Avaya VSP 4850 GTS DC User manual

2Unpack the equipment and verify
package content
Confirm that you have the following tools and cables:
• Phillips #2 screwdriver
• Console cable to match the console connector on the
switch (DB-9 or RJ-45)
• ESD cable
Virtual Services Platform
4000 4850GTS Series
Quick Install Guide
Avaya
1. Avaya Virtual Services Platform (VSP) 4000 Series switch with
one power supply installed.
2. Rack-mounting hardware that includes:
a. Rack-mount brackets
b. Screws to attach brackets to the switch
c. Screws to attach the switch to the equipment rack
3. Rubber footpads
4. AC power cord with an IEC 60320 C16 connector.
(Note: A power cord is not included for the A variant of
the switch.)
5. Documentation that includes the following:
a. Locating the latest software and product
Release Notes (NN46251-106)
b. The Regulatory guide (NN46251-105)
c. The Quick Install guide (this document)
d. The China RoHS paper.
1Before you start
This document provides information and instructions to
install and commission a factory-supplied Avaya Virtual
Services Platform 4000 switch. You can download all docu-
ments referenced in this guide at www.avaya.com/support.
Optionally order a redundant PSU to provide redundancy, load
sharing, and add Power over Ethernet Plus (PoE+) power budget
on PWR+ models.
VSP 4000 AC power specifications
(VSP 4850GTS and VSP 4850GTS-PWR+):
Note: Both the 300W and 1000W AC power supplies use the IEC
60320 C16 AC power cord connector.
The VSP 4000 Series switch supports two field-replaceable power
supplies. One power supply is installed. You can optionally install a
redundant power supply. The VSP 4000 switch comes in AC and
DC power variants.
Use this procedure to install a redundant power supply.
Note: The switch ships with a filler panel in the second power
supply position. This filler panel must stay in place if you do not
intend to install a second power supply.
If you mount the VSP 4000 switch on a table or shelf, attach the
rubber feet to the device as indicated. The surface must support
the combined weight of the switch and attached cables (from 15
to 20 pounds [7 to 9 kilograms]).
Set the device on a flat surface near an AC power source,
making sure there is at least 2 inches (5.1 cm) of space on all
sides for proper air flow, and at least 5 inches (12.7 cm) at the
back for power cord clearance.
b. Rack mounting
3.
Slide the switch into the rack as illustrated. Insert and tighten the
rack-mount screws.
Note: Observe ESD precautions when unpacking.
3Verify power supply unit (PSU)
specifications
VSP 4000
model
Primary
PSU
Redundant PSU
(to be ordered if required)
VSP 4850 GTS
300w AC
power supply
(replacement
order code:
AL1905?08-E5)
300w AC power supply
(order code: AL1905?08-E5)
Note: The seventh character (?) of the
switch order number must be replaced
with the proper letter to indicate desired
product
nationalization.
•“A”: No power cord included.
• “B”: Includes European “Schuko”
power cord common in Austria,
Belgium, Finland, France, Germany,
The Netherlands, Norway,
and Sweden.
• “C”: Includes power cord commonly
used in the United Kingdom
and Ireland.
• “D”: Includes power cord commonly
used in Japan.
• “E”: Includes North American
power cord.
• “F”: Includes Australian power cord.
VSP 4850
GTS-PWR+
1000w AC PoE+
power supply
(replacement
order code:
AL1905?21-E6)
1000w AC power supply
(order code: AL1905?21-E6)
PoE+ specifications:
Maximum PoE+ Wattage:
• 855W with one power supply
• 1855W with two power supplies
Average PoE+ Wattage on 50 port models:
• 15.4W (802.3af)
• 17.8W (802.3.at) — 1 power supply
• 32.4W (802.3at) — 2 power supplies
The VSP 4850GTS-PWR+ can support 802.3af 15.4W on
each port with one power supply installed.
PoE+ power reduces to an average of 17.8W on each port
with one power supply. It can support 802.3at 32.4W on
each port with two power supplies installed.
VSP 4000 DC power specification (VSP 4850GTS):
VSP 4000 model Primary PSU Redundant PSU
VSP 4850
GTS DC
300w DC power supply
(replacement order code:
AL1905?05-E5)
300w DC power supply
(order code:
AL1905?05-E5)
DC Power supply specifications:
• Input voltage: 48 V DC
• Input current: 10 A
• Output voltage: 12 V DC
• Output current 25 A
4(Optional) Install redundant
power supply unit
1.
If a blanking plate covers the required power supply slot,
remove the blanking plate before attempting to insert the
power supply.
2. Insert the power supply into a rear power supply slot as
shown below:
3. Verify that each power supply is fully seated in the slot.
Secure the power supply with the two thumb screws.
Note: The switch chassis can prevent an incorrect installation
of a power supply. If you insert a power supply upside down, it
will not fully insert and the thumb screws will not engage.
4. After you install a power supply, proceed with connecting
AC power.
5Mount the VSP 4000 switch
a. Table or Shelf mounting
Prepare the rack:
1. Provide the equivalent of one RU of vertical space for each
switch in an EIA or IEC-standard 19-inch (48.2-centimeter)
equipment rack.
Ensure that the equipment rack is stable and securely attached
to a permanent structure.
2. Ground the rack to the same grounding electrode used by the
power service in the area. The ground path must be permanent
and must not exceed 1 ohm of resistance from the rack to the
grounding electrode. AVAYA recommends using a filter or
surge suppressor.
Mount the switch:
1. Remove the screws that hold the USB cover for rack mounting,
but do not remove the USB cover.
Caution: Do not remove the USB
device from the slot. This can
seriously affect switch operation and
may even cause the switch to not
boot up. Ensure that the USB device
is inserted at all times, with the USB
cover on.
2. Attach a bracket to each side of the switch using the #2 Phillips
screw-driver as illustrated. The bracket goes over the USB cover.
For more details on installing the VSP 4000 Series, see
Installing the Avaya Virtual Services Platform 4000
VSP4850GTS Series (NN46251-300).
1
2
3
4
5
6
7
8
11
12
9
10
13
14
15
16
17
