AviteQ Vibtronic SC-2 Series User manual

2SHUDWLQJPDQXDO
9,%7521,&
&RQWUROOHU
IRUPDJQHWLFYLEUDWRUV
7\SH6&(«
LQSDQHOPRXQWLQJDQGFDELQHWXQLW

0–1
Connections and display elements
Intended use
The VIBTRONIC SC…-2 and SCE…-2 type controllers are designed and con-
structed as alternating voltage regulators for controlling magnetic vibrators; they
operate on the voltage regulation principle (phase regulation).
The controllers have been designed for use with mains networks having a fre-
quency of either 50 or 60 Hz and a sinusoidal voltage.
Do not use the controllers in environments with explosion hazards (explosives,
gassy environments)! Observe the information regarding the intended uses given
in Chapter 1.3!
Magnetic vibrator connection
Command value inputs
Release
Operating indicators
Trimming potentiometer R1
Mains connection
Command value input commutation
Status relay

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 0–2
For your safety
You will find three different types of symbols in this operating manual which are
intended to point out important information:
The DANGER warning describes procedures or conditions which could have dan-
gerous or even life-threatening consequences for the person installing or using the
equipment.
You will find this information with procedures in which a danger of damage to
equipment exists. However, this may also result in personal injury (e.g. in case of
fire).
Notes provide information about individual procedures. Notes explain circum-
stances, clarify terminology or provide tips for simplifying processes or proce-
dures.
Although we developed the VIBTRONIC controllers taking into account all safety
measures, operational error cannot be completely eliminated. In the interest of
your safety and that of your colleagues, observe the following information:
When connected to mains, dangerously high voltages are present inside the con-
troller. Touching electrically live components can be lethal! Before switching on
mains power, ensure that no live parts can be touched.
Explosions can be life threatening and result in great damage to equipment.
Do not use the controller in environments with explosion hazards.
The controller of type SC(E)…-2 is not designed for environments with explosion
hazards or firedamp environments and must not be used in such without first tak-
ing appropriate measures.
Unsuitable controllers, operation with the incorrect mains voltage/frequency could
result in damage to the magnetic vibrator. Make sure that the connection values
are correct and compare them with the device-type plates!
DANGER!
ATTENTION!
NOTE
DANGER!
DANGER!
ATTENTION!

0–3 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
©2002 AViTEQ Vibrationstechnik GmbH
COPYRIGHT
The SC…-2 and SCE…-2 series VIBTRONIC controllers and this operating manual are protected by copyright.
Any reengineering of the units will result in criminal prosecution. All rights of this Operating Manual are
reserved, including reproduction via photo mechanical, print, data or any other possible medium, as well as in
translation.
Reproduction of this operating manual, complete or in part, requires the written consent of
AViTEQ Vibrationstechnik GmbH.
VIBTRONIC is a registered and protected trademark of AViTEQ Vibrationstechnik GmbH.
This operating manual supports the intended use and appropriate deployment of VIBTRONIC controllers. For
this purpose, the operating manual describes details that are significant for the product's operation. In particu-
lar, the operating manual provides no claim or guarantee of characteristics in the sense specified by §§ 434,
634 BGB (German civil code) or for the success of specific applications.
AViTEQ Vibrationstechnik GmbH is liable for textual errors in the operating manual only where intent and gross
negligence are demonstrated. In such cases, liability is limited to the effects the textual errors have on the prod-
uct specified in the contract and other associated products produced by AViTEQ Vibrationstechnik GmbH as
well as required products produced by AViTEQ Vibrationstechnik GmbH which are used in technical combina-
tion. This aforementioned liability is limited to cases in which the value or functionality of the agreed upon char-
acteristic of the product specified in the contract is vitiated or considerably diminished. This does not apply if
liability for loss of life or limb or loss of health is mandatory.
The textual errors, the damages as well as the justification and resulting causality underlying the liability claim
are to be proven by the purchaser. In particular, AViTEQ Vibrationstechnik GmbH is not liable for damages or
consequential damages resulting from the incorrect use of the operating manual. This does not apply to faulty
content of the operating manual. This does not apply if liability for loss of life or limb or loss of health is manda-
tory. We are always grateful for suggestions and criticism!
Unless otherwise stated, the relevant state of engineering is that at the time of the combined delivery of the
product and the operating manual from AViTEQ Vibrationstechnik GmbH. The product is subject to technical
changes without prior notice. Previous operating manuals no longer apply.
The General Conditions of Delivery Domestic and Abroad of AViTEQ Vibrationstechnik GmbH apply in their cur-
rent version.
Do you have questions? Or problems with installation and commissioning?
Give us a call! We'll be glad to help you!
AViTEQ Vibrationstechnik GmbH
Im Gotthelf 16
D 65795 Hattersheim-Eddersheim
Telephone +49 (0) 61 45 / 503 - 0
Fax +49 (0) 61 45 / 503 - 200
Telefax Service-Hotline +49 (0) 61 45 / 503 - 112
Hattersheim-Eddersheim (Germany), 28. January 2003
2002

