INSTALLATION
1. Select a location for the TANK that is level and below the condensate pan
drain.
2. The unit may be mounted on a wall by MULTI-SLOT METAL MOUNT TABS
on the tank, which are 8.0”, 8.35”, 9.33”, 10.3” or 10.65” apart.
3. The BULLSEYE LEVEL helps to confirm the pump is installed level.
4. Connect the CONDENSATE DRAIN, using flexible tubing or PVC pipe into
one of the four top inlets. When removing the inlet cover, make sure it does
not remain inside the tank. Be sure the tubing or pipe extends below the lid
1” or more but not all the way to the bottom (obstructing inlet flow or causing
a siphon).
5. Discharge connection to CHECK VALVE may be made with 3/8” vinyl tubing
secured by hose clamp (not included).
NOTE: If it becomes necessary to replace the check valve, a check valve
replacement kit is available. Instructions for installing are included in the
kit.
6. Once the DISCHARGE TUBING has been extended to the required height it
should be slanted downward, if possible, to assist drainage.
NOTE: For best results, do not extend discharge tubing beyond 17’
vertically for BK17 and 22’ for BK22. (Refer to performance chart.)
7. The SAFETY SWITCH leads should be connected for proper operation of
the pump. Using this feature may prevent damage from condensation over-
flowing if the discharge becomes blocked or pump fails. The leads may be
connected in series with the low voltage thermostat circuit to shut down
heating/air-conditioning system if water level in pump tank rises beyond
normal, or they may be connected to an external alarm.
8. To provide maximum mounting positions the tank LID may be removed and
rotated 180º so that check valve will be on the opposite side of the unit. To
remove the LID from the TANK, insert a slotted screwdriver in the lid’s slot
and pry the tank outward, while lifting the lid. After removing and rotating, be
sure LID snaps back into place firmly.
9. When all mounting and water connections are secure, connect unit to
electrical supply.
WARNING: This pump is supplied with a 3-prong grounding type
attachment plug. To reduce the risk of electric shock, connect only to a
properly grounded receptacle.
 Do not pump flammable liquids.
 Do not use this pump in explosive areas.
 Do not run dry.
 Do not handle unit with wet hands or while standing in water.
 Do not connect to any voltage other than that shown-on nameplate.
 Always disconnect this unit from its electrical supply before servicing.
 Connect safety switch for proper operation.
 For Indoor use only.
92374 Rev. 02
BECKETT CORPORATION
CONDENSATE REMOVAL PUMP
MODELS BK17 / BK22
BOMBA PARA REMOVER CONDENSACION
MODELOS BK17 / BK22
INSTALACIÓN
1. Seleccione un lugar para el TANQUE que esté a nivel y por debajo de la
bandeja de drenaje del condensado.
2. La unidad puede montarse en una pared usando las Lengüetas de montaje de
metal con ranuras múltiples, las cuales están separadas a 20.3 cm, 21.2cm,
23.7cm, 26.6cm o 27.1cm.
3. El nivel ojo de buey ayuda a confirmar que la bomba está instalada a nivel.
4. Conecte la bandeja de drenaje a uno de los 4 RANURAS, utilice tubería de
vinilo, PVC u otro material adecuado. Asegúrese de que la tubería se extienda
por debajo de la tapa 1” o más, pero no hasta el fondo (obstruyendo el flujo de
entrada o provocando un sifón).
5. La conexión de descarga a la VÁLVULA DE RETENCION se puede hacer con
tubería de vinilo de .95 cm asegurada con una abrazadera (no incluida).
NOTA: Si es hace necesario reemplazar la válvula de retención, está
