Beam Platinum Series User manual

EN
DOC-703-INTBM REV01
USER MANUAL
Central Vacuum System

2 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
TABLE OF CONTENT
INTRODUCTION ...................................................................3
IMPORTANT SAFEGUARDS..........................................................4
GROUNDING INSTRUCTIONS - WARNING .............................................5
INSTALLATION ....................................................................6
HOW TO USE......................................................................7
LCD INSTRUCTION .................................................................8
MAINTENANCE ....................................................................12
TROUBLESHOOTING ...............................................................13
SERVICE INFORMATION ........................................................... 14

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 3
Congratulations on your purchase of a new BEAM Central Vacuum System. It is the built-in cleaning
appliance designed to help you clean your home eciently and eectively. Unlike conventional vacuums
that can recirculate dust, a BEAM system lifts dirt, dust mites, pollen, dander and other allergens from
floors, curtains, furniture and other surfaces, and carries them away from living areas to help improve
indoor air quality. It has been clinically proven to relieve allergy symptoms.
To obtain the maximum benefit from your BEAM System, please read this manual carefully prior to use.
Then enjoy cleaner, healthier living and years of trouble-free performance.
For more information on BEAM Central Vacuum Systems and other innovative BEAM products,
visit beamvac.com
Components of a BEAM Central Vacuum System
Power Unit/Dust Collection Receptacle: Mounted in the utility room, basement or garage, it removes dust,
dirt and allergens from living areas.
Tubing: Dust and dirt are carried through tubing from “inlet valves” to the power unit/receptacle.
Inlet valves: Installed in the wall, each inlet valve connects the power brush and flexible cleaning hose
to the tubing in your home.
Cleaning tools: Flexible hose and tools make whole house cleaning easy.
INTRODUCTION
1. Central Vacuum Pipe installation
2. Wall Inlet
3. Power Unit
4. Filtered Separator
5. External Exhaust

4 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
When using an electronic appliance, basic precautions should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING THIS VACUUM SYSTEM.
To reduce the risk of fire, electric shock or injury:
• Do not use outdoors or on wet surfaces.
• Do not block the motor hood or ventilation openings and duct on the top of the power unit.
Lack of ventilation airflow will cause the motor to overheat.
• Do not locate the power unit in a high temperature area or where it is inaccessible, for example, an attic
or crawl space.
• Mount the power unit no less than 30cm from the ceiling or any adjacent wall and at least 70 cm from
the floor. Additionally, review any local codes and regulations that may apply.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
• Unplug before cleaning or servicing the central vacuum.
• Use only as described in this manual. Use only manufacturer’s recommended attachments.
• Do not use with damaged cord or plug. If vacuum cleaner is not working as it should, has been dropped,
damaged, left outdoors or dropped in water, return it to a service center.
• Connect to a properly grounded outlet only (refer to grounding instructions).
• Do not use extension cords or outlets with inadequate current carrying capacity.
• Turn o all controls before unplugging.
• Do not unplug by pulling on the cord. To unplug, grasp the plug, not the cord.
• Do not handle plug or cord with wet hands.
• Do not put any object into openings. Do not use with any openings blocked; keep free of dust, lint, hair
and anything that may reduce airflow.
• This vacuum cleaner creates suction. Keep hair, loose clothing, fingers and all parts of body away from
openings and moving parts.
• Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
• Use extra care when cleaning on stairs.
• Do not pick up flammable or combustible liquids such as gasoline, or use in areas where they may be
present.
• Keep your work area well lighted.
• Unplug electrical appliances before vacuuming them.
• If the supplied power cord is damaged, it must be replaced by a special cord available from
the authorized local dealer/distributor.
• Do not use without dust bag and/or filter in place.
SAVE THESE INSTRUCTIONS
IMPORTANT SAFEGUARDS
Waste of Electrical and Electronic Equipment (WEEE) The symbol on the product or on its packaging indicates that this product
may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of
electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this
product. For more detailed information about recycling of this product, please contact your local waste disposal service or the
shop where you purchased the product.

