Atlas CP400 User manual

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 1 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
++--GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERV ICEABLE P A RT S INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
P A RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MA D E I N C H IN A
CP400 & CP700
Commercial Power Amplifiers

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 2 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
TABLE OF CONTENTS
Introduction ..........................................................................................................3
Features ...............................................................................................................3
Applications ..........................................................................................................3
Front Panel Description ........................................................................................4
Rear Panel Description .........................................................................................5
Input Wiring..........................................................................................................7
Speaker Output Wiring.........................................................................................9
Specifications .......................................................................................................15
Warranty ...............................................................................................................16
SAFETY INSTRUCTIONS
Please Read Carefully Before Installing or Operating This Product
• Read instructions fully.
• Pay attention to any and all warnings.
• Connect this amplier only to the correct operating voltage.
• Do not attempt to service this unit. Only a qualied service technician should open this unit for
servicing.
• Warning: To reduce the risk of re or electric shock, do not expose this appliance to rain or
moisture.
HEARING DAMAGE!
All professional loudspeaker systems are easily capable of producing very high sound pressure
levels. Use care with the operation of this amplier and wear the appropriate hearing protection.
Exposure to excessive sound pressure levels can cause permanent hearing damage.
SHOCK HAZARD!
The Atlas Sound CP400 and CP700, when in operation, can produce a shock hazard at the speaker
terminals. Make sure the amplier is turned off when installing or removing connections at the
speaker terminal barrier strip. After connecting the proper speaker load, REPLACE the terminal
strip cover!
VENTILATION
Although the CP400 and CP700 are internally fan cooled and have thermal protection circuitry,
adequate ventilation is required to ensure trouble-free operation. When rack mounting one or
more of the Atlas Sound CP Series power ampliers, install an exhaust fan in the rack to evacuate
heat buildup. Consult Atlas Sound’s Technical Support at 1-800-876-3333 for advice on thermal
management and assistance with rack selection for this product.
RACK MOUNTING
Although the internal output transformers are mounted close to the front panel, when rack
mounting the CP400 and CP700, be sure the unit has adequate front and rear support.

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 3 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
INTRODUCTION
Congratulations and thank you for purchasing the Atlas Sound CP400/CP700 dual channel power
amplier. This product is a professional grade audio power amplier specically designed for
demanding contractor applications and engineered to provide years of faithful service. Two
independent channels driven by separate power supplies ensure maximum channel separation and
ultra low distortion gures. Whether your application is a large distributed constant voltage sound
system or a high SPL sound reinforcement system, the Atlas Sound Series is the answer for high
power/low cost amplication needs.
FEATURES
• Independent power supplies
• Soft clip limiter protection
• Dual-speed, high efciency fan cooling
• Stepped attenuators mounted on the rear for security
• Stereo, bridge, or parallel operating modes selectable via rear mounted switch
• Balanced inputs on barrier strip and XLR connectors
• Loop through feature on male XLRs, one per channel input
• Short-circuit, temperature, and DC offset protection
• 25V, 70.7V, 100V, and direct coupled (2,4, and 8 Ω) outputs mounted on barrier strips with covers
for safety
• Toroidal output transformers provide extended high frequency response and effectively lower the
electrical interference
• Power-up muting
APPLICATIONS
The Atlas CP400/CP700 are the perfect choice for distributed paging/BGM systems, foreground
music systems, and distributed sound masking applications. They are also at home in night clubs,
theaters, portable sound systems, and anywhere clean high-delity audio amplication is needed.

