Aurora Scientific 826A User manual

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 2
Copyright © 2015 Aurora Scientific.
Aurora Scientific
25 Industry Street
Aurora, ON, Canada L4G1X6
Tel: 1-905-727-5161
Toll Free (N. America): 1-877-878-4784
Fax: 1-905-713-6882
Email: techsupport@aurorascientific.com
Web Site: www.AuroraScientific.com

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 3
Revision History
Date
Version
Number
Document Changes
07/06/2015
1.0
Initial Draft

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 4
Table of Contents
1Introduction ..................................................................................................................................... 5
2Quick Start Guide ............................................................................................................................. 6
2.1 ....Attaching the Liquid Coolant Lines ................................................................................................... 6
2.2 ....Filling the Liquid Reservoir................................................................................................................ 6
2.3 ....Positioning the Unit .......................................................................................................................... 7
2.4 ....Module Operation ............................................................................................................................ 8
3Maintenance .................................................................................................................................... 9
4Performance Guarantee, Technical Support, Warranty and Repair Information........................... 10
4.1 ....Performance Guarantee................................................................................................................. 10
4.2 ....Technical Support........................................................................................................................... 10
4.3 ....Technical Support Contact Information and Return Shipping Addresses........................................ 10
4.4 ....Warranty ........................................................................................................................................ 11
4.5 ....Returning Products to Aurora Scientific for Repair ......................................................................... 12
5Specifications ................................................................................................................................. 14

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 5
1Introduction
The 826A Water Cooler is intended to be used as a simple liquid coolant circulator, with Aurora Scientific
800 Series apparatus. The Water Cooler incorporates a brushless DC pump to circulate the water through
an aluminum radiator to exchange heat with the air.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 6
2Quick Start Guide
Setting up an 826A Water Cooler is a simple procedure. This Quick Start Guide will guide you through the
process.
2.1 Attaching the Liquid Coolant Lines
Two lengths of tubing, both six feet in length have been supplied to attach the 826A Water Cooler to an
Aurora Scientific 800-Series Test System. The Tubing has been pre-fitted with the required fittings to
easily connect to the test system. The connection to the circulator uses a threaded compression fitting or
a “hose” screw. It does not matter which side the supply and return are connected to the test system.
To attach the hoses to the circulator, slide on the hose screws over the end of the hoses before mating
the hose to the back of the circulator. Once the hoses have been firmly pressed on, tighten up the hose
screws, to secure the connection (see Figure 1).
Figure 1: Attaching Hoses to Circulator
2.2 Filling the Liquid Reservoir
WARNING: FILL RESERVOIR ONLY WITH COOLANT OR DISTILLED WATER! TAP WATER WILL
CORRODE THE ALUMINUM RADIATOR IN THE UNIT AND CAUSE SEVERE LEAKAGE AND DAMAGE.
Ensure all tubing connections have been completed before attempting to fill the unit. Place the 826A unit
so that it is the highest point in the cooling loop, (above the Test System and tubing). Open the reservoir
cap on the top of the unit. Use a coin or large flathead screwdriver to remove the reservoir cap. A small
funnel has been included with the liquid coolant to minimize spills. Slowly, pour some of the coolant
liquid into the reservoir and carefully fill up to the top (See Figure 2).

