1.0 Warnings
3
1.1 Safe Installation
1. The appliance is suitable only for installation in
GB and IE and should be installed in accordance
with the rules in force.
In GB, the installation must be carried out by a
CORGI Registered Installer. It must be carried out
in accordance with the relevant requirements of
the GAS SAFETY (Installation and Use)
REGULATIONS. The appropriate BUILDING
REGULATIONS either the Building Regulations, The
Building Regulations (Scotland), Building
Regulations (Northern Ireland). The WATER
FITTINGS REGULATIONS OR WATER BYELAWS in
Scotland. The current I.E.E. WIRING REGULATIONS.
Where no specific instructions are given, reference
should be made to the relevant BRITISH
STANDARD CODES OF PRACTICE. Reference
should also be made to BRITISH GAS GUIDANCE
NOTES FOR THE INSTALLATION OFDOMESTIC GAS
CONDENSING BOILERS.
In IE, the installation must be carried out by a
competent person and installed in accordance with
the current edition of I.S.813 “DOMESTIC GAS
INSTALLATIONS”, the current BUILDING REGULATIONS
and reference should also be made to the current
ETCI rules for electrical installation.
2. This appliance must be installed in accordance
with the manufacturer’s instructions and the rules
in force, and only used in a suitably ventilated
location.
3. Read the instructions before installing or using
this appliance.
4. Any purpose provided ventilation should be
checked periodically to ensure that it is free from
obstruction.
IMPORTANT - The addition of anything that
may interfere with the normal operation of the
appliance without express written permission
from the manufacturer or his agent could
invalidate the appliance warranty.
In GB this could also infringe the GAS SAFETY
(Installation and Use) REGULATIONS.
1.2 In case of gas leaks
1. If a gas leak is found or suspected, turn off the
gas supply at the meter immediately and call your gas
supplier. Do not operate any electrical equipment
or light switches.
1.3 Servicing your Appliance
For reasons of safety and economy your appliance
should be serviced annually. Your Installer will be
able to advise you.
WARNING: The condensate outlet must not be
blocked or modified.
1.4 Electricity Supply
1. THIS APPLIANCE MUST BE EARTHED.
2. A standard 230V ~ 50Hzsupply is required. The
appliance must be protected by a 3 amp fuse.
STANDARD
B.S. 6891
B.S. 5440: Pt 1
B.S. 5440: Pt 2
B.S. 5546
B.S. 7074
B.S. 5449: Pt 1
B.S. 6798
B.S. 5793
SCOPE
Gas Installation.
Flues.
Air Supply.
Installation of hot water supplies
for domestic purposes.
Expansion vessels and ancillary
equipment for sealed water systems.
Forced circulation hot water systems.
Installation of gas fired hot water
boilers.
Treatment of water in domestic hot
water central heating systems.
IN AN EMERGENCY
If a water or gas leak occurs or is suspected, the boiler can be
isolated at the inlet valves as follows;
1. Turn off the electrical supply.
2. The isolating valves are positioned under the boiler and can be
closed using either a flat headed screwdriver or a 7mm open
ended spanner across the flats.
3. Turn the gas tap clockwise to the stop position to isolate the
gas supply at the boiler.
4. To isolate the water system, close the four valves fully by
turning clockwise.
5. Call your Service Engineer as soon as possible.
“Benchmark”Installation, Commissioning and Service
Record Log Book
Please ensure that your installer has completed the Installation
and Commissioning sections of the Log Book and hands the Log
Book over. The details of the Log Book will be required in the event
of any warranty work. Keep the Log Book in a safe place and
ensure that the relevant sections are completed at each
subsequent regular service visit.
All CORGI registered installers carry a CORGI identification card
and have a registration number. Both should be recorded in your
boiler Log Book. You can check your installer is registered by
telephoning +44 (0)1256 372300 or writing to:-
CORGI. 1 Elmwood, Chineham Business Park, Crockford Lane,
Basingstoke. RG24 8WG.
Never Hang Any Items Over The Appliance
In GB the following Codes of Practice apply:
STANDARD
I.S. 813
B.S. 5546
B.S. 7074
B.S. 5449
B.S. 7593
SCOPE
Domestic Gas Installations.
Installation of hot water supplies
for domestic purposes.
Expansion vessels and ancillary
equipment for sealed water systems.
Forced circulation hot water systems.
Treatment of water in domestic hot
water central heating systems.
In IE:
The following BS standards give valuable additional information