Barton 99911 Original instruction manual

14000BTU MOBILE AIR CONDITIONER
SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY,
OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S
SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH
AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).
OWNER’S MANUAL AND SAFETY INSTRUCTIONS
ITEM: 99911
FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT: (909) 628 0880 MON-FRI 9AM TO 3PM PST

1
All wiring must comply with local and national electrical codes and be installed by a qualied
electrician. If you have any questions regarding to the following instructions, contact a qualied
electrician.
The unit must be installed in accordance with national wiring regulations. Check available power
supply and resolve any wiring problems before installation and operation of this unit.
For your safety and protection, this unit is grounded through the power cord plug when plugging
into a matching wall outlet. If you are not sure whether the wall outlet in your home are properly
grounded, please consult an electrician. If supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied person in order to avoid any hazards.
This appliance is not intended for people(including children(with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety. Young children
should be supervised to ensure that they do not play with the appliance.
GENERAL SAFETY WARNINGS
Read all safety warnings and instructions. Failure to follow the warnings and instructions may
result in electric shock, re and/or serious injury. Save all warnings and instructions for future
reference.
SAFETY
The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible
conditions and situations that may occur. It must be understood by the operator that common sense and
caution are factors which cannot be built into this product, but must be supplied by the operator. Read
carefully and understand all instructions before operating. Failure to follow the safety rules and other
basic safety precautions may result in serious personal injury.
To reduce the risk of re, electrical shock or injury when using your air conditioner,
follow these basic precautions:
DO NOT use this unit in wet environment, like outdoor or bathroom etc., use is for indoor use only.
DO NOT remove grounding prong.
DO NOT use an adapter.
DO NOT use an extension power cord.
NEVER share the power outlet with other appliances.
NEVER connect or disconnect the power plug with wet hands, to avoid electric shock.
NEVER turn off the unit by unplugging.
Unplug air conditioner before servicing.
NEVER dismantle, repair or modify the unit without authorization to avoid body injury or property
damage, be sure it repaired by manufacturer or professionals.
NEVER put any objects into the unit.
NEVER cover or obstruct air inlet or outlet to prevent overheating.
IMPORTANT SAFETY INFORMATION

2
NEVER hit or shake the unit to prevent damage.
NEVER spray water or place the unit near water to prevent electric shock.
NEVER place the unit near gas appliances, re or ammable liquids.
Two or more people to move or install air conditioner.
DO NOT let children play near the unit.
Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference.
DO NOT expose the unit under direct sun light to avoid surface color fading.
DO NOT tilt the unit for more than 35 degrees or upside-down while transporting.
Place the unit on a at surface and upright with less than 5 degrees inclination.
Keep the drain hose in good condition without exure then connect with unit.
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made
by children without supervision.
The unit operates more efciently in certain room locations (see Installation and Adjustment).
Empty the condensed drainage pan before putting the unit in storage to prolong the unit lifetime end of
the season.
DO NOT use chemical solvents (e.g. Benzene, alcohol-glazer) to clean the unit surface, do not scratch
or damage the unit.
Make sure to cut off the power before disassembling or installing the lter.
DO NOT use this unit in cooling mode if the ambient temperature is higher than 35°C or heating mode
if ambient temperature is lower than 7 °C.
IMPORTANT SAFETY INFORMATION
SAVE THESE SAFETY WARNINGS.

