Autonics GP Series User manual

© Copyright Reserved Autonics Co., Ltd. iii
GP-XBM (RS485)
Solution Guide

ii © Copyright Reserved Autonics Co., Ltd.

© Copyright Reserved Autonics Co., Ltd. 3
Preface
Thank you very much for selecting Autonics products.
Please familiarize yourself with the information in this manual and in the product manuals before using
them.
This solution guide contains information about a specific architecture solution and does not replace any
specific product documentation.
This document does not attempt to describe the entire solution architecture and configuration but only
introduce some basics procedures. Customization of this solution can be made by the users in respect of
safety laws and regulations.

4 © Copyright Reserved Autonics Co., Ltd.
Document Guide
This manual provides procedure steps for a particular solution architecture. It does not offer any
guarantee concerning matters beyond the scope of this manual.
This manual may not be edited or reproduced in either part or whole without written permission
of Autonics.
This manual is not provided as part of the product package. Please visit our home-page
(www.autonics.com) to download a copy.
The content of this manual may vary depending on updates of the product software and others
unforeseen developments within Autonics. It is subject to change without prior notice. Upgrade
notices are published through our homepage.
We contrived to describe this manual the easiest and more accurate way. However, if there are
any corrections required or questions, please notify us these remarks on our homepage.

© Copyright Reserved Autonics Co., Ltd. 5
Document Symbols
Symbol
Description
Additional information about a particular feature.
Failure to follow instructions can result in serious injury or death.
Failure to follow instructions can lead to a minor injury or product
damage.
An example of the concerned feature's use.
※1
Annotation mark.

6 © Copyright Reserved Autonics Co., Ltd.
Document Version History
Date
Version
Author
Description
December 17th 2016
v1.0
기술지원팀 - YCG
Document creation
August 8th 2017
v2.0
기술지원팀 - GTE
Document revision and template update
Add several sections
September 15th
2017
v2.0.1
기술지원팀 - GTE
Minor text updates

© Copyright Reserved Autonics Co., Ltd. 7
Table of Contents
Preface.................................................................................................................3
Document Guide .................................................................................................4
Document Symbols.............................................................................................5
Document Version History.................................................................................6
Table of Contents................................................................................................7
1Solution Overview.......................................................................................9
1.1 Solution description 9
1.2 Solution components and version 9
1.3 Solution architecture 10
1.4 Communication cable pin details and dimensions (Autonics model: C3M5P03-
D9M0-W4*0) 10
2GP-S070 Communication Settings..........................................................12
2.1 GP-Editor project settings 13
2.2 GP-S070 Ethernet communication settings for GP-Editor 14
2.3 Send GP-Editor project to GP-S070 device by Ethernet 18
2.4 GP-S070 serial communication settings for XBM PLC 19
3XBM Project Settings................................................................................22
4GUI Example..............................................................................................26
4.1 Solution overview 26
4.1.1 GP-S070 drawing (in GP-Editor from Autonics) 26
4.1.2 PLC program (in XG 5000 from LS) 26
4.2 GP-S070 –XBM connection 26
4.3 GP Editor graphic 27
4.3.1 Numeral display 27
4.3.2 Numeral input 28
4.3.3 Touch key (Up key) 29
4.3.4 Touch key (Down key) 30
4.3.5 Lamp 31
4.3.6 Touch key (Reset key) 32
4.3.7 Graphic result 33
5Appendix....................................................................................................35
5.1 Serial communication settings 35
5.1.1 Change CH1 communication settings in GP-Editor 35
5.1.2 Change CH1/CH2 communication settings in the GP device 37
6Troubleshooting........................................................................................38
6.1 GP-S070: language settings 38

8 © Copyright Reserved Autonics Co., Ltd.

1 Solution Overview
© Copyright Reserved Autonics Co., Ltd. 9
1Solution Overview
1.1 Solution description
Autonics GP-S070-T9D6 device from the GP/LP series is a 7.0 inch LCD color touch panel with
build-in serial connection through RS-422 and RS-232C ports. It is a standalone screen with custom OS
and dedicated graphic editor software to create up to 500 graphic pages.
Thanks to its characteristic, it can be added on top of any existing automation architecture with
different type of serial connection and can monitor different devices parameters or statuses and key
Setting Values or Present Values, facilitating the access to data that was not in the previous architecture.
This solution brings following benefits to your current installation:
Allows to monitor in real time PLC & devices status and feedback values
Allows a convenient control of the different parameters and setting values
Allows a fast and clear notification of the different alarms
This solution is optimized because:
Can be simply added on top of your current installation
Very small dimension so can be installed close to the controlling device for or local control
Internal graphics and control functions for standalone application without need of server or OS
licensing.
1.2 Solution components and version
Hardware / Software
Version
Note
Ms Windows
Win 7
GP-Editor
v4.01 (build 023)
Autonics product. Release 2016.10.13
GP-S070 T9D6
Firmware v1.20
Autonics product. Release 2016.01.26
XG-5000
v4.20
LS product. Release 2017.03.24
XBM-DN32S(Cnet)
LS product
Serial Cable
Autonics ref. C3M5P03-D9M0-W4*0

1 Solution Overview
10 © Copyright Reserved Autonics Co., Ltd.
1.3 Solution architecture
1.4 Communication cable pin details and dimensions
(Autonics model: C3M5P03-D9M0-W4*0)