disponible un juego de reemplazo. Las instrucciones para la instalación
están incluidas en el juego.
6. Una vez que la TUBERÍA DE DESCARGA ha sido extendida a la altura
necesaria, debe inclinarse hacia abajo, si es posible, para ayudar en el drenaje.
NOTA: Para mejores resultados, no extender la tubería de descarga
más de 5.2 m para la BK17 ni 6.7 m para la BK22 (Vea la cartilla de
rendimiento).
7. Las extensiones del CONMUTADOR DE SEGURIDAD deben ser conectadas
para la operación correcta de la bomba. Usando esta característica pueden
prevenirse daños a la bomba debido al desbordamiento del condensado si la
descarga se tupe o la bomba falla. Las extensiones pueden ser conectadas en
serie con el circuito del termostato de bajo voltaje de manera de detener el
sistema de calefacción / acondicionamiento de aire si el nivel del agua en el
tanque de la bomba se eleva más de lo normal, o los mismos pueden ser
conectados a una alarma exterior.
8. Para ofrecer posiciones máximas de montaje, la TAPA del tanque se puede
quitar y ser girada 180º, de manera que la válvula de retensión quede en el lado
opuesto de la unidad. Para retirar la tapa del tanque, insertar un destornillador
en la ranura y separar el tanque hacia un lado, mientras se eleva la tapa.
Después de retirar y girar, asegúrese de que la tapa engancha de nuevo
firmemente en su lugar.
9. Cuando todas las conexiones de montaje y agua estén aseguradas, conectar la
unidad al suministro eléctrico.
ADVERTENCIA: Esta bomba se provee de un enchufe de tres dientes del
accesorio del tipo que pone a tierra. Para reducir el riesgo de la descarga
eléctrica conecte solamente con un · correctamente puesto a tierra del
receptáculo.
 No bombean líquidos inflamables.
 Que él no utiliza esta bomba en áreas explosivas.
 No funcione seco.
 El no maneja la unidad con las manos mojadas o mientras que está parado
en del agua.
 No conecta con ningún voltaje con excepción de ése demostrado en la
desconexión del de la placa de identificación.
 Desconecte siempre esta unidad de su fuente eléctrica antes de mantener.
 Conecte el interruptor de seguridad para la operación apropiada.
 Para el uso de interior solamente.
AVERAGE PERFORMANCE / RENDIMIENTO MEDIO
Unit is not scaled
in perspective to
the pump.
4
9
6
5
2
8
10
7
BK22UL (230V)
BK22UL (115V)
BK17UL
10. To test pump operation, lift the TEST
TAB up and down to make sure the MAIN
SWITCH and MOTOR are working.
10. Para probar el funcionamiento de la bomba, levante la PALANCA DE
PRUEBA hacia arriba y hacia abajo para asegurarse de que el
INTERRUPTOR ELECTRICO PRINCIPAL y el MOTOR estén
trabajando.
3
GARANTÍA LIMITADA
Cada uno de los productos de Beckett Corporación (“Beckett”) está garantizado por el Periodo de Garantía
(como se define en esta garantía) que se menciona abajo, contra defectos en material y manufactura. El
Periodo de Garantía para cada producto comienza en el día de compra por el comprador original. El Periodo
de Garantía es el siguiente:
Tipo de Producto o Nombre Periodo de Garantía Tipo de Producto o Nombre Periodo de Garantía
Modelos de Bombas: Material Linear
FR Series, DP800-1200, G Series, FC Series...................2 años 35 mil PCV....................................20 años
BK17/22..........................................................3 años 40 Mil EPDM.................................20 años
Otros modelos de Bombas............................1 año 20 mil PVC ................................15 años
Estanques de Poly Pre-Formados…………15 años Filtro UV9/UV13…………................1 año