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 4 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
FRONT PANEL DESCRIPTION
Figure 1
1. Power Switch
This rocker switch supplies power to the amplier. A red LED located above the power
switch will illuminate when the amplier is switched on.
2. Protect LED Indicators
The amplier features several types of protection circuitry to prevent damage during
power-up or fault conditions. If any of these LEDs illuminate, one of the various protection
features is safeguarding the amplier. The output relays will disconnect the speaker loads when
the protection circuitry detects a fault condition.
•Loudspeaker Protection - When power is rst applied, the speaker protection relay is
open, preventing transients from reaching the loudspeakers. After the internal power
supplies have stabilized, the relay will close, connecting the amplier output to the load.
The yellow Protect LEDs will illuminate during this power-up process.
•Thermal Protection - The amplier protection circuitry monitors itself for excessive
internal operating temperatures. In the event this circuitry detects abnormal thermal
conditions (blocked cooling fan or high ambient temperatures), the speaker relay
will disconnect the speaker load from the amplier. Once the internal operating
temperature drops back to a safe level, the relay will close, reconnecting the speaker load
to the amplier.
•Short Circuit Protection - The yellow Protect LEDs will illuminate should the amplier
detect a short circuit on the attached speaker load or if the load impedance is too low.
When this condition is detected, the internal speaker relays will open up, disconnecting
the load from the amplier. The protection circuitry will stay activated until the fault is
cleared.
Note: Once the specic fault has been corrected, the power may have to be cycled to reset the
protection circuitry.
3. Signal “Status” LED Indicator
The green “Status” LEDs will illuminate once the input signal has reached -26 dBV or higher.
++--GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERV ICEABLE P A RT S INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
P A RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
M A D E I N C H I N A
2
3
4
1

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 5 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
4. Limit LED Indicator
The CP400 and CP700 come equipped with limiter circuitry and LEDs to indicate when this
circuitry is activated. The limiter circuitry engages only when the input signals reach a specic,
factory set magnitude. Once this limit has been reached, the circuitry will reduce the input level
enough to prevent clipping at the speaker output terminals.
REAR PANEL DESCRIPTION
Figure 2
5. Gain Controls
One stepped attenuator per channel increases or decreases the sensitivity by 2 dB per step.
Maximum voltage gain is 32 dB.
6. CH1/CH2 Inputs (XLR Connectors)
Two female XLR inputs (one per channel) are provided. These inputs are balanced and
congured as follows: pin 1 ground, pin 2 +, pin 3 -. The XLR connections are typically used in
portable audio systems where quick connect and disconnect is warranted.
7. Balanced Barrier Strip Inputs
Balanced inputs are provided on this barrier strip for permanent installation applications. The
use of the appropriate spade type lug is highly recommended for best connection integrity and a
neat, professional appearance.
8. CH1/CH2 Loop Through
Two male XLR (one per channel) are provided for looping the input signals to other devices.
These connectors are wired in parallel with the female XLR inputs, pin for pin.
++--GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERV ICEABLE P A RT S INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
P A RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
M A D E I N C H I N A
7
9
11
5
8
6
10

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 6 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
9. Stereo/Parallel/Bridge Switch
This 3 position switch changes the operating mode of the amplier. DO NOT move this switch
when the amplier is powered up and connected to a load.
• Stereo - When the switch is set to this position, the amplier operates as two independent
ampliers. Use this position for stereo program material or for two discreet paging/sound
masking zones.
• Parallel - When the switch is set to this position a single mono input signal is to be used.
Connect the input wiring to either channel 1 OR channel 2. The one input signal will drive
both amp channels. Use this position when two speaker zones are being fed by a mono
signal. (See note below)
• Bridge - When the switch is set to this position, connect the mono input signal to channel
1 ONLY. The speaker load is connected across the two positive terminals as shown in
Figure 7 on page 10. The amplier will deliver approximately twice the voltage across the
load. Please observe the minimum load specication when operating in Bridge mode.
Note: A 6 dB loss of output power will occur when operating in parallel mode. To over come
this loss, connect the positive terminal on input 1 to the positive terminal on input 2 and
connect the negative terminal on input 1 to the negative terminal on input 2. Short lengths of
22-gauge wire can be used.
10. CH1/CH2, Low Impedance Speaker Outputs
The amplier direct speaker outputs bypass the internal constant voltage transformers and are
used for direct connection to loudspeakers. The amplier will operate into 2, 4, and 8 Ω loads
The use of appropriately sized spade lugs is recommended for speaker wire termination;
connect the speaker line common to the “-” terminal and the positive lead to the “+” terminal.
For high power applications, use the proper gauge wire for the speaker connections. Contact
Atlas Sound Tech Support (1-800-876-3333) for assistance in determining the proper size wire.
11. CH1/CH2, 25/70.7/100V Speaker Outputs
The amplier will drive constant voltage speaker loads for use in commercial business music/
paging systems and sound masking systems. The use of spade lugs for terminating and
connecting the speaker home runs is recommended. The speaker line common connects to the
“0” terminal and the positive lead connects to the desired voltage for required system requires
for proper operation (Figures 8,9,10; Pages 11-12).
Calculating Constant Voltage Loads
To calculate the maximum quantity of transformer coupled loudspeakers you can safely
connect to the amplier, rst add up the total number of speakers that will be connected to
one channel of the amplier, then multiply that total speaker number by the tap setting you
plan to use. The result will be the load in watts that the amp output channel will see. It is
good engineering practice to leave a 20% margin below the maximum rated output power
of the amplier. In this case, one channel of the amplier can supply 350 W of power at
70.7V. Derate this by 20%, leaving 280 W of power available for constant voltage speakers.

