AVVA PRO SMC76 User manual

Remote Control Unit
User’s manual
SMC76
Video conference System
Ver8.30
Please read the instruction carefully before using.

Remote Control Unit
第2页
WARNING!
Do not use such solvent as gasoline or thinner to
wipe the appearance to avoid damage; use a piece
of soft cloth dipped with alcohol or water to wipe
it
1. Do not contact the keyboard with water or other liquids and keep the
appearance clean.
2. The keyboard is only for indoor use. Never expose it in rain or
moisture.
3. The LCD might not perform normally below -10℃.
4. Use the power adapter supply with the keyboard. If a substitute is
required, ensure the power supply is within 9-15V/1000ma.
5. Keep away from fire.
6. Avoid collision or friction with hard objects.
IMPORTANT
This product is manufactured to comply with
requirements of following directives:
89/336/EEC, 92/31/EEC, 93/68/EEC

Remote Control Unit
第3页
Contents
Controllable Equipment ......................................................................1
Technical specifications..........................................................................2
Function Introduction..............................................................................9
Keyboard Instruction..............................................................................10
Fast Operating Guidelines......................................................................15
OperatingApproach................................................................................16
SONY Camera Usage.............................................................................17
Polycom Camera Usage..........................................................................18
Panasonic Camera Usage........................................................................19
Keyboard Setting....................................................................................20
Connecting EVI-D70 Via RS422............................................................20
Connecting EVI-D70 Via RS232............................................................20
Connecting BRC-Z330 Via RS422.........................................................21
Connecting BRC-700 ……….......…………………………………….22
Connecting EVI-HD1/HD3/HD7 Via RS232.........................................23
Connecting Keyboard with Polycom Main Unit....................................24
Connecting Polycom EagleEye Series Cameras.....................................25
Connecting CISCO HD Camera..............................................................26
Panasonic HD AW-HE50/100 Series CameraConnection Graph...........28

Remote Control Unit
第4页
Equipment that can be connected:
BRC-H700/Z700 3CCD Color Video Camera
BRC-300/300P 3CCD Color Video Camera
EVI-D100/D100P/S Color Video Camera
EVI-D70/D70P/W Color Video Camera
EVI-D30/D30P Color Video Camera
SNC-RZ30N/RZ30P Network Camera
SONY EVI-HD1 Camera
EVI-HD3V color Camera
SONY EVI-HD7V HD Camera
BRC-Z330 CMOS Color Camera
Sony DXC-390/390P 1/3 3-CCD
Sony DXC-990/990P 1/2 3CCD Color Camera
Polycom Camera MPTZ-6、MPTZ-9
CISCO Camera 720P/1080P
Panasonic AW-HE50S/H,AW-HE100;AW-PH300-650

Remote Control Unit
第5页
SPECIFICATION
Joystick:3 Axis+1button
Buttons: 28 ALPS button,2color led backlight;
Display: LCD, 2 line,20 characters, blue backlight
Dimensions: 355(L) ×150(W) ×155(H)mm
Weight: 1.47kg (w/o Power supply)
1.89 kg (with Power supply)
2.4kg (prepared for shipping)
Operating Temperature: -10°C - 70°C
Humidity: 30% - 90% (w/o condensation)
Adapter: AC100-240V-12VDC/1000mA
Power consumption: 2.7 W (not loaded line)
Connectors:
RJ45 : matrix or DVR (RS485+RS232)
RS485:connect camera,same as RS422TX,2000M
RS232:connect camera
USB-D: USB2.0 connect PC, server,NVR etc.

