AVT MAGIC DABMUX plus User manual

MAGIC DABMUX plus
DAB/DAB+ Ensemble Multiplexer
Hardware Manual

PAGE 2

PAGE 3
A publication of
AVT Audio Video Technologies GmbH
Nordostpark 91
90411 Nuernberg
Germany
Phone +49-911-5271-0
Telefax +49-911-5271-100
© AVT Audio Video Technologies GmbH
All Rights reserved. Reproduction in
whole or in parts is prohibited without the
written consent of AVT GmbH.
Subject to changes.
Release date: January 20
Version 2.0

PAGE 4

PAGE 5
CONTENT
1Introduction................................................................................................... 7
1.1 Conventions .............................................................................................. 7
1.2 Safety ........................................................................................................7
1.3 General Safety Requirements ................................................................... 8
1.4 Construction..............................................................................................9
1.5 Functionality ........................................................................................... 10
2Putting MAGIC DABMUX plus into operation.............................................. 11
2.1 Mounting ................................................................................................ 11
2.2 Connection to the main voltage..............................................................11
2.3 Operational elements at the rear side....................................................12
2.4 Operational elements on the front side..................................................12
2.4.1 LEDs................................................................................................12
2.4.2 Display............................................................................................12
2.4.3 Rotary Knob ................................................................................... 13
2.4.4 Keypad ...........................................................................................13
2.5 Wiring of the system...............................................................................14
3The web interface of MAGIC DABMUX plus ................................................ 15
4Interfaces ..................................................................................................... 17
4.1 LAN1 … LAN 3 Interfaces........................................................................17
4.2 USB Interfaces.........................................................................................17
4.3 SD Card Slot.............................................................................................18
4.4 External +12V Power Supply Input..........................................................18
5Optional Modules ........................................................................................ 19
5.1 ETI Module.............................................................................................. 19
5.2 Dual LAN Interface Module.....................................................................20
6Technical Data.............................................................................................. 21
7General ........................................................................................................ 23
7.1 Scope of delivery..................................................................................... 23
7.2 Order numbers........................................................................................23
7.3 Software Options .................................................................................... 23
7.4 Declaration of conformity.......................................................................23
8Service Information...................................................................................... 25
8.1 Software and Firmware Updates ............................................................25
8.2 Support ...................................................................................................25
8.3 Repairs ....................................................................................................25
9List of figures................................................................................................ 27

PAGE 6

PAGE 7
1INTRODUCTION
MAGIC DABMUX plus is a DSP-based Ensemble Multiplexer in accordance with
standard ETSI EN 300401 V2.1.1 –optimized for medium and large DAB
headends. Up to 25 program providers can be connected via external Audio
Encoders. The configuration of the system can be carried out via a web browser.
MAGIC DABMUX plus is available as 19” system with an integrated power supply.
1.1 Conventions
In this manual the following conventions are used as text markers:
The TIP symbol marks information which facilitates the operation of the system
in its daily use.
The Note symbol marks general notes to observe.
The Attention symbol marks very important advice that is absolutely to observe.
In case of non-observance malfunctions and even system errors are possible.
1.2 Safety
The unit described has been designed to the latest technical parameters and
complies with all current national and international safety requirements. It
operates on a high level of reliability because of long-term experience in de-
velopment and constant and strict quality control in our company.
In normal operation the unit is safe.
However –especially if daily routine and technical errors coincide –some po-
tential sources of danger for person, material and optimal operation remain.
This manual therefore contains basic safety instructions that must be observed
during configuration and operation. It is essential that the user reads this manual
before the system is used and that a current version of the manual is always kept
close to the equipment.

PAGE 8
1.3 General Safety Requirements
To keep the technically unavoidable residual risk to a minimum, it is absolutely
necessary to observe the following rules:
•Transport, storage and operation of the unit must be under the
permissible conditions only.
•Installation, configuration and disassembly must be carried out only by
trained personal on the basis of the respective manual.
•The unit must be operated by competent and authorised users only.
•The unit must be operated in good working order only.
•Any conversions or alterations to the unit or to parts of the unit
(including software) must be carried out by trained personnel
authorised by the manufacturer. Any conversions or alterations carried
out by other persons lead to a complete exemption of liability.
•Only specially qualified personnel are authorised to remove and
override safety measures, and to carry out the maintenance of the
system.
•External software is used at one’s own risk. Use of external software
can affect the operation of the system.
•Use only tested and virus-free date carriers.