Vertedero de la Cascada y desnatador…...........................5 años Todos los demás productos Beckett...............90 días
APLICACIÓN: La garantía únicamente cubre los productos Beckett que hayan sido correctamente instalados
y mantenidos y se limita a la aplicación de fluidos para bombas a una temperatura normal 32º F a 86º F, (0º C
a 30º C) con una la especificación gravitacional de hasta 1.1. y con un pH dentro del rango de 5 a 9 (agua
fresca). Cualquier otra aplicación de líquidos o uso de temperaturas extremas debe ser aprobado previamente
por Beckett. La garantía no aplica o cubre daños o defectos causados por causas externas, incluyendo, pero
no limitándose a, instalación inapropiada o defectuosa, o modificaciones no autorizadas, tormentas eléctricas,
cambios de corriente eléctrica, abuso, uso no recomendado, uso anormal o aplicación incorrecta, incluyendo el
usar el producto de manera inconsistente con su finalidad. El comprador es responsable de determinar la
conveniencia del producto para el uso intencionado. Si el producto se daña en transito, cualquier queja o
demanda deber ser presentada con el transportista.
REMEDIOS: Si ha existido una falta en la garantía, Beckett, bajo su propia discreción, optará por reparar,
reemplazar, o generar un crédito o reembolso para la parte en particular disconforme. Reparar, reemplazar,
acreditar o rembolsar, a criterio de Beckett, será el único remedio en el caso que no se conforme a la garantía.
Los reclamos amparados por la garantía deben ser hechos dentro de los 3 meses siguientes a la expiración
del Periodo de Garantía.
ADMINISTRACIÓN: Los reclamos bajo la garantía deberán ser hechos regresando el producto defectuoso
con, gastos de envío prepagados, con comprobante de compra, a: Beckett Corporation, Customer Service
Dept., Irving, Texas, teléfono (888) 232-5388. Autorización telefónica por parte de Beckett es requerida antes
de regresar cualquier parte o producto inadecuado. Todos los productos o partes devueltas serán
inspeccionadas para determinar la causa de la falla antes de que se apruebe la garantía.
INSTALACIÓN, REMOCIÓN, Y/O GASTOS ENVÍOS: La garantía no incluye gasto asociados con la
instalación, remoción o flete de los productos sujetos a los reclamos bajo garantía.
RENUNCIAS Y LIMITACIONES: LA GARANTÍA EXPRESA Y LOS REMEDIOS DESCRITOS ARRIBA SON
LOS ÚNICOS Y EN LUGAR QUE CUALQUIER OTRA GARANTÍA O REMEDIOS, SEAN ORALES O
ESCRITOS, EXPRESOS O IMPLÍCITOS. DE LA MANERA MAS AMPLIA QUE PERMITA LA LEY, BECKETT
DE MANERA EXPRESA RENUNCIA CUALQUIER Y TODAS LAS GARANTÍAS IMPLÍCITAS, INCLUYENDO,
SIN LIMITACIÓN ALGUNA, LAS GARANTÍAS IMPLÍCITAS DE COMERCIALIDAD Y USO PARA UN FIN
ESPECIFICO. SI LAS GARANTÍAS IMPLÍCITAS NO PUEDEN SER RENUNCIADAS, TODAS LAS
GARANTÍAS IMPLÍCITAS ESTÁN LIMITADAS A LA DURACIÓN DE LA GARANTÍA EXPRESA APLICABLE.
BECKETT NO ACEPTA RESPONSABILIDAD SUPERIOR A LOS REMEDIOS MENCIONADOS DE MANERA
EXPRESA POR ESTA GARANTÍA. EN NINGÚN CASO BECKETT SERÁ CULPABLE O RESPONSABLE
POR DAÑO INCIDENTALES O CONSECUENCIALES. LA RESPONSABILIDAD AGREGADA DE BECKETT’S
BAJO ESTA GARANTÍA O RESPECTO A LOS PRODUCTOS CUBIERTOS POR LA MISMA, BAJO
CUALQUIER TEORÍA LEGAL, NO PODRÁN EXCEDER DEL PRECIO DE COMPRA PAGADO POR EL
PRODUCTO INADECUADO, LAS LIMITACIONES DE ESTE PÁRRAFO NO APLICARÁN A DAÑOS A
PERSONAS
Algunos Estados no permiten la exclusión o limitación de daños incidentales o daños consecuenciales o la
exclusión o limitación de la duración de las garantías implícitas, así que las limitaciones o exclusiones arriba
mencionadas pueden no aplican en su caso. Esta garantía te da derechos legales específicos y usted a lo