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 7
Figure 2: Filling Coolant Reservoir
NOTE: Be careful not to overfill the reservoir, since any overflow from the reservoir will drain
directly into the 826A case. You should fill the reservoir to approximately 1.5cm (1/2”) from the
top of the reservoir. If you should overfill the reservoir, screw the cap back on, place a towel under
the liquid circulator and tilt the unit from left to right to drain the liquid from the case. Under no
circumstances should you turn the 826A upside down to drain overflow liquid from the case since
this will damage the fan due to the liquid draining through the fan. .
Once the reservoir has been filled, switch on the 825A to allow the pump to fill the rest of the system and
tubing with coolant. When the system begins running for the first time the fluid inside the reservoir will
begin to drain. As this happens continue to fill the reservoir with distilled water until the draining has
stopped. Once full, replace the cap and unplug the power adapter from the system until ready for use.
If the fluid refuses to flow through the system immediately when power is connected, it is likely that the
pump is still dry. In this case you may attempt to prime the pump by slightly tilting the unit back and
forth to encourage the liquid to flow. Once the pump has begun to circulate, you may replace the
circulation hoses to the test system.
2.3 Positioning the Unit
Positioning the coolant circulator correctly is essential to its proper operation. Firstly the unit should be
positioned a reasonable distance away from the actual test system as vibration from the pump and fan
will make mechanical measurements noisy. If the test system is mounted on a vibration isolation table,
DO NOT locate the coolant circulator on it as this will cause vibration noise to appear in the data.
Since the head pressure generated by the pump is small, the 826A Water Cooler should be mounted
slightly above or at about the same height as the test system. Take care to mount the unit within ±0.5m
of the height of the 800-series apparatus or the circulator will have trouble driving coolant through the
entire loop.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 8
2.4 Module Operation
Once all of the connections have been made and the coolant reservoir filled, the 826A is ready for use.
The coolant circulator does not have a power switch, as it draws its power from a tap on the rear of the
825A. Circulation is therefore turned on by switching the 825A on or off. Once the unit has been plugged
in the fan speed can be set with the two position switch located on the back panel of the coolant
circulator. The low setting is in general sufficient to be used with all ASI 800 Series test systems for most
temperature settings of the 825A. Aurora Scientific recommends switching the fan setting to high when
operating at either extremes of the TEC controller’s range.
The Module is equipped with dry break fittings to avoid any spillage of coolant in the event that the unit
must be moved.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 9
3Maintenance
To prevent air from getting into the system and causing problems with coolant flow, the user should
periodically check the coolant level in the reservoir to verify that it is full (approximately 1.5cm or ½” from
the top) and top up as necessary.
Aurora Scientific recommends replacing the coolant annually to keep your system operating optimally.
If you run out of coolant, distilled water can be used to top up the system. DO NOT use ordinary tap
water, as this will corrode the aluminum radiator inside the unit. Additional bottles of coolant can be
ordered from Aurora Scientific in the event that the coolant supplied with the system runs out.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 10
4Performance Guarantee, Technical Support, Warranty and Repair
Information
Aurora Scientific is dedicated to providing you with products that allow you to meet your research goals.
For this reason we offer a performance guarantee, technical support and a new product warranty. Our
performance guarantee ensures you purchase the correct instrument for your research. Technical
assistance is always free and will be available for the life of your product. If you do have a problem with a
product then please know that all Aurora Scientific products are covered by a three-year warranty
covering both parts and labour. If you need to return a product to us for repair then consult the final
section of this chapter for returns information.
4.1 Performance Guarantee
Our performance guarantee states: if for any reason a new product does not meet your research needs
then you can return it to Aurora Scientific for exchange or a full refund. The performance guarantee only
applies to new products and must be exercised within 60 days of receipt of the instrument.
4.2 Technical Support
Technical assistance is always free and will be available for the life of your product. Please don’t hesitate
to contact us if you have any technical support issues. Contact us by telephone, email, fax, or regular
mail.
4.3 Technical Support Contact Information and Return Shipping Addresses
Canada, USA, South America, Middle East, Africa
Aurora Scientific
25 Industry St.
Aurora, Ontario, CANADA
L4G 1X6
Attn: RMA Returns
Tel: +1-905-727-5161
Fax: +1-905-713-6882
Email (all Aurora Scientific Offices): techsupport@aurorascientific.com
Web Site: www.AuroraScientific.com
Europe
Aurora Scientific Europe
Hilton House
3 Ardee Road
Rathmines, Dublin 6, Ireland
Attn: RMA Returns
Tel: +353-1-525-3300
Fax: +353-1-443-0784
Asia, Australia, New Zealand

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 11
Aurora Scientific Asia
Unit B, 10/F
Charmhill Centre
50 Hillwood Road
Tsimshatsui, Kowloon, Hong Kong
Attn: RMA Returns
Tel: +852-3188-9946
Fax: +852-2724-2633
Distributors
Japan
Kantoh Electronics Co., Ltd.
1-25-14, Nakacho, Meguro-ku
Tokyo, 153-0065, Japan
Tel: +81-03-5773-5028
Fax: +81-03-5773-5029
Email: info@Kantoh-elec.co.jp
Web site: http://www.kantoh-elec.co.jp
4.4 Warranty
Products manufactured by Aurora Scientific Inc. are guaranteed to the original purchaser for a period of
three (3) years. Under this warranty, the liability of Aurora Scientific is limited to servicing, adjusting and
replacing any defective parts that are of Aurora Scientific manufacture. Aurora Scientific is not liable to
the customer for consequential or other damages, labour losses or expenses in connection with or by
reason of the use or inability to use the products manufactured by Aurora Scientific.
Guarantee of parts and components not manufactured by Aurora Scientific shall be the same as the
guarantee extended by the manufacturer of such components or parts. Where possible such parts
returned to Aurora Scientific will be sent to the manufacturer for credit or replacement. Ultimate
disposition of these items will depend upon the manufacturer's decision.
All shortages must be reported within ten (10) days after receipt of shipment.
Except where deviations are specified in literature describing particular products, the limited warranty
above is applicable to all Aurora Scientific products, provided the products are returned to Aurora
Scientific and are demonstrated to the satisfaction of Aurora Scientific to be defective.
Transportation costs of all products returned to Aurora Scientific must be borne by the customer and
products must be returned to Aurora Scientific within three years after delivery to the original purchaser.
Aurora Scientific cannot assume responsibility for repairs or changes not authorized by Aurora Scientific
or damage resulting from abnormal or misuse or lack of proper maintenance.
Repair or service work not covered under the limited warranty will be billed at current service rates.
NO EXPRESS WARRANTIES AND NO IMPLIED WARRANTIES WHETHER FOR MERCHANTABILITY OR FITNESS
FOR ANY PARTICULAR USE, OR OTHERWISE OTHER THAN THOSE EXPRESSLY SET FORTH ABOVE WHICH
ARE MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, SHALL APPLY TO PRODUCTS SOLD BY AURORA
SCIENTIFIC INC, AND NO WAIVER, ALTERATION OR MODIFICATION OF THE FOREGOING CONDITIONS