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 7 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
INPUT WIRING
Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The
use of crimp type spade lugs is highly recommended for permanent installations. At the input
section located on the rear of the amplier, wire the “hot”/positive lead to the “+” terminal, the
“common”/negative lead to the “-” terminal and the shield/drain to the “ground” terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female
patch cables to accommodate outputs from a mixer, equalizer, or crossover when the amplier is
used as a portable sound system amplier.
Figure 3
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PARALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
Black (-)
Shield
White (+)
Black (-)
Shield
White (+)

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 8 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Unbalanced Input
Unbalanced wiring typically is found on consumer equipment (CD players, DVD players, etc.) and
is generally a compromise of noise rejection and cable lengths. A single conductor and an overall
shield are most common, as in the standard cables supplied with consumer equipment. Keep
unbalanced wire lengths within 10' between equipment, wire the hot lead to the “+” terminal, and
the shield to the ground terminal. Install a jumper wire between the “-” terminal and the ground – a
loss of gain will result without this jumper (Figure 4).
Figure 4
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PARALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
Jumper
White/Red (+)
Shield White/Red (+)
Shield

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 9 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
SPEAKER OUTPUT WIRING
Low Impedance Direct Coupled Output (Stereo)
For direct coupled operation into 2, 4, and 8 Ω loads, connect the loudspeaker leads to the barrier
strip connections labeled “Direct Output”; connect the hot lead to the “+” terminal and the
common lead to the “-” terminal. The use of heavy gauge wiring is recommended to avoid voltage
drops, which can occur as a result of wasted power in the cable. Contact Atlas Sound Tech Support
(1-800-876-3333) for suggestions on cable capacities. Be sure you know the quantity of speakers
and cable lengths before calling (Figure 5).
Low Impedance Direct Coupled Output (Parallel Mono)
Observe the speaker connection information in the preceeding paragraph (Stereo Direct Coupled
Output). With the amplier turned OFF, move the rear mounted selector switch to the “Parallel”
position and connect your mono input wiring to either the channel one or channel two inputs. Both
channels will be driven from this mono signal (Figure 6).
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE P A RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MAD E IN CHINA
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE P A RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MAD E IN CHINA
Switch set
to “Stereo”
Switch set
to “Parallel”
Figure 6
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE P A RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MA DE IN CHINA
White
Black
Shield
Optional Jumpers
See Note on Page 6
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
To direct coupled
loudspeakers
To direct coupled
loudspeakers
Figure 5

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 10 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Bridge Mono Configuration (Direct Coupled)
If higher power levels are required, the Atlas amplier can be used in Bridge Mono mode, which
utilizes both channels of the amp across the speaker load.
With the amplier turned OFF, move the rear mounted selector switch to the “Bridge” position and
connect the input signal to channel one. Connect your speaker load (4 and 8 Ω only) across the “+”
terminals of both channels, with channel 1 being positive and channel 2 being negative (Figure 7).
CAUTION: A high voltage potential exists across the two “+” speaker terminals when operating in
any Bridge Mode application!
Figure 7
25V, 70.7V, and 100V Transformer Output Wiring
For transformer coupled operation into high impedance loads, connect your loudspeaker leads
to the barrier strip connections labeled “Audio Transformer.” Connect the speaker home runs as
follows:
• 25V - Connect the positive speaker lead to the terminal labeled “100” and the negative
speaker lead to the terminal labeled “70” (Figure 8).
• 70.7V - Connect the positive speaker lead to the terminal labeled “70” and the negative
speaker lead to the terminal labeled “0” (Figure 9).
• 100V - Connect the positive speaker lead to the terminal labeled “100” and the negative
speaker lead to the terminal labeled “0” (Figure 10).
Note: Refer to page 6 of this manual to the paragraph entitled “Calculating Constant Voltage
Loads” to determine how many transformer coupled loudspeakers you can drive with the Atlas
amplier.
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
To loudspeakers,
4 Ω minimum
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE P A RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MAD E IN CHINA
Switch set
to “Bridge”