mejor tienes otros derechos que pueden variar de Estado a Estado.
Esta traducción se ha hecho de manera informativa para facilitar la lectura de la misma a personas que hablan
español. Sin embargo, la versión en Ingles es la versión que prevalece, por lo que la versión en Ingles regirá
cualquier reclamo de garantía entre usted y Beckett.
LIMITED WARRANTY
Each Beckett Corporation (“Beckett”) product is warranted to be free from defects in material and
workmanship for the applicable Warranty Period (herein so called) set forth below. The Warranty Period
for each product commences on the date of purchase by the original purchaser. The Warranty Periods
are as follows:
Product Type or Name Warranty Period Product Type or Name Warranty Period
Pump Models: Liner Material:
FR Series, DP800-1800, G Series, FC Series…………2 Years 35 mil PVC…………………………………..20 Years
BK17/22……………………………………. 3 Years 40 mil EPDM………………………...………20 Years
Other Pump Models………………………. 1 Year 20 mil PVC…………………………………..15 Years
Pre-Formed Poly Ponds……………………….……….15 Years UV9/UV13 Filter……………………………. 1 Year
Waterfall Weir & Skimmer……………………….……… 5 Years All Other Beckett Products.………………..90 Days
APPLICATION: The warranty covers only properly installed and maintained Beckett products and is
limited to application at normal temperature 32º F to 86º F, (0º C to 30º C) pumping fluids with a specific
gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme
temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover
damages or defects caused by external causes, including, but not limited to, improper or faulty installation
or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or
misapplication, including use in a manner inconsistent with the product’s intended function. The purchaser
is responsible for determining the suitability of the product for its intended use. If products are damaged in
transit, a claim should be filed with the carrier.
REMEDY: If there has been a failure to conform to the warranty, Beckett will, at Beckett’s option, repair,
replace or issue a credit or refund for the particular nonconforming product or part. Repair, replacement,
credit or refund, at Beckett’s option, is the exclusive remedy in the event of a failure to conform to the
warranty. Warranty claims must be made within 3 months after expiration of the applicable Warranty
Period.
ADMINISTRATION: Warranty claims must be made by returning the nonconforming Beckett product,
freight prepaid, along with proof of purchase, to: Beckett Corporation, Customer Service Dept., Irving,
Texas, telephone (888) 232-5388. Telephone authorization from Beckett is required prior to returning
nonconforming products or parts. All products or parts returned will be inspected to determine cause of
failure before warranty is approved.
INSTALLATION, REMOVAL AND/OR SHIPPING CHARGES: The warranty does not cover any costs
associated with the installation, removal or shipping of products subject to warranty claims.
DISCLAIMER AND LIMITATION: THE EXPRESS WARRANTY AND REMEDIES SET FORTH ABOVE
ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES AND REMEDIES, WHETHER ORAL OR
WRITTEN, EXPRESS, OR IMPLIED. TO THE FULL EXTENT PERMITTED BY LAW, BECKETT
EXPRESSLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION,
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
IF IMPLIED WARRANTIES CANNOT BE DISCLAIMED, ALL SUCH IMPLIED WARRANTIES ARE
LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY.
