berlinger Fridge-tag 2 L User manual

User Manual
Fridge-tag 2 L
INTERNAL/EXTERNAL SENSOR

Content
1. ______________________________ 3
2. ______________________ 4
3. _______________ 4
4. ________________ 6
5. ________________________________ 7
6.
____________________
7. ________________ 22
____________________________ 23
_______________
________________
(30-day history)
(Alarm Super Jump funcon)
11. _____________________________ 42
12. __________________________ 42
13. ___________________________ 42
14. ___________________________ 43
1. Display explanaons
!
1-888
8808 2888
8888
min.
max. °F
°C
Int.SensorSensor
Ext.
Note
!
Int.
32

2. State of delivery / sleep mode
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
3. Read out informaon prior to acvaon
(in sleep mode)
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8
101 2026
P SS4n
Aer 2nd pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
C1d
0000 0 0
1 342
Aer 4th pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
80
1H
d r
u
1 000
°C
Aer 5th pressing of READ*
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
-05
0L
d r
u
0 001
°C
Aer 6th pressing of READ*
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Aer 10th pressing of READ
Aer 7th pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
0500 00
3491
S
Aer 8th pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
0484 13
0051
PCb
Aer 9th pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
CP
4
n
100.0
Aer 3rd pressing of READ
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
58
°C
Int.Sensor
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
258
°C
Sensor
Ext.
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
--.-
°C
1 218
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
!
1-888
8808 2888
8888
min.
max. °F
°C
Int.Sensor
Ext.
Aer 1st pressing of READ
54

4. Placing the Fridge-tag 2 L
Placing the Fridge-tag 2 L with an internal sensor
Placing the Fridge-tag 2 L with an external sensor
1
2
3
1
2
3
5. Acvaon process
5.1. Overview: sequences of acvaon
Note
76

Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
yyyd y__d
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
5.3. Seng the calendar format
Opon 1
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
yyyd y__d
5.2. Acvaon of the device
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
yyy_ ydd_
1
2
Opon 2
Aer seng the calendar format, the rst digit of the date will
start ashing.
5.4. Using the READ and the SET buons
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Note

1
1
2
2
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
5.5. Seng the date
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1
1
2
2
2
Note
1
11

Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1
2
Aer seng the date, the rst digit of the me will start
ashing.
5.6. Seng the me
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1 000
1
2
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1 003
1
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1 403
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
1 473
1
1
2
2
2
1312

Note
As soon as the last digit of the me seng is conrmed, the
acvaon is completed.
Internal sensor
External sensor
5.7. Seng the alarm limits
(not standard, only if preset by factory)
1. and 3. Seng the HI and LO alarm duraons, they are
completed in the same manner
1. Seng the duraon of the upper alarm limit
2. Seng the temperature of the upper alarm limit
3. Seng the duraon to the lower alarm limit
4. Seng the temperature of the lower alarm limit
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
1H
d r
u
0 001
1
2
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
1H
d r
u
0 002
1
2
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
1H
d r
u
0 001
1
2
The duraon of the alarm limit is now set.
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
1H
d r
u
0 001
1
2
2. and 4. Seng the HI and LO alarm temperatures, they are
completed in the same manner
Internal sensor
External sensor
Note
1514

Instrucon for seng a posive temperature limit between
0°C/0°F and +50°C/+122°F (internal sensor) or 0°C/0°F and
+55°C/+131°F (external sensor)
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
80
1H
°C
1
2
is
Instrucon for seng a posive Fahrenheit temperature limit
equal or above +100°F
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
11 80 0
1H
°F
1
2
Seng a negave temperature limit below 0°C/0°F
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
-80
°C
1H
1
2
As soon as the last digit of the lower alarm limit is conrmed,
the acvaon is completed.
Internal sensor
External sensor
Note
As soon as the parameters of the upper alarm limit are set,
the rst digit of the duraon of the lower alarm limit will start
ashing. Proceed the same way as you did with the upper alarm
limit.
1716

5.8. Connecon error (external sensor only)
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
--.-
°C
1 218
Sensor
Ext.
•
•
•
•
5.8.1. How to x the connecon error
1.
2.
Note
Display status
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
810
1
2
026
56
1 278
°C
Sensor
Ext.
6.1. Overview: menu
Note:
6. Read and change sengs /
How to correct seng mistakes

You entered the menu mode and may choose which entry to
see or change.
You can access the following 4 menus:
OUTSIDE (external sensor)
SET DATE (internal sensor)
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
12
3
6.2. Inial menu (read and change sengs)
6.2.2. Access the menu “READ CONF”
6.2.3. Access the menu “CELS FAHR”
6.2.4. Access the menu “SET CONF”*
External sensor
Internal sensor
Note
6.2.1. Access the menu “SET DATE”
21

7.1. Example OK display – during measurement
7. Screen displays during
measurement mode
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
56
1 473
°C
Int.Sensor
7.2. Example alarm display – during measurement
•
•
•
!
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
88
1 425
°C
Int.Sensor
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
d r
u
---
0 000
max.
°C
Sensor
Int.Sensor
8. Alarm trigger funcon
8.1. Single-event alarm triggering
Upper alarm triggering
Seng upper limit
Alarm triggered
!
No Alarm triggered
2322

