AXEM Technology AT288N User manual

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 1/12
AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 1/1
AT288N User guide
Atid Co., Ltd.
AT288N UI guide
AT288N UI guide
Won-Tak Choi
2016-05-25

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 2/12
AT288N User guide
AT288N UI guide Page 2
AT288N UI guide
AT288N UI guide Corp. Atid Co., Ltd.
Document
Ui guide Writer Won-Tak Choi Date 2016-05-25 Version v0.3
History
Ver. Releasing Date Contents Writer Remark
V0.1 2016-02-24 Draft Won-Tak Choi First Release
V0.2 2016-04-16 Unique Amended Won-Tak Choi Modified
V0.3 2016-05-25 LED Indicator Re-Defined Won-Tak Choi Modified

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 3/12
AT288N User guide
AT288N UI guide Page 3
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
Contents
1 Description for Main Function ....................................................................................................................................5
Protocol.....................................................................................................................................................................5
Remote control......................................................................................................................................................5
RF Power Control .................................................................................................................................................6
Beep............................................................................................................................................................................6
Data storage...........................................................................................................................................................6
Inventory mode.....................................................................................................................................................6
Output Format.......................................................................................................................................................7
RFID Inventory Option.......................................................................................................................................7
Firmware mode .....................................................................................................................................................7
UHF Update Mode (To Be Supported).......................................................................................................7
Auto power off ......................................................................................................................................................7
Memory Access.....................................................................................................................................................7
2 LED ...........................................................................................................................................................................................8
One / Multi LED....................................................................................................................................................8
Scan LED...................................................................................................................................................................8
SPP / BLE LED ........................................................................................................................................................8
RF Control Window LED ...................................................................................................................................8
Power LED................................................................................................................................................................9

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 4/12
AT288N User guide
AT288N UI guide Page 4
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
BT LED........................................................................................................................................................................9
USB LED................................................................................................................................................................. 10
3 Button .................................................................................................................................................................................. 10
Power Key ............................................................................................................................................................. 10
C Key ....................................................................................................................................................................... 11
RF Power Control Left Key............................................................................................................................ 11
RF Power Control Right Key......................................................................................................................... 11
Multi/One Key..................................................................................................................................................... 12
BT/USB Key........................................................................................................................................................... 12
Scan Button.......................................................................................................................................................... 12
Firmware mode .................................................................................................................................................. 12
4 Beep...................................................................................................................................................................................... 12

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 5/12
AT288N User guide
AT288N UI guide Page 5
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
1Description for Main Function
Protocol
It is designated to select neither ISO/IEC 18000-6C or ISO/IEC 18000-6B, but ISO/IEC 18000-
6B is not available at present. It will be supporting in the near future.
Remote control
AT288N can be used by both Bluetooth and USB. For the detailed information, Bluetooth
Protocol can be set up among SPP, HID and BLE (To be supported). Also USB protocol can
be set up by either VCP or HID.
Bluetooth
BTH SPP
The connection can be available using Serial Profile Protocol and Data to be
transmitted will be uploaded to Serial Port (COM Port) of upper level device. Upper
level device should produce the additional program for utilizing the transmitted data.
BTH HID
The connection can be available using Human Interface Device and Data to be
transmitted will be uploaded on the cursor as like Keyboard typing. The caution
should be needed in using the device since the difference between the data read
by actual device and data on the cursor can be occurred in accordance with keyboard
language setting of upper level device
BTH BLE
The connection can be available using Bluetooth low energy and possible to use in
IOS. The reading distance is shorter than existing Bluetooth, but effectivity is better
than existing one.
USB
USB VCP

