BERL'S 4400DB User manual

4400DB_FTN_A LK4400DB_FTN_A
PAGE 1 1000003954 (Rev. A - 06/17)
Owners Manual
Model 4400DB
Tubular Fountain With Pet Fountain
4400DB Fountains are among the easiest to install Fountains on the market today.
To assure you install these models easily and correctly, PLEASE READ THESE
SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR
INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER
APPLICABLE CODES. After installation, leave these instructions with the Fountain for
future reference.
INSTALLER
BERLS.COM (704) 937-2673 129 Oakpark Drive, Unit A, Mooresville, NC 28115
COMMERCIAL
SUPPLY

PAGE 21000003954 (Rev. A - 06/17)
4400DB_FTN_A LK4400DB_FTN_A
1. This fountain is to be mounted on a smooth, at, nished surface with adequate support structure.
NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply, (Valve not furnished) (See Fig. 1).
4. Locate and install fountain using 3/8" minimum fasteners, (Fasteners not furnished).
5. Connect water supply and fountain drain. Connect drain waste "Tee" to fountain drain tubes. Connect outlet of "Tee" to
drainage system. Water connection and drain must comply with local codes.
6. Turn on water supply and check all connections for leaks.
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the
inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line
pressures lower than 20 PSI or higher than 105 PSI is not covered by warranty.
7. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve in
accordance with local code.
8. Connecting lines to be made of unplated copper and should be thoroughly ushed to remove all foreign matter before being
connected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor, color,
or sediment problems.
9. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and
the fountain. Remove any burrs from outside of water line. Push the tubes straight into the ttings until they reach a positive
stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE
O-RINGS MAY RESULT.
INSTALLATION INSTRUCTIONS
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES
IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE
BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN
ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE
WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN
FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE
FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
BERLS.COM (704) 937-2673 129 Oakpark Drive, Unit A, Mooresville, NC 28115
COMMERCIAL
SUPPLY

4400DB_FTN_A LK4400DB_FTN_A
PAGE 3 1000003954 (Rev. A - 06/17)
B
B
A
O14"
356mm
O1/2"
13mm (8 PL)
O12"
305mm B.C.
6 9/16"
167mm
12"
305mm
22"
559mm
40 5/16"
1025mm
8"
203mm
30"
762mm
41 7/16"
1053mm
2 5/8"
67mm
10"
254mm
O
26"
660mm
LEGEND
A = 3/8" O.D. UNPLATED COPPER TUBE CONNECT - SHUT OFF VALVE BY OTHERS
B = ACCESS PANEL (8" X 10")
FINISHED FLOOR
BERLS.COM (704) 937-2673 129 Oakpark Drive, Unit A, Mooresville, NC 28115
COMMERCIAL
SUPPLY

PAGE 41000003954 (Rev. A - 06/17)
4400DB_FTN_A LK4400DB_FTN_A
9
11
16
6
4
13
16
2
1
2
8
14
5
15
5
12
7
See Fig. 3
17
10
3
6
17
12
18
BERLS.COM (704) 937-2673 129 Oakpark Drive, Unit A, Mooresville, NC 28115
COMMERCIAL
SUPPLY

4400DB_FTN_A LK4400DB_FTN_A
PAGE 5 1000003954 (Rev. A - 06/17)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
ITEM
NO.
PART NO.
98683C
0000000325
101570540560
98530C
56092C
98682C
1000003694
1000003695
55996C
45725C
97446C
0000000466
45726C
1000003812*
98684C
45724C
70682C
28467C
97247C
45476C
ITEMIZED PARTS LIST
Kit - Drain Adapter/Gasket/Nut/Washer
Kit - Drain Plug & Gasket
Drain Gasket
Kit - Regulator/Holder/Nut
Poly Tubing (Cut To Length)
Kit - Push Button w/Blank Nameplate
Kit - Push Button w/LK4400DB Nameplate
Kit - Push Button w/4400DB Nameplate
In - Line Strainer
Tailpipe - 33" Lg.
Kit - Bubbler (VR)
Kit - Bubbler (Pet Fountain)
Drain Plug (Pet Fountain)
Access Panel
Kit - Pet Ftn Drain Elbow/Gasket/Nut/Washer
Tailpipe - 10" Lg.
Tee - 1/4"
Basin
Kit -VR Torx Screws/Bit
Drain Tube
DESCRIPTION
ACTUATION OF QUICK CONNECT WATER FITTINGS:
Fountain is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the tting, relieve water
pressure, push in on the gray collar while pulling on the tubing. (see
Fig.2) To insert tubing, push tube straight into tting until it reaches
a positive stop, approximately 3/4".
STREAM HEIGHT ADJUSTMENT:
Stream height is factory set at 35 PSI. If supply pressure
varies greatly from this, insert a small straight bladed
screwdriver through the access hole in the center of the
push button and turn the adjustment screw. Clockwise
adjustment will raise the stream and counterclockwise
adjustment will lower the stream. For best adjustment,
the stream should be approximately 1 1/2" above the
top of the bubbler . (See Fig. 4)
FIG. 4
PRINTED IN U.S.A.
Halsey Taylor – halseytaylor.com
Elkay – elkay.com
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL TECHNICAL SERVICES AT 1.800.834.4816
2222 CAMDEN COURT, OAK BROOK, ILLINOIS 60523
*select color option to complete part number
*FINISH COLOR OPTIONS – Choose color option to
complete your model number, add as sufx example:
4400DBEVG
Matte nish: Evergreen = EVG
Gloss nish:
Beige = BGE Gray = GRY Terracotta = TER
Black = BLK Orange = ORN White = WHT
Blue = BLU Purple = PUR Yellow = YLW
Brown = BRN Red = RED
FIG. 1
FIG. 2
B CA
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
A B C
1/4” O.D. TUBE
WATER INLET
TO COOLER
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
Vandal-Resistant Bubbler
FIG. 3
9
BASIN
BERLS.COM (704) 937-2673 129 Oakpark Drive, Unit A, Mooresville, NC 28115
COMMERCIAL
SUPPLY
Table of contents
Popular Outdoor Fountain manuals by other brands

Profi-pumpe
Profi-pumpe LOWEN-BRUNNEN operating instructions

Murdock
Murdock A172-SO Series Installation & maintenance instructions

Elkay
Elkay SWIRLFLO Series Installation, care & use manual

Silicon Solar
Silicon Solar AquaJetFL100 Technical data

Jeco
Jeco FCL178 quick start guide

Blumfeldt
Blumfeldt 10027997 manual