PAGE 9
1.4 Construction
The functions of the MAGIC DABMUX plus are integrated in a full 19” x 1U
housing with an including a wide-area power supply as well as an internal fan.
Figure 1: MAGIC DABMUX plus Front View
Figure 2: MAGIC DABMUX plus Rear View with Dual LAN Module

PAGE 10
1.5 Functionality
MAGIC DABMUX plus is implemented on a signal processor-based hardware
platform which is assembled in an optimised way and achieves best values in
terms of power consumption and reliability. Despite its size, all features such as
re-configuration (manually and scheduled), extraction of Sub Channels of other
Multiplexers, integration of PAD and NPAD data services, creation of Service
Information etc. are integrated.
Up to 25 program providers can be connected via external Audio Encoders. An
installation of the Encoders directly in the studio avoids effectively an
interference in Audio quality because of Codec cascading.
Audio Services can be supplied via the AVTMUX or the EDI(ETI) protocol from
external Multiplexers. As output signal the Multiplexer supplies an EDI signal for
transmission to the transmitters.
The synchronisation is done via NTP.
The configuration, operation and monitoring are carried out via a HTML5 web
browser. An alarm can also be signalled via SNMP.
The system has three GBit Ethernet network interfaces, each allows the
configuration of up to three IP addresses as well as VLANs.
For later extensions two USB 2.0 interfaces as well as an SD Card Slot are
available.
The module slot can be equipped with the optional Dual LAN Interface Module
(ID: 800021) or the optional ETI Module (ID: 470100).
The integrated mains supply is designed as a wide-range power supply (100 -
230V AC). A redundant power supply is possible via the 12V DC voltage input. An
external 12V table power supply (ID: 490222) is optionally available.
The maximum power consumption is less than 30W.
Figure 3: DAB/DAB+ Headend

PAGE 11
2PUTTING MAGIC DABMUX PLUS INTO OPERATION
2.1 Mounting
With its dimensions (W H D) of 430 mm 44,45 mm (1 U) 225 mm the
MAGIC DABMUX plus system can be used either as desktop device or mounted
in 19-inch racks. Mounting brackets are included in the scope of delivery.
When mounting the unit please keep in mind that the bending radius of the
connected cables is always greater than the minimum allowed value.
Although the system has an integrated fan for proper cooling, it is recommended
to have sufficient ventilation. The ambient temperature of the system should be
within the range of +5C and +45C. This threshold is specially to observe if the
system is inserted in a rack.
The temperature of the system can be displayed via the System Monitor of the
web interface.
During operation humidity must range between 5% and 85%.
Incorrect ambient temperature and humidity can cause functional deficiencies.
Operation outside the threshold values indicated above leads to a loss of
warranty claim.
2.2 Connection to the main voltage
The system can be operated with mains voltage in the range of 100V and 230V
AC. The mains frequency can range from 45 Hz to 65 Hz. The maximum power
consumption is 30W.
After switching on the system, the unit boots in a few seconds.

PAGE 12
2.3 Operational elements at the rear side
The system has three buttons at the rear side.
•B1: Press at power on for factory reset
•B2: Press at power on for boot loader start (192.168.96.102/24)
•RST: Short press - Reset of the system and boot from Flash EPROM
Long press (> 10 sec) - Reset of the system and boot from
SD card
2.4 Operational elements on the front side
2.4.1 LEDs
The system has two multicolour LEDs:
•POWER Static green
•System is booted
Red flashing
•System is booting
•STATUS Static green
•No alarm
Static orange
•Indicates a pending warning
Static red
•Indicates a pending alarm
2.4.2 Display
The colour display (LCD) has a resolution of 320 x 240 pixels and is used for basic
configuration (e.g. IP address) and display of the system status.
Figure 4: Front Panel

PAGE 13
2.4.3 Rotary Knob
The rotary knob is used for fast scrolling through menus and selecting elements
(e.g. letters).
Selection is made by pressing the knob.
2.4.4 Keypad
•OPT Key
oTo select the options of a menu
•ESC Key
oTo cancel the last configuration or jump to the previous menu
•INFO Key
oDisplays the system status
•MENU Key
oOpens the configuration menu
•0 …9 / * / # Key
oFor entering of digits e.g. IP address

PAGE 14
2.5 Wiring of the system
The wiring of MAGIC DABMUX plus is simple as possible.
For the actual release 1.0 the following assignment is valid:
•LAN 1
oDefault IP Address: 192.168.96.102
Subnet Mask: 255.255.255.0
oEmbedded Basic Web Interface for Firmware Updates
•LAN 2
oDefault IP Address: 192.168.96.103
Subnet Mask: 255.255.255.0
oWeb Interface for DAB Multiplexer application
EDI, AVTMUX, NTP, SNMP and Configuration
•LAN 3
oCurrently no function

PAGE 15
3THE WEB INTERFACE OF MAGIC DABMUX PLUS
The configuration of the system is described in a separate document
Please note that only one user can access the system via the web browser
simultaneously.
We recommend using one of the following web browsers:
•Firefox (version 47 or higher)
•Google Chrome (version 53 or higher)
•Safari (version 9 or higher), also on iPad or iPhone
•Internet Explorer (version 11 or higher)
After entering the IP address into the address line of your browser you should be
automatically connected to MAGIC DABMUX plus and shows the dashboard.

