B&PLUS RCS600 User manual

Issue 2022.03.14
No. T318C05Le
L
Thank you very much for purchasing the Wireless charging system RCS600 of B&PLUS.
Please read the instruction manual before use and please use the products correctly.
Wireless charging system
600W specication Manual
RCS600 for 12V,24V,48Vbattery
Standard head, Long distance head
Standard head
Long distance head

For safety precautions
Please read, please use it correctly and full attention to safety this "Safety Precautions" before use.
Incorrect handling may cause not only malfunction or failure, leading to an accident or injury.
Also in order to prevent damage or injury, please look after.
■ About Warnings
You are viewing mark with the following notes on safety in this manual.
It indicates that if ignoring this display, and operate the product in an
improper manner, serious injury or possible death can occur.
If you ignore the display, and operate the product in an improper manner, it
indicates that there is a possibility that people bear the damage, the potential and
property damage may occur.
■ About designation
The symbol shown in the instruction manual and product, have the following meanings.
Shows the attention "Please be careful".
I shows that please without doing the "forbidden".
I indicates mandatory "Please always run".
Attention
Caution
Do not do the resolution and remodeling
Failure to do so may result in re, electric shock or malfunction. In addition, there is a risk that can
lead to serious injury. When I perform the resolution and remodeling, a guarantee may not be received.
Do not use it as trouble and an abnormal state
Smoke, or in the case of such an abnormal state when abnormal noise or oensive smell is,
please stop using it immediately. The Malfunction or electric shock , the cause of the re.
The equipment inside, do not insert foreign objects and water
Such as metal objects or combustible enters, and will be set to smoke or re due to
short circuit or malfunction, re, electrical shock or other damage.
This product is compatible with 12 VDC or 24 VDC or
48 VDC
lead battery and lithium ion bat-
tery.
Because voltage current setting may be required depending on the type of battery
and conditions of use, be sure to contact our sales representative when purchasing.
In accordance with the instructions, please do the wiring and mounting
Please ensure proper procedure to street work. The malfunction or cause of the re.
Caution

Attention
If you want to dispose of this product, you will be disposed of as industrial waste
Please dispose of in accordance with waste disposal regulations specied.
Please be sure to use the specied parts and accessories
The malfunction or accident, the cause of the re.
Please do not take any action in the hot-line state
If you want to support the installation, maintenance, and failure, after conrming that the main circuit breaker
(power board) is always out, please work. When working with hot-state, there is a potential for electric shock.
Please use the power supply as set forth in the specication always
If it is used in power outside of the specications such as a power in excess of the
rated voltage, there is a risk of overheating, re or malfunction.
Keep the specied temperature range
Use the product so that its temperature does not exceed the specied temperature range.
Using outside the specication range may cause equipment failure due to heat generation.
To contact a specialized dealer or installation of equipment (installation), the wiring
Improper by doing installation work on your own, you will malfunction or an electrical
shock, the cause of the re.
Do not put your hands or metal objects between the coils during operation
There and heat generated by induction heating, the potential to catch re.
Do not install in a place that may be exposed to high temperature
When installed in a place such as hot air heater or direct sunlight directly, it could
cause a malfunction or re.
Do not block the cooling fan
Heat build up inside and cause malfunction or re.
Do not touch the high temperature part
Work for a while or immediately after operation, please do not touch the (power sup-
ply unit, charging unit, head part) hot spots. Doing so could result in burns.
Do not use a deteriorated battery
Charging a deteriorated battery may cause the battery to overheat, resulting in an accident or fire.
Replace the battery regularly according to the battery manufacturer’s recommended replacement time.
Do not use head cables other than those specied by us.
If you use a cable other than the specied one, the cable may generate heat, resulting in an
accident, malfunction, or re. Be sure to use the specied cable.
Do not disconnect the battery while charging
If the battery is disconnected during charging, it may cause an accident, malfunction or re.
Be sure to check that the battery is not charged before disconnecting the battery.
Please use indoors
This product is designed for indoor use. Please use it indoors.
The malfunction or accident, the cause of the re.

Request for use on
Disclaimer
● This product, which is one of those high frequency utilization equipment of Radio Law.
In the case of using in Japan, please apply for a permission application for high frequency utilization
equipment permission to Ministry of Internal Aairs and Communications.
In the case of using the product out side Japan, please take appropriate action after conrming by
yourself the standards and regulations to which the customer’s system should conform. If you have
any questions about the application, please contact our sales department.
● For the control communication device that is installed in the product, there is no need for (diplo-
ma) radio station authorization of the Minister as it corresponds to“ a weak radio station (weak radio
equipment)”to.
However, please be careful when operating it as it may aect electronic devices (sensor devices) and
medical devices (pacemakers, etc.).
● In principle, repairs will be charged in the event of failure or damage caused by re, earthquake, acts by
a third party, other accidents, intentional or negligent use by the customer, misuse, or use under abnormal
conditions.
● The Company is not liable for any incidental damages (loss of business prot, etc.) resulting from the
use or inability to use this machine.
● If this unit is used for purposes other than battery charging, we cannot guarantee it.
※ Specications subject to change without notice.
If there is a point of notice about the contents of this document, hope you'll give me your contact us, thank you.
normal open normal close
12V type RCS600-CA12 RCS600B-CA12
24V type RCS600-CA24 RCS600B-CA24
48V type RCS600-CA48 RCS600B-CA48
normal open type: external connection pin (Pin) is arranged as shown on the right. When
the non-voltage contact is ON, charging starts, and when it is OFF, charging stops. To
start charging, it is necessary to turn it on on the ON connector, separate wiring, or on the
control side. Details are described on page 17.
normal close type: the external connection pin (Pin) is arranged as shown on the right.
When the non-voltage contact is OFF, charging starts, and when it is ON, charging stops.
Details are described on page 17.
Pin1.charge start
Pin14.GND
dry contact
internal circuit internal circuit
normal open
Pin1.charge stop
Pin14.GND
dry contact
normal close
● The charging unit of this product have two specications, normal open type and normal close type.
Attention
Do not use under conditions with excessive vibration or impact
Using it beyond the conditions may cause an accident, malfunction or re. Be sure to use it within
the specications.
Do not use in a state where it is lled with dust containing oil and moisture and accumulated.
Accumulation inside the device may cause a malfunction or re. Clean it regularly or put it in a
case to protect it.

