Power supply
required
115 volts, 60 Hz
Maximum water
temperature
77°F (25°C)
Individual branch
circuit required
15 Amp minimum
Discharge connection 1 in. NPT
Suction connection 1 in. NPT
Water depth rating Maximum of 25 ft.
Discharge Pressure
(PSI)
Gallons per Hour
5 PSI 800
10 PSI 700
17 PSI 600
25 PSI 500
30 PSI 400
40 PSI 200
50 ft. 100
SAFETY INFORMATION
Please read and understand this entire manual
before attempting to assemble, operate or install the
product.
Description
This pump is designed to sprinkle lawns and small
gardens from lakes, ponds, or rivers, empty or fill
stock tanks, remove standing water from flooded
areas, transfer water or boost water pressure.
Flammable liquids such as gasoline, chemicals or
corrosive liquids should never be used with this
pump.
Safety Guidelines
This manual contains information that is very
important to know and understand. This information
is provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help recognize this
information, observe the following symbols.
DANGER - Danger indicates an
imminently hazardous situation which, if not
avoided, will result in death or serious injury.
WARNING - Warning indicates a
potentially hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION - Caution indicates a
potentially hazardous situation, which, if not
avoided, may result in minor or moderate injury.
NOTE: Indicates important information, that if not
followed, may cause damage to equipment.
General Safety Information
1. Read these rules and instructions carefully.
Failure to follow these instructions could cause
serious bodily injury and/or property damage.
DANGER - This pump is non-
submersible.
WARNING - This product contains
chemicals known to the State of California to cause
cancer and birth defects or other reproductive
harm.
SW1011 A

© 2015 All rights reserved. Pg 2
WARNING - Pump only clear water.
Do not pump flammable or explosive fluids such
as gasoline, fuel oil, kerosene, etc. Do not use in a
flammable and/or explosive atmosphere. Personal
injury and/or property damage could result.
NOTE: This pump is not designed to handle
salt water, brine, laundry discharge or any other
application which may contain caustic chemicals
and/or foreign materials. Pump damage could occur
if used in these applications and will void warranty.
WARNING - All wiring must be
performed by a qualified electrician. The pump must
be installed in compliance with all local and national
codes.
2. Connect this product to a grounded circuit
equipped with a ground fault circuit interruptor
(GFCI) device.
3. Before installing this product, have the electrical
circuit checked by an electrician to ensure proper
grounding.
4. BE CERTAIN the pump power source is
disconnected before installing or servicing pump.
5. Be sure the water source and piping are clear of
sand, dirt and scale. Debris will clog pump and
void warranty.
6. Failure to protect pump and piping from freezing
could cause severe damage and will void the
warranty.
7. Do not run pump dry.
Installation
PUMPING FROM LAKES, PONDS OR
SMALL STREAMS
1. Locate pump as close as possible to the water
source, keeping the vertical distance from the
water to pump as small as possible. Place pump
on level support. Protect against flooding and
excessive moisture.
2. Long lengths of pipe or hose and use of many
fittings will reduce pump flow. Use the smallest
number of fittings and shortest possible length of
pipe or hose.
3. Connect inlet pipe or hose to pump. The inlet
connection is designed for 1” NPT thread. Rigid
pipe such as PVC will work fine for inlet and outlet
pipe. (Reminder: Minimize length of pipe and
number of fittings.) An adapter for garden hose is
included (see Figure 1).
IL1857
Pump Inlet
Pump Outlet
Figure 1
NOTE: The inlet hose must be a reinforced type
when pumping from lakes, ponds, or small streams.
Regular garden hose will collapse and lead to pump
failure.
4. A foot valve with strainer should be used to
maintain prime during operation.
5. Seal all connections in the inlet hose. An air leak
in the fittings, hose, pipe or connections will draw
air even though no water leaks out. These inlet
leaks will reduce pump performance and lead to
pump failure.
6. Connect outlet pipe or hose to pump. The outlet
connection is designed for 1” NPT thread. Rigid
pipe such as PVC or garden hose may be used.
An adapter to garden hose thread is included
(Figure 1).
BOOSTING WATER PRESSURE
CAUTION - Never run the pump dry.
Running pump without water will cause seal failure.
Fill pump with water before starting.
1. Remove priming port on pump and fill with water.
Reinstall priming port on pump (see Figure 2). For
boosting water pressure: Do not remove priming
port. Turn on water supply.
IL1858
Priming Port
s
Figure 2
WARNING - Risk of electrical shock!
This pump is supplied with a grounding conductor
and grounding type attachment plug. Use a
grounded receptacle to reduce the risk of fatal
electric shock.