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 0–4
Chapter Contents
Not to be forgotten: troubleshooting
Installation and electrical connection
Basics of the controller and its selection:
the function description
General remarks regarding this operating manual, our terms of
business, warranty and areas of application of the controllers
Transport, storage, extent of delivery and disposal
1
2
3
To the point:
Commissioning Step by Step
4
5
6
Prevention is better:
Service and Maintenance
7
8
Seek and find: the Index

Table of Contents
i©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
1 We are Partners 1-1
1.1 About this operating manual ...............................................................................................1-1
1.2 Product Liability and Warranty ............................................................................................1-2
1.3 Areas of Application.............................................................................................................1-4
1.4 Installation and Operating Personnel ..................................................................................1-5
2Transport,Storage 2-1
2.1 Extent of Delivery.................................................................................................................2-1
2.2 Disposal ................................................................................................................................2-2
2.2.1 Packing Materials .................................................................................................................2-2
2.2.2 Returning the Device ...........................................................................................................2-2
2.2.3 Materials Used in the Units..................................................................................................2-3
3 Function Description 3-1
3.1 Sizes......................................................................................................................................3-1
3.2 Principles of Operation and Oscillation Rates.....................................................................3-1
3.3 Scope of Operation ..............................................................................................................3-2
3.3.1 Regulation Types ..................................................................................................................3-2
3.3.2 Command Value Preset........................................................................................................3-2
3.3.3 External Release...................................................................................................................3-2
3.3.4 Operating Messages ............................................................................................................3-3
3.4 Models ..................................................................................................................................3-3
3.4.1 Type Designation..................................................................................................................3-4
4 Installation 4-1
4.1 Mechanical Installation ........................................................................................................4-1
4.1.1 Panel Mounting Unit.............................................................................................................4-1
4.1.2 Cabinet Unit ..........................................................................................................................4-3
4.2 Terminal Assignment ...........................................................................................................4-3
4.2.1 Minimum Terminal Assignment ..........................................................................................4-3
4.2.2 Status Relay..........................................................................................................................4-6
4.2.3 Coarse and fine Fill Rates.....................................................................................................4-6
4.2.4 External Control Input .........................................................................................................4-7
4.2.5 Switching on/off externally..................................................................................................4-9
4.3 Mains connection...............................................................................................................4-10
4.3.1 Notes on electrical connection ..........................................................................................4-10
4.3.2 Connection Diagram ..........................................................................................................4-11
4.3.3 Vibration-Width Adjuster, Rotary-Type Knob and Scale ...................................................4-12
4.4 Electrical connection with the magnetic vibrator .............................................................4-13
4.4.1 Electromagnetic Compatibility (EMC) ...............................................................................4-13
4.4.2 Line lengths ........................................................................................................................4-14
5 Commissioning 5-1
5.1 Commissioning with AViTEQ magnetic vibrator ................................................................5-1
5.2 Commissioning with vibrators from third party manufacturers ........................................5-1
5.2.1 Setting the vibrator nominal voltage...................................................................................5-1
5.2.2 Commissioning ....................................................................................................................5-1
6 Maintenance 6-1
7 Troubleshooting 7-1
7.1 Repairs..................................................................................................................................7-1
7.2 Fault Causes and Remedy ...................................................................................................7-1
8INDEX 8-i
CONTENTS