BECKETT DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES EXPRESSLY SET FORTH IN
THIS WARRANTY. IN NO EVENT SHALL BECKETT BE LIABLE OR RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES. BECKETT’S AGGREGATE LIABILITY UNDER THIS WARRANTY
OR WITH RESPECT TO ANY PRODUCT COVERED HEREBY, UNDER ANY LEGAL THEORY, SHALL
NOT EXCEED THE PURCHASE PRICE PAID FOR THE NONCONFORMING PRODUCT. THE
LIMITATIONS CONTAINED IN THIS PARAGRAPH SHALL NOT APPLY TO INJURY TO THE PERSON.
Some States do not allow the exclusion or limitation of incidental or consequential damages or exclusions
or limitations on the duration of an implied warranty, so the above limitations or exclusions may not apply
to you. This warranty gives you specific legal rights and you may also have other rights that vary from
State to State.
MAINTENANCE
WARNING:
DISCONNECT FROM ELECTRICAL SUPPLY BEFORE SERVICING.
All Beckett pumps are carefully tested prior to shipment to insure long,
trouble-free service. However, if pump is used in a dirty environment or is
pumping other than clear, condensate water, the tank should be removed
and cleaned periodically with soap and water. If pump fails to run, please
check the following:
 Be sure the pump is getting electrical power. Try another outlet to
be sure.
 Examine discharge tubing for any kinks or blockages. Also, be
certain that intake tubing or pipe is not obstructed.
 Disconnect power and remove the ENCLOSURE, item 2, and spin
the FAN, item 3, by hand to be sure that the motor is free.
 Be certain that the MAIN SWITCH, item 1, and the SAFETY
SWITCH, item 4, are fully “snapped” into their mounts.
 If further disassembly is required, push the sides, item 5, on both
ends, to remove the TANK, item 6.
 Examine the PUMP-CHECKVALVE ASSEMBLY, at its INTAKE,
item 7, for any obstructions. The CHECKVALVE, item 8, can be
removed by pressing the BLOCKING PLATE, item 9, and then
turning the CHECKVALVE counterclockwise.
MANTENIMIENTO
ADVERTENCIA:
DESCONECTE DE LA TOMA ELECTRICA ANTES DE DAR SERVICIO.
Todas las bombas Beckett son cuidadosamente probadas antes de su embarque para
asegurar largo servicio, libre de problemas. Sin embargo, si la bomba se usa en un
ambiente sucio, o se alimenta con otro líquido que no sea agua limpia, el tanque se debe
ser desmontando y limpiado periódicamente con agua y jabón. Si la bomba no funciona,
favor de ver lo siguiente.
 Asegúrese de que la bomba está recibiendo energía eléctrica. Probar en otra toma
eléctrica para estar seguro.
 Examine la tubería de descarga para ver si existen bloqueos o tubos doblados.
También asegúrese de que la tubería flexible o el tubo de entrada no esté obstruido.
 Desconecte la energía y retire la CUBIERTA, articulo 2, y mueva a mano el
VENTILADOR, articulo 3, para asegurarse de que el motor está libre.
 Asegúrese de que el INTERRUPTOR PRINCIPAL, articulo 4, y el INTERRUPTOR DE
SEGURIDAD, articulo 1, están completamente enganchados en sus montajes.
 Si se requiere más desmontaje, retire el TANQUE, articulo 6, desprendiendo con un
destornillador por las RANURAS, articulo 5.
 Examine el CONJUNTO DE BOMBA-VALVULA DE RETENCION, en su TOMA,
articulo 7, para ver si hay obstrucciones. La VÁLVULA DE RETENCIÓN, artículo 8, se
puede quitar presionando la PLACA DE BLOQUEO, artículo 9, y luego girando la
VÁLVULA DE RETENCIÓN en sentido contrario a las agujas del reloj.
3
2
8
5
7
1
6
O-Ring / Anillo O
Washer / Arandela
Duckbill Valve
Válvula De Duckbill
BECKETT CORPORATION
Irving, Texas
www.BeckettUS.com
Toll Free: 1-888-232-5388
© 2021 BECKETT CORPORATION All Rights Reserved
4
9