■ Index ■
1. Product summary ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6
2. Basic operation
- Various functions and protection ・・・・・・・・・・・・・・・・・・・・ 7
3. The name and specication of each part
- Power Supply unit ・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8
- Active Head(Standard・Long Distance) ・・・・・・・・・・・・・・・・ 9
- Charging unit ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 10
- Passive Head(Standard・Long Distance) ・・・・・・・・・・・・・・・ 11
4. Notes at the time of installation (at the time of attachment) ・・・・・・・・ 12
5. Maintainance ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 14
6. About each unit and LED output display
- Power supply unit display ・・・・・・・・・・・・・・・・・・・・・・・・ 15
- Charging unit display ・・・・・・・・・・・・・・・・・・・・・・・・・・ 16
7. Connection diagram
- Standard Specication Head ・・・・・・・・・・・・・・・・・・・・・・ 18
- Long distance Specication Head ・・・・・・・・・・・・・・・・・・・・ 19
8. Operation method
- How to switch on a power supply ・・・・・・・・・・・・・・・・・・・・ 20
- How to turn o the power ・・・・・・・・・・・・・・・・・・・・・・・・ 20
- About basic charging ・・・・・・・・・・・・・・・・・・・・・・・・・・ 21
- About charge control ・・・・・・・・・・・・・・・・・・・・・・・・・・ 22
- Other ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 24
9. About included product and optional products ・・・・・・・・・・・・・・・・ 25
10. Identifying and troubleshooting abnormalities ・・・・・・・・・・・・・・・・ 28
11. Consultation on how to use and repair ・・・・・・・・・・・・・・・・・・・ 30
Shown in the explanation for12V type
●This manual is for 600W wireless power supply system for 12V or 24V or 48V battery.
The following label is displayed in the explanation of the specic specications.
Please do not confuse the description, and make sure to check the corresponding part.
Shown in the explanation for 24V type
Shown in the explanation for 48V type
RCS600
CA
12
mark is posted as a representative.
RCS600
CA
24
mark is posted as a representative.
RCS600
CA
48
mark is posted as a representative
RCS600B
CA
12
RCS600B
CA
24
RCS600B
CA
48
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
normal open normal close

- 6 -
Wireless charging system 600W specication
For 12V・24V・48V battery
Type code(12V)Type code(24V)Type code(48V)
Description of each part
① Power
Supply unit RCS600-AC
(Common specication)
· Convert AC power to high frequency.
・Receives the input signal and supplies high
frequency to the active head.
· Output various signals received by the active
head to the external control device.
② Active
Head
RCS600-AH
(Common ー for standard specications)
・ By electromagnetic coupling method, power is
transmitted to the passive head without contact.
・Receives various signals from the passive head,
and transmitted to the power supply unit.
RCS600-AH-L
(Common ー for long distance specication)
③ Passive
Head
RCS600-CH
(Common ー for standard specications)
・The receiving power from the active head, and
supplies power to the charging unit.
・Various signals output from the charging unit are
transmitted to the active head wirelessly.
RCS600-CH-L
(Common ー for long distance specication)
④ Charging
unit
RCS600-CA12
*1
RCS600B-CA12
*2
RCS600-CA24
*1
RCS600-CA24
*2
RCS600-CA48
*1
RCS600-CA48
*2
・Charge to a battery is performed.
・Monitor the battery voltage and output the result
to the passive head and the external control
device connected to this unit.
Create a high frequency from an AC power supply, along with the transmitting power in a non-contact with the charge control
circuit, this product is a revolutionary wireless charging system that has at the same time signal communication function.
1.Product Summary
12V type 24V type 48V type
Charging method
(See page 22 for the
detailed charge control)
CC / CV charge control
*1
Charging voltage:Max.15V
Charging current:Max.34A
CP / CV or CC/CV charge control
*1
Charging voltage:Max.35V
Charging current:Max.25A
CP/ CV or CC / CV charge control
*1
Charging voltage:Max.60V
Charging current:Max.12A
Compatible battery 12VDC lead battery
12VDC lithium ion battery
24VDC lead battery
24VDC lithium ion battery
48VDC lead battery
48VDC lithium ion battery
Initial (factory
default) set value
* See page 21 for details.
Charging voltage:14.4V
Charging current:34A
Recharge voltage:12V
Charging voltage:28.8V
Charging current:20A
Recharge voltage:24V
Charging voltage:57.6V
Charging current:10A
Recharge voltage:48V
RCS600
CA
24
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
RCS600
CA
48
Basic product composition
RCS600
CA
12
Various 12V or
24V or 48V
Battery
Various 12V or
24V or 48V
Battery
AC90-220VAC90-220V
④ Charging unit
Type: RCS600(B)-CA24(24V)
Type: RCS600(B)-CA48(48V)
④ Charging unit
Type: RCS600(B)-CA24(24V)
Type: RCS600(B)-CA48(48V)
① Power Supply unit
Type:RCS600-AC
① Power Supply unit
Type:RCS600-AC
② Active Head
Type: RCS600-AH
Type: RCS600-AH-L
② Active Head
Type: RCS600-AH
Type: RCS600-AH-L
③ Passive Head
Type: RCS 600-CH
Type: RCS 600-CH-L
③ Passive Head
Type: RCS 600-CH
Type: RCS 600-CH-L
AGV sideAGV side
Station sideStation side
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
*1 CC/CV:Constant current/ constant voltage
CP/CV: Constant power/ constant voltage
*1 normal open type *2 normal close type
The type code ending in “-NOP” is a model that does not come with a thermistor. The type code of the charging unit (normal
open, normal close) is generally described after this in this manual. “RCS600 (B) -CA__”
System conguration