1 Solution Overview
© Copyright Reserved Autonics Co., Ltd. 11

2 GP-S070 Communication Settings
12 © Copyright Reserved Autonics Co., Ltd.
2GP-S070 Communication Settings
The GP device should be set to use its RS422 port and to control data registers of a XBM type device.
So we need:
- to create a GP-Editor project with XBM connection and different graphical
components to interact with the XBM registers
- to set communication parameters of the GP device to allow a connection with the
PC and GP-Editor
- to send the GP-Editor project to the GP device
- to check the serial communication settings of the GP connection with the XBM PLC.
Remarks:
In this document, we will use an Ethernet connection to download the GP-Editor project to the GP
device, please refer to the ‘GP-Editor Download Manual’ if you want to use another method (serial
connection or USB connection).

2 GP-S070 Communication Settings
© Copyright Reserved Autonics Co., Ltd. 13
2.1 GP-Editor project settings
Run the GP Editor software and select [Project] –[New] in the menu bar. If you already build a1st
project file, open this project by selecting [Project] –[Load] in the menu bar.
In the ‘GP/PLC Type’dialog box, set ‘GP/LP Type’, CH1/2 ‘Group’ and ‘Type’ as bellow then click 2nd ‘OK’.
In the ‘Project Auxiliary Property’dialog box click ‘OK’. The graphic editor page will be displayed.3rd
The project has been properly initially set. Then you need to create your own graphics and4th set links between GUI components and the XBM PLC registers.
Rem: Please refer to the ‘GP-Editor User Manual’ document for procedures on graphics creation or to the
example section of this document for a simple interface example.
Item
Settings
GP / LP Type
GP-S070 T9D6
CH1 Group / Type
No Use
CH2 Group / Type
LS XGB SERIES /
XBMDR16_CPU_Cnet

2 GP-S070 Communication Settings
14 © Copyright Reserved Autonics Co., Ltd.
2.2 GP-S070 Ethernet communication settings for GP-
Editor
First check the computer IP settings:1st
On the PC, go to [Control Panel] –[Network and Sharing Center] –[Local Area Connection] –[Properties],
click on ‘Internet Protocol Version 4 (TCP/IPv4) and ‘Properties’.
Note your IP address and default gateway to later set properly the GP address.2nd

2 GP-S070 Communication Settings
© Copyright Reserved Autonics Co., Ltd. 15
On the GP-S070 device, click on the top-left of the screen to open the ‘System Setting’ menu.3rd
Rem: if the ‘System Setting’ menu does not appear, the default menu shorcut has been changed. Try to
click on the other corner of the touch panel or refer to the ‘GP-S070 - User Manual’.
Select ‘Environment’.4th

2 GP-S070 Communication Settings
16 © Copyright Reserved Autonics Co., Ltd.
Select ‘Local Ethernet’.5th
Set the Ethernet settings as below:6th
Items
Settings
Comment
IP Address
169.192.1.12
With last digit unique number on the network
Station
255.255.255.0
Same that the PC
Device
169.192.1.1
Same that the PC

2 GP-S070 Communication Settings
© Copyright Reserved Autonics Co., Ltd. 17
Click on ‘CLOSE’ to validate the changes.7th

2 GP-S070 Communication Settings
18 © Copyright Reserved Autonics Co., Ltd.
2.3 Send GP-Editor project to GP-S070 device by Ethernet
In GP-Editor, select the [Communication] –[Download] menu, and click on ‘Setting’.1st
In the ‘Option’ window, select ‘Ethernet’ and write the GP IP address in the ‘Target IP’ or2nd automatically look for your device by selecting the good ‘LANCard IP’, clicking on the ‘Refresh’
button and selecting the device that appears int the result table.
Click on ‘OK’ to validate the connection method and to go back to the download page. Then click3rd on ‘Download’ and ‘Yes’ to start loading the project in the GP device.
The project has been loaded in the GP device.4th

2 GP-S070 Communication Settings
© Copyright Reserved Autonics Co., Ltd. 19
2.4 GP-S070 serial communication settings for XBM PLC
Click on the top-left of the GP-S070 to open the ‘System Setting’ menu.1st
Rem: if the ‘System Setting’ menu does not appear, the default menu shorcut has been changed. Try to
click on the other corner of the touch panel or refer to the ‘GP-S070 - User Manual’.
Select ‘Environment’.2nd
Click on ‘Serial Communication’.3rd

2 GP-S070 Communication Settings
20 © Copyright Reserved Autonics Co., Ltd.
In the ‘Serial’page, set the port parameters as below by clicking on the different values.4th
PROTOCOL
PORT
CH1
No Use
RS-232C
SET
CH2
XBMDR16_CPU Cnet V
1.5M
RS-422
SET
And GP Station address: 0
Change the communication settings by clicking the ‘SET’ button and setting parameters as below.5th Then click on ‘CLOSE’.
Item
Setting
Note
Baud rate
Multiple choice
User setting
Data length
8-bit
User setting
Parity bit
None
User setting
Stop bit
1-bit
User setting
Flow control
XON/XOFF
Any value
The GP-S070 is ready to be connected to the XBM PLC by its RS422 communication port.6th