Remote Control Unit
第6页
Specifications:
Protocol:VISCA、POLYCOM、CISCO、CANON、Panasonic、PELCOD、PELCO-P;
Bute rate:1200、2400、4800、9600、19200 ;
Channel set protocols and baud rate individually, different protocols can
be set at the same time, maximum 64 Channels.
Preset position stored by keyboards,maximum 64 preset positions of
each channel ;
No.1-16 cameras,64 preset positions stored by keyboard;
No.17-64 cameras,only support existing preset positions
Auto cruise:2-8 preset positions of cruise can be settable,interval 5-100
Seconds;Support 16 cameras,each camera’s cruise can be set
individually;
Visca Protocol address automatic allocation,camera address automatic
searching function
Different brand cameras using simultaneously, automatic switch protocol
and baud rate.
Joystick:
Direction Control:More than 8 directions,0-80 level speed parameters;
Zoom Control:Button ZOOM:0-14 Level Speed
Simultaneous Control: Joystick control direction and zoom
Simultaneously
LCD Display
CAM: 001
>> 0000 MON:001
Camera ID
Input Number Area
Monitor ID

Remote Control Unit
第7页
Keyboard Instruction:
Sensor: Optical Sensor, more than
2 million times;
High Resolution:X、Y axis ±80
Level;Z axis ±14 level
Flexible operate:bearing structure
inside,flexible operate,high sensitivity;
Button LED backlight:
Blue + Red ,blue is the button
backlight,red is the function instruction
Composite Joystick Image:
Button explanation:
CAM:CAMERA
MON:MONITOR
PRESET:Call Preset
SET:Set Preset
DEL:Delete Preset
HOME:HOME
TOUR:Cruise or white balance
SCAN/SEQ:Automatic Pan Scan
MENU:OSD Menu
SAVE :Store/Backlight Compensation
PAUSE :Pause、Image freezing
RUN :run、Image Mirror
FAR:Focus far
NEAR:Focus Near
OPEN:Aperture Open
CLOSE:Aperture Close
ON: AUX ON
OFF: AUX OFF

Remote Control Unit
第8页
Fast operate Instruction:
HOME Press Home,camera return ahead
Set Preset Position Number (1-64)+Set
Delete Preset Position Number (1-64)+Del
Call Preset Position Number (1-64)+Preset
Power On ON
Power Off OFF
Screen Information Display On:99+ON
Screen Information Display Off:99+OFF
Left Right Change:200+ON
Left Right Normal:200+OFF
Up Down Change:201+ON
Up Down Normal:201+OFF
Backlight Compensation [ ]
Image freezing [ ]
Image Mirror [ ]
Run Auto Cruise 1+SEQ”
Switch Camera channel:Number (1-64)+CAM
Switch Monitor channel:Number (1-99)+MON(DVR)
RS232HUB(SMC70SW) Configuration download:1111+CAM
serial number on LCD display:6666+CAM

Remote Control Unit
第9页
Joystick Direction Control
Inclination angle Bigger, Pan tilt speed faster
Zoom Control
ZOOM WIDE ZOOM TELE

Remote Control Unit
第10 页
FOCUS:NEAR
FAR
IRIS:OPEN
CLOSE
Auxiliary Control:
Control on/off/lighting/windshield wiper / water spray/heater/fan etc.
AUX ON:Number (0-254) + ON
AUX OFF: Number (0-254) + OFF
Call Preset:
①Input Number“1-6”(EVI-D70)
②Press “PRESET” button
Set Preset:
①Input Number“1-6”(EVI-D70)
②Press “SET” button
Delete Preset:
①Input Number “1-6”(EVI-D70)
②Press “DEL” button
Back light Compensate:
Press “ ”,once on, twice off
Image Freeze:
Press “ ”,once Image Freeze,twice Image Freeze off, Image
Freeze,Image Motionless
Image Mirror:
press“ ”,once on, twice off. Left right Mirror,position reverse