- 7 -
Wireless charging system 600W specication
For 12V・24V・48V battery
2.Basic operation
● Non-contact power transmission & signal transmission system
Since power transmission and signal transmission are done in a non-contact manner by electromagnetic
coupling method, there is no problem even if glass or plastic exists in the transmission space.
● Oscillation power control function
If you have a transmission area within the specied range within the active head / passive head, active head
will make the oscillation behavior by controlling so that the internal voltage is constant value.If not in the
transmission area is passive head, and it is the specications that make the intermittent oscillation. If the
passive head is in the transmission area, the Ready LED of the power supply unit will light and the Ready
signal will be output to the outside.
●Head overheat protection function
When the internal heat generation of the head exceeds a certain temperature during oscillation of the head,
the protection function is activated and the operation shifts to the intermittent oscillation operation.
● Charging function
The battery is charged by CC / CV charging or CP / CV charging, and it can be almost fully charged. When the
charging voltage exceeds a certain level, it is judged to be fully charged and charging is completed.
● Battery voltage abnormality
12V specication ――Charging is stopped when the battery voltage is other than 8 ± 0.5 to 16 ± 0.5V.
24V specication ――Charging is stopped when the battery voltage is other than 16 ± 0.5 to 31 ± 0.5V.
(If you need to set the charging voltage to 31V or higher, change the internal setting value.)
48V specication ――Charging is stopped when the battery voltage is other than 32 ± 0.5 to 61 ± 0.5V.
● Over current protection
When charging current reaches a certain level or more it stops.
● Over voltage protection
When charging voltage reaches a certain level or more it stops.
● Battery overheating protection
When the battery reaches a certain temperature or below, charging stops.
● Recharge function
If the battery discharges while the heads are facing each other after reaching the set constant voltage and
charging is completed, charging will start again when the recharge voltage falls below the set recharge
voltage. Recharge with the following values.12V specication is 12 ± 0.5V or less, 24V specication is 24
± 0.5V or less, 48V specication is 48 ± 0.5V or less.
● Other functions
〇 Output frequency ・ ・ ・ The frequency to oscillate for non-contact power supply is 85kHz ± 1kHz.
〇 Power supply operation ・ ・ ・ When the main power is turned on, the device goes into a standby state, and when the
power receiving head is located within the rated gap in the power supply head, power supply starts automatically. In
addition, during power supply, the operation adapts to the constant current and constant voltage power supply control
performed by the charge control device on the power receiving side.
When the power receiving head goes out of the power transmission range, it automatically stops supplying power and
goes into a standby state.
〇 Abnormality detection protection function: Detects anomalies, stops charging, and displays an LED on the surface of
the high-frequency power supply.
However, for overheating of the power supply head and overheating of the power receiving head, the signal is stopped,
so the display is the same as in the standby state. The cause of the error display is shown in Power supply unit error
determination.
〇 End of charging ・ ・ ・ Charging ends when the charging current is 1.0A ± 0.5A or less.
RCS600
CA
24
RCS600
CA
48
RCS600
CA
12
Various functions and protection

- 8 -
Wireless charging system 600W specication
For 12V・24V・48V battery
11
100 120 100
8
190
170
80
210
1
(16.5)
(12.5)
350
(6)
Power Supply unit
3.The name and specication of each part
Type code RCS600-AC
Applicable active head RCS600-AH, RCS600-AH-L
Rated input voltage AC100V / AC200V
Supply voltage AC 90V ...AC 220V Single phase 50/60 Hz
Current consumption 9A (at 100V), 4.5A (at 200V)
LED display Power, Ready, Charge, End, Error, E1 ~ E3
External output Power, Ready, Charge, End, Error, E1 ~ E3
Operating temperature 0...50℃
Storage temperature -10...50℃
Operating humidity 35 ... 90% RH or less However, no condensation
Isolation ≧ 50M Ohm
Dielectric strength AC1500V, 1 minute
Shock rating 10 G, in the X, Y, and Z directions 11 ms
Vibration rating 19.6 m / sec 2 (10 to 55 Hz), 20 times in X and Y directions
Protection class IP20 (Indoor installation type)
Weight 3.3kg
Connec-
tion
For power supply Round 3-pin
For communication
Round 5-pin
I/O connector( external
I/O signal)
D-sub25-pin
Power 3P inlet
Cooling method Forced air cooling
Protection circuit Overheat protection
Material Case SECC
Accessories Power cable with 1 ferrite core clamp (gray)
Filters for air intake 8pcs., tapes 8pcs.

- 9 -
Wireless charging system 600W specication
For 12V・24V・48V battery
Standard Specication Active Head
85
125
210
254
4x 7
フェライトコア
E04SR401938
フェライトコア
RFC-H13
46
3000
Long Distance Specication
Active Head
135
150
235
フェライトコア
RFC-H13
250
7
40
(3000)
RCS600-AH-L
Made in japan
Serial No. xxxxxxx
85
125
210
254
4x 7
フェライトコア
E04SR401938
フェライトコア
RFC-H13
46
3000
3P connector
for power supply
5P connector
for communication
Ferrite clamp
Ferrite clamp
3P connector
for power supply
5P connector
for communication
Ferrite core clamp
Standard Specication Active Head
Long Distance Specication Active Head
Type code
RCS600-AH(3.0m),RCS600-AH-005(0.5m)
RCS600-AH-L(3.0m), RCS600-AH-L-005(0.5m)
Applicable unit RCS600-AC
Rated gap Distance 0 ~ 20mm
20 ~ 40mm * Be sure to follow the
specied distance.Using outside the
specications may damage the equipment.
Center oset
± 10 mm in the X axis direction and ± 15 mm
in the Y axis direction (For details, see P. 13)
± 10mm in X axis direction. ± 20mm
in Y axis direction. However, the total
displacement of the XY axes can be
up to 20mm. (See page 13 for details)
Operating temperature 0...50℃
Storage temperature -10...50℃
Operating humidity 35 ... 90% RH or less However, no condensation
Isolation ≧ 50M Ohm
Dielectric strength 2000 VAC / 1min
Shock rating 10 G, in the X, Y, and Z directions 11ms
Vibration rating 19.6 m / sec 2 (10 to 55 Hz), 20 times in X and Y directions
Protection class IP65 (Indoor installation type) IP6X (Indoor installation type)
Weight(including cable connector part)
3.0kg(Cable length3.0m)/2.5kg(Cable length0.5m)
3.3kg(Cable length3m)/2.8kg(Cable length0.5m)
Connection Supply Connected to the Charging unit at the
(male) 3-pin round
Connected to the Charging unit at the
(male) 3-pin round
Communica-
tion
Connected to the Charging unit at the
(male) 5-pin round
Connected to the Charging unit at the
(male) 5-pin round
Material Case PPS, aluminum PPS, aluminum
Output cable
φ 8.6 2.5mm2x3 PUR φ 8.6 2.5mm2x3 PUR
Communication cable
φ 5.6 0.3mm2x4 PUR φ 5.6 0.3mm2x4 PUR
Accessories Central positioning label,2 ferrite
clamps (white, gray)
Central positioning label,1ferrite clamps (white),1
ferrite clamp for power cable (gray)
Max. cable length when us-
ing optional cable
5.5m 5.5m *
Extending the cable of a long-distance
head may cause premature switching of CC ⇒ CV.
Remarks See page 26-27 for cable variations.

