Basalte Lisa User manual

Quick Reference Guide
Lisa
© 2021
basalte v1.0
F
E
C
A
B
D D
A
B
C
D
E
F
Proximity & light sensor
Reset button
USB
Microphones
Speaker
LAN+Power over Ethernet
Lisa is designed to be wall mounted.
Lisa requires a minimum mounting depth of 24mm from
the back side of Lisa plus room for cable/s. Power is
supplied by Power Over Ethernet (PoE). PoE must meet the
IEEE 802.3af standard. Lisa connects to the local network
via a hard wired Ethernet connection.
The recommended mounting height for Lisa is
1450 mm -1650 mm (57”- 65”) above the finished floor.
1Installing Lisa
a. Mounting height
1450 mm / 57”
1650 mm / 65”
b. Rough-In
EU/CH single-gang box
UK single-gang steel boxUK standard single-gang box
EU/CH single-gang box
c. Mounting
EU/CH single-gang junction box:
Take off the 2
original screws
of the gang box
before mounting!
d. Installing the mounting bracket
Take off the 2
original screws
of the gang box
before mounting!
UK standard single-gang:
e. Connecting Lisa to power and Ethernet
PoE Injector
PoE Network Switch
Network Switch
To Lisa
f. Installing Lisa on the wall
Push
Top of
single-gang Box
Mounting Bracket
Dry Wall LockedDry Wall
Top of
single-gang Box
Mounting Bracket
g. Mounting Lisa
Align the mounting bracket hooks with the mounting
slots and gently press Lisa towards the mounting
bracket/wall.
Make sure the mounting hooks are properly engaged.
Lisa has been designed to mount to a EU/CH single-gang
junction box, UK standard single-gang junction box or
steel box.
The mounting bracket, included in the box, should be
attached with included screws (2x #5-24).
Install the single-gang box junction box in its
normal orientation.
Using the included #5-24 screws to mount the mounting
bracket onto the EU/CH single-gang junction box, UK
standard single-gang junction box or steel box.
PoE Connection
PoE connection requires the IEEE 802.3af standard.
Use a network switch or PoE injector that meets this
standard.
Connect Lisa using a standard T568A or T568B Ethernet
cable from the network switch to the LAN/PoE connector
on the back of Lisa.
Position Lisa for mounting, align the mounting bracket
hooks with Lisa mounting slots and gently press it
towards the mounting bracket/wall.
Lisa snaps in when pushed to its mounting bracket.
CAUTION: DO NOT PRESS DIRECTLY ON THE SCREEN
When installing on to the mounting bracket. Press only
on the frame edges.
2x #5-24
UK single-gang box
D

Designed in USA
Assembled in Belgium
Lisa will automatically power on when power is
applied. Wait for the unit to boot up completely.
When connected to a switch by Ethernet cable Lisa
will acquire a network address via DHCP and
automatically connect to the system.
2Powering up Lisa 3Removing Lisa
4Reset button
Follow the step 1 and 2 in order to remove Lisa
from the wall.
Push
Top of
single-gang Box
Dry Wall
Pull
If you want to restart Lisa, shortly press the recessed
reset button (upper button on the le side).
Aer +/- 10" the Basalte logo will appear and
Lisa will restart.
Reset button
(Recessed)
Important Safety Instructions
1. Read, understand and follow ALL safety and installation instructions
included in this manual. Failure to follow the included documentation
may damage the product and will void manufacturer’s warranty.
2. Follow ALL installation guidelines included with the product. Installation
of the product in high humidity environments, in close proximity to heat
sources and/or non-recommended locations WILL impede, interfere
and/or damage the intended operation of the product.
3. Only use attachments and accessories which have been specified for use
by the manufacturer.
4. The use of abrasive, liquid or solvent based cleaning fluids WILL damage
the product.
5. Product Servicing may ONLY be completed by authorized or certified
service centers & personnel. For a complete list of product servicing
options, please follow instructions included in the product documentation
and/or contact the basalte support for details.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver.
- Connect the equipment into an outlet on a circuit dierent
from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician
for help.
FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE
STATEMENT:
basalte is a registered trademark of basalte bv.
basalte bv
hundelgemsesteenweg 1a I 9820 merelbeke I belgium
Thank you for using Lisa as part of your intelligent home.
Lisa has been designed to provide years
of trouble free operation when wired and installed
properly.
Lisa has been designed for installation in low
humidity indoor environments and should never be
installed outdoors or in high humidity areas.
Included in the box
•1x Lisa touch panel
•1x mounting bracket
•2x #5-24 Mounting Screws
lisa
Proximity sensor
Reset button
(Recessed)