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 1–1
1
1 We are Partners
1.1 About this operating manual
For whom?
This operating manual is intended for the
l
installation technician who installs and commissions the magnetic vibrator.
l
electrician or engineer who carries out the installation of the controller, the
electrical connection to the mains network and the connection to the mag-
netic vibrator.
All work on the controller must be carried out by qualified personnel (electricians
or persons trained in electrical engineering according to IEC 364 and
DIN EN 60204-1).
Additional Publications
Supplements to this Operating Manual:
l
Connection diagram and dimension sheet for the controller
Definitions
l
Magnetic vibrator: electromagnetic-mechanical unit for operating a vibration
conveyor device
l
Vibration conveyor device: unit consisting of the magnetic vibrator and work-
ing unit (trough, tube, helix, screen etc.)
l
Controller: the separately delivered electronic control unit assigned to the
magnetic vibrator for connecting to the mains network
l
Cabinet unit: controller in compact housing for wall or frame mounting
(type SC…-2)
l
Panel mounting unit: controller for installation in the switching cabinet or in an
enclosed control location (type SCE…-2)
This operating manual applies to the panel mounting unit. Variations specific to the
cabinet unit are indicated at the appropriate points.
Special symbols in this operating manual
Earlier in this manual, you should have learned how we indicate safety notices.
If you have any questions about safe work practices regarding controllers and
their environment, you should give us a call! We do not want you to endanger
yourself or others just because the possible dangers were not clear to you!
NOTE
Date of Revision
On the bottom in the right-hand-side
pages of this operating manual, the ver-
sion number tells you the date when the
page was last updated.

We are Partners – Product Liability and Warranty
1–2 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
For your convenience and orientation, we use the following special indicators in
this Operating Manual:
l
A round bullet indicates a listing of characteristics and conditions.
C
Upward pointing thumbs indicate that you should check something.
F
The pointing finger marks operation steps that you have to carry out.
1.2 Product Liability and Warranty
The controllers correspond to the current State of Engineering and have been
tested for each of its guaranteed functions prior to delivery. AViTEQ
Vibrationstechnik GmbH carries out product and market research to aid further
development and continuous improvement. Should malfunctions or failures occur
despite these preventative measures, please contact our service department! We
guarantee that appropriate measures for the repair of the defect will be taken
immediately.
Conditions of Warranty
We guarantee that the product is free of defects within the scope of the technical
product specifications published by AViTEQ Vibrationstechnik GmbH as well as
technical specifications provided in this operating manual. No declarations of
other product features or claims regarding additional characteristics are provided.
AViTEQ Vibrationstechnik GmbH is not liable for the economic efficiency of the
product or proper functionality when used for applications other than the purpose
defined for the product as specified on the first, right-hand inner page (page 0-1) in
the front of this operating manual.
Warranty Exclusions
Customers and third parties must consult with AViTEQ Vibrationstechnik GmbH
and obtain our prior written consent before undertaking work inside or otherwise
interfering with the product subject to the contract. Otherwise, liability for
devices, persons and other consequential damages of any type to the product
specified in the contract and other legal assets is precluded, provided AViTEQ
Vibrationstechnik GmbH is not co-responsible. Entering into or interfering with the
equipment also renders any warranty null and void.
AViTEQ Vibrationstechnik GmbH does not accept liability beyond the warranty
entitlements stated in our terms of business on which the contract is based. This
applies in particular to claims arising from loss of profit or other damage to pur-
chaser/customer assets. This liability limitation does not apply unless the damage
was intentional or caused through gross negligence and unless liability for loss of
life or limb or loss of health is mandatory. This also does not apply when the pur-
chaser/customer makes a claim for damages based on an incorrect claim of a
characteristic or an agreed-upon characteristic. In the event of culpable violation
of principle contractual obligations, AViTEQ Vibrationstechnik GmbH is also liable
The
General Conditions of Delivery
Domestic and Abroad
of AViTEQ Vibrationstechnik
GmbH apply in their current
version.