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 12
SHALL BE VALID UNLESS MADE IN WRITING AND SIGNED BY AN EXECUTIVE OFFICER OF AURORA
SCIENTIFIC INC.
4.5 Returning Products to Aurora Scientific for Repair
There are a few simple steps that must be completed before returning your product to Aurora Scientific.
1. Obtain a Return Material Authorization number (RMA#).
Contact our technical support department to obtain a RMA #. We require the serial number of the
product along with your contact information, i.e. your name, institution, phone number and email
address.
2. Package your instrument.
Use the original packaging materials if available. If you do not have original packaging then ensure that
the product is wrapped in bubble pack and placed in a sturdy corrugated cardboard box. If you are
returning a force transducer please place the transducer head in the plastic protective box and then wrap
the plastic box in bubble pack and place it in a small cardboard box which can then be placed in the larger
box along with the electronics. For force transducer repairs we require both the transducer head and the
control electronics. Please don't send the power cord. When returning a muscle lever system wrap the
motor in bubble pack and place it along with the lever arm in a small cardboard box and then place that
box in the larger shipping container along with the controller. For muscle lever repairs we require the
motor, lever arm, motor cable and control electronics. Please don't send the power cord.
3. Prepare Customs documents.
Canadian Clients: no customs documents are required, skip to step 4.
European Clients: no customs documents are required, skip to step 4 and ship to Aurora Scientific Europe.
Asia, Australia and New Zealand Clients: no customs documents are required, skip to step 4 and ship to
Aurora Scientific Asia.
USA and Rest of the World Clients: You must include a Commercial Invoice (CI) with the shipment. Please
click this link to download a blank CI.
You can also prepare the commercial invoice yourself instead of using the downloadable form. Print the
document on your company's letterhead and include the following information: Date, Shipper's Name,
Address and Phone Number (your company information), Consignee's Name, Address and Phone Number
(Aurora Scientific Inc. is the Consignee), Country of Origin of Goods (this will be Canada if you purchased
the instrument from Aurora Scientific or USA if your product was purchased from Cambridge
Technology), Conditions of Sale (include the following statement: GOODS RETURNING TO FACTORY FOR
REPAIR, TEMPORARY IMPORT), Number of Packages (normally 1), Description of Goods (e.g. Model 300B
Muscle Lever System, Serial Number 1111), Quantity of Each Item (normally 1) and Value for Customs
Purposes (the original purchase price of the instrument).
Place three (3) copies of your CI in an envelope and mark the outside CUSTOMS PAPERS ENCLOSED.
Attach the envelope to the outside of the box.
4. Choose a shipper and prepare the waybill.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 13
European Clients: ship your instrument to Aurora Scientific Europe in Dublin, Ireland.
Asia, Australia and New Zealand Clients: ship your instrument to Aurora Scientific Asia in Hong Kong.
Canadian, USA and all other Clients: ship your instrument to Aurora Scientific in Ontario, Canada.
You may ship your instrument back to us via the courier of your choice or via parcel post. If possible we
prefer that you ship via FedEx. You are responsible for both the shipping and brokerage charges so please
mark the waybill accordingly. Please don't ship freight collect. Shipments sent freight collect will be
received but you will be invoiced for the shipping charges when your instrument is returned.
5. Prepare and send a purchase order.
After we receive the instrument we will evaluate it and contact you with the estimated repair cost. We
require a purchase order before we can repair and return your instrument. Please fax or email us the
purchase order at your earliest convenience.

Water Cooler Instruction Manual
Model: 826A
© Aurora Scientific, 2015 VER. 1.00
page 14
5Specifications
Water Pump
Spherical Motor: Electronically commutated with brushless DC design.
Voltage Range: 8 to 13.2 VDC
Max System Pressure: 22 PSI
Head Pressure: 390 m/bar @ 12 VDC
Maximum Flow: 350 L/h (1.54 US Gal/min) @ 12VDC
Fan
Voltage: 12 VDC
Current: 0.3A
Speed: 1800 RPM
Air Flow: 74.4 CFM
Pressure: 3.2 mm water
Electrical
Power Requirements: 12 VDC, 1.25A max. (Powered from power tap on 825A)
Table of contents
Popular Water Dispenser manuals by other brands

IBC Water
IBC Water AST0715MP-960 Installation & operating instructions

Lancaster Water Treatment
Lancaster Water Treatment X FACTOR LX15 Series Installation, operating and service manual

Elkay
Elkay EMABF8 Series Installation & use manual

Oasis
Oasis Osmosis Home installation manual

Monarch Water
Monarch Water ULTIMATE MINI AQUA HE install guide

Haier
Haier HLM-109B instruction manual