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 6/12
AT288N User guide
AT288N UI guide Page 6
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
The connection can be available using Serial Profile Protocol and the data to be read
will be uploaded to Serial Port (COM Port) of upper level device. Upper level device
should produce the additional program for utilizing the transmitted data
USB HID
The connection can be available using Human Interface Device and Data to be
transmitted will be uploaded on the cursor as like Keyboard typing. The caution
should be needed in using the device since the difference between the data read
by actual device and data on the cursor can be occurred in accordance with keyboard
language setting of upper level device
RF Power Control
Output power of RFID Module can be controlled by pressing the RF Power Control Left Key
and RF Power Control Right Key. Level is set from 11 to 30.
Beep
When reading the tag or pressing the button, Beep will be working. Beep function can
be power-off state in accordance with user.
Data storage
Not only transmitting the data to remote control in the real time, but also transmitting
the data to remote control at once after saving it in local storage is available.
Inventory mode
One Tag mode
If just one tag is read, this mode will make tag reading stop
Multi Tag mode
In this mode, tag will be continuously reading regardless of duplication
Unique Tag mode
In this mode, tag will be continuously reading like Multi tag mode, but
the difference is that same tag will be reading just once time.

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 7/12
AT288N User guide
AT288N UI guide Page 7
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
Output Format
Serial number
Serial number will be shown in front of the tag
RFID Inventory Option
Selection Mask
Neither random tag only inventories or all tags except for random tags inventory.
Firmware mode
This mode can be possible to set in state of power-off. To work this mode, press scan
button and power key simultaneously. Firmware update for AT288 is available in this
mode and pressing the power key makes it revert to the original state.
UHF Update Mode (To Be Supported)
To work this mode, press RF Power Control Right Key. Firmware for UHF Module is
available in this mode.
Auto power off
For this function, device will be power-off after designated time.
Memory Access
Memory Read
This is the function to read the tag by directly accessing the memory
Memory Write
This is the function to write the tag by directly accessing the memory.
Memory Lock
This is the function to lock the tag by directly accessing the memory.
Tag Kill
This is the function to kill the tag by directly accessing the memory.
If user does tag kill, it is not possible to revert to the tag.

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 8/12
AT288N User guide
AT288N UI guide Page 8
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
2LED
Changing LED state will let user know on setting and event of AT288N
One / Multi LED
In state of One tag mode in Inventory Mode, ONE LED will be turned on and in state
of Multi tag mode in inventory mode, Multi LED will be turned on. in state of Unique
tag mode, both One and Multi tag mode will be turned on.
Scan LED
In state-on for scan button, Scan LED is enable and in state-off, Scan LED is disable. If
inventory is in success, scan LED will be flickered
SPP / BLE LED
In state of neither BTH_SPP or USB_VCP, SPP LED will be turned on and in state of
BTH_BLE, BLE_LED will be turned on. In state of neither BTH_HID or USB_HID, both
LEDs will be turned off.
RF Control Window LED
RF Control Window LED is consisted of 11 pcs of LED. In general, RF Control Window
LED shows the setting value for UHF power.
When showing RF power value
RF Power Window RF Power
●●○○○○○○○○○ 11dBm
○●○○○○○○○○○ 12dBm
○●●○○○○○○○○ 13dBm
○○●○○○○○○○○ 14dBm
○○●●○○○○○○○ 15dBm
○○○●○○○○○○○ 16dBm
○○○●●○○○○○○ 17dBm
○○○○●○○○○○○ 18dBm
○○○○●●○○○○○ 19dBm
○○○○○●○○○○○ 20dBm

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 9/12
AT288N User guide
AT288N UI guide Page 9
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
○○○○○●●○○○○ 21dBm
○○○○○○●○○○○ 22dBm
○○○○○○●●○○○ 23dBm
○○○○○○○●○○○ 24dBm
○○○○○○○●●○○ 25dBm
○○○○○○○○●○○ 26dBm
○○○○○○○○●●○ 27dBm
○○○○○○○○○●○ 28dBm
○○○○○○○○○●● 29dBm
○○○○○○○○○○● 30dBm
Show Bluetooth Protocol settings
RF Power Window Bluetooth Protocol
●●●●●○○○○○○ BTH SPP
○○○●●●●●○○○ BTH HID
○○○○○○●●●●● BTH BLE
Show USB Protocol settings
RF Power Window USB Protocol
●●●●●○○○○○○ USB VCP
○○○●●●●●○○○ USB HID
Show Beep Control settings
RF Power Window Beep Control
●●●●●●○○○○○ Beep disable
○○○○○●●●●●● Beep Enable
Power LED
In Low battery, Power LED will be flickered on cycle of 1000ms (Enable 500ms, Disable
500ms). Also, Power LED will be enable, in case device is charged by connecting neither
USB or AC-DC Adaptor. If charging the device is not finished, there is Red LED. At the
full charging of device, there is Green LED.
BT LED
BT LED is only worked, in case comport is set for Bluetooth. It shows if both remote