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 1–3
1
for criminal intent and gross negligence on the part of non-managing employees
and for mild negligence. In the latter case, this is limited to the contract-typical,
judicious, predicable damages.
Warranty is excluded in particular when the units are used in environments, for
purposes, or connected to power supplies or to control systems that are not suita-
ble for the controllers or that do not represent the common state of technology. In
particular, no warranty is provided for damages caused by unsuitable or incorrect
use, incorrect mounting or commissioning by the purchaser/customer or third par-
ties, natural wear, faulty or careless handling or unsuitable operating materials.
The same applies for replacement parts, chemical, electrochemical or electrical
influences provided they cannot be attributed to AViTEQ Vibrationstechnik GmbH
and its employees. Claims made for damages to objects other than that which is
specified in the contract, so-called deficiency losses, are limited. In this case,
AViTEQ Vibrationstechnik GmbH is liable, regardless of the legal basis, only in the
cases of intent, gross negligence on the part of the owner/of its management or
managing employee in the event of culpable loss of life or limb or health, in the
event of deficiencies which are fraudulently concealed or the absence of which
AViTEQ guaranteed, in the event of deficiencies of the delivered object, provided
liability is provided in accordance with the product liability law for injury to per-
sons and damages to materials or other special legal requirements.
Likewise, no warranty is provided for damages to conveyance and automation
systems which are the result of a malfunction of the product or a textual error in
the operating manual. The warranty excludes damages which are the result of
accessories not supplied or certified by AViTEQ Vibrationstechnik GmbH. AViTEQ
Vibrationstechnik GmbH is not responsible for the violation of patent rights and
other titles of third parties outside of the Federal Republic of Germany.
We would like to point out that we are not liable for damage to the product subject
to the contract, or for consequential damage to other property, if the damage is
caused by non-observation of safety regulations and/or warning notices.
When entering the contract, the purchaser/customer is obliged to point out explic-
itly if the product is intended for private use and will be used by the pur-
chaser/customer predominantly for this purpose.
The VIBTRONIC controllers described in this operating manual must not be oper-
ated without consultation and corresponding release by AViTEQ Vibrationstechnik
GmbH in the United States of America and other countries where US American
laws are applicable.

We are Partners – Areas of Application
1–4 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
1.3 Areas of Application
VIBTRONIC controllers of type SC…-2 and SCE…-2 – hereafter abbreviated with
SC(E)…-2 – make possible the stepless adjustment of the working stroke on the
magnetic vibrator and, thus, of the conveyor rate of vibration conveyor devices.
The controllers must be used together only with AVITEQ magnetic vibrators or
equivalent magnetic vibrators produced by other manufacturers in accordance
with their intended use. Information in the vibration conveyor device and the mag-
netic vibrator operating manuals is also to be observed!
The controllers must only be operated with magnetic vibrators produced from third
party manufacturers when their connection specifications are identical to those of
the AViTEQ magnetic vibrators. For more information, see Chapter 5.2!
The controllers are not intended for any other purposes.
Never use in the following cases:
l
Do not use for operation in environments subject to explosion risk or firedamp
(explosives, (pit-) gas, risk of dust explosion)! The units are not explosion-
protected!
l
Do not use at ambient temperatures below -5 and over +40 °C (cabinet unit)
and +50 °C (panel mounting unit), or in tropical climates or areas where dew
or condensation could form! The units are designed for operation in moderate
climatic environments!
l
Do not use together with magnetic vibrators which are not compatible with
the controllers!
l
Do not use mains networks and mains frequencies other than those for which
the controllers were designed!
l
Do not use at elevations above 1,000 m above sea level without first consult-
ing AViTEQ Vibrationstechnik GmbH!
Connecting to mains and magnetic drives
Only AVITEQ controllers connected to a sinusoidal mains network may be used for
operating the AVITEQ magnetic drives. For each AVITEQ magnetic drive model
there is a corresponding controller.
Other control and connection options are not included.
If a magnetic vibrator is directly connected to mains or an inappropriate controller
is used, the magnetic vibrator may be destroyed. Only use the appropriate control-
ler!
ATTENTION!