This manual suits for next models

5

Other Beckett Water Pump manuals

Beckett Fountain Pump M400AUL16 User manual

Beckett

Beckett Fountain Pump M400AUL16 User manual

Beckett CB15 User manual

Beckett

Beckett CB15 User manual

Beckett CB25 Series User manual

Beckett

Beckett CB25 Series User manual

Beckett CB15 User manual

Beckett

Beckett CB15 User manual

Beckett CB221UL User manual

Beckett

Beckett CB221UL User manual

Beckett CL201UL User manual

Beckett

Beckett CL201UL User manual

Beckett CB22 User manual

Beckett

Beckett CB22 User manual

Beckett M60A User manual

Beckett

Beckett M60A User manual

Beckett M90AUL User manual

Beckett

Beckett M90AUL User manual

Beckett Pond & Waterfall Pump W600 User manual

Beckett

Beckett Pond & Waterfall Pump W600 User manual

Beckett FC1200 User manual

Beckett

Beckett FC1200 User manual

Beckett DP80 Operation manual

Beckett

Beckett DP80 Operation manual

Beckett G210 User manual

Beckett

Beckett G210 User manual

Beckett Submersible Pump M250A User manual

Beckett

Beckett Submersible Pump M250A User manual

Beckett CB15 Series User manual

Beckett

Beckett CB15 Series User manual

Beckett Submersible Pump W800 User manual

Beckett

Beckett Submersible Pump W800 User manual

Beckett CB501ULHTS User manual

Beckett

Beckett CB501ULHTS User manual

Beckett CL201ULP User manual

Beckett

Beckett CL201ULP User manual

Beckett Fountain Pump M250AUL16 User manual

Beckett

Beckett Fountain Pump M250AUL16 User manual

Beckett CB20 User manual

Beckett

Beckett CB20 User manual

Beckett G325 Installation and user guide

Beckett

Beckett G325 Installation and user guide

Beckett DP800 User manual

Beckett

Beckett DP800 User manual

Beckett FC1250 User manual

Beckett

Beckett FC1250 User manual

Beckett BK17 User manual

Beckett

Beckett BK17 User manual

Popular Water Pump manuals by other brands

DROPSA SUMO II Series User and maintenance manual

DROPSA

DROPSA SUMO II Series User and maintenance manual

Graco 218334 instructions

Graco

Graco 218334 instructions

Emec TMS DC Series Operating instructions manual

Emec

Emec TMS DC Series Operating instructions manual

Mec-O-Matic VSP Series Installation, operation and maintenance manual

Mec-O-Matic

Mec-O-Matic VSP Series Installation, operation and maintenance manual

Edelbrock For Small Blaock Chevrolet V6&V8&V9 8882 General instructions

Edelbrock

Edelbrock For Small Blaock Chevrolet V6&V8&V9 8882 General instructions

Wilden PS 8 Stallion Metal Engineering, operation & maintenance

Wilden

Wilden PS 8 Stallion Metal Engineering, operation & maintenance

Grundfos CRE Series Installation and operating instructions

Grundfos

Grundfos CRE Series Installation and operating instructions

Grundfos PS.G instructions

Grundfos

Grundfos PS.G instructions

GORMAN-RUPP PUMPS SFSC6A Installation, operation and maintenance manual

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS SFSC6A Installation, operation and maintenance manual

Pentair Myers MW Series Installation and operation manual

Pentair

Pentair Myers MW Series Installation and operation manual

WSE WARRIOR 3050 owner's manual

WSE

WSE WARRIOR 3050 owner's manual

DAB 750 instruction manual

DAB

DAB 750 instruction manual

Espa Leader MP-10 instruction manual

Espa Leader

Espa Leader MP-10 instruction manual

KSB Amarex N F 80-220/034U LG-120 manual

KSB

KSB Amarex N F 80-220/034U LG-120 manual

BUSCH Mink MV 0310 B instruction manual

BUSCH

BUSCH Mink MV 0310 B instruction manual

WAGNER Twin Stroke 9140S owner's manual

WAGNER

WAGNER Twin Stroke 9140S owner's manual

Stac PF Operating and maintenance manual

Stac

Stac PF Operating and maintenance manual

Edwards nXDS Series instruction manual

Edwards

Edwards nXDS Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.