PAGE 16

PAGE 17
4INTERFACES
4.1 LAN1 … LAN 3 Interfaces
For the three Gbit Ethernet interfaces standard RJ45 socket are used. The pin
assignment of the socket is shown below.
Table 1: LAN1 ... LAN3 Interfaces
Pin
Signal
Description
Electrical characteristics
1
TX+
Data out +
Socket: Western 8 pin, RJ45
Recommendation: IEEE802.3z
1000Base-T
Data rate (Auto neg.): 1 Gbit/s
Recommended cable: CAT5 or higher
Max. cable length: 100 m
2
TX-
Data out -
3
RX+
Data in +
4
NC
Not used
5
NC
Not used
6
RX-
Data in -
7
NC
Not used
8
NC
Not used
4.2 USB Interfaces
The system has two USB2.0 interfaces for future applications.
Table 2: USB Interfaces
Pin
Signal
Description
Electrical characteristics
1
VCC+
+5V
Socket: USB 2.0 Type A
Max. cable length: 5 m
Recommended cable: CAT5 or higher
Max. cable length: 100m
2
DATA-
Data -
3
DATA+
Data +
4
GND
Ground
Figure 5: MAGIC DABMUX plus Rear View with optional Dual LAN Module
Figure 6: MAGIC DABMUX plus Rear View with optional ETI/E1 Module

PAGE 18
4.3 SD Card Slot
The system has one SD Card slot.
The function is currently the alternative booting from the SD card (see chapter
2.3).
Table 3: SD Card Slot
Pin
Signal
Description
Electrical characteristics
1
CD/DAT3
Card/Data 3
Capacity: 2 GB … 32 GB (SDHC)
2
CMD
Commands
3
GND1
Ground
4
VDD
DC 2,7…3,6V
5
CLK
Clock
6
GND2
Ground
7
DAT0
Data 0
8
DAT1
Data 1
9
DAT2
Data 2
4.4 External +12V Power Supply Input
The external power supply input can be used for a redundant power supply. An
optional tabletop power supply is available (ID: 490222).
The type code of the fitting connector is: KYCON KPPX-3P
Table 4: External +12 Power Supply Input
Pin
Signal
Description
Electrical characteristics
1
GND
Ground
Socket: 3 pole, KYCON KPJX-3S-S
Voltage: +12V DC / 2.5A
Power: max. 30W
Recommended cable: CAT5 or higher
Max. cable length: 100m
2
+12V
+12V DC
3
NC
Not used

PAGE 19
5OPTIONAL MODULES
The system can be equipped either with an ETI or Dual LAN interface module.
5.1 ETI Module
The optional ETI Module (ID: 470100) offers one ETI output and one ETI input as
well as one 2.048 MHz clock in-/output.
Table 5: ETI Input
Pin
Signal
Description
Electrical characteristics
1
DATA IN
ETI In
Socket: BNC, female
Amplitude: 3 Vpp/G.703
Impedance: 75 Ωunbalanced
Max. cable length: 100 m
Recommended cable: CAT5 or
higher
Max. cable length: 100m
2
GND
Ground
Table 6: ETI Output
Pin
Signal
Description
Electrical characteristics
1
DATA OUT
ETI Out
Socket: BNC, female
Amplitude: 3 Vpp/G.703
Impedance: 75 Ωunbalanced
Max. cable length: 100 m
Recommended cable: CAT5 or higher
Max. cable length: 100m
2
GND
Ground
Table 7: Clock In-/Output (programmable)
Pin
Signal
Description
Electrical characteristics
1
CLK
2.048 MHz Clock
Socket: BNC, female
Amplitude: 0.5 ... 1.9 V0p In
1.5 V0p Out
Impedance: 75 Ωunbalanced
Max. cable length: 100 m
Recommended cable: CAT5 or
higher
Max. cable length: 100m
2
GND
Ground

PAGE 20
5.2 Dual LAN Interface Module
The optional Dual LAN Interface Module (ID: 800021) offers two additional Fast
Ethernet interfaces with a standard RJ45 socket. The pin assignment of the
socket is shown below.
Table 8: LAN4 ... LAN5 Interfaces
Pin
Signal
Description
Electrical characteristics
1
TX+
Data out +
Socket: Western 8 pin, RJ45
Recommendation: IEEE802.3u
100Base-TX
Data rate (Auto neg.): 100 Mbit/s
Recommended cable: CAT5 or higher
Max. cable length: 100 m
2
TX-
Data out -
3
RX+
Data in +
4
NC
Not used
5
NC
Not used
6
RX-
Data in -
7
NC
Not used
8
NC
Not used
Other manuals for MAGIC DABMUX plus
1
This manual suits for next models
1
Table of contents
Other AVT Multiplexer manuals
Popular Multiplexer manuals by other brands

Ultra electronics
Ultra electronics VersaMux-4000 Operations & installation guide

Carelink
Carelink CL-MC-XE1-IP-Y user manual

Pantron
Pantron IMX-A20 Series operating instructions

Paradyne
Paradyne Hotwire 8799 installation instructions

Raisecom
Raisecom RC3000 user manual

Lucent Technologies
Lucent Technologies Metropolis AMU 2m/4o Applications and Planning Guide