manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. BBC Bircher
  6. •
  7. Microphone System
  8. •
  9. BBC Bircher AirMission 1 User manual

BBC Bircher AirMission 1 User manual

1
56
95
73
Ø 3
31
45
70.5
10
Ø 4.5
175
189
50.8
138
10.8
4.8
36
AirMission 1
Before commencing the installation or assembly complete the following
safety precautions:
• Check the voltage data on the label of the switching device.
• Ensure that the device/installations can not be switched on!
• Determine that the power supply is disconnected!
• Protect the device with a housing against contamination or aggressive
environments!
• Connect all operating and switching voltages to the same fuse.
• Connect the operating voltage to the same circuit as the industrial door
controller.
• Disconnect device from mains in the event of a fault.
Limited protection against accidental contact!
It is recommended to change the batteries every year.
Wireless signal transmission system with integrated pressure wave switch
Translation of the original operating instruction
General
1Safety instructions
2Common application
2.1 Industrial door
ENGLISH
350483D
10/19
Transmitter
Pressure wave safety edge
Receiver
System for monitoring pressure wave system safety edges.
ReceiverTransmitter
i
• Read these operating instructions thoroughly before putting the device
into operation and keep them for future reference.
• The assembly, commissioning, modications and extensions may only
be completed by an experienced electrician!
• Before commencing work, remove the power supply from the device/
installations!
• During the operation of electrical components
– e. g. in the case of a short circuit hot and ionised gases can be
– emitted
– protection covers must not to be removed!
• Pay attention to all local relevant electrical safety regulations!
• Disregard of the safety regulations can cause death, severe injuries or
extensive damage!
• Devices that are classied as Category 2 according to EN ISO 13849-1
must be tested regularly – at least once per cycle.
• It is the responsibility of the equipment manufacturer to carry out a risk
assessment and to install both the detector and the equipment in
compliance with applicable national and international regulations and
safety standards, as well as the Machinery Directive 2006/42/EC,
should this apply.
2
OK?
➔
➔➔
➔
3
2x
➔
➔
➔
1 2 3 4
ON
ON
Klick
C B S
VCC1
VCC2
COM
OUT
SOUT
TEST
TEST
+/~ –/~
12/24V
AC/DC Test
C B S
VCC1
VCC2
COM
OUT
SOUT
TEST
TEST
+/~ –/~
12/24V
AC/DC
Test

open
collector
C B S
8K2
C B S
8K2
3.3 DIP switches
1 2 3 4
ON *Safety application
Standard
according to EN ISO 13849-1
1 2 3 4
ON Inactive ➔no safety function!
(Radio connection is not monitored)
12 3 4
ON Transmission frequency
869.85 MHz:
Set DIP-switch before pairing
transmitter – receiver
12 3 4
ON * 868.95 MHz:
Set DIP-switch before pairing
transmitter – receiver
12 34
ON Test input type
NC
activated = contact open
12 34
ON * NO
activated = contact closed
12 3 4
ON Automatic frequency adjustment
Active
Used only in case of severe radio disturbance
12 3 4
ON * Inactive
*= factory setting
3.1 Wiring: Power supply and test inputs
Relay contacts are shown unpowered
3.2 Wiring: Outputs and control
3Receiver
11.
Connect safety edge with
transmitter (rubber hose)
4Installation
9.
Install
transmitter
10.
Close
6.
Insert both
batteries
(front/back)
4.
Transmitter:
Open
5.
Carefully pull out
PCB
8.
Slide PCB back into
housing
12.
System test:
Activate safety edge,
see 6.1
1.
Receiver:
Check DIP switch settings
3.
Receiver:
Turn on power
supply
2.
Install and wire
receiver
7.
Programming (Chapter 5.1):
Pair transmitter with receiver
Click
3x
Gate control
with
NC input
Gate control
8.2 kOhm
input
Status Terminals
C – B
Terminals
C – S
Sensor not activated (operating mode) 8K2 closed
Sensor activated (security system activated) closed open
No supply voltage closed open
Transmitter and receiver not paired closed open
Transmitter batteries low closed open
3
2x 2x
i
1 2 3 4
ON
2x
2x
1234
ON
SELECT
REL21
1 2
4x
OK?
➔
➔
Klick
The distance between the transmitter
and receiver and additional transmitters
must be at least 1 m
5.1. Pair the transmitter with the receiver
5Programming
1.
On the receiver
Press button Beep LED lights upRelease button
2.
On the trans-
mitter
On the receiver
Press and
release button
Wait 2 beeps Code saved
LED goes out
10 sec.
Beep Beep
> 1.5 sec.
> 1.5 sec.
Beep
Press button Hold down button Short beepsBeep WaitRelease button 2x beeps
5.2 Transmitter reset (clear pairing between transmitters and receiver)
On the receiver Memory cleared
on all trans-
mitters
5.3 Memory full
10 sec.
Beep
Beep
> 1.5 sec. > 3 sec.
10 sec.
Beep Beep Beep
Beep
Beep
6Operation
6.1 Receiver LED indicators 6.2 Warning indicator for low battery voltage
Object
detected
LED off
LED
Safety
OK
Battery
low
Signal sounds each time a transmitter is activated
Beep
LED on
7Battery replacement
5.
Close
1.
Open
3.
Replace both
batteries
(front/back)
2.
Carefully pull out
PCB
4.
Slide PCB back into
housing
6.
System test:
Activate the safety edge
see 6.1
Click
4
8Technical data
Receiver
Supply voltage 12/24 V ACDC
Transmitter memory 10
Output 1 relay 24 V, 0.5 A; micro disconnection 1B
Power consumption 0.5 W @ 12 V; 1.2 W @ 24 V
Test signal input 12/24 VACDC
Protection class IEC 60529 IP55
System
Frequency bands 868.95 MHz & 869.85 MHz
Range Under optimum conditions up to 100 m
Response time 25 ms
Pollution degree 2
Working temperature -20 °C to +55 °C
Transmitter
Battery power 2 x Lithium 3 V Type CR2032
Power consumption Transmitting: 17 mA, standby: 16 µA
Protection class
IEC 60529
IP54
9Standards EN ISO 13856-2 and EN ISO 13849-1
The AirMission 1 system itself is not able to check the function of the
sensor in response to a pressure pulse. In accordance with D 3.5 of
EN ISO 13856-2, a pressure wave system according to category 2 of
EN ISO 13849-1 can be designed by checking the pressure wave system
at every machine cycle. On the doors and gates the door/gate control
must assure this function in order to satisfy category 2. (➔ Figure A.4 of
EN ISO 13856-2).
Designed in Switzerland / Made in EU
BBC Bircher Smart Access, BBC Bircher AG, Wiesengasse 20, CH-8222 Beringen, www.bircher.com
10 EU Declaration of Conformity
12 Contact
See attachment
11 WEEE
Devices with this symbol must be treated separately during disposal. This must be done in accordance with the laws of the
respective countries for environmentally sound disposal, processing and recycling of electrical and electronic equipment.