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 1–5
1
1.4 Installation and Operating Personnel
Persons involved with installation, commissioning, assembly, disassembly, adjust-
ment or maintenance must have read and understood this operating manual in its
entirety; in particular the safety notes. If you have any questions, we would be
glad to help you!
All work on the controller must be carried out by qualified personnel (electricians
or persons trained in electrical engineering according to IEC 364 and
DIN EN 60204-1).
The controllers may only be serviced by personnel trained and authorised by
AViTEQ Vibrationstechnik GmbH, D-65795 Hattersheim-Eddersheim. AViTEQ
Vibrationstechnik GmbH, Hattersheim-Eddersheim, is not liable for injuries or dam-
age to property if this is not observed. This does not apply if liability for loss of life
or limb or loss of health is mandatory.
Prior to installation and/or
commissioning, you should
familiarise yourself with all
details of the controller and
with the connection options
of the magnetic vibrator. For
more information, see the
chapter in the operating man-
ual on connecting the mag-
netic vibrators.

Transport, Storage –
2–1 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
2 Transport, Storage
l
Delivery: we ship controllers and accessories in purpose-built packaging to
ensure that they reach their destination without damage.
If the packing is visibly damaged in a way that indicates damage to the contents,
contact the forwarding agent! In further proceedings, take notice of the General
Conditions of Business of the forwarding agent in order not to risk your claim for
damages by improperly filled out forms!
F
Storage: unless special agreements concerning packing and storage have
been made, the units, either packed or unpacked, must be stored and trans-
ported under "normal" conditions. This means in enclosed rooms with tem-
peratures between -25 and +65 °C, relative humidity not to exceed 80 %
(no dew or condensation), and no mechanical shocks or vibrations.
Transporting and storing the units under inappropriate conditions may cause per-
manent damage. Such damage may not be detectable from the outside.
AViTEQ Vibrationstechnik GmbH does not cover this case in its warranty and is not
liable for any consequential damage.
2.1 Extent of Delivery
C
After unpacking, compare all parts against the bill of delivery and accompany-
ing documents to ensure that all have arrived and are free of damage. This
includes the controller in the installation or enclosed model itself, the circuit
diagram packed together with the controller and, with installation models,
separate potentiometer with rotary-type knob and scale for setting the work-
ing stroke.
C
Compare the data on the magnetic vibrator and controller type labels with the
delivery invoice and order documents!
C
Check to see that the magnetic vibrator and controller match by referring to
chapter 3.4 of this operating manual! Before using magnetic vibrators pro-
duced by other manufacturers, you must first make certain that the specifica-
tions are suitable for operation with the VIBTRONIC controller (see
chapter 5.2)! If in doubt, contact us! We'll be glad to help you!
NOTE
ATTENTION!

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 2–2
2
Unauthorised combinations may result in destruction of the magnetic vibrator or
controller! Mains voltage, mains frequency and vibration frequency must be identi-
cal! The nominal current of the controller must be the same or greater than the
peak current of the magnetic vibrator. Only connect compatible devices!
2.2 Disposal
2.2.1 Packing Materials
The following materials are used by us for the shipping of controllers, depending
on the mode of transport:
l
Polyethylene foil (PE) for device protection
l
Corrugated cardboard for outer and inner packing
l
Wooden cases for outer packing
l
Paper shavings for filler material
l
Styrofoam (Flo-Pack) for filler and damping material
All packing materials should be disposed of in accordance with local regulations of
the delivery destination.
Cardboard containers and paper packing tapes can be recycled within the RESY
Disposal and Re-utilisation System. Where used, packaging foil, packing tapes,
and foam foils are made from polyethylene (PE), the CFC-free cushions are usually
made from polystyrene foam (PS). These packing materials consist of pure hydro-
carbons and can thus be recycled.
In special cases, we use steel packing bands and wooden cases free of chemical
treatment.
2.2.2 Returning the Device
AViTEQ Vibrationstechnik GmbH takes back without charge controllers of type
SC(E)…-2 delivered in 2002 or later when delivered shipping paid to AViTEQ Vibra-
tionstechnik GmbH, D-65795 Hattersheim-Eddersheim.
ATTENTION!