3
Eco-friendly CFC free, lead free and high energy efciency portable air conditioner, you can stay cool while
keeping with better environmental standards and reducing energy consumption. Cools or heats up to a 500
sq. ft. space (ambient temperature and humidity may inuence optimum performance); 14,000 BTU cooling
capacity and 13,000 BTU heating capacity (outside temp must be above 41F); Casters for easy mobility;
Activated carbon air lter removes odor and smoke and a washable pre-lter; Remote control lets you
easily adjust the temperature and function mode; Patented auto drain function fully exhausts all condensate
automatically in most environments; Auto Restart - Auto-restart saves your settings for when power is
restored to the unit; Dehumidication Function - Control your indoor humidity level with our innovative
dehumidication function. It mixes cool dry air, with the warm air to keep you comfortable and prevent
overcooling.
FEATURES
Certication:ETL and UL Listed. Operating Modes Available:Heater/Air conditioner.
Cooling Capacity:14,000 BTU
Air condition:Yes. Heater Mode:Yes.
Fan Speeds:3
Adjustable Temperature:62F - 82F
Power:120VAC 60Hz
Timer Setting:Up to 24 hours
Dehumidify:Yes. Auto Clean:Yes.
Refrigerant/Charge:R410A/20.45oz. Air Flow:430m3/h 253 cfm.
Max Noise Level:56dB(A)
RemoteControl:Yes. Window Venting Kit:Yes.
Overall Dimension:14”(L) x 18-1/2”(W) x 33-1/2”(H)
PRODUCT FEATURES

4
Certication:ETL and UL Listed. Operating Modes Available:Heater/Air conditioner.
Cooling Capacity:14,000 BTU
Air condition:Yes. Heater Mode:Yes.
Fan Speeds:3
Adjustable Temperature:62F - 82F
Power:120VAC 60Hz
Timer Setting:Up to 24 hours
Dehumidify:Yes. Auto Clean:Yes.
Refrigerant/Charge:R410A/20.45oz. Air Flow:430m3/h 253 cfm.
Max Noise Level:56dB(A)
RemoteControl:Yes. Window Venting Kit:Yes.
Overall Dimension:14”(L) x 18-1/2”(W) x 33-1/2”(H)
DIAGRAM

5
CONTROL PANEL OPERATION
1. ENERGIZE THE UNIT : Plug in the unit and all icons on the LCD display window will light up for 2 seconds.
Then the LCD display window will show an ambient temperature with a range of 5 - 35°C (41-95°F). The unit
is on standby for operation.
2. POWER : This button is to turn on the unit, once pushed the music alert will sound. The unit runs
under cooling mode automatically with a set temperature of 22°C (72°F) and the fan will run at medium
speed. Touching this key again, will power off the unit and the music alert will sound. When unit is on the
LCD display window will show ambient temperature, the fan will start running and the air outlet window will
open automatically. When the unit is off, all parts stop will stop running and the air outlet window will close
automatically.
3. MODE : Touch this button is to switch and select the unit working mode
OPERATION

6
1. UP and DOWN : Depressing the UP or DOWN buttons once to increase/decrease the
temperature 1°C or 1°F. Touching the UP or DOWN button for over 2 seconds will continuously increase/
decrease the temperature by 0.5 second intervals. Temperature setting range is 16~30°C/60-80°F.
Depressing the UP or DOWN buttons at the same time will convert celsius degrees to farenheit degrees.
Depressing the UP or DOWN buttons in TIMER status to adjust the time setting.
SPEED: Depress this button to change the fan’s running speed from high, medium to low speeds.
COOL AND FAN MODES: Fan running speeds can be adjusted by the following order below.
HEAT: upper fan will run at low speed after the compressor works 2 minutes.
DEHUMIDIFY: At this mode, the fan will be forced to run at low speed and the temperature cannot be
adjusted. The fan speed will be unchanged if the unit is operated between COOL and FAN modes. This
means if the fan is running at low speed under FAN mode, the fan speed will stay the same when the unit
is changed to COOL mode; if fan running at high speed under COOL mode, it would keep same when unit
changed to FAN mode.
TIMER: Depress this key to set the units auto turn-on /turn-off time, to check or cancel time setting.
This unit is designed with 24-hour timer rst two digits are for hours 00-24, and last two digits
are for minutes 00-60. You can increase or decrease by half an hour each time by touching UP and
DOWN to nish hour and minute setting.
You can set the unit’s AUTO OFF time when it is running. Or set the unit’s AUTO ON time when unit is on
standby. Touching the TIMER button again to reset the time when the timer function is on. The TIMER is
subject to the nal time setting.
TIMER + UP : Turn on or off Auto-Swing by depressing SPEED and UP. The horizontal louvers will
swing automatically when the unit starts working. Depressing SPEED and UP at the same time to turn off.
Auto-Swing in the LCD screen will be off. Retouch SPEED and UP together to turn Auto-Swing back
on.
ENERGY SAVING: The background light on the LCD screen will light up for 10 seconds when you touch any
key when the unit is powered on.
AUTO-CLEAN: Depress this key to set the units auto turn-on /turn-off time, to check or cancel time
setting.
ENERGY CONSERVATION: Low energy consumption under Energy Conversation mode.
OPERATION