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 5
GENERAL INFORMATION
The central vacuum system is designed for dry pick up of household dirt and dust. Avoid picking up hard
or sharp objects with the system to prevent hose and plastic pipe damage or clogs. This central vacuum
system is intended for Household Use.
Power unit
Your power unit is equipped with a 230/240-volt motor and employs an overload protection device,
which can be reset should the motor be overloaded causing the circuit to open. It is normal for some dirt
and lint to cling to the filter. However, the filter should be checked occasionally to be sure it has not been
punctured or torn. The dirt receptacle should be emptied 2-3 times a year on the average depending on
the amount of use. For best results, empty the canister when it is about half full. Any dirt spilled can be
vacuumed up quickly by plugging the hose into the nearest inlet valve. The on/o button on the power
unit will start and stop the power unit. No part of the unit requires lubrication.
Service Information
The instructions in this booklet serve as a guide to routine maintenance. For additional information,
contact your nearest authorized dealer/distributor.
DO NOT OIL THE MOTOR AT ANY TIME. IT IS PERMANENTLY LUBRICATED AND SEALED.
Rating Plate
The model, type and serial numbers are indicated on the rating plate located on the control panel
or motor hood. For prompt and complete service information, always refer to these numbers when
inquiring about service.
GROUNDING INSTRUCTIONS - WARNING
WARNING
This appliance must be grounded, if it should malfunction
or breakdown, grounding provides a path of least resistance
for the electric current to reduce the risk of electric shock.
This appliance is equipped with a cord having an
equipment grounding conductor and ground plug.
The plug must be inserted into an appropriate outlet that
is properly installed and grounded in accordance with all
local codes and ordinances.
WARNING: Improper connection of the equipment -
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or service person if you are
in doubt as to whether the outlet is properly grounded. Do not
modify the plug provided with the appliance – if it will not fit
the outlet; have a proper outlet installed by a qualified electrician.
WARNING: If the supply cord is damaged, it must be replaced by a special cord available from your
local authorized dealer/distributor.
Plug Types
G epyTE epyT Type H Type I Nema 6-15 R
Grounded
Outlet
Grounding
Pin
Grounded Pin
Bucket

6 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
Planning
If your home already has the system of plastic pipes and inlet valves, you are ready to install the power
unit (refer to Install Power Unit section below). If not, you can contract to have the system installed by
a professional or you may choose to do-it-yourself. If you plan to install the system yourself, it is
important to carefully plan the location of each inlet valve, the power unit, and the network of plastic
pipes. This booklet only deals with the installation of the power unit; “How-To” booklets are generally
included with installation kits. Careful planning will help you determine the installation kits to buy.
The kits should contain enough plastic pipe and fittings,
and inlet valves for your needs. Check with your local
dealer/distributor if you have any questions.
Power Unit Location
NOTE: Mount power unit at least 30 cm from the ceiling
and any adjacent wall, at least 70 cm from the floor and
within 1.8m of an electrical outlet. Review any local
regulations that may apply.
The power unit should be located as far away from the
general living are as possible, yet accessible so you can
remove the dirt receptacle, reach the filter, and inspect the
power unit. A typical location would be in a garage where
you could vacuum your car or garage area and where
emptying the dirt receptacle and cleaning the filter would
be more convenient. Other suitable locations are in the
basement, laundry room, or ventilation storage room.
Install Power Unit
You are now ready to install the power unit. Be sure the
power unit will be located at least 30 cm from the ceiling
and any adjacent walls and at least 70 cm from the floor.
The motor hood ventilation should never be obstructed.
Check to be sure you will be able to occasionally remove the dirt receptacle, reach the filter, and inspect
the power unit. In the chosen mounting location, compare the distance between the wall studs and the
power unit mounting brackets. If the mounting bracket cannot mount on one of the wall studs, mount
the two boards horizontally between the studs and then attach the mounting bracket to these. Once the
bracket is on the wall, you can now hang the power unit. With the unit on the wall, align the power unit
intake fitting with the main pipe projecting from the wall and connect these together. DO NOT GLUE.
WARNING
Do not block the hood ventilation openings on the top of the power unit. Lack of ventilation will
cause the motor to overheat.
Do not locate the power unit in a high temperature area where it is inaccessible for example,
an attic or crawl space.
Figure 1
INSTALLATION

