AXEM Technology MBA5-P23 User manual

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
1/24
MBA5-P23
User guide

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
2/24
Table of content
Background.....................................................................................................................................3
1Product introduction.................................................................................................................4
1.1 Introduction.......................................................................................................................4
1.2 Precaution before using battery........................................................................................5
1.3 Charger.............................................................................................................................5
1.4 Notes................................................................................................................................6
2Installation instructions.............................................................................................................7
2.1 Appearance......................................................................................................................7
2.2 Install Micro SD and SIM cards.........................................................................................7
2.3 Battery Charging...............................................................................................................7
2.4 Buttons and Function Area ...............................................................................................8
3Call function.............................................................................................................................9
3.1 Calling numbers................................................................................................................9
3.2 Contacts ...........................................................................................................................9
3.3 SMS and MMS..................................................................................................................9
4Barcode reader-writer............................................................................................................10
5UHF RFID reader...................................................................................................................12
5.1 UHF Scan function..........................................................................................................12
5.2 UHF configuration...........................................................................................................13
5.3 UHF Tag Reading and Writing........................................................................................14
5.4 UHF Tag Lock and Kill....................................................................................................15
5.4.1 Lock Function..........................................................................................................15
5.4.2 Kill Function.............................................................................................................16
6Other functions ......................................................................................................................17
6.1 Bluetooth ........................................................................................................................17
6.2 GPS................................................................................................................................18
6.3 Volume setup..................................................................................................................19
6.4 Sensor............................................................................................................................20
6.5 Keyboard........................................................................................................................21
6.6 Network ..........................................................................................................................22
6.7 Infrared read-write function (option)................................................................................23
7Accessories ...........................................................................................................................24

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
3/24
Background
Description
Date
Version
Author
Auditor
First parution
29/04/2019
V1.0
CLO
ACA

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
4/24
1Product introduction
1.1 Introduction
The MBA5-P23 has the particularity of integrating UHF RFID technology with a powerful module
and a large antenna allowing blind reading and writing of identifiers up to a distance of 8.5m! In
addition, autonomy is one of its strengths thanks to its 8000 mAh long-lasting battery
With a 5″ FHD touchscreen that offers reading comfort, you can also use the smartphone with wet
hands or gloves. Moreover, it has a 1.3 GHz quadcore processor, a high power that will allow a
fast data processing.
It also has Wireless communication: NFC, 4G/LTE, Wifi, Bluetooth, GPS.
With IP65 protection grade, it is totally protected against dust and is waterproof.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
5/24
1.2 Precaution before using battery
•Do not leave battery unused for long time, no matter it is in device or inventory. If battery has
been used for 6 months already, it should be check for charging function or it should be
disposed correctly.
•The lifespan of Li-ion battery is around 2 to 3 years, it can be circularly charged for 300 to
500 times. (One full battery charge period means completely charged and completely
discharged.)
•When Li-ion battery is not in used, it will continue discharge slowly. Therefore, battery
charging status should be checked frequently and take reference of the related battery
charging information on the manuals.
•Observe and record the information of a new unused and non-fully charged battery. On the
basis of operating time of new battery and compare with a battery that has been used for
long time. According to product configuration and application program, the operating time of
battery would be different.
•Check battery charging status at regular intervals.
•When battery operating time drops below about 80%, charging time will be increased
remarkably.
•If a battery is stored or otherwise unused for an extended period, be sure to follow the storage
instructions in this document. If you do not follow the instructions, and the battery has no
charge remaining when you check it, consider it to be damaged. Do not attempt to recharge
it or to use it. Replace it with a new battery.
•Store the battery at temperatures between 5 °C and 20 °C (41 °F and 68 °F)
1.3 Charger
The charger type is GME10D-050200FGu, output voltage/current is 5V DC/2A. The plug considered
as disconnect device of adapter.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
6/24
1.4 Notes
Note 1:
Using the incorrect type battery has danger of explosion. Please dispose the used battery according
to instructions.
Note 2:
Due to the used enclosure material, the product shall only be connected to a USB Interface of version
2.0 or higher. The connection to so called power USB is prohibited.
Note 3:
The adapter shall be installed near the equipment and shall be easily accessible.
Note 4:
The suitable temperature for the product and accessories is 010℃to 50℃.
Note 5:
CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
7/24
2Installation instructions
2.1 Appearance
2.2 Install Micro SD and SIM cards
The cards sockets are showing as follows:
2.3 Battery Charging
By using USB Type-C contact, the original adaptor should be used for charging the device. Make
sure not to use other adaptors to charge the device.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
8/24
2.4 Buttons and Function Area
Buttons instructions
Side button
1
Power
Located on left side, press to ON/OFF device.
2
Function key
Located on left side, its function can be defined by
software.
3
SCAN button
Scanning button located on both sides. There are
two scanning buttons.
Main button
4
Menu
Display main menu.
5
Home
Touch it back to main screen.
6
Enter
Press to confirm current selection
7
Backspace
Return to last step to setup.
1
2
3
4
5
6
7