BEFORE USING YOUR AIR CONDITIONER, INSERT BATTERIES INTO YOUR REMOTE CONTROL
1. POWER: Press this button to start the unit when it is energized
or stop the unit when it is in operation.
2. MODE: Press this button to select operation mode.
3. TEMPERATURE : Press this button to increase/decrease room
temperature and timer setting.
4. FAN: Press this button to select fan speed in sequence: Low → Medium
→ High.
5. AUTO-SWING: Press this button to turn on or turn off auto-swing
function.
6. SLEEP: Press this button to select or cancel sleep mode (only effective
under cooling, heating operation or energy conversation modes).
7. TIMER: Press this button to set AUTO-ON and AUTO-OFF time. Time
can be adjusted between 0.5-24 hours. It jumps by 0.5 hour interval within
5 hours, and 1 hour interval over 5 hours, set time will ash 5 times on
screen then conrm the setting.
Before using your remote, install the AAA batteries into remote control.
Use alkaline batteries only. Do not use rechargeable batteries.
When replace batteries, always replace both batteries with new batteries, do
not mix old and new batteries.
If the air conditioner will not be used for an extended period of time, remove
the batteries from the remote control.
NOTE: In order to avoid losing the remote control, please put the remote control inside of the storage place.
Your air conditioner has a special place for convenient storage
the remote control
7
FEATURES AND PARTS

8
Keep this mobile air-conditioner in upright position at least 2 hours before rst installation.
This air-conditioner may be moved indoor conveniently; keep the unit in upright position while moving
it. The air-conditioner shall be placed at at surface.
DO NOT install or operate this air-conditioner in bathroom or other wet environments.
INSTALLATION
Installation of exhaust hose assembly and its adapter.
1. Take out the exhaust hose and its connector and adapter, to remove the plastic bag.
2. Extend one end of exhaust hose, screw the end without slot of round connector onto it with anticlockwise
direction at least 3 laps.
3. Extend another end of exhaust hose, screw the adapter onto it with anticlockwise direction at least 3
laps.
NOTE: Screw round connector and adapter into right position, at least 3 laps, to keep good connection of
exhaust hose assembly.
INSTALLATION OF EXHAUST HOSE ASSEMBLY TO MAIN UNIT
INSTALLATION

1. Put front end of exhaust hose assembly onto jugged position of exhaust air outlet at back panel, fasteners
will lock the exhaust hose assembly. See illustration.
2. Keep the right direction of slant side of adapter, for ease installation of window seal-plate. Make sure to
keep the exhaust hose connected in good position.
3. Make the window half open, put the seal-plate into window, either in vertical or horizontal position. See
illustration.
4. Extend seal plate parts and adjust it to the length of window, keep both ends to meet window edge, x it
with screws.
5. Keep two ends of window seal-plate to meet the window edges well, to assure seal effect. Tighten screws.
6. Move the unit with the exhaust hose assembly installed in front of window and keep the unit at least 50cm
away from the walls or other objects.
7. Install the rectangle end of exhaust hose assembly into the corresponding rectangle hole in window seal-
plate assembly, x it with screw and close the window.
9
INSTALLATION