Transport, Storage –
2–3 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
2.2.3 Materials Used in the Units
In case of disposal by the customer, and when exchanging components, the cur-
rent local waste and disposal regulations apply and should be observed. We
accept no responsibility for improperly disposed of parts and components!
l
For the disposal of the controllers, the regulations for the disposal of elec-
tronic parts and components apply.
l
The power semiconductors used (thyristor and diode module) do not contain
beryllium and thus may be disposed of as electronic waste.
Detailed information concerning the used materials is available from us upon
request. In case of doubt, take advantage of our disposal offer!
NOTE

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 3–1
3
3 Function Description
3.1 Sizes
AVITEQ magnetic vibrators must be operated with the appropriate VIBTRONIC
controllers. Depending on the application and the size of the magnetic drive,
AViTEQ Vibrationstechnik GmbH delivers controllers of series SC(E)…-2 in sizes
"CN", "DN", "EN", or "ES" as either cabinet or panel mounting unit.
3.2 Principles of Operation and Oscillation
Rates
Oscillation Rates and Mains Frequency
Type SC(E)…-2 controllers are alternating voltage regulators and they operate on
the voltage regulation principle (phase regulation).
l
Controllers for vibration conveyor devices with an oscillation rate of
1,500 min-1 (25 Hz) at a mains frequency of 50 Hz and
1,800 min-1 (30 Hz) at a mains frequency of 60 Hz
trigger every fourth mains half-wave.
l
Controllers for vibration conveyor devices with an oscillation rate of
3,000 min-1 (50 Hz) at a mains frequency of 50 Hz and
3,600 min-1 (60 Hz) at a mains frequency of 60 Hz
trigger every second mains half-wave.
The mechanical vibration frequency (25, 30, 50 or 60 Hz) is set at the factory prior
to delivery and is encoded in the type designation.
This new generation of controllers was designed with the EMC directive
(89/336/EWG) in mind and meets the requirements of EN 50081-2 and
EN 50082-2.
Oscillation rates are given in "min-1" and the vibration frequency in "Hz".
NOTE
NOTE

Function Description – Sizes
3–2 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
3.3 Scope of Operation
3.3.1 Regulation Types
The VIBTRONIC Controllers of type SC(E)…-2 are designed for voltage regulation.
Mains voltage fluctuations over a wide range (
10%) have no noteworthy effect
on the working stroke and, therefore, no effect on the conveyor rate.
3.3.2 Command Value Preset
The command value for the working stroke can optionally be preset by means of
l
a vibration-width adjuster (potentiometer) or
l
an external control input (0 … 10 V DC, 4 … 20 mA or 0 … 20 mA)
The working stroke changes proportionally with the command value, i.e.: the
larger the command value, the larger the working stroke.
3.3.3 External Release
The controller can be switched by the electronic release and, therefore, activated
by means of, for example, a PLC (programmable logic controller). This external
release can be made by means of
l
a potential free contact, or
l
a voltage signal of +24 V DC, or
l
an optical coupler.
If an external release is not planned, the appropriate terminals are short-circuited
with a plug-in bridge.
The terminal assignments for the individual connection options are explained in
chapter 4.2.
A plug-in bridge is mounted at the factory which absolutely must be removed in the
case of an external release. The controller may otherwise be destroyed!
NOTE
NOTE
ATTENTION!

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 3–3
3
3.3.4 Operating Messages
For displaying operating states, the units are provided with two LEDs at the top of
the front panel.
The operating condition displays are explained in Figure 3.1.
3.4 Models
The controllers are deliverable in sizes "CN", "DN", "EN", and "ES" in the following
models:
l
Cabinet unit SC… (IP 55): closed compact housing for wall or frame mount-
ing. Vibration-width adjuster and mains switch are installed on the front side
of the housing.
l
Panel mounting unit SCE… (IP 20): controller for installing in switching cabi-
nets or in closed control locations
The corresponding technical data are located in Table 3.2:
SC(E)-C..-2 SC(E)-D..-2 SC(E)-E..-2
Mains frequencies 50 or 60 Hz
Vibration frequencies with 50 Hz mains 25 or 50 Hz
Vibration frequencies with 60 Hz mains 30 or 60 Hz
Nominal voltages with 50 Hz mains
and 60 Hz mains
220 … 240 V
380 … 420 V
440 … 480 V
500 … 520 V
Nominal current 15 A
Maximum power loss
in switching cabinet
45 W
Table 3.2 Technical data for type SC(E)…-2 controllers
LEDs light up, if …
mains voltage is present.
vibrator voltage is present at terminals 3 and 4.
Power on
Run
Operation
(green)
Figure 3.1 Display of operational states by LEDs

