LIMITED WARRANTY AND LIMITATION OF LIABILITY
Barracuda Pumps warrants this product free from material and/or manufacturing defects for
two years from date of purchase. As the sole and exclusive remedy for a breach of this
limited warranty, if the product is found by Barracuda Pumps to be defective, Barracuda
Pumps, at its option, will refund the purchase price or replace the product with an equivalent
product if it is returned to the place of purchase or returned postpaid to Barracuda Pumps,
ATTN: Warranty Dept., 2301 Traffic St. NE, Minneapolis, MN 55413, with proof of purchase.
Any disassembly, modification, or abuse of this product voids this limited warranty. This
product is not designed for pumping flammable or corrosive fluids, and use of this product to
pump such materials also voids this limited warranty
BARRACUDA PUMP DISCLAIMS ALL OTHER
EXPRESS OR IMPLIED WARRANTIES,
INCLUDING WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IMPORTANT NOTICE: Some commercial and residential insurance policies extend coverage
for damages incurred by product failure. In most cases, you will need to have possession of
the product to support your claim. In the case where you need to retain possession of the
product to support a damage claim you submit to your insurance company, Barracuda Pump
will exchange the unit or refund the original price once the claim is settled with the insurer.
2301 Traffic St. NE
Minneapolis, MN 55413
1-800-495-9278
OWNER’S MANUAL
INSTALLATION AND OPERATION
INSTRUCTIONS FOR
SUBMERSIBLE SUMP PUMP
MODEL –92330
Barracuda Sump Manual Revised 4-08

If for any reason you have questions concerning your new Barracuda Pump, call us toll free at
1-800-495-9278.
Carefully read and understand all of the Warnings and installation instructions in this
manual. Failure to follow these instructions could lead to serious bodily injury and/or
property damage. Retain these instructions for future reference.
This pump has been manufactured with your needs in mind. Properly installed in the right
application, your new Barracuda Pump will give you years of carefree performance.
DANGER Water and electricity can be dangerous if certain precautions are not
adhered to. This pump is designed to operate perfectly safe in a water environment; however,
improper use and installation can result in personal harm from electrical shock. Please pay
attention to the following warnings.
WARNING
Never touch any electrical device, including this pump, when it is touching water, in water, or
even in a moist environment. Always unplug (disconnect the electricity) when working on or
installing the unit.
WARNING
RISK OF ELECTRICAL SHOCK. This pump is supplied with a grounding conductor and
grounding-type attachment plug. To reduce the risk of electrical shock, be certain that it is
connected only to a properly grounded, grounding-type receptacle.
WARNING Do not use the power cord or discharge hose to carry or handle the
pump. Doing so may cause damage to the power cord or discharge hose. Use the carrying
handle supplied with the pump.
WARNING Always use a grounded outlet. A three-prong mating type receptacle is
needed for safe use. This should be in accordance with the National Electric Code and any
additional codes or laws required by your local government.
NOTICE It is strongly recommended to use a ground fault interrupt device on any
electrical appliance, including this pump, when used in a wet or moist environment. This is
required by many local codes and enforcement agencies. It is strongly recommended by
Barracuda Pump as it provides a much safer installation and will greatly reduce possible injury
from electrical shock.
REPLACEMENT PARTS
To order replacement parts,
Call 1-800-495-9278
1
4
2
3
5
6
7
8
9
10
Ref #
Description
Part #
1
Power Cord
99008
2
Handle
99050
3
Hose Coupling
99007
4
Oil Fill Plug with O-ring
99055
5
Shaft Seal
99057
6
Impeller
99065
7
Gasket
99062
8
Volute/Base
99069
9
Intake Screen
99073
10
Float Switch with Clamp
92000
2 7

NOTICE Height and/or piping restriction will reduce the pump output performance.
See the performance chart below to insure you have the proper pump for your application.
Whenever possible use the same size or larger pipe as the pump discharge for optimum
performance. Reducing the pipe size will not harm your pump; it will just reduce the output.
PERFORMANCES
Model #
Output in gallons per minute at listed discharge
height above pumping level
0’
5’
10’
15’
20’
25’
92330
40
34
28
22
12
2
SPECIFICATIONS
Power supply requirements 120V, 60 Hz
Motor 1/3 HP, Continuous Duty,
Split Capacitor
Thermally Protected
Amps 4.1
Liquid Temperature Range 32° F - 120° F (0° C - 49° C)
Circuit Requirements 15 amp minimum
Solids Handling 1/8”
Discharge Size 1 ¼” MIP
Warranty 2 Years
DANGER Do not use this pump to pump chemicals, flammable liquids, sewage or
corrosive liquids. You could injure yourself and the pump will fail. Pumping these types of
liquids voids the warranty. Barracuda Pump and other pump companies manufacture pumps
for these types of liquids. Make sure you purchase a pump designed for your specific needs.
This pump will handle fluids with the same characteristics as water. If you have any questions
call us at 1-800-495-9278.
WARNING
Your pump has thermal over-load protection built in. It is not recommended for pumping
liquids over 120F. The thermal overload protector will automatically shut down the pump in
an overheat situation. It will then reset itself once the pump cools down. This overload is
designed as a safety device and it will fail after repeated use. Normal operation is for fluids
between 32F & 120F.
DO NOT RUN THE PUMP DRY. The pump depends on water for cooling and lubrication.
Operating the pump without water may cause the motor to overheat or cause damage to parts
of the pump. It may also shorten the life of your pump.
NOTICE
EXTENSION CORDS
For best performance, it is recommended to connect the power cord directly to the grounded
GFCI outlet. If the use of an extension cord is necessary, always use a grounded waterproof
type cord. Never use longer than a 25-ft. cord that is lighter than 14/3 gauge.
DANGER Keep all electrical connections away from wet and moist environments.
Wet connections can cause electrical shock resulting in personal injury.
USE AND INSTALLATION
WARNING ALWAYS DISCONNECT THE POWER SOURCE BEFORE ATTEMPTING TO
INSTALL,SERVICE OR PERFORM MAINTENANCE ON THE PUMP.FAILURE TO DO SO MAY RESULT IN
FATAL ELECTRICAL SHOCK.
6 3