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 7
HOW TO USE
Locate the two low-voltage wires near the main pipe. Remove
the insulation from the low-volt wire. Insert the low-volt wire
into the spring-loaded low-volt connectors (refer to figure 2).
Be certain you comply with your local electrical codes and
regulations. The power cable has a three-prong-style connector
on one end. This connector must be plugged into the matching
connector on the power unit. Plug the other end of the power
cable into the wall electrical outlet. You are now ready to check
the installation of the unit:
• Plug the hose into each inlet valve to be sure the electrical
contacts operate properly.
• Check the inlet valve for air leaks.
• Check each pipe connection for air leaks.
• Be sure the dirt receptacle is properly secured
to the power unit.
• Be sure the filter is properly installed in the power unit.
Your cleaning system is ready to use.
Your central vacuum system starts and stops automatically.
To turn the system on, plug the hose into a wall inlet valve. To turn it o, remove the hose from the valve
(refer to figure 3). Optional hoses may include an on/o button on handle for added convenience.
Electrical Fault Protection
The central vacuum system employs features that monitor the following
operating levels: AC voltage, current draw and circuit board temperature.
If the voltage is below or above standard operating voltage, high current
draw or locked rotor, the power unit will not operate. In this case the LED
next to the On/ O button will blink or go out until the problem ceases.
In the event any one of these problems happening, make sure all low-volt
switches are in the OFF position, then press the on/o button, unplug
hose, or wait for temperature to lower. If problems persist, contact the
authorized service center nearest you.
In the case of power failure, the power unit will return to its previous
state when power returns. For example, if a hose is plugged in with the
hose switch on, or a straight air hose is plugged into a wall valve, then
the power unit will turn back on. If the power unit was turned on at the
unit prior to power loss then the unit will not turn back on.
Inlet Valves
Plugging the hose into an inlet valve complete a low-voltage electrical circuit which activates a relay and
turns on the power unit. To turn o the power unit, unplug the hose from the inlet. When unplugging the
hose, hold the inlet cover open for a few seconds to allow suction to decrease and protect the inner seal.
An obstruction in the inlet valve may cause the power unit to continue to run after the hose has been
removed from the inlet. To shut down the power unit, check all the inlet valves and remove obstructions.
Figure 2
Figure 3

8 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
LCD INSTRUCTION
MAIN SCREEN
The main screen is shown when the system is connected to
an electrical outlet. This is the view most often displayed.
On this screen you see the time, temperature and system
performance.
At the bottom of the screen you see from left to right, the power
(o) icon, the left () and right () toggle arrow icons and the
Enter() icon. To scroll through the LCD menus, the button
directly below each corresponding icon will execute the
navigational feature.
USER SETUP
Your LCD enabled power unit provides the ability to customize the
temperature and time formats. Formats can be customized using
the USER SETUP menu. To enter the USER SETUP menu, press the
<Enter> button.
Temperature Customization
Use the Left and Right toggle buttons to select the temperature
format of either C or F. Once the correct format has been selected,
press the <Enter> button to proceed to the next screen.
Time Format Customization
Use the Left and Right toggle arrows to select the temperature
format of either 12 hour or 24 hours. Once the correct format has
been selected, press the <Enter> button to proceed to the next
screen.
Time Setting
The time can be changed by using the Left and Right toggle
buttons. The first number field in the display is underlined with
a bar, indicating that it can be adjusted with the toggle buttons.
Press the <Enter> button to proceed to the next number field.
Review User Setup Settings
The next screen displays the temperature and time with the user
selected formats. Press the <Enter> button to return to the Main
Screen
Power Button
Enter Button
Toggle Buttons

