BerKAIR D9L User manual

D9L USER MANUAL

From German core technology

When people breathe, carbon dioxide is produced, so the proper
ventilation can replace air from the outside, and add oxygen to
reduce carbon dioxide inhalation.
Please be sure to replace the filter according to the suggested
time, to ensure that your BerKAIR air purifier is always in the best
working state.
Gentle reminder
Air purifier for improving indoor air quality has a very important
rolebut to thoroughly cure indoor air pollution problems, please
keep in mind the four major points:
BerKAIR air purifier can greatly improve the indoor air quality.
However,to reduce or eliminate indoor air pollution sources
is the most effective control way for the indoor air quality.
Introduction
Thank you for your choice.BerKAIR air purifier Read
all of these operatinginstructions carefully before
starting to use the air purifierThis will help you
betteroperate the product.
In order to bring you a clean and healthy air environment, we
suggest that 24 hours a day running BerKAIR air purifier,
continuous uninterrupted clean air output.

Catalog
Notice
BerKAIR air purifier is home appliances, before your first use, please
be sure to read the following safety instructions, in order to reduce
the risk of electric shock, fire or injury!
Notice
Use instrucions
Operation instruction
How to maintenance the air purifier
Troubleshooting guide
Warranty clause
Protection to Fix Card
This product is only used indoors under normal conditions;
Do not use this product in wet and high temperature environment (such as bathroom);
It is forbidden to insert any objects into openings on the device. If there is this situation, please
stop the machine, cut off the power and remove the foreign body. If need to repair please
contact BerKAIR customer service center or local service providers;
Before insert the plug, please carefully check the machine is equipped with the filter;
When replace the filter or cleaning the machine surface, be sure to disconnect the power supply;
Please do not use the non BerKAIR designated filter and other accessories;
In addition to replace the filter, do not disassemble or modify the product;
Do not sit, stand or prevent the heavy load on the air purifier;
Do not let children use or operate the machine, to avoid unnecessary injure;
Please unplug the device after every use, in case of the insulation caused by aging caused
electric shock or fire;
Do not operate the device in the highly flammable material area;
Never submerge the device in water or other liquids, do not clean it under running water, to
avoid electric shock or fire;
Before the product is switched on, first confirm the marked voltage is consistent with the local
voltage;
Do not knock the product with hard objects(especially the air inlet and outlet);
Please disconnect the power before cleaning the product;
Do not before closing the machine, pull off the power source!

Remove all the packages from the filters.
Remove all filters inside the product.
Open the panels of two side.
Use instrucions
Before you use the BerKAIR air purifier, please refer to the
operation instructions.
Open the two sind-panels and remove the filters;
Put back the side-panels.
Put back the pre-filters.
Replace the new filters as the picture.

Please put the power cord completely, put the BerKAIR air purifier in a dry and flat place . To
ensure that the air purifier from the wall or object at least 40 cm. In order to better realize the
whole space of the circulation of gas flow, otherwise it will reduce the air purifier purification
efficiency;
(Please check the power cord is intact, once damaged prohibit to use)
Confirm that the power plug is inserted inthree and has a grounding end, and then
connected to the power supply.
Touch upper right "on / off" button
Operation
instruction
Turn on/off the air purifier;
touch on/off key, the machine started
auto function, the auto indicator will light;
touch this key again the machine will be stop.
Touch “auto” key , machine into auto mode operation.
Users can perset or set the machine running time,
1-8 hours after the automatic open / shut down.
Press this key once, set time one hour, press this
key again to increase the operating time.
The maximum operating time that can be set is
8 hours.
For open or close anion function.
Touch sleep key, air quality indicator off, control
panel lights dimmed, the machine into the quiet
mode of operation.
Touch “auto” key again, sleep mode off, machine
into normal mode operation.
When the system starts, press the key for 3 seconds,
and the system switches between the locked and
unlocked states. The other keys are invalid after
the child lock is locked, and only the other keys
are valid after unlocking.
When the filter service life up to 48 hours before,
indicating a filter with red flashing exhibit of
lanterns to remind the user to replace the screen.
After the replacement of the filter press this key
until the flashing red lights.
The user can set the wind speed according to
the actual demand, touch this key , wind speed
will adjust by 1-4.
[Di] the sound, "on/off", "AUTO", "ANION", "air quality detection" indicators will light,
air purifier start intelligent function.
The fan operates at a moderate speed,"ANION" function opening.
Air quality detection system is turned on and the front of the machine "air quality
indicator lights” flashing green lights to display.
After five minutes the air quality detection system will be complete the
detection.Indoor air quality status is indicated by "air quality indicator" green,
yellow and red color.Automatic operation mode of machine , clean air.
Digital display
Color
Air Quality
1~75
Green
Very Good
76~150
Yellow
Good
More than 150
Red
Poor