- 10 -
Wireless charging system 600W specication
For 12V・24V・48V battery
77
14
7 7
14232
135
80
160
260
16.5
12.5
210 24
1.6
型式:RCS600-CA24
RCS600
CA
24
Setting
Charge voltabe max.
28.8V
Charge current max.
20.0A
Recharge voltabe
24.0V
●充電ユニット
Type code normal open
normal close
RCS600-CA12
RCS600B-CA12
RCS600-CA24
RCS600B-CA24
RCS600-CA48
RCS600B-CA48
Applicable passive head RCS600-CH, RCS600-CH-L
Applicable battery Lithium ion battery, Lead battery
Output voltage Max.15V Max.35V Max.60V
Output current Max.34A Max.25A Max.12A
External input normal open :Charge start signal (activation signal)
normal close: Charge stop signal
External output Ready, Charge, End, Error, E1 ~ E3
LED display Ready, Charge, End, Error, E1 ~ E3
Operating temperature 0...50℃
Storage temperature -10...50℃
Operating humidity 35 ... 90% RH or less However, no condensation
Isolation ≧ 50M Ohm
Dielectric strength AC1500V/1min
Shock rating 10 G, in the X, Y, and Z directions 11 ms
Vibration rating 19.6 m / sec 2 (10 to 55 Hz), 20 times in X and Y directions
protection class IP40(Indoor installation type)
Weight 2.8kg 2.7kg 2.7kg
Connec-
tion
For power supply
Round 3-pin
For communication
Round 5-pin
I/O connector( exter
-
nal I/O signal)
D-sub 25-pin
Battery Battery connection terminal block (terminal screw size M5)
Thermistor
Terminal block for thermistor connection (terminal screw size M4)
Cooling method Natural air cooling
Protection
circuit
Battery Battery high / low temperature protection
Over voltage protection
Over current protection
Material Case Aluminum
Accessories Thermistor(Not included in the -NOP type)
Dsub 25P-Connector for start signal ON (included only to normal open type)
Charging unit
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
※ The printed content of the side
label depends on the model
*normal open and normal close have dierent colors on the front and rear panels.
(normal open: gray normal close: black)

- 11 -
Wireless charging system 600W specication
For 12V・24V・48V battery
84
154
170
26 1500
100
4x 7
フェライトコア
RFC-H13
45
5
Standard Specication Passive Head
3P connector
for power supply
5P connector
for communication
Ferrite core clamp
Long Distance
Specication Passive head
135
150
235
250
4 x 7
( 1500 )
7
40
RCS600-CH-L
RCS600-CH-L
Made in japan
Serial No. xxxxxxx
135
150
235
250
4 x 7
( 1500 )
7
40
RCS600-CH-L
RCS600-CH-L
Made in japan
Serial No. xxxxxxx
3P connector
for power supply
5P connector
for communication
Standard Specication Passive Head
Long Distance Specication Active Head
Type code RCS600-CH(1.5m),RCS600-CH-
01(1.0m),RCS600-CH-005(0.5m)
RCS600-CH-L(1.5m), RCS600-CH-L-01(1.0m)
RCS600-CH-L-005(0.5m)
Applicable unit RCS600(B)-CA24 or RCS600(B)-CA12 or RCS600(B)-CA48
Rated gap Distance 0 ~ 20mm
20 ~ 40mm * Be sure to follow the
specied distance.Using outside the
specications may damage the equipment.
Center oset
± 10 mm in the X axis direction and ± 15 mm
in the Y axis direction (For details, see P. 13)
± 10mm in X axis direction. ± 20mm
in Y axis direction. However, the total
displacement of the XY axes can be
up to 20mm. (See page 13 for details)
Operating temperature 0...50℃
Storage temperature -10...50℃
Operating humidity 35 ... 90% RH or less However, no condensation
Isolation ≧ 50M Ohm
Dielectric strength 2000 VAC / 1min
Shock rating 10 G, in the X, Y, and Z directions 11ms
Vibration rating 19.6 m / sec 2 (10 to 55 Hz), 20 times in X and Y directions
Protection class IP65 (Indoor installation type) IP6X (Indoor installation type)
Weight(including cable connector part)
2.0kg(Cable length1.5m)/1.8kg(Cable length0.5m) 3.1kg(Cable length1.5m)/2.9kg(Cable length0.5m)
Connection Supply Connected to the Charging unit at the
(female) 3-pin round
Connected to the Charging unit at the
(female) 3-pin round
communication
Connected to the Charging unit at the
(female) 5-pin round
Connected to the Charging unit at the
(female) 5-pin round
Material Case PPS, aluminum PPS, aluminum
Output cable
φ 8.6 2.5mm2x3 PUR φ 8.6 2.5mm2x3 PUR
Communication cable
φ 5.6 0.3mm2x4 PUR φ 5.6 0.3mm2x4 PUR
Accessories Central positioning label, 1 ferrite
clamps (white)
Central positioning label, 1 ferrite
clamp for charging cable (gray)
Max. cable length when us-
ing optional cable
5.0m 5.0m *
Extending the cable of a long-distance
head may cause premature switching of CC ⇒ CV.
Remarks See page 26-27 for cable variations.

- 12 -
Wireless charging system 600W specication
For 12V・24V・48V battery
- 18 -
3.各ヘッド取付け注意事項
3-1 周囲金属の影響
周囲金属による影響を避けるため、必ず下記に示す値以上の空間を設けてヘッドを設置する事。
・給電ヘッド/RCS600-AH A=45mm、D=46mm
・受電ヘッド/RCS600-CH B=57.5mm、C=87mm、E=45mm
3-2 相互干渉
ヘッドを取り付ける場合、相互干渉による影響を避けるため、必ず下記に示す値以上の間隔を
あけてヘッドを設置すること。
RCS600-AH,RCS600-CH 共に A=400mm
3-3.ケーブル曲げ R
ケーブルの曲げ Rは下記数値以上にすること。
電力ケーブル:R50、 通信ケーブル:R30
4.Notes at the time of installation (at the time of attachment)
● Notes at the time of installation of the charging unit and power supply unit
・Location
In order to obtain a good cooling eect, please keep as shown below the separation distance between
the surrounding body so as not to block the airow.
● Notes of each head when mounting
・Inuence of surrounding metal
To avoid inuence of surrounding metal, keep minimum spacing.
Also, please remove metal chips and cutting pieces on the transmission surface of the head part. Metal piec-
es may generate heat, which may result in damage to equipment or accidents. Therefore, install it so that the
metal does not face each other for a long time within the range outside the specications.
50mm or more
50mm or more
50mm or more
100mm or more
■ Active Head / RCS600-AH
Power supply unit Charging unit
■ Passive Head / RCS600-CH
A B C D E
Active Head
RCS600-AH
45 46
Passive Head
RCS600-CH
57.5 87 45
(mm)
non-metal non-metal
metal metal
F
F
F
F
G
金属
■給電ヘッド/RCS600-AH-L
■受電ヘッド/RCS600-CH-L
F G
Active Head
RCS600-AH-L
0 40
Passive Head
RCS600-CH-L
(mm)
■
Long Distance Specication Active Head
/ RCS600-AH-L
■
Long Distance Specication Passive Head
/ RCS600-CH-L
metal

