BERKSHIRE HATHAWAY MARMON Cornelius User manual

PRISM
Owner’s Manual
Release Date: September 21, 2018
Publication Number: 548000037
Revision Date: May 9, 2023
Revision: H
Visit the Cornelius web site at www.cornelius.com for all your Literature needs.

Notice
The products, technical information, and instructions contained in this manual are subject to change without notice. These
instructions are not intended to cover all details or variations of the equipment, nor to provide for every possible contingency
in the installation, operation or maintenance of this equipment. This manual assumes that the person(s) working on the equip‐
ment have been trained and are skilled in working with electrical, plumbing, pneumatic, and mechanical equipment. It is
assumed that appropriate safety precautions are taken and that all local safety and construction requirements are being met,
in addition to the information contained in this manual.
This Product is warranted only as provided in Cornelius’ Commercial Warranty applicable to this Product and is subject to all of
the restrictions and limitations contained in the Commercial Warranty.
Cornelius will not be responsible for any repair, replacement or other service required by or loss or damage resulting from any
of the following occurrences, including but not limited to, (1) other than normal and proper use and normal service conditions
with respect to the Product, (2) improper voltage, (3) inadequate wiring, (4) abuse, (5) accident, (6) alteration, (7) misuse, (8)
neglect, (9) unauthorized repair or the failure to utilize suitably qualified and trained persons to perform service and/or repair
of the Product, (10) improper cleaning, (11) failure to follow installation, operating, cleaning or maintenance instructions, (12)
use of “non‐authorized” parts (i.e., parts that are not 100% compatible with the Product) which use voids the entire warranty,
(13) Product parts in contact with water or the product dispensed which are adversely impacted by changes in liquid scale or
chemical composition.
Correct Disposal of this Product
RECYCLE
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent
possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the
sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact
the retailer where the product was purchased. They can take this product for environmental safe recycling.
Trademarks and Copyrights
This document contains proprietary information and it may not be reproduced in any way without permission from Mar‐
mon FoodService Technologies Inc. This document contains the original instructions for the unit described.
MARMON FOODSERVICE TECHNOLOGIES INC
355 Kehoe Blvd
Carol Stream, IL
Tel: + 1 800‐238‐3600
Printed in U.S.
Contact Information
To inquire about current revisions of any documentation or assistance with any Cornelius product, contact:
www.marmonfoodservice.com
www.cornelius.com
800-238-3600

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. Publication Number: 548000037
TABLE OF CONTENTS
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Read and Follow all Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Different Types of Alerts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Safety Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Qualified Service Personnel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Prism . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Optifill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Sanitary Lever . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Push Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Portion Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Flavor Shots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Mixed Flavors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Cleaning Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Daily Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Setup Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
How to Check Prism Ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
How To Program Optifill Top‐Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
How To Program Portion Control Sizes and Top‐Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Flavor Shot Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Mixed Flavors Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Knock Out Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Knock Out Punch Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Knock Out Adapter Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Knock Out Adapter Plate And Tubing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Back Block Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Valve Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Locking Valve with Back Block Using Lock Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Connection Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Syrup and Water Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Touch Module And Cover Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Plumbing Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Illustrated Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Valve Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Prism Component Part Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .36
Prism Decal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37

Prism Owner’s Manual
Publication Number: 548000037 © 2023, Marmon Foodservice Technologies Inc.

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 1 ‐ Publication Number: 548000037
SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
Safety Overview
• Read and follow ALL SAFETY INSTRUCTIONS in this manual and any warning/caution labels on the unit (decals, labels or
laminated cards).
• Read and understand ALL applicable OSHA (Occupational Safety and Health Administration) safety regulations before
operating this unit.
• Must wear required PPE before you start to service or maintain the equipment.
Recognition
DIFFERENT TYPES OF ALERTS
!
DANGER:
Indicates an immediate hazardous situation which if not avoided WILL result in serious injury, death or equipment damage.
!
WARNING:
Indicates a potentially hazardous situation which, if not avoided, COULD result in serious injury, death, or equipment damage.
CAUTION:
!
Indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury or equipment damage.
SAFETY TIPS
• Carefully read and follow all safety messages in this manual and safety signs on the unit.
• Keep safety signs in good condition and replace missing or damaged items.
• Learn how to operate the unit and how to use the controls properly.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without supervision.
• Keep your unit in proper working condition and do not allow unauthorized modifications to the unit.
• Any modifications to be done by Factory Authorized Service personnel only.
• Any part replacement in the system shall be conducted with like components.
Recognize Safety Alerts
This is the safety alert symbol. When you see it in this manual or on the unit, be
alert to the potential of personal injury or damage to the unit.
!