Open the panels of two side.
power plug.
Press “on/off” key to turn off the machine, unplug the
When the purifier indicator panel on the "reset filter" flashing
lights,you need to replace the filter.
How to maintenance the air purifier
BerKAIR air purifier with filter replacement reminder function:
(※Notice: When you move, clean and replace the filters, be sure to disconnect the power supply.)
Put back the side-panels.
Put back the pre-filters.
Put the new complex filter in the direction of the arrow to
return to the product internally.
Take out the initial filter , pull out complex filter of filter online
auxiliary handle, and then remove the complex filter.

Connect power and start the purifier, press "Reset filter"
key 5 seconds,"Reset filter" indicator stop flashing.
Complete filter replacement.
Troubleshooting guide
Common problem and solution
Common problem
Solution
Can not turn on
May be power connection problem.
May be not press “on/off” key.
The front panel may not be properly installed.
Please reinstall the front panel.
The fan can not
operate normally
The front panel may not be properly installed,
Please reinstall the front panel.
Common problem
Solution
Fresh air can not
be sent out from
the outlet smoothly
Perhaps you forgot to remove the new filter plastic bag,
Please remove the plastic packaging.
The outlet may be blocked by foreign bodies.
Air filtration effect
is not good
High efficiency activated carbon filters may be
ineffective due to environmental factors.
If necessary, replace the filters.
You may be using this product's room air quality is very
poor.
In this case please open the window to improve the air
circulation.
You may use this product to exceed the use area of the
product.
Abnormal sound
operation process
Air inlet or outlet may be blocked by foreign objects.
Please move to block the air inlet or outlet of objects.
There may be a fault to repair products.

Warranty clause Protection to Fix Card
1 YEAR LIMITED WARRANTY(Except the Filter) Thank you very much for using our products.
This couplet and the purchasing invoice are both considered as the Protection to fix
warrantees, so please reserve them carefully.
Product Model Number
Product Name
Factory Serial Number
Purchase Store
Purchase Date
Invoice Number
Customer Name
Customer Phone
Customer Couplet
BerKAIR makes the following limited warranty to the original residential user or consumer
purchaser of the Air Purifier:
If any part of your Air Purifier motor fails during the first one (1) year from the date of installation
due to a defect in material or workmanship, we will provide a replacement Air Purifier free of
charge. Installation is deemed to occur at the date of purchase.
If the original residential user or consumer purchaser ceases to own the air purifier, this warranty
and any implied warranty which then remains in effect, including but not limited to any implied
warranty of merchantability or fitness for a particular purpose, are voided.
No warranty, expressed or implied, including any warranty of merchantability or fitness for a
particular purpose, is made in respect to the filter material or carbon filter.
This warranty is in lieu of allother express warranties. The duration of any implied warranty, including
but not limited to any implied warranty of merchantability or fitness for a particular purpose, in
respect to the motor is expressly limited to the period of the express warranty set forth above.
This warranty is voided if the air purifier is not purchased and used in China.
This warranty excludes and does not cover defects, malfunctions or failures of the Air Purifier which
were caused by repairs by persons not authorized by us, use of parts or accessories not authorized
by us, mishandling, modifications, or damage to the Air Purifier while in your possession, or
unreasonable use, including failure to provide reasonable and necessary maintenance.
This warranty does not cover Air Purifiers used in commercial applications. There are no express or
implied warranties as to commercial purchasers or users.


Table of contents
Popular Air Cleaner manuals by other brands

Coway
Coway Airmega 150 user manual

Second Wind
Second Wind 1625K installation manual

Flanders
Flanders Gas Turbine Rigid Filters Cell GT Specifications

EdenPURE
EdenPURE OxiLeaf II Thunderstorm user manual

Daikin
Daikin STREAMER C55WVM Operation manual

DH Lifelabs
DH Lifelabs AQUASOLVO AAHE-50WC04C quick start guide