Remote Control Unit
第11 页
SONY camera using explanation:
1) MENU+9999 enter MENU
2) Protocol=VISCA
3) Baud rate =9600
4) Every camera’s Protocol and Baud rate :VISCA,9600
Eg:Control two Sony cameras
Set CAM-1,CAM-2 VISCA,9600 individually
SONY EVI-D70TECH OperatingApproach
Turn On: ON
Turn Off: OFF
Screen Information on:99+ON
Screen Information off:
99+OFF
Left Right Change:200+ON
Left Right Normal:200+OFF
Up Down Change:201+ON
Up Down Normal:201+OFF
Back light Compensate [ ]
Image Freeze [ ]
Image Mirror [ ]
Run Auto Cruise 1+SEQ”
White Balance Model:
Press [TOUR] Model switch
Six White Balance Models:
Auto
Indoor
Outdoor
One Push WB
ATW
Manual
Screen Information Display Instruction
AUTO WB auto white balance
INDOOR Indoor white balance
OUTDOOR Outdoor white balance
ONE TRIGGER Trigger white balance
ATW WB Auto tracking white balance
MANUAL Manual white balance
WB R GAIN Manual white balance,red gain
WB B GAIN Manual white balance,blue gain
Adjusting Method: Button + Right (+),image color deeper
Button + Left (-),image color lighter

Remote Control Unit
第12 页
Manual white balance :
“Model”=“Manual”
Press “SEQ”, three manual adjusting parameters:
R Gain、B Gain、RB Stop
1 Manual white balance R Gain:
(1)Under Manual white balance Model,press SEQ button,screen
show “R Gain”
(2) Button + Right(+),red deeper,Button + Left (-),red lighter
2Manual white balance B Gain:
(1) Under Manual white balance Model,press SEQ button,
screen show “B Gain”
(2) Button +Right (+),blue deeper,Button +Left (-),blue
lighter
3Manual white balance RB Stop:
(1) Under Manual white balance Model,press SEQ button,
screen show “Gain Stop”
ONE PUSH White Balance
Under ONE PUSH WB Model,press “SEQ” button
SONY BRC-300/300P/HD1 cameras’ MENU Operate Method
Enter Camera Menu: MENU+8888
Enter Next Menu:Joystick up/down
Return Previous Menu or Exit:MENU+8888
Cursor Up Down:Button + up/down
Modify Parameter:Button + Left/Right
Eg:Move Down Menu Cursor
press button on the top of joystick and move down

Remote Control Unit
第13 页
Polycom System
1. Polycom Camera, one conference system with one keyboard. OSD
of keyboard choose Polycom1, baud rate 9600.
2. Connecting HXD8000 conference terminal through RS232.
3. Control up/down/left/right/zoom, set or call preset positions
Polycom Camera
1. Polycom Camera :MPTZ-6,MPTZ-9
2. Choose Polycom 2 and Baud rate 9600 in OSD of the keyboard
3. Connect RS232 of MPTZ-6/9 with RS232 of the keyboard
4. Control up/down/left/right/lens, 64 preset position, power on/off,
Factory Reset, Home.
Operate Method:
1) Enter Menu:Press "MENU" Password:9999
2) Camera: Choose protocol=Polycom2,Baud rate=9600
3) PTZ Control:
Joystick control, operate all functions simultaneously
4) Preset positions:
1-16 cameras,64 preset positions for every Camera
5) (1-16)+CAM Switch Camera Channel
6) (1-64)+SET Set preset position
7) (1-64)+PRESET Call preset position
8) HOME:Camera Ahead
9) ON:Power On
10) OFF:Power Off
11) 1+ON:Infrared On
12) 1+OFF:Infrared Off
13) 100+ON:Factory Reset