Prism Owner’s Manual
Publication Number: 548000037 ‐ 2 ‐ © 2023, Marmon Foodservice Technologies Inc.
QUALIFIED SERVICE PERSONNEL
!
WARNING:
Only authorized service personnel shall service the valve. ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND
LOCAL CODES. FAILURE TO COMPLY COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE.
SAFETY PRECAUTIONS
This unit has been specifically designed to provide protection against personal injury. To ensure continued protection observe
the following:
!
WARNING:
Disconnect power to the unit before servicing following all lock out/tag out procedures established by the user. Verify all of the
power is off to the unit before any work is performed.
Failure to disconnect the power could result in serious injury, death or equipment damage.
CAUTION:
!
Always be sure to keep area around the valve clean and free of clutter.
Failure to keep this area clean may result in injury or equipment damage.

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 3 ‐ Publication Number: 548000037
OPERATION
PRISM
FRONT COVER
REAR VIEW
Plain or Carbonated water
Front Cover
Figure 1.
The Cornelius Prism is capable of dispensing 3 CARBONATED BRANDS / or 3 NON-CARBONATED BRANDS /or 3 FLAVORS
and comes with 6 variants as below, refer to Table 1 on page 4.
NOTE: Both carbonated and non carbonated beverages CANNOT BE DISPENSED IN THE SAME VALVE
Optifill
The user places a cup against the dispensing lever, press the brand, and the valve automatically shuts off after the cup begins
to overflow. Additionally, a top‐off pour can be programmed in this mode.
Sanitary Lever
The user manually dispenses a beverage by selecting a brand and then pressing the cup against the dispensing lever.
Push Button
The user manually dispenses a beverage by pressing the brand until the cup is full.
Portion Control
The user dispenses a beverage by pressing the brand button, then pressing a cup size button, and then the valve
automatically dispenses for a fixed time. Times are programmable, with an option to add top‐off
Flavor Shots
The user dispenses a flavor only by pressing the brand button, then pressing a cup size button, and then the valve
automatically dispenses for a fixed time. Line pressure must be set between 30‐35 PSIG for each flavor.

Prism Owner’s Manual
Publication Number: 548000037 ‐ 4 ‐ © 2023, Marmon Foodservice Technologies Inc.
Mixed Flavors
The user dispenses a flavor and beverage by pressing the brand button and a flavor button, then pressing a cup
size button, and then the valve automatically dispenses for a fixed time.
Table 1.
CLEANING INSTRUCTION
Daily Cleaning
1. Remove nozzle and diffuser from the valve and clean with warm, soapy water. Rinse with clean water. Soak parts in
sanitizing solution for 2 minutes, then install them back onto the valve, allowing the parts to air dry.
DIFFUSER
NOZZLE DIFFUSER
Figure 2.
2. Wash external surfaces with mild soap solution, rinse with clean water, and wipe dry.
NOTE: While cleaning the valve do not use abrasive or harsh cleaners on the unit.
NOTE: Diffuser is only compatible with Prism valve.
CAUTION:
!
All sanitizing solution must be drained from the system. A freezing ambient environment will cause residual sanitizing
solution or water remaining inside the valve to freeze resulting in damage to internal components.
SETUP INSTRUCTION
During this step, pour directly from the valve into the ratio cup. Pour water & syrup separately.
3. Enter into “brix mode” by adjusting the valve dip switch. Set the dip switches as shown in Figure 4. Press and release
the water button. The valve will dispense a preset amount of water. Adjust the flow rate using the valve flow control
until the flow rate is adjusted properly. After water is adjusted properly ‐ use the syrup buttons to dispense a preset
amount of syrup. Adjust the corresponding syrup flow control until the syrup flow rate is adjusted properly
Figure 3.
Part No. Description
Sanitary Lever Valves
620069112 Prism, Ceramic regulator, with mounting block and covers
Push Button Valves
620069114 Prism, Ceramic regulator, with mounting block and covers
Optifill Lever Valves
620069118 Prism, Ceramic regulator, with mounting block and covers
Portion Control / Mixed Flavor Valves
620069116 Prism, Ceramic regulator, with mounting block and covers
Flavor Shot Valves
620073990 Prism, Ceramic regulator, with mounting block and covers

