7
enables much flexibility to be bestowed onto the tape monitor signal path, not least being its ability to pick up
functions easily from the main channel. Also, during mixdown, when tape tracks are no longer monitored but
MIXED, the signal path between tape input and main channel is kept to a minimum.
Theconfiguration is24 into8into 24.This meansthatthere are24 channels,eight subgroups or“submixes” (or
four stereo subgroups) and 24 tape monitor returns, one for each channel. There are 24 100 mm channel
faders, eight subgroup faders, and a stereo pair of faders driving the L/R main mix.
In remix mode 48 channels are available, all with EQ and access to the aux buses. There are six additional
stereo FX returns, giving a grand total of 60 separate line-level inputs: and that’s before you even consider
using the subgroup insert points to provide eight more!
Thereare six aux buses accessed byfourpotentiometers, two headphone mixes andprofessionalrecording,
monitoringandtalkback facilities. If you can afford to lose the extra 24 lineinputs,theMIX-Bbus can also act
as a separate stereo aux send, giving eight aux buses in all.
A comprehensive set of inputs and outputs include MIC (+48 V), line, tape (+4 dBu or -10 dBV), inserts all
round, direct channel outs and all master recorder and monitoring options. Just about everything you’d
expectfrom a massive console.
Inaddition,a1/4"jackexpanderbay (INPUTONLY) allowsdirect patchinginto allbuses withinthe EURODESK
(exceptPFL andSOLO). HencetwoEURODESKs maybe linked,orthe EURODESKcoupled toANY OTHER
CONSOLE,large or small, provided that the otherconsolehas (or can be MADE to have)similaraccess (see
section19 “EXPANDING THE EURODESK”).
Last, and probably least, two BNC connectors on top of the built-in meterbridge await optional gooseneck
desklights, available from allgoodgooseneck desk light stores.Amust for those darkenedauditoria,or when
you’re into your third consecutive night in the studio.
2.2 Metering
The 1 to 24 channels have signal (-20 dB, L25) and overload LEDs (PEAK, L24).
The bulit-in meterbridge provides 12 segment bargraph meters for all channels and subgroups as well as for
the main mix. By the DISPLAY MODE switch (S100, top left of the master section) you decide between
CHANNEL and TAPE MODE. Your choice will be indicated by a LED.
In CHANNEL MODE, which is the best for live mixing purposes, the LED meters read the channel’s direct
OUTPUT, which is post EQ, post mute and post fader (you may alter that to pre mute and pre fader by the
modificationdescribed inAPPENDIXII.3).
In TAPE MODE the channel meters will mirror the multitrack’s meters, because they read the tape reutrn
inputs– after theOPERATINGLEVEL switch, butunaffectedby anything elsehappeningin the channel.0dB
is referenced to the selected tape operating level (+4 dBu or -10 dBV).
Themain mixmetersdouble upasmono PFLorstereo SOLOmeters,or 2-trackreturnmeters, orEXTERNAL
return meters (in general, what you HEAR is what you SEE). During PFL/SOLO only the main mix bargraph
metersilluminate.
+In SOLO/PFL mode a 0 dB meter reading matches an internal operating level of 0 dBu (0.775 V).
However, when looking at the mix, 0 dB is referenced to +4 dBu, the 2-track operating level. I.e.
if only ONE signal is present in the main mix bus, SOLOing that signal will cause the meter
reading to increase by +4 dB.
2.3 PSU (Power Supply Unit)
Notan infectionof theurinarytract, infact PSUstandsfor theleast glamorous,mostfrequently underestimated
feature of any electronic device: the POWER SUPPLY UNIT. The EURODESK remote PSU connects to the
desk at the rear of the console via a multiway connector. 2 1/2 U high, nevertheless it is designed to slot into
a3U rack space.The extra 1/2Uis toallowair to circulatearound the heatsinksemployedfor heatdissipation.
If your control room is small, forget heating. The EURODESK PSU chucks out a massive 400 Watts.