© 2015 All rights reserved. Pg 3
WARNING - Never cut off the round
grounding prong on the power cord. Cutting the
cord or plug will make the pump unsafe to operate
and void the warranty.
2. Turn the pump switch to the “off” position.
3. This pump is only for use on 120 volt (single
phase), 60 Hz, 15 amp service and is equipped
with a 3-conductor cord and e-prong, grounding
type plug. Insert power cord directly into GFCI
outlet (see Figure 3).
IL0459
Figure 3
4. Turn pump switch to the “on” position (see Figure
4). If the pump does not pump water within 5
minutes, turn off pump and refill with clean water.
If the pump does not operate after repeated
attempts, check the following:
- Vertical distance of pump to water level must not
be over 20 feet.
- Suction line must be airtight.
- All valves in suction and discharge line must be
open.
IL1856
On/o
switch
Figure 4
Maintenance
Maintain adequate ventilation for the pump motor.
The motor bearings are permanently lubricated at the
factory. Additional lubrication is not required.
DRAINING FOR WINTER
Always protect pump and piping against freezing
temperatures. If there is any danger of freezing,
drain the system.
1. Disconnect suction and discharge lines from
pump.
2. Remove plug from lower front face of pump.
3. Drain all piping below the frost line, or store piping
indoors.
4. Store pump indoors.
See Figure 5 for replacement parts.
WARRANTY
This product is warranted for one year from the date of
purchase or two years from the date of manufacture, whichever
occurs first. Subject to the conditions hereinafter set forth, the
manufacturer will repair or replace to the original consumer, any
portion of the product which proves defective due to defective
materials or workmanship. To obtain warranty service, contact the
dealer from whom the product was purchased. The manufacturer
retains the sole right and option to determine whether to repair
or replace defective equipment, parts or components. Damage
due to conditions beyond the control of the manufacturer is not
covered by this warranty.
THIS WARRANTY WILL NOT APPLY: (a) To defects or
malfunctions resulting from failure to properly install, operate or
maintain the unit in accordance with printed instructions provided;
(b) to failures resulting from abuse, accident or negligence or use
of inappropriate chemicals or additives in the water; (c) to normal
maintenance services and the parts used in connection with
such service; (d) to units which are not installed in accordance
with normal applicable local codes, ordinances and good trade
practices; and (e) the unit is used for purposes other than for
what it was designed and manufactured.
RETURN OF WARRANTED COMPONENTS: Any item to be
repaired or replaced under this warranty must be returned to the
manufacturer at Kendallville, Indiana or such other place as the
manufacturer may designate, freight prepaid.
THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL
OTHER EXPRESS WARRANTIES, AND MAY NOT BE
EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED
WARRANTIES SHALL BE LIMITED TO THE PERIOD
OF THE LIMITED WARRANTY AND THEREAFTER ALL
SUCH IMPLIED WARRANTIES ARE DISCLAIMED AND
EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER
ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH
AS, BUT NOT LIMITED TO DAMAGE TO, OR LOSS OF,
OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS,
INCONVENIENCE , OR OTHER INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE.
THE LIABILITY OF THE MANUFACTURER SHALL NOT
EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH
LIABILITY IS BASED.
This warranty gives you specific legal rights, and you may have
other rights which vary from state to state. Some states do not
allow limitations on duration of implied warranties or exclusion
of incidental or consequential damages, so the above limitations
may not apply to you.
FOR YOUR WARRANTY PROTECTION, THE WARRANTY
REGISTRATION MUST BE COMPLETED AND RETURNED
TO THE WARRANTY INFORMATION CENTER WITHIN TEN
DAYS OF INSTALLATION. WARRANTY VALID IN CANADA AND
MEXICO.

© 2015 All rights reserved. Pg 4
Troubleshooting Chart
Symptom Possible Cause(s) Corrective Action
Motor will not run 1. Disconnect switch is off
2. Fuse is blown
3. Starting switch is defective
4. Wires at motor are loose,
disconnected or wired incorrectly.
1. Be sure switch is on
2. Replace fuse
3. Replace starting switch
4. Refer to wiring instructions. Check and
tighten all wiring.
Capacitor voltage may be hazardous. To
discharge capacitor, touch short capacitor
terminals with an insulated screwdriver. BE
SURE to hold handle of screwdriver while
making contact with capacitor terminals.
Motor runs hot and
overload kicks off
1. Motor is wired incorrectly
2. Voltage is too low
3. Pump house not properly vented
1. Refer to wiring instructions
2. Check with power company. Install heavier
wiring if wire size is too small (See Wiring
Chart).
3. Be sure pump has sufficient ventilation to cool
the motor
Motor runs but no
water is delivered.
NOTE: Check prime
before looking
for other causes.
Unscrew priming plug
and see if water is in
priming hole.
1. Pump in new installation did not pick
up prime through:
a. Improper priming
b. Air leaks
c. Leaking foot valve
2. Pump has lost prime through:
a. Air leaks
b. Water level below suction of pump
3. Impeller is plugged
4. Check valve or foot valve is stuck in
closed position
5. Pipes are frozen
6. Foot valve and/or strainer are buried in
sand or mud
New Installation:
a. Re-prime according to instructions
b. Check all connections on suction line
c. Replace foot valve
2. Existing Installations:
a. Check all connections on suction line and
shaft seal
b. Lower suction line into water and re-prime.
If receding water level in well exceeds
suction lift, a deep well pump is needed
3. Clean impeller
4. Replace check valve or foot valve
5. Thaw pipes. Bury pipe below frost line. Heat
pit or pump house
6. Raise foot valve and/or strainer above well
bottom
Pump does not
deliver water to full
capacity
1. Water level in well is lower than
estimated
1. A deep well jet pump may be needed (over
25 ft. (7.6M) to water)
2. Steel piping (if used) is corroded or
limed, causing excess friction
2. Replace with plastic pipe where possible,
otherwise with new steel pipe
3. Piping is too small in size 3. Use larger piping
Replacement Parts
P/N Description
024609 Impeller, Diffuser, Nozzle Kit
024610 Pump body
Other Barracuda PUMPS Water Pump manuals
Popular Water Pump manuals by other brands

Balcrank
Balcrank 1120-011 Operation, installation, maintenance and repair guide

Sicce
Sicce Syncra Silent Series instruction manual

Xylem
Xylem JABSCO 50890 instruction manual

Elektro Maschinen
Elektro Maschinen SPE 14500DN operating instructions

Zehnder Pumpen
Zehnder Pumpen Kompaktboy Series Operation manual

Rocker
Rocker 300DC quick start guide