- 13 -
Wireless charging system 600W specication
For 12V・24V・48V battery
・For the transmission distance and center o-set between the heads
Set the allowable misalignment of the passive head and the active head within the following ranges.
If the product is used outside the range, you may or equipment degradation of transmission eciency may be
damaged. Also, it is not possible to combine a standard head and a long distance head.
GDirection Distance
G 0 ~ 20mm
X ± 10mm
Y ± 15mm
X 軸方向
Y 軸方向
X 軸方向
Y 軸方向
X 軸方向
Y 軸方向
X direction
Y direction
Direction Distance
G 20 ~ 40mm
X ± 10mm
Y ± 20mm
■
Long Distance Specication Head
* The total axis misalignment
of XY for long distance
specications is up to 20mm.
■
Standard Specication Head
■
Standard Specication Head
Type code A B C D
RCS600-AH 170 45 300 46
RCS600-CH
・Mutual Interference between the heads
If you are installing in parallel head, to avoid the eects of mutual interference, please attach the
head with an interval greater than or equal to the value shown in the table below always.
■
Long Distance Specication Head
Type code E F G H
RCS600-AH-L 190 40 290 40
RCS600-CH-L
(mm)
(mm)

- 14 -
Wireless charging system 600W specication
For 12V・24V・48V battery
R bending of the head and the cable line
Please make the following is greater than or equal to the number of R(mm) bending of the cable line.
・Active Cable and Passive Cable : R50
・Signal Cable line : R30 R
· Installation of ferrite clamp
For details, see P.18 ~ P.20
・Central positioning label
Central positioning label is included for head positioning.
An example of pasting is shown, so please use it if necessary.
【Side view】 【Top view】
Reference example
◆ Filter(Type:RCS600-HJY-00)
This is a filter for the RCS600-AC. Please use it by
attaching it to the air intake section.
A separate instruction manual is available. (No.T320403)
5. Maintenance
<Maintenance>
The cooling fan and power switch may require maintenance depending on the operating environment
and frequency of use. If you notice any abnormality when using the product, please contact us.
Also, to reduce dust/mist, attach the lter included with the power supply unit to the air inlet of the
power supply unit. The filter should be inspected periodically, and if any clogging, deterioration, or
contamination is observed, the lter should be replaced immediately. If the lter becomes dirty, not
enough air can be taken in, which may cause malfunction or re. For replacement lters, see P.25 in the
section "9. Included and Optional Accessories".
Filer
8pcs. included
24pcs. for optional purchases
installation image
Tape
8pcs. included
8pcs. for optional purchases
Tape
Filter
Both sides need to be attachd

- 15 -
Wireless charging system 600W specication
For 12V・24V・48V battery
6.About each unit and LED output display
①
②
③
④
⑥⑦
⑧
⑨
⑤
Power supply unit display (RCS 600-AC)
① Active head
Connect the 3P connector for active head feeding
② Active head
Connect 5P connector for active head communication
③ LED display and error indication
Name Function Display method Output
Power Display main power supply Light in Green Present
Ready
Displayed in the stopped charging state (charging standby state)
Lights in Blue Present
Charge Displaying during constant current or voltage charge operation Light in Orange Present
End Display the end of charging Light in Green Present
Error Indicates abnormality Light in Red Present
Error code Display abnormal contents by combination E1 ~ E3. Light in Red Present
Power supply unit display
For details on how to identify and deal with abnormalities, please refer to “Identifying and Troubleshooting
Abnormalities” on page 28.
④ I/O connector
13 12 11 10 9 8 7 6 5 4 3 2 1
24 23 22 21 20 19 18 17 16 15 1425
GND MD1 GND GND
12VENB TDI TDO
外部接続
E1E2E3
COM
外部接続
※ 図中のスイッチはフォトMOSを示す
GND
5V
RXD2A TXD2AMODE Ready
Error End Charge Power 充電開始
24V
【 NPN 】
■外部接続ピンの配線(4・5・6・7・8・16・17・18)
■電源ユニットの起動信号の配線
※OPEN状態で電源ユニットが動作。
無電圧接点
内
部
回
路
4
Power
20
COM
5
Ready 18
E3
・・・・・
・・・・・
・・・・・
内
部
回
路
1:充電開始
OPEN ・・・・・起動
CLOSE ・・・・停止
14:GND
24V
【 PNP 】
内
部
回
路
Power
4
COM
20
Ready
5E3
18
・・・・・
・・・・・
・・・・・
■充電ユニットの起動信号の配線
内
部
回
路
1:充電開始
14:GND
Unavailable
Unavailable Unavailable
Unavailable
※ The switch in the gure shows the photo MOS
Internal circuit
Internal circuit
■ External connection pin wiring(4.5.6.7.8.16.17.18)
【NPN】 【PNP】
External
connection
External
connection