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 9
LCD INSTRUCTION
SYSTEM CHECKS
The system checks menu provides the ability to monitor overall
system. Specific areas monitored are the Empty Dirt Receptacle,
Airflow Level, Motor and Electrical System, and Service Indicator.
The happy face indicates that each monitored aspect of the power
unit is optimally performing. Use the right and left toggle buttons
to scroll through the SYSTEM CHECK screens.
Main Screen
Dirt Receptacle and Happy Face
The above display denotes that the dirt receptacle does NOT
currently need to be emptied.
Three to Five Performance Bars and Happy Face
This display indicates the system is performing at the optimal
airflow level. The power unit motor is operating at peak or
optimum performance when all five power bars are illuminated.
Normal operating performance is when three to five bars are
shown. Performance levels will decrease as the filter is loaded with
debris or as the motor has significant wear. Fewer bars will be
illuminated as performance decreases. When the power unit is o,
the display will illuminate the airflow level of the last operating
cycle. Note: It is also normal to see changes in performance when
specialty attachments are used.
Motor Icon and Happy Face
This display indicates all electrical and motor components are
functioning properly.
Telephone Icon and Happy Face
This screen indicates that the system has NOT encountered
any error conditions and it is NOT necessary to call for service
at this time.
System Run Time
This display shows you the overall number of hours that the power
unit has operated.

10 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
LCD INSTRUCTION
SYSTEM ALERTS
Your LCD enabled power unit is constantly monitoring the system
status. In the event of an error condition, a system alert will be
displayed on the LCD in place of the Main Screen.
The sad face indicates that the power unit has experienced an
error condition. The power unit may display the following Alerts:
Main Screen Appears Flashing
If the power unit receives an excess of electricity such as an over
current situation, the Main Screen will start flashing.
The flashing Main Screen indicates that the power unit has
automatically recovered from an error situation and will operate
properly when powered on.
Bucket Icon with Sad Face
This screen will be displayed when the dirt receptacle needs to
bechecked for emptying. After checking(and possibly emptying)
the bucket, press the <Enter> button to return to the Main Screen.
This will reset the timer for the bucket monitor.
Empty/Flashing Power Bars with Sad Face
This screen is displayed when the power unit motor is unable to
operate at optimal system performance. When only 2 bars or less
are illuminated, the airflow is restricted, meaning the vacuums
cleaning power has decreased. If the remaining bars are flashing,
the airflow restriction has been present for more than 12 minutes
of vacuuming and attention is urgent. Air flow can be restricted by
several factors:
1) Loaded Filter
(see “Filter Maintenance” section of the Power Unit Owner’s Manual)
2) System Blockage
(see “Trouble Shooting” section of the Power Unit Owner’s Manual)
3) Motor Wear
(contact an authorized Beam service technician)
The most common cause is a loaded filter, and the system
performance can be restored by cleaning the filter. Alternatively,
there may be a system blockage, and the hose and piping system
needs to be checked for blockage.

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 11
LCD INSTRUCTION
Motor Icon with Sad Face
This screen indicates that the motor has shut down due to an
electrical fault. When the system experiences an electrical failure
it will attempt to automatically reset after a 15 to 30 second delay.
Once recovered, the display will return to the flashing Main Screen,
indicating that the power unit has been reset and will operate
properly when powered on.
In the event that the system is unable to automatically reset, the
display will switch to the Phone Icon with a Sad Face screen,
indicating the need to contact a Beam dealer for service.
This indicates a motor failure, where service is needed.
Phone Icon with Sad Face
This screen will be displayed for either of two reasons:
1) The system experiences a failure that requires repairs by
an authorized Beam service technician.
2) The power unit reaches 500 hours in the life-cycle when
the motor brushes and filter should be checked for wear.
To resolve this system alert, contact a Beam dealer.
HINT: Changing the motor brushes is an inexpensive way to
increase the overall motor life and is recommended after 500
hours of operation.