Remote Control Unit
第14 页
Panasonic AW-HE50/100 PH300-650
OSD: Protocol= AW-HE50,Baud Rate=9600
PTZ Control:PTZ Control Simultaneously
Direction Control:Pan/Tilt,50 level speed
Zoom Control:50 level speed
Set Preset Positions:N+SET (N=1-100)
Eg:Set 1 preset position
①press “1”
②press “SET”
Call Preset Positions:N+SET (N=1-100)
Eg:Call 1 preset position
①press “1”
②press “PRESET”
Menu:press “MENU” button,enter Password:8888
Fast order:Enter Menu:99+ON
Exit Menu:99+OFF
Auxiliary Function:
N+ON N+OFF (N=1-10)
N= as below
0=power switch ON=power on;OFF=power off
1=Extender/AF Control 0=off 1=on
2=ND Control 0=off 1=on
3=Iris Auto/Manual 0=manual 1=auto
4=Lame Control 0=off 1=on
5=Lame Alarm 0=alarm off 1=alarm on
6=OPTION SW Control 0=off 1=on
7=Defroster Control 0=off 1=on
8=Wiper Control 0=off 1=on
9=Heater/Fan Control 0=off 1=on
10=Tally Control 0=off 1=on

Remote Control Unit
第15 页
Keyboard Setting:
LCD Menu Operating Method:
Switch Menu N01-05:Joystick up or down
Change Parameter:Joystick left or right
Enter Next Menu:Joystick Down
Return Precious Menu:Joystick Up
Parameter + :Joystick Left
Parameter - :Joystick Right
Enter Submenu:Press Button of the Joystick
Return Main Menu: Press Button of the Joystick
LCD OSD
Main Menu (1-5)
1) Button Backlight =5(Off、1、2、3、4、5、6、7、8、9)
2) LCD Backlight =On/Off
3) Camera
Protocol =PELCO-P/PELCO-D/Visca/Cisco/Polycom1/Polycom2/CanonU4/AW-HE50
Baud rate=1200 /2400 /4800/9600/19200
4) PreSeq
Preset =1-2/1-3/1-4/1-5/1-6/1-7/1-8
Intervals =5-100Sec
5) Exit
Enter Menu :
1) Press “MUNU” button
2) Enter Password:9999
Enter Menu,and Screen show as below:
Button

Remote Control Unit
第16 页
No1:Backlight (button backlight)
Off;1-10 Level light,10=max
No2:LCD Backlight
No3:Camera---Setup Protocol and Baud rate
Maximum 64 cameras’Protocol/Baud Rate setting. Address
protocol and baud rate can be different.
Ways:
Joystick left right ---Choose camera address,CAM-01 to CAM-64
Press Joystick “Button”, enter next menu/return precious menu
Press Joystick “Button”
Joystick up down----move cursor
No1:Button Backlight
[6]
No2:LCD Backlight
[on] off
No3:Camera [Visca]
CAM-01 [9600]
>Protocol [Visca]
Baud rate [9600]
Camera ID
Protocol
Baud rate
Protocol
Baud rate
Button
Backlight
luminance1-10

Remote Control Unit
第17 页
Joystick left right ----Change Parameter
Press“Button”of the Joystick----Return Main Menu
No4:PreSeq
(Auto call preset,64 cameras’parameter are settable)
Press Joystick “Button”
Joystick up down----move cursor
Joystick left right ----Change Parameter
Press“Button”of the joystick----Return Main Menu
Notes:1-3 are preset positions ,1、2、3 auto sequence switch,5sec intervals
No 05:Exit
Joystick Left: Exit
Press “MENU”,Exit Menu Setting
No4:PreSeq [1-3]
CAM-01 [ 05] Sec
No05:Exit
>Preset [1-3]
Intervals [05] Sec
Camera ID
Range of Preset
Each preset intervals
Each preset intervals
Range of Preset

Remote Control Unit
第18 页
Connecting Control unit with EVI-D70/D70P via RS422/RS485 viewing:
Connect next device like this

Remote Control Unit
第19 页
Connecting Control unit with EVI-D70/D70P via RS232 viewing:
VISCA RS-232C IN

Remote Control Unit
第20 页
Methods of connecting control unit with BRC-Z330 via RS422/RS485
Noticing:
BRC-Z330 setting:DIP3 ON =RS422,
DIP4 OFF =9600
DIP5-7 OFF =address 0
Connect next device like this
Table of contents