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
9/24
3Call function
3.1 Calling numbers
1. Click icon .
2. Click number key to input phone numbers.
3. Click icon to call.
4. Click icon to end call.
3.2 Contacts
1. Click contacts to open contacts list.
2. Click icon to add new contacts.
3. Click icon to import/export contacts.
3.3 SMS and MMS
1. Click to open message window.
2. Click to input message receiver and contents.
3. Click to send out messages.
4. Click to add attachment pictures and videos.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
10/24
4Barcode reader-writer
In App Center, to open 2D barcode scan test.
2. Press “SCAN” button or click scan key to start scanning, the parameter “Auto interval” can be
adjusted.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
11/24
Caution: Please scan codes in correct way otherwise the scanning will be failed.
1D barcode:
2D barcode:
Max. radiant power: 0.6mW
Wave length: 655nm
IEC 60825-1 (Ed.2.0). 21CFR 1040.10 and 1040.11 standard.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
12/24
5UHF RFID reader
5.1 UHF Scan function
1. Open App Center, open “UHF”.
2. Select SINGLE or AUTO and click START, the UHF tags could be read.
3. Click STOP in demo to stop reading of UHF tags.
4. Click CLEAR to clean all EPC information.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
13/24
5.2 UHF configuration
Click CONFIG in demo to adjust working mode and output power.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
14/24
5.3 UHF Tag Reading and Writing
The storage of one tag has 4 zones: RESERVED, EPC, TID and USER. Normally, the default
password is 00000000. And TID zone can only be read, other zones can be read and written.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
15/24
5.4 UHF Tag Lock and Kill
5.4.1 Lock Function
For example. User could try to lock down EPC zone.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
16/24
5.4.2 Kill Function
Kill function can be used to kill the tag permanently. Input the correct access password and click kill.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
17/24
6Other functions
6.1 Bluetooth
1. Open “BT Printer” in App Center.
2. In the list of detected devices, click the device that you want to pair.
3. Select printer and click “Print” to start printing contents.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
18/24
6.2 GPS
1. Click “GPS” in App Center to open GPS test.
2. Setup GPS parameters to access GPS information.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
19/24
6.3 Volume setup
1. Click “Volume” in App Center.
2. Setup volume by requirements.

AXEM Technology
11 rue Auguste Perret, 94042 Créteil, FRANCE –[email protected] –+33 (0)1 41 94 11 85 –www.axemtec.com
Siret : 45071140300045 - APE : 4652Z - RCS : CRETEIL 450711403 - N° TVA intracom : FR05450711403 - Capital : 500 000,00 €
File: MBA5-P23 User Guide
Version : V1.0
20/24
6.4 Sensor
1. Click “Sensor” in App Center.
2. Setup the sensor by requirements.
Table of contents
Other AXEM Technology Barcode Reader manuals