DIP Switches
Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 5 ‐ Publication Number: 548000037
Figure 4.
NOTE: The DIP switches are located in the upper right hand corner of the back of the valve front cover.
Key 1 - Brand 1
Key 2 - Brand 2
Key 3 - Brand 3
Key 4 - Small
Key 5 - Medium
Key 6 - Large
Key 7 - X Large
Key 8 - Water
Key 9 - Cancel Pour
Key 10 - Pour
Key 11 - Program Mode

Prism Owner’s Manual
Publication Number: 548000037 ‐ 6 ‐ © 2023, Marmon Foodservice Technologies Inc.
HOW TO SET PRISM RATIO
Note: For proper setup of Flavor Shots, see section on “Flavor Shot Setup.”
CAUTION:
!
Do not expose the capacitive touch module wire to water.
Table 2.
Step Action Figure
1.
Remove the capacitive touch
module by lifting it upward and
pulling out. Remove the rear valve
cover. Leave the wire attached to
the capacitive touch module.
Figure 5.
2. Place the ratio cup under the
valve.
3.
Place the dip switch into “Brix
mode”.
Select the respective mode based
on the type of dispense.
After selecting “Brix mode,”
remember to power cycle the
valve by disconnecting and
reconnecting the white connector. Figure 6
4.
Press the water button to activate
a time dispense of 4.0 sec. Target
10oz into the water chamber of
the ratio cup.
NOTE: After the water flow is
adjusted, note the level of
the ratio cup. Do not adjust
the water again for the
syrup.
Figure 7.
Capacitive Touch Module
Val ve Bo dy
Rear Cover
Wires from valve body
to Capacitive touch modules
Ratio Cup

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 7 ‐ Publication Number: 548000037
5.
Press a brand to activate the timed
dispense into the proper syrup
chamber. If the syrup level doesn’t
fall within one band of the noted
water level, turn the adjustment
screw on the appropriate syrup
flow control counterclockwise to
decrease syrup flow or clockwise
to increase syrup flow. Dispense a
few drinks to verify the ratio. Re‐
adjust as necessary. Repeat for the
remaining flavors.
Figure 8
6.
Select the respective mode based
on the type of dispense.
After selecting the appropriate
dispense mode, power cycle the
valve by disconnecting and
reconnecting the white connector.
Figure 9.
7. Replace the rear valve cover and replace the capacitive touch module.

Prism Owner’s Manual
Publication Number: 548000037 ‐ 8 ‐ © 2023, Marmon Foodservice Technologies Inc.
HOW TO PROGRAM OPTIFILL TOP OFF
CAUTION:
!
Do not expose the capacitive touch module wire to water
NOTE: When program mode is enabled, the LED light in the bottom‐right corner will turn on and remain on until program
mode is disabled, at which point the LED light will turn off.
Programming Top-Off Delay
1.
2.
3.
4.
Table 3
Step Action Figure
Set the DIP switch to Optifill mode
as shown in Fig. 10.
Enter into “program mode” by
pressing the program button,
located in the bottom‐right corner
of the front cover, for 3 seconds
until the LED light turns on.
Important: if power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended.
Figure 10.
Press and release a desired Brand
button.
Place cup against the lever to allow
the valve to begin dispensing.
When the foam or liquid touches
the lever the valve will
automatically stop. This is the
initial pour. The cup must remain
in place with the lever pressed.
The LED light will flash at this time.
When the foam in the cup has
lowered, press and release the
desired brand button. The valve
will begin dispensing and will stop
when the foam or liquid touches
the lever. This is the top‐off pour.
The time between the end of the
initial pour and when the pour is
re‐started is the top‐off delay,
which is now stored in the PC
board. The LED light will be on
steady (no flash) at this time.
When finished, program additional
top‐offs by repeating steps 2 & 3,
or exit out of “program mode” by
pressing the program button,
located in the bottom‐right corner
of the front cover, for 3 seconds
until the LED light turns off.
Keep cup against
lever until liquid
touches lever
Location of
Program Button

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 9 ‐ Publication Number: 548000037
Disable Optifill Top-Off Delay
1.
2.
3.
4.
Table 4
Step Action Figure
Enter into “program mode” by
pressing the program button,
located in the bottom‐right corner
of the front cover, for 3 seconds
until the LED light turns on.
Important: if power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended.
Figure 11.
Press and release a desired Brand
button.
Place cup against the lever to allow
the valve to begin dispensing.
When the foam or liquid touches
the lever the valve will
automatically stop.
Remove the cup from against the
lever. This will enter a zero value
for the “top‐off” delay time and
disable a top‐off pour.
When finished, exit out of
“program mode” by pressing the
program button, located in the
bottom‐right corner of the front
cover, for 3 seconds until the LED
light turns off.
Keep cup against
lever until liquid
touches lever
Location of
Program Button