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 11 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
To 70.7V speaker load
25V
70.7V
To 25V speaker load
To 25V speaker load
To 70.7V speaker load
Figure 8
Figure 9

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 12 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
100V
To 100V speaker load
To 100V speaker load
Figure 10

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 13 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Bridge Mono Transformer Coupled Output Wiring for 140V/200V Output Operation
The amplifier can be configured to drive 140V and 200V speaker lines.
Please observe all necessary safety precautions as the potential for electric shock at the speaker
terminals is present.
With the amplier turned OFF, move the rear mounted selector switch to the “Bridge” position and
connect the input signal to channel 1. Connect your speaker load across the “+” terminals of both
output terminals as follows:
• 140V Operation - Connect the positive lead of the speaker load to the channel 1 70V
positive “+” terminal, the negative speaker lead connects to the channel 2 70V positive
“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.
Consult your local codes to determine if Class I wiring is required (Figure 11).
• 200V Operation - Connect the positive lead of the speaker load to the channel 1 100V
positive “+” terminal, the negative speaker lead connects to the channel 2 100V positive
“+” terminal. Connect a suitable jumper wire between the two terminals labeled “0”.
Consult your local codes to determine if Class I wiring is required (Figure 12).
CAUTION: A high voltage potential exists across the two “+” speaker terminals when operating in
any Bridge Mode application!
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
Figure 11
Note Jumper
To 140V speaker load

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 14 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
++- -GND
CH-2 CH-1
AMPLIFIER INPUTS
THRU
IN
THRU
IN
CAUTION
AC100V-50/60Hz
AC120V-50/60Hz
AC230V-50/60Hz
AC240V-50/60Hz
TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER SERVICEABLE PA RTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
POWER
CP700
Commercial
Power
Amplifier
Per Channel
Output Power
400 W / 4 Ohms
350 W / 70.7 V
PROTECT
LIMIT
SIGNAL
CH-1
PROTECT
POWER
LIMIT
SIGNAL
CH-2
CP700
Commercial Power Amplifier
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
LEVEL
-
0
0
5
6
4
0
3
2
2
6
2
2
1
8
1
6
1
4
1
2
1
0
8
6
4
2
0
1601 Jack McKay Blvd., Ennis, TX 75119
(800) 876-3333 AtlasSound.com
STEREO
PA RALLELBRIDGE
GND
CH-1 CH-1
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
+
CH-2 CH-2
- 100V +
-+
70V
-+
25V
8, 4, and 2 Ohms AUDIO TRANSFORMER
DIR. OUTPUT ISOL. OUTPUT
-+70 1000
BRIDGE
MONO
-
AVIS RISQUE DE CHOC ELECTRIQUE
NE PAS OUVRIR
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
MADE IN CHINA
Figure 12
Note Jumper
To 200V speaker load

