1. Idenfy a posion which does not fall into “Zone 1” as shown.
Refers to the area above the bath or the shower,
up to a height of 2.25 metres.
The minimum rating required here is IPX5.
Covers an area of 0.6 metres wide immediately next
to, and all around “Zone 1”. Washbasins should
also be treated as “Zone 2”.
The minimum rating required here is IPX4.
Has no special requirements, unless water jets
are likely to be used for cleaning purposes.
Installaon Warning
If hard wiring this mirror, it must be installed by a qualied electrician in accordance with AS/ NZS 3000
wiring rules. Switch o the power supply at the mains before installaon and maintenance. A means of
disconnecon must be incorporated in the xed wiring in accordance with the wiring rules. If the supply cord
is damaged it must be replaced by the manufacturer, its service agent or similarly qualied person in order to
avoid a hazard.
Installaon Instrucons
Suitable for installaon in areas other than Zone 1 from below.
Rated IP44 for indoor use only.
ATTENTION: The mirror must be installed 15cm from nearest object to the boom right corner where the
Infrared On/ O sensor is located. Otherwise the sensor may not operate properly.