Function Description – Sizes
3–4 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
The permissible tolerances are, for the mains voltage,
10.0 % and, for the mains
frequency,
0.5 %.
The vibration frequency is set by the model version and cannot be changed by the
customer.
3.4.1 Type Designation
Explanation of the type designation of the VIBTRONIC controllers of type
SC(E)…-2:
As shown in Table 3.2 (Technical Data), the controllers are designed for various
voltage ranges. Please see the type label for the voltage range of the connector
set.
NOTE
NOTE
Version number
Encoding of the AViTEQ magnetic drive assignments:
Vibration frequency
25
30
50
60
Controller Magnetic Drive
CN MVC …
DN MVD …
EN MVE …
ES MVES …
SC(E)-CN50-2
Panel mounting unit, without "E": cabinet unit
Regulation device type: compact controller with voltage regulation
NOTE

Operating Manual for Controller VIBTRONIC®SC(E)…-2
©2002 AViTEQ Vibrationstechnik GmbH Version 02/2003 4–1
4
4 Installation
4.1 Mechanical Installation
The installation steps for the two versions are described in the following sections:
l
Panel mounting unit, in Chapter 4.1.1 and
l
Cabinet unit, in Chapter 4.1.2
4.1.1 Panel Mounting Unit
The controllers are available as panel mounting units (IP 20 in accordance with
EN 60529) for vertical installation in switching cabinets or control cases. They
consist of:
l
the (closed) panel mounting unit,
l
the potentiometer with rotary-type knob and scale (delivered loose) and
l
the documentation (operating manual, German1)
Prior to installation: before opening the switching cabinet or control case, switch
off the current supply, check that no voltages are present, and protect against
unintentional reconnection!
F
Use the hole pattern to orient yourself, see figure 4.1 on the following page.
The controller can be secured either on the rear or bottom side. When mounting,
ensure that the connection terminals are accessible and the specified minimum
clearances to adjacent devices are adhered to in accordance with Figure 4.1!
F
Fasten the unit to a vibration-free vertical support wall or installation plate in
the closeable switching cabinet (control location); hand-tighten the screws
and use only the intended holes.
F
Install the supplied potentiometer for working stroke adjustment with scale,
rotary-type knob, pointer, and knob cover at a suitable location (e.g. switch-
ing cabinet door or front of control case).
1.Standard, other languages are provided depending on the destination of delivery
DANGER!
NOTE

Installation – Mechanical Installation
4–2 ©1998 AViTEQ Vibrationstechnik GmbH Version 02/2003
Figure 4.1 Panel mounting unit type SCE…-2: protection class IP20, weight approx.
2.2 kg, dimensions and hole pattern for securing to vertical vibration-free
switching cabinet walls or installation plates
D
S
D
S
P
L
Q
L
P
X
P
F
O
H
D
U
D
Q
F
H
PLQLPXPFOHDUDQFH
This manual suits for next models
1
Table of contents
Popular Controllers manuals by other brands

Ascon tecnologic
Ascon tecnologic K49 Engineering manual

Johnson Controls
Johnson Controls SNC Series installation guide

Altronix
Altronix ACM4 Series installation guide

Siemens
Siemens SQM45 Series manual

National Instruments
National Instruments PXIe-8100 installation guide

THOMSON
THOMSON TSC 80E - V2.1 Service manual

M-system
M-system MSP40 instruction manual

Emerson
Emerson Fisher FIELDVUE DVC6200 SIS Instruction manual supplement

Mircom
Mircom OpenBAS-HV-NX10 Series installation manual

Linear Technology
Linear Technology LTC4232 Demo Manual

PG Drives Technology
PG Drives Technology S45A Technical manual

Regin
Regin AQUA24TF instructions