Prism Owner’s Manual
Publication Number: 548000037 ‐ 10 ‐ © 2023, Marmon Foodservice Technologies Inc.
HOW TO PROGRAM PORTION CONTROL SIZES & TOP-OFF
CAUTION:
!
Do not expose the capacitive touch module wire to water.
NOTE: If the “Cancel/Pour” button is held pouring for more than 30 s, the pour times out and stops flow. The pour
button must be release and re‐pressed to resume flow.
NOTE: When program mode is enabled, the LED light in the bottom‐right corner will turn on and remain on until program
mode is disabled, at which point the LED light will turn off.
Default Time Settings
The Prism valve Portion Controls are factory programmed with time values that can be useful during initial
installation and for testing the modules. The time values for each portion size are shown in the following ta*ble.
Portion Size Initial Pour Setting
Small “S” 2 s
Medium “M” 3 s
Large “L” 4 s
Extra‐Large “XL” 6 s
Programming the Portion Sizes
NOTE: It is recommended that when programming portion sizes, use actual cups and ice level.
Programming a Standard Pour
Table 5
Step Action Figure
1.
Set the DIP switch to Portion
Control mode as shown in Fig. 12.
After selecting “Portion Control
Mode,” remember to power cycle
the valve by disconnecting and
reconnecting the white connector.
Enter into “program mode” by
pressing the hidden program
button, at the bottom‐right corner
of the front cover, for 3 seconds
until the LED light turns on.
Important: if power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended.
Figure 12.
2.
Press and release a desired Brand
button.
Press and hold the portion size
button until the desired level is
reached in the cup; release the
button. Portion will be recorded
when program mode is exited.
Location of
Program Button
Portion Size Button
(S, M, L, XL)
Select appropriate

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 11 ‐ Publication Number: 548000037
Programming a Top-Off Pour
NOTE: It is recommended that when programming a top-off pour, use actual cups and ice level.
3.
Continue with other portion size
buttons or reset the same portion
size again.
4.
Program additional brands by
repeating steps 2 and 3, or when
complete, exit the program mode
by holding the hidden program
button for 3 seconds.
5. The last portion set for each
button is now recorded.
Table 6
Step Action Figure
1.
Enter the top‐off program mode
by holding the program button
(located in the bottom‐right corner
of the front cover) and “S”
together for 3 seconds until the
LED light turns on.
Note: To avoid accidental pour,
ensure the program button is
depressed slightly earlier than the
“S” Button.
Important: if power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended. Figure 13.
2.
Press and release a desired Brand
button.
Press and hold the portion size
button until the desired level is
reached in the cup, then release
the button.
Once the foam settles, press the
same button again to add a top‐off
pour. The initial pour, pause, and
top‐off will be recorded when the
program mode is exited.
3.
Continue with other portion size
buttons or reset the same portion
size again.
Note that the two dispenses and
pause between them will be saved
for each portion size when the top‐
off program mode is exited.
Table 5
Location of
Program Button
The “S” button.
Small portion size.

Prism Owner’s Manual
Publication Number: 548000037 ‐ 12 ‐ © 2023, Marmon Foodservice Technologies Inc.
4.
Program additional brands by
repeating steps 2 and 3, or when
complete, exit the program mode
by holding the hidden program
button for 3 seconds.
5.
The last portion, pause, and top‐
off for each button are now
recorded.
Note: It is possible to have some
portion sizes with a top‐off and
others without a top‐off.
Table 6

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 13 ‐ Publication Number: 548000037
Programming an Incremental Pour
The module will record the sum of all consecutive pours on a single portion as one, single pour with no pauses.
This is not the same as top‐off mode.
NOTE: It is recommended that when programming portion sizes, use actual cups and ice level.
1.
2.
3.
4.
Table 7
Step Action Figure
Enter the top‐off program mode by
holding the program button
(located in the bottom‐right corner
of the front cover) and “L”
together for 3 seconds until the
LED light turns on.
Note: To avoid accidental pour,
ensure the program button is
depressed slightly earlier than the
“L” Button.
Important: If power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended. Figure 14.
Press and release a desired Brand
button.
Press and hold the portion size
button to be programmed to
desired amount, and pause if
necessary for foam settling.
Figure 15.
Continue with other portion size buttons. The same portion size may be reprogrammed by either setting a
different size and returning to the size that needs to be reprogrammed, or tapping the cancel/pour button before
touching the size to be reprogrammed again.
Note that the last set of the consecutive pours’ sum will be saved for each portion size as a single pour without
pause when the incremental program mode is exited.
Program additional brands by repeating steps 2 and 3; or when complete, exit the incremental program mode by
holding the hidden program button for 3 seconds.
Note: It is possible to have some portion sizes that were created with a single pour, others created with multiple
pours.
Program
Button
Location
Cancel/Pour
Button
Select the
appropriate
portion size
(S, M, L or XL)
The “L” Button
(Large portion size)

