BARRON HN035-01VR User manual

2 3 4 5 623456
Ceiling Mounted
1
3
2
4
5
Mounting
height
Wall Mounted
1 2 3 4 5 876
1
2
3
1
2
3
CoveredWell covered
Mounting
height
Detection area
≤0.5W
5.8GHz±75MHz
<0.3mW
Operating current
Output
ON/OFF 1-10V
Stand-by power
Hold time
Daylight threshold
Microwave frequency
Microwave power
Mounting height
Detection range
84*18*11 mm
Detection angle
<30mA
Operating voltage
10.5-15V DC (supply current >50mA)
Size
360°(ceiling mounted),150°(Wall Mounted)
Operating temperature
-40°C~+80°C
Warranty
5 years
Disable/50Lux
50% /100%
30s/1min/2min/5min
Technical data
Detection coverage
Typical installation height 2.5-4.5m Mechanical structure
This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.
Daylight
threshold
Hold
time
Detection
area
On/off
control
5
years
Remote
control
Max.4.5m (ceiling mounted)
ø4-8m (ceiling mounted)
Stand-by dimming level
Stand-by period
Stand-by dimming level (7)
Mode selection (8)
Stand-by period (5,6)
10%/30%
0s/1min/5min//+∞
Daylight threshold
IR Receiver Antenna module
(1)
Detection area
Red: VCC
Black: GND
White: DIM +
Black: DIM -
(2,3)
Hold time
(4)
Daylight threshold
20070184 REV 1 P1 800-533-3948 www.barronltg.com
-1- -2-
HN035-01VR
DC Input Remote Control

Wiring diagram
Dimensions (Unit: mm)
LED Driver
HN035-01VR
L
N
L
N
LED+
LED-
VCC+
GND
DIM+
VCC+
GND
DIM+
DIM-DIM-
Settings
In this area, movement will be detected and able to trigger the sensor. 100% detection
area is also known as the strong sensitvity.
The period of light keeping 100% brightness after moving objects leave the detection
area.
Definition of the ambient brightness; only when the ambient brightness is lower than
the preset specific lux amount, the sensor will work; when it's preset as "disable", the
sensor works everytime it
detects motion regardless the ambient brightness.
Detection area
Detection area
Hold-time
Hold-time
Daylight threshold
Daylight threshold
The period of light keeping low output before it's completely switched off. When it's
preset as"∞“, the light always keep at low output if no movement in the detection area
and doesn't turn off.
Sensor mode on when the DIP switch is up; sensor mode off when the DIP switch is
down.
Stand-by period
Stand-by period
Mode selection
Stand-by dimming level
Mode selection
Stand-by dimming level
The definition of low output in the standby period.
Switch UP
Switch DOWN
100%
50%
Disable
50lux
10%
30%
ON
OFF
30s
1min
2min
5min
0s
5min
1min
+∞
Red: VCC+
Black: GND
Yellow: DIM +
white: DIM -
18
84
11
20070184 REV 1 800-533-3948 www.barronltg.com
-3- -4-

With insufficient
daylight, when motion
detected, light ON.
With sufficient
daylight, even when
motion detected, light
remains OFF.
After the stand-by
period, light OFF.
After last detection,
the light will be
dimmed down to the
stand-by dimming
level (10%,30%) after
holdtime.
Hold time Stand-by period
3. Function Demo - Dimmable control/Corridor function
Hold time
After the last detection and
the present hold time
elapsed, light OFF.
With sufficient daylight,
even when motion detected,
light remains OFF.
With insufficient daylight,
when motion detected, light
ON.
After people leave the detection
area, light remains 100%
brightness within hold time.
When motion is detected,
the sensor will switch on the
light to 100% brighteness.
After the last detection and
the present hold time
elapsed, light OFF.
2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period 0s/10s/30s/1min/
5min/10min/30min.
Applications: Dim places such as Basement Parking, Underpass.
1. Automatically ON/OFF function:
The Stand-by period is set to "0s".
Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
Application Attention
1. Please read the instructions carefully before using this product and keep it well
for all users to read at any time.
2. The sensor should be installed by qualified electrician and ensure power is off
before the installation.
3. We reserve the right to modify any incorrect text, image and necessary technical
parameters.
4. Any unauthorized modification is forbidden, otherwise all guarantees will be
immediately invalid.
1. Microwave sensor can be installed in any lamp except the one with full metal shell.
2. The detected surface cannot be shielded by metal objects.
3. Make sure the microwave module is completely exposed outside.
4. The detection surface of the sensor module shall be installed facing the detection area.
5. Should be kept away from the driver to avoid interference generation and lamp flashing.
6. Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
Installation precautions
1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or
tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as
galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false
triggering caused by machine vibration.
Application Environment
1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2. The driver voltage shall be stable and float within 10%.
3. Detection area will be affected by speed of motion, mounting height and movement volume.
4. Conduct test on sunny days without the lampshade which will affect the tested lux value
User Notes