18
19
20
23
24
21
22
25
26
27
28
29
30
31
32
35
36
33
34
37
38
39
40
41
42
43
44
47
48
45
46
4850GTS-PWR+
1
2
3
4
5
6
7
8
11
12
9
10
13
14
15
16
17
18
19
20
23
24
21
22
25
26
27
28
29
30
31
32
35
36
33
34
37
38
39
40
41
42
43
44
47
48
45
46
4850GTS-PWR+
PWR
RPS
Up
Down
Base
USB
Speed
Speed
V
S
P
PWR
Status
RPS
Up
Down
Base
USB
Speed
Speed
V
S
P
1
2
3
4
5
6
7
8
11
12
9
10
13
14
15
16
17
18
19
20
23
24
21
22
25
26
27
28
29
30
31
32
35
36
33
34
37
38
39
40
41
42
43
44
47
48
45
46
4850GTS-PWR+
1
2
3
4
5
6
7
8
11
12
9
10
13
14
15
16
17
18
19
20
23
24
21
22
25
26
27
28
29
30
31
32
35
36
33
34
37
38
39
40
41
42
43
44
47
48
45
46
4850GTS-PWR+
Commissioning the VSP 4000
Property Value
Baud Rate 9600 bps
Data Bits 8
Stop Bits 1
Parity None
Flow Control None
http://support.avaya.com
1-800-242-2121 (U.S.A.)
1-866 GO-AVAYA
1-866-462-8292 (US Sales)
© 2016 Avaya Inc.
Poster part number: 700508202 Rev.04
NN46251-302, 05.01
Caution: Before you unplug the AC power cord, always
perform the following shutdown procedure. This procedure
flushes any pending data to ensure data integrity.
1. Enter the Privileged EXEC command mode:
enable
2. Shutdown the VSP 4000:
sys shutdown
3. Before you unplug the power cord, wait until you see the
following message:
System Halted, OK to turn off power.
For more information on this and other administration
procedures, see Administering VSP Operating System
Software (NN47227-600).
1.
Connect the AC power cord to the back of the switch, and then
plug the other end of the cord into an AC power outlet.
Note: You will need two power cords if you have installed a
redundant PSU.
Warning: You must use a power cord set approved for the 4000
Series switch and the power receptacle type in your country.
2.
Check the front-panel LEDs as the device powers on to be sure
the PWR LED is lit. If not, check if the power cord is plugged in
correctly. The switch will power on immediately when it is
connected to a suitable AC power source.
6Power Up
Note: Before installing, ensure the switch is up and running, and
operating normally. Verify that the SFP or SFP+ transceivers and
network cabling support your network configuration.
1. Remove the transceiver from the protective packaging.
2. Verify that the transceiver is the correct model for the
network configuration.
3. Grasp the transceiver between your thumb and forefinger.
4. Insert the transceiver into the proper SFP/SFP+ slot on the
switch as illustrated. Apply a light pressure to the transceiver
until it clicks and locks into position in the slot.
7Install SFP and SFP+ transceivers
Console port cabling specifications:
Ensure the use of Category 5E or higher specification cabling
for 1 Gbps/1000 Mbps operation. RJ-45 console port cables
are as follows:
Connector Pin Number Signal
1
2
3
4
5
6
7
8
9
Carrier detect (not used)
Transmit Data (TXD)
Receive Data (RXD)
Data terminal ready (not used)
Signal ground (GND)
Not used
Request to send (not used)
Not used
Ring indicator (not used)
RJ–45 Console port pin assignments
Connector Pin Number Signal
1
2
Ready to send (RTS) — optional
Data terminal ready (DTR) —
optional, can swap or link with pin 8
3
4
5
6
7
Transmit data (TXD) — mandatory
Carrier detect (DCD) — optional
Ground (GND) — mandatory
Receive data (RXD) — mandatory
Data set ready (DSR) — optional
8 Clear to send (CTS) — optional,
can swap or link with pin 1.
Note: In the following procedure you create a VLAN with
ID 20 and name Avaya.
1. Create a VLAN:
VSP-4850GTS-PWR+:1(config)#vlan
create 20 name Avaya type port
2. Add VLAN members:
VSP-4850GTS-PWR+:1(config)#vlan members add 20 1/4
3. Configure a management IP interface for the VLAN
(for example, 47.17.123.85)
VSP-4850GTS-PWR+:1(config)#interface vlan 20
VSP-4850GTS-PWR+:1(config)#ip address
47.17.123.85 255.255.255.0
1. Connect the console cable from the terminal to the console
port of the switch to allow initial configuration. Any terminal
or PC with the appropriate terminal emulator can be used as
the management station.
2. Set the terminal protocol on the terminal or terminal
emulation program to VT100 or VT100/ANSI.
3. Connect to the switch using the terminal or terminal
emulation application.
Terminal emulation settings
PEC Code Name Short Description
Avaya RJ-45/DB-9
CONSOLE CABLE
The VSP 4000 has an RJ-45 female
connector, so a serial cable with
RJ-45 connectors, or a serial cable
with a DB-9 female connector on
one end and an RJ-45 on the other
is appropriate.
The maximum length for the console
port cable is 25 feet (8.3 meters).
Converts DB-9 MALE to RJ-45 serial
port. The adaptor can be used for
PC or device with DB-9 MALE
console port. Also, can be used with
Category 5 RJ-45 straight cable to
provide console connection.
Converts DB-9 FEMALE to RJ-45
serial port. This adaptor can be used
to convert DB-9 of AL2011013-E6
console cable to RJ-45.
AL2011022-E6
AVAYA RED DB-9
FEMALE TO
RJ-45 ADAPTOR
AL2011020-E6
AVAYA BLUE
DB-9 MALE TO
RJ-45 ADAPTOR
AL2011021-E6
On your VSP 4000 switch, the console port is the RJ-45 port
outlined with a blue border on the front of your switch (note
orientation). Use an RJ-45 to DB-9 cable to connect the switch
console port to your management terminal. Use adaptors to
provide different connection options. The maximum length of a
console cable is 25 feet (8.3 meters). The following tables
describe the RJ-45 and DB-9 console port pin-out information.
You can use the pin-out information to verify or create a
console cable for use with your maintenance terminal.
DB–9 Console port pin assignments
1Connect the console cable to the VSP 4000
2Configure an in-band VLAN and a
management IP interface for the VLAN
For more information, go to http://support.avaya.com and
download the following VSP 4000 guides:
•
Regulatory Information (NN46251-105)
•
Locating the latest software and product Release Notes
(NN46251-106)
•
Documentation Reference, NN47227-100
•
Installation (NN46251-300)
•
Quick Start Configuration, NN47227-102
•
Release Notes (NN47227-401)
•
Administration (NN47227-600)
Shutting down the VSP 4000
Recommended reading