- 16 -
Wireless charging system 600W specication
For 12V・24V・48V battery
- 10 -
2-4 車上装置
2-4-1 充電コントローラ
(1)ヘッド接続部①②
①.受電ヘッド 電力用 3P コネクタを接続
②.受電ヘッド 通信用 5P コネクタを接続。
(2)表示③
表8の表示及び表 9の異常判別を有する。
表8充電コントローラ 表示
名称 機能 表示手段
出力
備考
Ready 充電開始信号で表示 青色灯火
有り
Charge 定電流または定電圧充電動作中を表示 燈色灯火
有り
End 充電終了を表示 緑色灯火
有り
Error 異常を表示 赤色灯火
有り
Error code E1~E3 の組合せにより異常内容を表示
赤色灯火
無し
表9 充電コントローラ 異常判別
名称 検知内容及び原因 LED 表示
E1
E2
E3
充電コントローラ過熱 充電コントローラ内の過熱検知(約85±5℃) ○
○
電池電圧異常 電池電圧 16-0.5~31+0.5V 以外を検知 ○
出力過電流 電池への過電流を検知 (25±0.5A) ○
電池温度異常 電池の過熱検知(約50±5℃)
○
出力過電圧 電池への過電圧を検知 (33±0.5V) ○
○
通信異常 ヘッドの温度異常、定格ギャップから外れた場合
Name Function Pin No. Remark
Power ON with power supply 4,20 Output
Ready ON when charging is stopped (charging standby state) 5,20 Output
Charge
ON during constant current or constant voltage charge operation
6,20 Output
End ON at the end of charging 7,20 Output
Error ON when abnormal 8,20 Output
E1
E2
E3
The abnormality are indicated by LED lighting combinations of E1 to E3
16,20
17,20
18,20
Output
I/O connector function
Please do not wire with combinations other than those indicated in "I/O connector function" above.
The operation status of the power supply unit is output to the outside simultaneously with the LED indication.
The operation of the output signal turns ON when the LED is lit.
The output circuit is rated voltage 24 V max. current 50 mA, with surge protection only (39 V).
※ The Dsub 25 pin plug side must be prepared separately by the customer.
Soldering type:HDBB-25P (05) Hirose Electric Case made by HDB-CTH Hirose Electric
Terminal block type:SUBCON 25M-SH made by Phoenix Contact
Protective cap:DB-25S-DC1 Hirose Electric
⑤ Mounting section
For housing xing 7 x 15 (M6 bolts: 4 locations for mounting, 4 locations for auxiliary)
⑥ Power
Single phase power supply (90 to 220 V) is connected by AC inlet, this path has over current protection circuit by fuse.
In addition, please set the grounding resistance to 100 Ω or less.
⑦ Power switch
Turn main power ON / OFF.
⑧ Exhaust port
In order to exhaust internal heat by the fan, consider it so that exhaust heat can dissipate to the outside air, please
install 50 mm or more away from the wall.
⑨ inlet
In order to take in the outside air with the fan, consider it so that air can be taken in from the outside air, please set it apart
50 mm or more from the wall.
● Charging side
(RCS600-CA12)
(RCS600-CA24)
(RCS600-CA48)
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
7 7
14
7 7
14232
135
80
160
260
16.5
12.5
210 24
1.6
型式:RCS600-CA24
RCS600
CA
24
Setting
Charge voltabe max.
28.8V
Charge current max.
20.0A
Recharge voltabe
24.0V
※ The printed content of the side label depends on the type code.
Charging unit display(RCS600(B)-CA _)
① Passive head
Connect 3P connector for power supply
② Passive head
Connect 5P connector for communication
③ LED display and error indication
Charging unit indication
Name Function Display method Output
Ready
Displayed in the stopped charging state (charging standby state)
Light in Blue Present
Charge Displaying during constant current or voltage charge operation Light in Orange Present
End Display the end of charging Light in Green Present
Error Indicates abnormality Light in Red Present
Error code Display abnormal contents by combination E1 ~ E3. Light in Red Present
For details on how to identify and deal with abnormalities, please refer to “Identifying and Troubleshooting
Abnormalities” on page 28.
Do not wire to pins other
than those listed in “I/O
Connector Functions”.
It may couse malfunction
if wired to pins other than
listed in the table on the
left.

- 17 -
Wireless charging system 600W specication
For 12V・24V・48V battery
normal open type: When you connect Pin 1 and Pin 14, charging will start.Since the charging
unit does not operate (charge) unless Pin 1 and Pin 14 are connected, use the attached
Dsub25P start signal ON connector, or turn it ON separately by wiring or on the control side.
normal close type: Since Pin 1 and Pin 14 are connected in advance, charging will start
when the power is turned on and the heads are properly facing each other.
【Caution】
④ I / O connector
13 12 11 10 9 8 7 6 5 4 3 2 1
24 23 22 21 20 19 18 17 16 15 1425
GND MD1 GND GND
12VENB TDI TDO
外部接続
E1E2E3
COM
外部接続
※ 図中のスイッチはフォトMOSを示す
GND
5V
RXD2A TXD2AMODE Ready
Error End Charge Power 充電開始
24V
【 NPN 】
■外部接続ピンの配線(4・5・6・7・8・16・17・18)
■電源ユニットの起動信号の配線
※OPEN状態で電源ユニットが動作。
無電圧接点
内
部
回
路
4
Power
20
COM
5
Ready 18
E3
・・・・・
・・・・・
・・・・・
内
部
回
路
1:充電開始
OPEN ・・・・・起動
CLOSE ・・・・停止
14:GND
24V
【 PNP 】
内
部
回
路
Power
4
COM
20
Ready
5E3
18
・・・・・
・・・・・
・・・・・
■充電ユニットの起動信号の配線
内
部
回
路
1:充電開始
14:GND
Unavailable
Unavailable Unavailable
Unavailable
Carge start signal (normal open type)
Carge stop signal (normal close type)
External
connection
※ The switch in the gure shows the photo MOS
Internal circuit
Internal circuit
■ External connection pin wiring(4.5.6.7.8.16.17.18)
【NPN】 【PNP】
■ Wiring of start signal of charging unit
External
connection
※ There is no problem with 12V.
Name Function Pin No. Remark
Charge start signal(activation signal)
dry contact ON: start charging
dry contact OFF: stop charging 1,14 Input
Charge stop signal
dry contact ON: stop charging
dry contact OFF: start charging
Ready Displayed in the stopped charging state (charging standby state) 5,20 Output
Charge ON during constant current or constant voltage charge operation 6,20 Output
End Turn on when charging ends 7,20 Output
Error ON when abnormal 8,20 Output
E1
E2
E3
The abnormality are indicated by LED lighting combinations of E1
to E3
16,20
17,20
18,20
Output
I / O connector function
The operation status of the charging unit is output to the outside simultaneously with the LED indicates
The operation of the output signal turns ON when the LED is lit.
In the output circuit, rated voltage 24 V rated current 50 mA, only surge protection (39 V) is installed.
Parameter setting of charging current · charging voltage · timer is done by connecting dedicated connector
to PC and launching dedicated software
※ The followings are recommended for the Dsub 25 pin plug side if it is prepared by the customer.
HDBB-25P (05) Hirose Electric Machine Case:HDB-CTH Hirose Electric Machine
Case:HDB-CTH Hirose Electric Case
Terminal block type:SUBCON 25M-SH made by Phoenix Contact
⑤ Mounting part
Case xing width 7 mm 4 locations
⑥ Charging output terminal block
A terminal block (M5) that feeds the AGV battery. Charge using the method below. (Numerical values are
factory default)
Charge with constant voltage (14.4 V) and constant current (34 A).
Charge with constant voltage (33.0 V) and constant power (600W) Maximum (25A).
Charge with constant voltage (57.6 V) and constant current (10 A).
⑦ The thermistor connection terminal block
AGV thermistor connection terminal block for battery temperature detection (M4). Please attach the
thermistor. We do not compensate the operation using resistance. When extending, use cables of 0.25
mm 2 or more. If the battery temperature is outside the range of -10 to 60 ° C, battery temperature abnor-
mality is output and charging stops.
⑧ Heat radiation n
In order to dissipate the heat generated during charging from here, please allow 100 mm or more on the
upper side.
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
内部回路
Pin1. 充電開始
Pin14.GND
無電圧接点
A 接点仕様
内部回路
Pin1. 充電停止
Pin14.GND
無電圧接点
B 接点仕様
Internal circuit
Internal circuit
dry contact dry contact
chrage start
normal open normal close
chrage stop