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 15 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
SPECIFICATIONS
DIRECT POWER OUT PROTECTION CIRCUITS
Max Average Power @ 35 Hz-20 kHz
with 0.1% THD (10-80K Filter)
CP400
8 Ω, 1 kHz, 0.1% THD 160 W X 2
4 Ω, 1 kHz, 0.1% THD 240 W X 2
2 Ω, 1 kHz, 0.1% THD 270 W X 2
Bridged Mono 8 Ω 500 W
1 kHz, 1% THD
Bridged Mono 4 Ω 600 W
1 kHz, 1% THD
CP700
240 W X 2
400 W X 2
550 W X 2
850 W
1100 W
Output Offset Voltage Protection
Heat Sink Overheat Protection
Transformer Overheat Protection
Load Shorting Protection
Power On/Off Protection
Soft Clip Limiters
TRANSFORMER OUTPUTS CONTROLS
25V 175 W X 2
70V 200 W X 2
100V 200 W X 2
140V Bridged 400 W
200V Bridged 400 W
280 W X 2
350 W X 2
350 W X 2
700 W
700 W
Power Switch, Ch 1/Ch 2 gain (41 step)
Parallel/Stereo/Bridge Switch
FREQUENCY RESPONSE COOLING
Direct Outputs (±3 dB) 30 Hz-50 kHz
Transformer Outputs (±3 dB) 30 Hz-16 kHz
Dual Speed Fan, Temperature Controlled
THD+N INDICATORS
8 Ω, 1 kHz, 240 W per channel <.05% Power, Protect, Signal, Limit
SENSITIVITY DIMENSIONS
Rated Output into 8 Ω 1.25V 5.19" X 18.9" X 16.85" (132 mm X 480 mm X 428 mm)
VOLTAGE GAIN NET WEIGHT
32 dB CP400
44.5 lbs (20.2 kg)
CP700
54 lbs (24.3 kg)
INPUT IMPEDANCE SHIPPING WEIGHT
Balanced/Unbalanced 20 k/10 k ΩCP400
47 lbs (23 kg)
CP700
57 lbs (26 kg)
DAMPING FACTOR
8 Ω Output, 10 V rms >200 dB
S/N RATIO
8 Ω per Channel @240 W >100 dB

Owner’s Manual
CP400 & CP700
Commercial Power Amplifier
AtlasSound.com – 16 –
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800.876.3333 • Fax: 800.765.3435
Limited Warranty
All products manufactured by Atlas Sound are warranted to the original dealer/installer, industrial or commercial purchaser to be
free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall
extend from the date of purchase for a period of three years on all Atlas Sound products, including SOUNDOLIER brand, and
ATLAS SOUND brand products except as follows: one year on electronics and control systems; one year on replacement parts;
and one year on Musician Series stands and related accessories. Additionally, fuses and lamps carry no warranty. Atlas Sound will
solely at its discretion, replace at no charge or repair free of charge defective parts or products when the product has been applied
and used in accordance with our published operation and installation instructions. We will not be responsible for defects caused by
improper storage, misuse (including failure to provide reasonable and necessary maintenance), accident, abnormal atmospheres,
water immersion, lightning discharge, or malfunctions when products have been modified or operated in excess of rated power,
altered, serviced or installed in other than a workman like manner. The original sales invoice should be retained as evidence of pur-
chase under the terms of this warranty. All warranty returns must comply with our returns policy set forth below. When products
returned to Atlas Sound do not qualify for repair or replacement under our warranty, repairs may be performed at prevailing costs
for material and labor unless there is included with the returned product(s) a written request for an estimate of repair costs before
any non-warranty work is performed. In the event of replacement or upon completion of repairs, return shipment will be made with
the transportation charges collect.
EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR
PERSONAL INJURY, ATLAS SOUND SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT, CONSEQUENTIAL
OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION, USE OR INABILITY TO USE THE PRODUCTS.
THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Atlas Sound does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obliga-
tion, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.
Service
Should your CP400 or CP700 require service, please contact the
Atlas Sound warranty department at 1-877-689-8055, ext. 277 to obtain an RA number.
Atlas Sound Tech Support can be reached at 1-800-876-3333.
Visit our web site at www.AtlasSound.com to see other Atlas products.
©2010 Atlas Sound L.P. All rights reserved. Atlas Sound and Atlas Power are trademarks of Atlas Sound L.P.
All other trademarks are the property of their respective owners. ATS002102 RevE 08/10
Other manuals for CP400
1
This manual suits for next models
1
Table of contents
Other Atlas Amplifier manuals

Atlas
Atlas STRATEGY AA35 User manual

Atlas
Atlas TSD-DA28 User manual

Atlas
Atlas F6-MF User manual

Atlas
Atlas 100 Series User manual

Atlas
Atlas AA30PHD User manual

Atlas
Atlas AA120 User manual

Atlas
Atlas STRATEGY AA35 User manual

Atlas
Atlas TSD-PA252G User manual

Atlas
Atlas AA200PHD-CE User manual

Atlas
Atlas TSD-PA122G User manual