This manual suits for next models

2

Other Avaya Network Accessories manuals

Avaya 4850GTS Series User manual

Avaya

Avaya 4850GTS Series User manual

Avaya Definity G3 Series Quick start guide

Avaya

Avaya Definity G3 Series Quick start guide

Popular Network Accessories manuals by other brands

StarTech.com CTK400LAN installation manual

StarTech.com

StarTech.com CTK400LAN installation manual

TRENDnet TEG-MGBS10D35 Specifications

TRENDnet

TRENDnet TEG-MGBS10D35 Specifications

Hama 00042912 operating instructions

Hama

Hama 00042912 operating instructions

Extreme Networks Altitude 300-2 Getting started guide

Extreme Networks

Extreme Networks Altitude 300-2 Getting started guide

Black Box ME540A-ST Specifications

Black Box

Black Box ME540A-ST Specifications

Black Box MT136A Specifications

Black Box

Black Box MT136A Specifications

brennenstuhl RC 3600 instruction manual

brennenstuhl

brennenstuhl RC 3600 instruction manual

Net to Net Technologies UIM-1000 installation instructions

Net to Net Technologies

Net to Net Technologies UIM-1000 installation instructions

Lanner NCA-1526 user manual

Lanner

Lanner NCA-1526 user manual

Asus AAEON FWS-2365 user manual

Asus

Asus AAEON FWS-2365 user manual

Auerswald TSA-a/b Operation guide

Auerswald

Auerswald TSA-a/b Operation guide

ZyXEL Communications NetAtlas user guide

ZyXEL Communications

ZyXEL Communications NetAtlas user guide

Actisense QNB-1-B user manual

Actisense

Actisense QNB-1-B user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.