- 18 -
Wireless charging system 600W specication
For 12V・24V・48V battery
BATT
12V
+ -
BATT
12V
+ -
AC 90~220V
受電ヘッド
RCS600-CH
給電ヘッド
RCS600-AH
電源ユニット
RCS600-AC
■充電ユニット
・RCS600-CA24(24V仕様)
・RCS600-CA12(12V仕様)
・RCS600-CA48(48V仕様)
サーミスタ
※バッテリは各仕様による
24V仕様・・・12V x 2(直列)
12V仕様・・・12V x 1
48V仕様・・・12V x 4(直列)
E04SR401938
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
E04SR401938
(フェライトコア)
2T/100mm以内
フェライトコア付き
電源ケーブル
Dsub25P起動信号ON用
コネクタ
RCS600-OP001
- 3 -
図 1 全体構成図(標準仕様)
図 2 全体構成図(長距離仕様)
Ferrite clamp
Within 2T/100mm
※3
Common to standard specication heads and long distance specication heads
· Turn on the power after completing the wiring.
· Battery and charging cable are not included in this product. Please prepare and process by customer.
· Make sure that the ends of the charging cable do not touch each other.
· Please be sure to attach the thermistor to the attached parts. It is recommended to paste on the upper part of battery.
Please do not touch it the terminal
· Connect each cable with the specied length. There is a possibility that an error may occur due to output reduction or the like.
・The "turn", which counts the number of turns of the ferrite clamp of each cable, indicates the number of times that the cable
passes through the inside of the ferrite clamp.
For example, if it is wrapped around the ferrite clamp once, it will take 2 turns, and if it passes through the cable without
wrapping it once, it will take 1 turn.
7.Connection diagram
Standard Specication Head
2T=2 ターン
※ 2 Charging cable is not included.
A cable of 5.5 sq or more is recommended.
Dsub25P 起動信号 ON 用
コネクタ
型式:RCS600-OP001
※2
※1
90 ~ 220V AC
(If you want to use it at AC200V, you need to
process the tip)
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
2T
2T
Charging unit
RCS600(B)-CA12(12V)
RCS600(B)-CA24(24V)
RCS600(B)-CA48(48V)
Battery depends on each specication
12V type…12V × 1 24V type…12V × 2
(series)
48V type…12V × 4
(series)
2 turn
2 turns
2 turn
2 turn
Power cable with ferrite core clamp
(Cable lenth 180cm - Included clamp)
Ferrite core clamp
Within 2T/300mm ※ 3
AYCS-212 BK
Ferrite core clamp
Ferrite clamp
Within 2T/100mm
※3
Within 2T/100mm
Connector for
power supply
Connector for
communication
RFC-H13
E04SR401938
Power Supply unit
RCS600-AC
Active Head
RCS600-AH
Passive Head
RCS600-CH
2T=2 turns
connector for
communication
connector for
power supply
Lead battery
or
Lithium Ion Battery
Thermistor
Type code:
RCS600-OP002
Battery
Dsub25P-Connector for
start signal ON
RCS600-OP001
※ 1 This is a D-sub connector in which PIN1 and PIN14 are
shorted circuit internally. When this connector is attached to
the charging unit, charging starts automatically when the head
is facing. (Required only for normal open type. Not required for
normal close type)
※ 3 Be sure to refer to “Installing the Ferrite Core Clamp” on
the next page.

- 19 -
Wireless charging system 600W specication
For 12V・24V・48V battery
BATT
12V
+ -
BATT
12V
+ -
AC 90~220V
受電ヘッド
RCS600-CH-L
給電ヘッド
RCS600-AH-L
電源ユニット
RCS600-AC
■充電ユニット
・RCS600-CA24(24V仕様)
・RCS600-CA12(12V仕様)
・RCS600-CA48(48V仕様)
サーミスタ
※バッテリ数は各仕様による
24V仕様・・・12V x 2(直列)
12V仕様・・・12V x 1
48V仕様・・・12V x 4(直列)
E04SR401938
(フェライトコア)
1T/100mm以内
E04SR401938
(フェライトコア)
100mm以内
フェライトコア付き
電源ケーブル
Dsub25P起動信号ON用
コネクタ
RCS600-OP001
RFC-H13
(フェライトコア)
2T/100mm以内
3T
2T
- 3 -
図 1 全体構成図(標準仕様)
図 2 全体構成図(長距離仕様)
Long distance Specication Head
※2
※1
※ About installing the Ferrite Clamp
In order to fulll the criteria of Article 65, paragraph 1, product 3 of the Radio Equipment Regulations, and
Ministry of Internal Aairs and Communications Notication 207, and malfunction preventionplease attach
the enclosed ferrite clamp to the following positions with specied turns each.
Case for standard specication head
· 1piece to the communication cable of the passive head within 100 mm from the charging unit. (2 turns)
· 1piece each to the power supply cable and communication cable of the active head within 100 mm from
the power supply unit. (2 turns)
· 1piece to the power supply cable within 300 mm from the power supply unit. (2 turns)(It is already installed
at the time of shipment)
Case for long distance specication heads (see gure above)
・ 1 piece from the charging unit to the battery within 100 mm (1 turn)
・ 1 piece to the communication cable of the active head within 100 mm from the power supply unit (2 turns)
・For the power cable, attach 1 piece of additional ferrite core clamp included with the active head within
300 mm in addition to the one already installed at the time of shipment. (Refer to the gure above ※ 3)
※ When using each extension cables, install them on the unit side regardless of the head specications.
Please refer to the next page.
2T
3T
2T
3T
1T
RCS600
CA
12
RCS600
CA
24
RCS600
CA
48
※3
2 turns
3 turns
90 ~ 220V AC
(If you want to use it at AC200V, you need to
process the tip)
Power cable with ferrite clamp
(Cable lenth 180cm - Included clamp)
AYCS-212 BK
E04SR401938
( フェライトコアクラン
Ferrite core clamp)
3T&2T/within 300mm
1turn
※ 2 Charging cable is not included.
A cable of 5.5 sq or more is recommended.
Battery depends on each specication
12V type…12V × 1 24V type…12V × 2
(series)
48V type…12V × 4
(series)
Lead battery
or
Lithium Ion Battery
Battery
Thermistor Type code:
RCS600-OP002
E04SR401938
Ferrite clamp
Within 1T/300mm
Charging unit
RCS600(B)-CA12(12V)
RCS600(B)-CA24(24V)
RCS600(B)-CA48(48V)
Dsub25P-Connector for
start signal ON
RCS600-OP001
※ 1 This is a D-sub connector in which PIN1 and PIN14 are
shorted circuit internally. When this connector is attached to
the charging unit, charging starts automatically when the head
is facing. (Required only for normal open type. Not required for
normal close type)
2 turns
1T=1 turn
2T=2 turns
3T=3 turns
RFC-H13
Ferrite core clamp
Within 2T/100mm
Connector for power supply
Connector for
communication
Active Head
RCS600-AH-L
Passive Head
RCS600-CH-L
Power Supply unit
RCS600-AC