Other BBC Bircher Microphone System manuals

BBC Bircher XRF-R1 User manual

BBC Bircher

BBC Bircher XRF-R1 User manual

BBC Bircher RFGate 2.2.W2.F.A Quick guide

BBC Bircher

BBC Bircher RFGate 2.2.W2.F.A Quick guide

BBC Bircher RFGate 2.2.S Wiring diagram

BBC Bircher

BBC Bircher RFGate 2.2.S Wiring diagram

Popular Microphone System manuals by other brands

ADC FlexWaveTM MMW 100 Specification sheet

ADC

ADC FlexWaveTM MMW 100 Specification sheet

PASGAO PAW-850 user guide

PASGAO

PASGAO PAW-850 user guide

Trantec S5 Quick installation guide

Trantec

Trantec S5 Quick installation guide

Micmas MS-9603 product manual

Micmas

Micmas MS-9603 product manual

Sound Town SWM26-U2 Series product manual

Sound Town

Sound Town SWM26-U2 Series product manual

Azden 105UPR user guide

Azden

Azden 105UPR user guide

LD 737 630 instruction sheet

LD

LD 737 630 instruction sheet

SABINE TRUE MOBILITY WIRELESS SYSTEM SWM3000 operating guide

SABINE

SABINE TRUE MOBILITY WIRELESS SYSTEM SWM3000 operating guide

Schoeps DSP-4 KFM 360 operating instructions

Schoeps

Schoeps DSP-4 KFM 360 operating instructions

Beyerdynamic TG 1000 operating instructions

Beyerdynamic

Beyerdynamic TG 1000 operating instructions

Radio Shack 32-1221B owner's manual

Radio Shack

Radio Shack 32-1221B owner's manual

TouchTunes 600157-001 Product information

TouchTunes

TouchTunes 600157-001 Product information

Ikegami BS-98 Operation manual

Ikegami

Ikegami BS-98 Operation manual

Shure BLX4R user manual

Shure

Shure BLX4R user manual

Audio Technica ATW-D70 Installation and operation

Audio Technica

Audio Technica ATW-D70 Installation and operation

Monacor JTS UR-816DSET/1 instruction manual

Monacor

Monacor JTS UR-816DSET/1 instruction manual

Audio Technica ATW-DA600 Installation and operation

Audio Technica

Audio Technica ATW-DA600 Installation and operation

Shure Microflex MXW manual

Shure

Shure Microflex MXW manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.