8. Slide the adapter downwards and assure adapter installed in good position.
9. Assure the slant panel direction to match seal-plate direction.
10. The exhaust hose cannot be bent or with exure higher than 45°, in order to keep good ventilation of
exhaust hose
NOTE: The exhaust hose is 280mm-1500mm long and this length is determined based on the specication
of the air-conditioner (s). Do not use prolonged the hose or replace it with other different hoses as this may
affect the functions of the air-conditioner. The exhaust hose must be smooth or it may lead air-conditioner
overheat and damage.
DRAINAGE
MANUAL DRAINAGE:
Once the unit shuts down upon water-full, turn off the unit and then unplug.
Put the tray below the water outlet at the back of the unit.
Screw off the drain cover, unplug the water stopper for water ow into the tray.
Plug in stopper and screw the drain cover tightly onto water outlet after drainage.
NOTE:
Protect the drain cover and water stopper properly.
Move the unit carefully to avoid the leakage it is necessary.
Tilt the unit slightly backwards when draining.
Block the drain hole as soon as possible before the tray is full if it cannot hold all water in the unit to
prevent the water leakage and wet the oor or carpet.
Water stopper and drain cover must be tightly installed, to avoid new condensate to wet the oor or
carpet when the unit re-starts working.
CONTINUOUS DRAINAGE:
Screw off the drain-cover & unplug the water stopper.
Connect drain-hole with φ12mm drain hose, as deep as possible to avoid leakage.
Pull the drain hose to bathroom or outdoor.
NOTE:
Drain hose must be installed when there’s no water in the tray.
It is suggested that not to use continuous drainage when unit is in COOL mode, to ensure enough water
recycle in the unit to enhance the system cooling effects.
It is suggested that to adopt continuous drainage when unit is in HEAT mode, to avoid frequent drainage.
Put the drain hose in an inaccessible place, not higher than drainage hole and keep drain hose straight
without any exure.
Keep the drain cover and its stopper properly when continuous drainage is adopted.
10
INSTALLATION

MULTIPLE PROTECTION FUNCTIONS:
1. Under COOL mode, when the compressor continuously runs over 10 minutes, if tube temperature is
<=2°C/36°F for 20 seconds, the anti-frozen protection function will be on, E4 will be shown on LCD display,
compressor and water wheel motor will stop working, but upper fan remains running; If tube
temperature>=8°C/46°F, the unit will stop anti-frozen protection and recover to the original working
condition. Compressor will re-start working with 3 minutes delay for protection.
2. Water-full safety alarm and shut –off protection function: When the water volume exceeds its alarm
level in chassis, warning sounds automatically and water-full icon is lighting in LCD display, you need to
drain the condensate and re-start the unit.(For more information about how to drain, refer to the “Drainage
Instruction” please). If the unit is not shut down manually, the unit will recover to the original operating
status automatically once the water is fully drained. Or connect the power to re-start the unit again.
3. Auto-Defrosting Protection: The system of this unit is with Auto Defrosting function, and will light up
until Auto Defrosting is nished, start the unit again.
4. Auto-Overheat Protection: This unit is with auto overheat function under heating mode. Compressor
and lower fan will stop working if unit with higher temperature, and recovery if unit temperature down to
normal to prolong unit working life.
5. Delay Protection Function of Compressor: This unit offers restart protection to compressor. Except
that the compressor may start immediately when the unit is energized rst time, there is 3-minute delay
re-start protection after compressor is shut down.
MAINTENANCE AND SERVICE
NOTE: Be sure to turn off the unit and pull out the plug before maintain or send to service center.
SURFACE CLEANING:
Clean the unit surface with wet soft cloth and do not use chemical solvents such as alcohol and gasoline
to avoid any damage to unit.
Clean the dirty air outlet or louvers with wet soft cloth and detergent.
Any chemical solvent is prohibited to use for unit cleaning or put such things near the unit for a long
time.
Any thinner, alcohol-glazer or other similar solvents is prohibited for unit cleaning.
11
MAINTENANCE