12 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
Instructions provided in the booklet serve as a guide to routine maintenance. Proper airflow and suction
can be maintained by keeping the dirt receptacle and filter clean
and the plastic tubing and hose free from clogs.
Dirt Receptacle and Filter
Reduced airflow or suction indicates the central vacuum system is not
operating at maximum eciency. If the dirt receptacle is full and the filter
is clogged, no air can pass through the unit and no cleaning can take place.
CAUTION: Disconnect power the cord from electrical outlet before
removing the dirt receptacle. Some models feature see-through windows
on the receptacle to tell at a glance when the receptacle should be
emptied. To remove the receptacle, grasp the handles and turn the
receptacle to the left. Remove and empty the contents. Return the
receptacle and turn it to the right (refer to figure 4). To avoid suction
leakage make sure the receptacle is securely attached.
Filter Maintenance
BEAM’s exclusive filter is permanent and self-cleaning. However, if cleaning is desired, follow the steps
listed below:
NOTE: Do not operate this unit without the filter in place.
CAUTION: Disconnect power the cord from the electrical outlet before
removing the dirt receptacle.
1. Remove the dirt receptacle.
2. Wrap a large plastic bag around the lower portion of the power unit and
hold firmly in place.
3. Grasp the sewn-in weight at the bottom of the filter through the plastic
bag. Shake vigorously. Dirt will fall into the bag.
4. Carefully remove the bag from the unit. Place the empty dirt receptacle
on the power unit.
Cleaning Instruction Notice: Do not brush the filter.
Hint: Spilled dirt can be easily vacuumed by attaching the hose to the utility inlet on the power unit
and activating the manual switch.
Optional disposable paper bag
Your power unit may be equipped with a convenient paper bag, which can be simply discarded when
full. A full paper bag will deprive the power unit of proper suction and minimizes the performance of the
machine. Depending on how much use your central vacuum system it is recommended that you empty the
paper bag 2-3 times per year. Replacement bags can be purchased through your authorized central vacu-
um dealer/ distributor.
How to change the Paper Bag:
1. Unplug the power unit from all electrical sources.
2. Remove the bucket.
3. Remove the paper bag from the intake valve. (Optional two hole bag may be used when equipped with
an inlet valve on front of the unit)
4. Place and press the new bag into place. Turn the bag’s opening to lock it into place.
5. Place the bucket back on the power unit.
MAINTENANCE
Figure 4

ORIGINAL INSTRUCTIONS
DOC-703-INTBM_EN REV01 | 13
TROUBLESHOOTING
If you experience trouble with your central vacuum system, follow the suggestions below before calling
for service.
Partial loss of suction
1. Clean out dirt receptacle. Inspect and clean thw filter (see Filter Maintenance). Replace dirt receptacle.
2. Turn ON power the unit with on/o button. Then check the suction at each inlet. If it is not the same
at each one, the line is partially clogged. To locate the clogged area in the system, start with the inlet
closest to the power unit and check the suction. Continue to check each successive inlet until you
locate the inlet where a loss in suction is occurring. The clog will be between that inlet and the previous
one you checked. To remove the clog, carefully insert an electrician’s fish tape in the inlet and push the
obstruction through. Or, with another vacuum, you can reverse the suction in the system to remove the
clog. If neither method is successful, call your authorized BEAM dealer/distributor.
3. Have your authorized BEAM dealer/distributor check the gasket under the motor and the gasket located
where the dirt receptacle attaches to the upper cylinder.
Total Loss of Suction (with motor running)
1. Check the hose for obstruction.
2. Turn on the power unit with the on/o button and follow the same procedure as in step #2 above.
However, with a total loss of suction at all inlets, if the problem is a clog in the system, it would be
located between the power unit and first inlet.
Motor Refuses to Start
1. Check fuses or breakers (trip switches) in the electric panels in your house.
2. If your power unit has a control light, the solid green light will indicate when the unit has a proper
voltage and the low-voltage circuit is supplying power to the inlets.
3. If the green light is flashing, or does not light up, and the motor does not start, the power unit could
have experienced a fault due to excessively high or low standard operating voltage, high current draw,
or a locked rotor. If it also possible that the unit was powered on with a low-volt connection (i.e. Handle,
vac pan, etc) in the ON position. To resolve this issue:
a. Ensure all handles and vac pans are in the OFF position.
b. Unplug the power unit cord from the wall outlet, and then plug in again.
c. Press the on/o button on the power unit.
4. Should the light be on, but the motor starts only with the on/o button and not at the inlets, the
problem is broken low-voltage wiring to the wall inlets. Call your authorized BEAM dealer/distributor.

14 | DOC-703-INTBM_EN REV01
ORIGINAL INSTRUCTIONS
SERVICE INFORMATION
The instructions in this booklet serve as a guide for routine operation and maintenance.
For more information, contact your local authorized dealer/distributor.
Service Warranty
Warranty service is managed by your local authorized dealer/distributor.
Sold and serviced by:
2020.01.9
For additional product information
visit beamvac.com
Table of contents