- 20 -
Wireless charging system 600W specication
For 12V・24V・48V battery
- 3 -
③
RCS600AH-PWN-***
RCS600AH-PWR-*** 給電ヘッド-電源側延長コネクタケーブル
④
- RCS600AH-SIR-*** 給電ヘッド-信号側延長コネクタケーブル
⑤
RFC-H13 分割フェライトコア(白)
⑥
E04SR401938 分割フェライトコア(灰)
図 1 全体構成図(標準仕様)
図 2 全体構成図(長距離仕様)
8. Operation method
How to switch on a power supply
BATT
12V
+ -
BATT
12V
+ -
AC 90~220V
受電ヘッド
RCS600-CH
給電ヘッド
RCS600-AH
電源ユニット
RCS600-AC
■充電ユニット
・RCS600-CA24(24V仕様)
・RCS600-CA12(12V仕様)
・RCS600-CA48(48V仕様)
サーミスタ
※バッテリは各仕様による
24V仕様・・・12V x 2(直列)
12V仕様・・・12V x 1
48V仕様・・・12V x 4(直列)
E04SR401938
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
E04SR401938
(フェライトコア)
2T/100mm以内
フェライトコア付き
電源ケーブル
Dsub25P起動信号ON用
コネクタ
RCS600-OP001
※ For long distance specication head, it is not
necessary to install a ferrite clamp on the charging unit
side.
Ferrite core installation image when using various extension cables with the standard head
Ferrite core installation image when using various extension cables with long distance head
BATT
12V
+ -
BATT
12V
+ -
AC 90~220V
受電ヘッド
RCS600-CH
給電ヘッド
RCS600-AH
電源ユニット
RCS600-AC
■充電ユニット
・RCS600-CA24(24V仕様)
・RCS600-CA12(12V仕様)
・RCS600-CA48(48V仕様)
サーミスタ
※バッテリは各仕様による
24V仕様・・・12V x 2(直列)
12V仕様・・・12V x 1
48V仕様・・・12V x 4(直列)
E04SR401938
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
E04SR401938
(フェライトコア)
2T/100mm以内
フェライトコア付き
電源ケーブル
Dsub25P起動信号ON用
コネクタ
RCS600-OP001
Power Supply unit
RCS600-AC
Charging unit
RCS600(B)-CA _
BATT
12V
+ -
BATT
12V
+ -
AC 90~220V
受電ヘッド
RCS600-CH
給電ヘッド
RCS600-AH
電源ユニット
RCS600-AC
■充電ユニット
・RCS600-CA24(24V仕様)
・RCS600-CA12(12V仕様)
・RCS600-CA48(48V仕様)
サーミスタ
※バッテリは各仕様による
24V仕様・・・12V x 2(直列)
12V仕様・・・12V x 1
48V仕様・・・12V x 4(直列)
E04SR401938
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
RFC-H13
(フェライトコア)
2T/100mm以内
E04SR401938
(フェライトコア)
2T/100mm以内
フェライトコア付き
電源ケーブル
Dsub25P起動信号ON用
コネクタ
RCS600-OP001
Attach the ferrite core clamp
to the unit side
E04SR401938
(
Ferrite clamp
)
Within 2T/100mm
connector for
power supply
connector for
communication
RFC-H13
(
Ferrite core clamp
)
Within 2T/100mm
connector for
power supply
RFC-H13
(
Ferrite clamp
)
Within 2T/100mm
connector for
communication
Passive Head
RCS600-CH
Active Head
RCS600-AH
Attach the ferrite clamp
to the unit side
connector for
power supply
Power Supply unit
RCS600-AC
connector for
communication
RFC-H13
(
Ferrite clamp
)
Within 2T/100mm
Active Head
RCS600-AH
2T=2 turns
Refer to the photo on the previous page
(P.18-20) for the winding image of the
ferrite clamp.
Turn on the power switch on the power supply unit back. (It becomes the "On" when press the white dot side)
・When active and passive heads are out of transmission range:
When the power is turned on, LED of the power supply unit (Power) is lit, it will be intermittent oscillation state.
· When active and passive heads are within transmission range:
When the power is turned on, LED of the power supply unit (Power) is lit.
(However, for normal open type, charging will not start if the charge start signal is OFF.)
Immediately after (Ready) lights up, (Charge) lights and becomes charging state.
How to turn o the power
Turn o the power switch on the power supply unit back. (It becomes the "O" when press the opposite side of
the white dot)
・
When active and passive heads are within transmission range:
When the power is turned o, LED(P) of power supply unit turns o after about 15 seconds, the operation
stopped.
·
When active and passive heads are within transmission range:
When the power is turned o, the LED lamps of
the power supply unit are all turned o and the operation is stopped.
When active head and passive heads are within the range, when the power can be transmitted
charging Immediately.
Attention
Other manuals for RCS600
2
Table of contents
Other B&PLUS Batteries Charger manuals