12
FILTER CLEANING:
Grip the lter handle and pull it out gently in correct direction.
Clean the dirty particles in lter by cleaner if it is necessary.
Immerse and wash the lter gently into warm water (about 40() mixed with neutral cleaner, and then
rinse and dry them thoroughly in the shade.
NOTE: Clean the lter once every two weeks, or it would inuence the unit function if lter clogged with dust.
Pull out the lter gently.
Removal of lter at back panel is at priority then for the lter at side panel, to avoid any twist or damage
to lter.
Do not squash or hit the mesh with sharp objects.
MAINTENANCE

INSTALLATION OF THE FILTER:
Be sure to install the lter to side panel then for the lter to back panel.
Install the lter with opposite direction of removal.
Install the lter into place gently to avoid any damage to lter.
END OF SEASON STORAGE:
1. Screw off the drain cover and pull out the stopper to drain condensate water completely. (Note: the tilt
angle of the unit must be <=30).
2. Keep the unit running in fan mode for half day to dry inside of unit completely to prevent from going
moldy.
3. Turn off the unit, pull out plug then wrap the power cord around the wire-winding pillar, insert the plug into
the universal xing hole at the back panel of the unit, install the water stopper and drain cover.
4. Remove the heat exhaust hose assembly, clean and keep it properly. Hold the exhaust hose assembly
with both hands when removal. Push the fasteners aside on exhaust air outlet using your thumbs, then pull
out exhaust hose assembly.
5. Pack the air-conditioner properly with soft plastic bag and put it in dry place with appropriate dust-proof
measures, and keep the unit away from children.
6. Take out the batteries from the remote control and keep it properly. Ensure the unit is stored in a dry
place. All accessories of the unit shall be protected together properly.
SPECIFICATIONS
13
FUSE PARAMETER
TYPE: FSD or 50F
VOLTAGE: 250V
CURRENT: 3.15A
MAINTENANCE

14
Please check the unit and suggestions below before asking for professional service, but never dismantle
or repair the unit by yourself, it may cause harm to you and your property.
Correct Disposal of this product This
marking indicates that the product
should not be disposed with other
household wastes. To prevent
possible harm to the environment
or human health from uncontrolled waste
disposal, recycle it responsibly to promote
the sustainable reuse of material resources.
To return your used device, please use the
return and collection systems or contact the
retailer where the product was purchased.
They can take this product for environmental
safe recycling.
Schematic diagram
TROUBLESHOOTING

15
PARTS LIST

THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY
DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR
DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT
HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS
QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER AND/OR
DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE
UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS, AND NOT BY THE BUYER. THE BUYER
ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL
PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION
OF REPLACEMENT PARTS THERETO.
Record Product’s Serial Number Here:
Note: If product has no serial number, record month and year of purchase instead.
Note: Some parts are listed and shown for illustration purposes only and are not available individually
as replacement parts.
PLEASE READ THE FOLLOWING CAREFULLY
16
PRODUCT MADE IN CHINA
WARRANTY
Table of contents
Other Barton Air Conditioner manuals
Popular Air Conditioner manuals by other brands

PR KLIMA
PR KLIMA GPC10AL operating instructions

Daikin
Daikin VRV III REMQ8P8Y1B installation manual

Trane
Trane Packaged TerminalAir Conditioners & Heat... Installation operation & maintenance

Heiko
Heiko JZ026-B1 installation manual

CLIMAVENETA
CLIMAVENETA i-ACCURATE i-AX Installation manual - user and maintenance

Daikin
Daikin ERLQ004CAV3 installation manual

Hitachi
Hitachi RAS-70YHA1 instruction manual

Toshiba
Toshiba RAS-10J2KV-HK owner's manual

Unitary products group
Unitary products group Sunline 2000 DM180 installation manual

Panasonic
Panasonic S-22MF2E5A8 Service Manual & Test Run Service Manual

Haier
Haier AU96NFTAHA Service manual

Kolin
Kolin KLG-SF40-5G1M owner's manual