE CONTROL
POWER AND CONTROL THERMOSTAT
A. switch
B. control thermostat
C. thermostat safety limiter (manual reset)
D. thermometer
E. bright green light operation
F. reset button
1. 44°
2. 50°
3. 58°
4. 62°
5. 68°
1. Press the switch in position "I"
2. Turn the thermostat setting index B on the desired water temperature value
3. Check that the red light button F lock is turned off. If it is on, this means that the control apparatus is located in a state of
"block". In this case push the same button to unlock the control apparatus. The button's light goes out
4. After the ignition of the burner, indicated by the green light And, it starts the step of heating water. The burner will operate
until the water temperature set on the thermostat.
From that moment on the generator power cycle. The depression exerted by the operation of the fume extraction fan (under
proper conditions the state of the combustion circuit) ago closes the differential pressure switch contacts, and the control unit
starts the pre ventilation in the combustion chamber (the pre ventilation duration: 30 sec.). At the end of the pre-ventilation
phase they are controlled at the same time the opening of the gas valve and the action of the electrode for the spark ignition of
the burner. When the power of the burner the flame must be detected from the special ionization probe within the safety time
(10 sec), otherwise the control apparatus goes into a locked state. This is reported dell ' switching on of the red light of the
button. This can easily happen in a new plant, where it can still be present air in the gas pipe. In this case, wait about a minute,
unlock the device by pressing the illuminated button and start again a new cycle. Repeat until the residual air has been purged
and the ignition is regular.
SHUTDOWN
To turn off the generator for a short period to rotate the control thermostat knob on the minimum value and press the switch to
position "0".
To turn off the generator for a long time:
turn the thermostat knob on the minimum value
press the switch to position "0"
disconnect the electrical supply to the appliance at the main switch
close the gas shut-off valve.
If it is expected to leave the unit unused for a long period in an environment not heated and with the possibility of
frost, it is advisable to empty it completely.
PREVENTION AGAINST FREEZING
If the machine is switched off and exposed to very low temperatures, it will be necessary to empty the water tank to prevent
freezing risks

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
19
Ed 2021-02
20.GAS CHANGE
To change the gas, use only the special gas conversion kit prepared by the manufacturer, indicated in the table below, carefully
following the following instructions contained in the kit.
Device
SX160
SX220
SX300
SX400
SX600
SX800
G20
Kit code
AKMETSX160
AKMETSX220
AKMETSX300
AKMETSX400
AKMETSX600
AKMETSX800
P. entrance
20 mbar
20 mbar
20 mbar
20 mbar
20 mbar
20 mbar
P. output
12.2 mbar
12.5 mbar
12.5 mbar
12 mbar
13 mbar
12.5 mbar
G31
Kit code
AKPROSX160
AKPROSX220
AKPROSX300
AKPROSX400
AKPROSX600
AKPROSX800
P. entry
37 mbar
37 mbar
37 mbar
37 mbar
37 mbar
37 mbar
P. output
27.5 mbar
25 mbar
27.5 mbar
27.5 mbar
27.5 mbar
27.5 mbar
Model SX160
1) Switch off the appliance, close the gas interception valve and disconnect the power supply
2) Remove the burner door (A) and the insulating material (B)
TRANSFORMATION OF GAS SUPPLY
TO PROPANE G31
TRANSFORMATION OF GAS SUPPLY
TO METHANE G20
3) Unscrew the 4 screws (C), position the mask
(D) in front of the burners and tighten the
screws (C)
3) Unscrew the 4 screws (C), remove the mask (D)
in front of the burners and tighten the screws
(C)
4) Replace the injectors (E). Be careful not to lose the sealing washers
5) Start up the appliance and check the tightness of the gas circuit with a special spray
6) Put the burner door (A) and the insulating material (B) back in their original positions and tighten
with the fixing screws.
7) Adjust the burner pressure, according to the indicated value, using the REG screw on the gas valve.
The P.OUT pressure point can be used to check the value
8) Attach the label contained in the kit to indicate the new type of gas supply

UK - Manual installation, use and maintenance.
210-0203_Libretto_SX-ind_ATI_2021-02_GB.docx
20
Ed 2021-02
Models SX220 SX300 SX400 SX600 SX800
1) Switch off the appliance, close the gas interception valve and disconnect the power supply
2) Remove the burner door (A) and the insulating material (B)
3) Unscrew the gas pipe (E)
TRANSFORMATION OF GAS SUPPLY
TO PROPANE G31
TRANSFORMATION OF GAS SUPPLY
TO METHANE G20
4) SX300 / SX400 / SX600 / SX800 models only:
unscrew the screws (D) and replace (or remove
for SX800) the two slot closing plates (C) with
those present in the gas conversion kit. The
opening must remain in the lower part
5) Unscrew the 4 screws (F), position the mask
(G) in front of the burners and tighten the
screws (F)
4) SX300 / SX400 / SX600 / SX800 models only: unscrew
the screws (D) and replace (or insert for SX800) the
two slot closing plates (C) with those present in the
gas conversion kit. The opening must remain in the
lower part
5) Unscrew the 4 screws (F), remove the mask (G)
in front of the burners and retighten the screws
(F)
6) Replace the injectors (H). Be careful not to lose the sealing washers
7) Connect the gas pipe (E)
8) Start up the appliance and check the tightness of the gas circuit with a special spray
9) Adjust the burner pressure, according to the indicated value, using the REG screw on the gas valve. The P.OUT
pressure point can be used to check the value
10) Put the burner door (A) and the insulating material (B) back in their original positions and tighten with the
fixing screws.
11) Attach the label contained in the kit to indicate the new type of gas supply.
IMPORTANT:
CHECK THE SEALING OF THE GAS PIPES, SCREWS AND JOINTS BEFORE TURNING THE APPLIANCE ON. THE WORN GASKETS MUST