Function Descriptions
Function 0:
This function is disabled ~ Normal Mode (Default)
Function 1:
Relay 1 will turn off for 10 seconds and turn on again. After 30 seconds, Relay 2 will be off
for 5 seconds and turn on again.
Function 2:
At a programmable time section, Relay 1 or 2 will turn off for a programmable time (in
seconds) and turn on again.
Note: Once this function is used, the relays will operate automatically according to the
programmed time. Activation of relays with call will not work this time.
(For further setting of time and operating time please refer to 5.3.2 and 5.3.3)
To program the output relays to operate with function 2, the syntax of the command is the
following:
#PWD123456#FTRY=2
Relay operate at programmable time
The output relay can be programmed to operate at a programmable time. To program this
function, you can send the following commands by SMS message to the unit.
#SMW=SS, MM, HH, TTT, G, R;
SS is a 2 digits value stand for seconds
MM is a 2 digits value stands for minutes
HH is a 2 digits value stand for hours
TTT is a 3 digits value stands for Turn Off time in seconds
G stands for Group number 1- 8
R stands for Relay number 1or 2
Example 1, assume you want the output relay number 1 to turn off for 20 seconds at
8.30am, you should send the following SMS message to the unit.
#PWD123456#SMW=00,30,08,020,1,1;
Example 2, assume you want the output relay number 2 to turn off for 30 seconds at
5.30pm, you should send the following SMS message to the unit.
#PWD123456#SMW=00,30,17,030,1,2;
Note: You can program up to 8 groups of time sections for each relay.
System time setting
To set the time, you can send the following SMS command to the unit. The time is entered
in a 24 Hour format.