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 10/12
AT288N User guide
AT288N UI guide Page 10
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
control and device is set by Bluetooth or not.
Bluetooth Connection on standby
BT LED flickers on cycle of 500ms (Enable 100ms, Disable 400ms)
Bluetooth Connection in Success
BT LED is always on
USB LED
USB LED will be only working on comport to change USB. Please check if both remote
control and device are connected by USB
USB Connection on standby
USB LED flickers on cycle of 500ms (Enable 100ms, Disable 400ms)
USB Connection in Success
USB LED is always on
3Button
There are two ways of maneuvering buttons in AT288N; Long press & Shot press.
For Short presses, it is recognized and operates when the buttons is released. For Long
presses, it is recognized and operates when the button is pressed for more than 2 seconds.
Pressing buttons usually refers to the short presses unless otherwise specified.
Power Key
Used for turning on/off the device.
When the device is turned off, pressing the power key for a few seconds will
turn on the device.
When the device is turned on, pressing the power key for a few seconds will
turn off the device.

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 11/12
AT288N User guide
AT288N UI guide Page 11
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
C Key
There are two functions for C key. For AT288 users, please note the key functions
differently in AT288N since AT288N only supports 6C.
Short Press
When C Key is pressed, different Inventory Mode can be selected.
One Tag mode-> Multi Tag mode-> Unique Tag mode
Long Press
Long press would enable or disable the Beep Mode.
RF Power Control Left Key
There are two functions for RF Power Control Left Key.
Short Press
RF power can be adjusted. 1dBm is decreased per press. The minimum RF power
that can be set is 11dBm.
Long Press
Remote Protocol can be selected by long press. If COM PORT setting is USB, USB
protocols are selected. If COM PORT setting is BT, BT protocols are selected. It will
take 3.5 seconds to apply the mode changes.
For USB protocol, USB_VCP USB HID USB_VCP
BT Protocol, BT_SPP BT_HID BT_BLE BT_SPP
RF Power Control Right Key
There are two functions for RF Power Control Left Key.
Short Press
RF power can be adjusted. 1dBm is increased per press. The maximum RF power
that can be set is 30dBm.

AXEM Technology
11, rue Auguste Perret - ZAC Europarc - 94042 Créteil Cedex France
Tél. : +33 (0)1 41 94 11 85 - Fax. : +33 (0)1 49 56 91 52 - [email protected] - www.axemtec.com Page 12/12
AT288N User guide
AT288N UI guide Page 12
AT288N UI guide
AT288N UI guide
Corp.
Atid Co., Ltd.
Document
Ui guide
Writer
Won-Tak Choi
Date
2016-05-25
Version
v0.3
Long press (To be supported later)
Run in UHF Update Mode. In this mode, the firmware of UHF Sensor can be updated.
Multi/One Key
No function has been applied yet.
BT/USB Key
Data transmit mode can be selected with BT/USB Key. The selected mode is shown
via BT/USB LED on the device. The mode change (change in LED) is applied two
seconds after the BT/USB Key is pressed. No other modes will be changed during these
two seconds.
Scan Button
Run Inventory. Other buttons do not operate while Scan button is being pressed.
Firmware mode
Firmware mode can be entered by pressing the power key while Scan button is being
pressed. Firmware mode can only when the device is turned off.
4Beep
There are beep sound only when Beep Mode is enabled. The Beep mode is changed by
pressing C Key. If the Beep Mode is disabled, there will be no sounds at all. Beep sound is
operated when Power On/Off, Remote connection/disconnection, Button press and
Inventory is successful.