Your Barracuda Pump is designed and built to give you reliable performance and long life. It
will pump water automatically for years when properly installed in the right environment.
REMOVING OLD PUMP. (If necessary)
1. Make sure power supply is disconnected.
2. After the power is off, remove the old pump. There are many different possible
types of installations.
3. It is best to remove all old piping and start over with new piping. Be sure to clean all
debris and dirt out of the sump basin before installing your new pump.
Be sure to have a grounded 120V AC outlet mounted within 6 ft. of your sump basin. Again, it
is highly recommended that a GFCI (ground fault circuit interrupter) outlet be installed in the
receptacle box.
NOTICE A qualified electrician must perform all wiring.
INSTALLATION (New Pump)
1. Set your new pump in the bottom of the sump basin off to one side. The pump should be
placed on a solid foundation. Do not place the pump directly on the ground or sandy or
rocky surfaces. Sand and small stones may clog or cause damage to your pump.
2. Make sure the float switch will swing freely from the bottom to top without coming in
contact with the side of the sump basin. Contact with the side of the sump basin may
cause the switch to malfunction. See figure below.
3. It is highly recommended to install a full flow, swing type check valve (not included)
as close to the discharge outlet on the pump as possible. A new check valve will
greatly increase the life of your pump. The check valve should be the same size as
the pump discharge.
4. Connect the pump and check valve together using schedule 40 PVC pipe and
fittings. You can also use DWV or ABS pipe, as this is not a pressure installation.
Corrugated drain hose is intended for temporary use and should not be used in a
permanent installation. Although there are many types of pipe that work adequately
for this installation, PVC is recommended.
5. Test your installation after you have completed setting up the pump. Plug the cord
from the pump into the piggyback plug of the float switch, then plug that into your
grounded outlet. The pump should not run at this point. If the pump runs, the
switch is stuck in the upright position or the pump is plugged directly into the outlet
and not through the piggyback switch plug. Fill the sump basin with water using
buckets or a hose. When the switch floats to the upright position, the pump will turn
on. The switch will turn off the pump when it reaches the down position. You may
adjust the switch to meet your particular needs. Remember the switch must swing
freely without touching the sides of the sump basin.
NOTE: This pump has a built in anti-airlock device. Leakage is normal from this device.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES
HOW TO CORRECT
If the pump does not
start or run
Pump is not plugged in, switch or breaker is off
Plug pump in or turn on switch/breaker
Check for blown fuses or tripped circuit breakers or
tripped GFCI outlets
Replace fuse, reset breaker, reset GFCI
outlet
Float switch is defective
Check and replace if necessary
Motor thermal protector tripped
Allow pump to cool. Pump will reset
Float switch is stuck or obstructed
Remove obstruction or position pump so it
will not become stuck
The pump starts and
stops too often
Backflow of water from discharge hose/pipe
Install or replace check valve
Float switch is defective
Replace float switch
If the pump runs but
moves little or no water
Clogged intake screen
Clean or replace screen
Clogged discharge hose/pipe
Remove clog
Frozen discharge hose/pipe
Allow hose/pipe to thaw
Pump is air locked
Clean out airlock hole with a paper clip or
pipe cleaner
Low line voltage
Check wire size and increase if necessary
Check valve is stuck in the closed position
Inspect, repair or replace if necessary
Check valve is installed backwards
Make sure valve is installed in the correct
direction of flow
Worn, damaged or clogged pump parts
Inspect for wear, damage or clog and clean
or replace if necessary
Discharge head exceeds pump capacity
If pumping height is over 25’, the pump will
not move water. See performance chart
Pump does not
shut off
Float switch is obstructed or stuck
Remove obstruction
Defective Float Switch
Replace switch
4 5
A. Grounded Outlet. A GFCI outlet
is strongly recommended.
B. Discharge Pipe
C. Full-flow swing type check valve
D. Position pump so the float switch
operates freely without touching
the sides of the basin.
Other Barracuda Water Pump manuals
Popular Water Pump manuals by other brands

Simer
Simer OD6601G Series owner's manual

Pentair
Pentair JUNG PUMPEN MULTICUT 08/2 ME/1 instruction manual

pumpa
pumpa BLUE LINE PSP Series Translation of the original instruction manual

GORMAN-RUPP PUMPS
GORMAN-RUPP PUMPS RP4D60 Installation, operation, and maintenance manual with parts list

Graco
Graco Monark instruction manual

ProMinent
ProMinent 10022 Supplementary operating instructions