Prism Owner’s Manual
Publication Number: 548000037 ‐ 14 ‐ © 2023, Marmon Foodservice Technologies Inc.
RESTORING DEFAULT TIME VALUES
The factory default standard pour time values can be restored using the following procedure.
1.
2.
3.
4.
5.
Table 8
Step Action Figure
Enter into “program mode” by
pressing the program button,
located in the bottom‐right corner
of the front cover, for 3 seconds
until the LED light turns on.
Figure 16.
Press and hold the “Cancel / Pour”
Button, then press and release a
desired Brand button. Release the
“Cancel / Pour” Button.
Press and release the desired
portion size button to be reset.
The LED light will flash to indicate
that the size will be reset.
Figure 17.
Release the “Cancel / Pour” Button. The time value listed in “Default Time Values” was restored to that size.
The “Cancel/Pour” Button must be released and re‐pressed before resetting another size.
Program additional brands by repeating steps 2 and 3; or when complete, exit the program mode by holding the
hidden program button for 3 seconds.
Program
Button
Location
Cancel/pour
button
Select the
appropriate
portion size
(S, M, L or XL)

Prism Owner’s Manual
© 2023, Marmon Foodservice Technologies Inc. ‐ 15 ‐ Publication Number: 548000037
ADJUSTING VALVE FLOW RATES VALUES
1.
2.
Table 9
Step Action Figure
If a flow rate re‐adjustment is
necessary for a Portion Control
valve, set the mode to "Brix
Mode" and follow the procedures
in the "How to Set Prism Ratio"
section above.
After selecting "Brix Mode,"
remember to power cycle the
valve by disconnecting and
reconnecting the white connector. Figure 18
When finished adjusting flow rate, remember to reprogram the portion size buttons at the new flow rate.
After re-selecting "Portion Control Mode," remember to power cycle the valve by disconnecting and
reconnecting the white connector.

Prism Owner’s Manual
Publication Number: 548000037 ‐ 16 ‐ © 2023, Marmon Foodservice Technologies Inc.
FLAVOR SHOT SETUP
CAUTION:
!
Do not expose the capacitive touch module wire to water.
Important:
1) The line pressure for flavors must be set between 30‐35 PSIG
2) This valve must use a standard nozzle (p/n 1945) and base plate (p/n 1903) to avoid flavor/color carryover
Default Time Settings
The Prism Flavor‐Shot mode is factory programmed with time values that can be useful during initial installation
and for testing the modules. The time values for each portion size are shown in the following table.
Portion Size Initial Pour Setting
Small “S” 1.8 s
Medium “M” 2.8 s
Large “L” 3.8 s
Extra‐Large “XL” 4.8 s
Setup Instructions
Table 10
Step Action Figure
1.
Set the DIP switch to Flavor Shot
mode as shown in Fig. 21. Power
cycle the valve by disconnecting
and reconnecting the white
connector.
Enter into Program Mode by
pressing the bottom right corner
for 3 seconds.
Important: if power to the valve is
turned off while programming,
perform a factory reset of the
valve after power is restored (see
“Restoring Default Time Values”
section). After the reset, program
the valve as intended.
Figure 19.
2. Tap to select a flavor and the flavor
will pour for 24s.
Program
Button
Table of contents
Other BERKSHIRE HATHAWAY Commercial Food Equipment manuals
Popular Commercial Food Equipment manuals by other brands

Winning appliances
Winning appliances BAR FRIDGES SK118L-B Operation manual

Villager
Villager VLN SC 350 Original instruction manual

Grainfather
Grainfather Conical Fermenter instructions

Polar Electro
Polar Electro UA017-A instruction manual

Diamond
Diamond ASM/185 Assembly instructions

Market Forge Industries
Market Forge Industries FTM-L Series Parts and service manual