Lower alarm triggering
Seng lower limit
Alarm triggered
!
No Alarm triggered
8.2. Alarm display and conrmaon opons
Opon 1
!
Note
•
•
•
!
•
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
88
1 425
°C
Int.Sensor
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
88
1 425
°C
Int.Sensor
2524

Opon 2
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
8101 2026
56
1 473
°C
Int.Sensor
Conrmaon opons of currently triggered alarms of
the day
Device is within the set alarm limits
!
!
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
88
1 425
°C
Int.Sensor
1.
!
.
2.
!
3.
2. Device is outside the set alarm limits:
!
1.
!
2.
3.
!
Sengs
Sengs
Note
!
2726

•
•
•
•
9. Audio alarm (oponal factory seng)
8.3. Cumulave daily me above/below the limit
Note
Example setup
• OK
• ashing
low
•
+2.9˚C
•
00:00
Example of an OK display during readout of the history
• OK
• ashing
high
• +10.5˚C
•
00:32;
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
d r
u
105
0 320
max.
°C
Int.Sensor
10.1. Opon 1: Read out day per day
directly on the device (30-day history)
10. Reading the history / Readout mode
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
d r
u
29
0 000
min. °C
Int.Sensor
Note

Example of an alarm display during readout of the history
• alarm- warning
!
• alarm lower alarm limit
• –5d
• 16.02.2018
• 18:21
Note:
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
1 21
:
8
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
-
d r
u
11
0 351
min.
Int.Sensor
• alarm warning
!
• alarm higher alarm limit
• –5d)
• 16.02.2018)
• 20:30)
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
8101 2026
2 300
Int.Sensor
least 3 seconds.
10.2. Opon 2:
Read out alarms directly on the device – use
the Alarm Super Jump funcon (30-day history)
• –1.1˚C)
•
01:35
• internal sensor
31

• +10.5˚C)
•
11:24
• internal sensor
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
d r
u
!
105
1 241
max.
°C
Int.Sensor
Note
3 seconds
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
!
Int.Sensor
8101 2020
1 433
Note
10.3. Opon 3: Read out data from the les generated
by the Fridge-tag 2 L by connecng it with a
computer
USB connecon of the Fridge-tag 2 L
Note
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Temperature (min/max)
< 8°C
(15min)
> 25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
Temperature (min/max)
< 8°C
(15min)
>25°C
(15min)
0123456789012
-27d
-25d
-23d
-21d
-19d
-17d
-15d
-13d
-11d
-9d
-7d
-5d
-3d
yesterd.
-29d
-28d
-26d
-24d
-22d
-20d
-18d
-16d
-14d
-12d
-10d
-8d
-6d
-4d
-2d
today
Time / Alarm duration
Alarm state
= OK
= ALARM
Fridge-tag
®
dd.mm.yyyy
3332

Note
Note
FT-2L (F:)
FT-2L (F:)
FT-2L (F:)
1 Today
+1.8°C ALARM! -1.0°C 11h 4min 00:00h In progress +5.8°C 0min In progress
2 01/05/2018+1.5°C ALARM! -0.8°C 17h 29min 00:00h ok +5.7°C 0min ok 0min
3 01/04/2018+1.5°C ALARM! -1.0°C 15h 1min 00:26h ok +4.5°C 0min ok 0min
4 01/03/2018+2.0°C ALARM! -0.1°C 16h 9min 00:00h ok +6.4°C 0min ok 0min
5 01/02/2018+1.7°C ALARM! -1.1°C 14h 54min 00:00h ok +7.5°C 0min ok 0min
6 01/01/2018+2.3°C ALARM! -0.7°C 9h 35min 06:19h ok +5.5°C 0min ok 0min
7 12/31/2017+0.9°C ALARM! -5.3°C 9h 24min 00:00h ok +5.3°C 0min ok 0min
8 12/30/2017-1.7°C ALARM! -5.1°C 22h 46min 00:01h ok +2.5°C 0min ok 0min
9 12/29/2017+0.9°C ALARM! -4.2°C 13h 22min 00:00h ALARM! +8.5°C 14min 13:48h ok 0min
10 12/28/2017-0.3°C ALARM! -3.4°C 20h 1min 00:00h ok +6.0°C 0min ok 0min
11 12/27/2017+0.0°C ALARM! -2.9°C 19h 42min 00:00h ok +5.9°C 0min ok 0min
12
12/26/2017
+0.0°C ALARM! -2.2°C 19h 47min 00:00h ok +6.4°C 0min ok 0min
13 12/25/2017+2.3°C ALARM! -0.5°C 13h 19min 02:28h ALARM! +8.3°C 24min 12:51h ok 0min
14 12/24/2017+2.4°C ALARM! -1.2°C 11h 14min 00:00h ALARM! +8.6°C 30min 10:59h ok 0min
15 12/23/2017+3.3°C ALARM! -1.3°C 10h 34min 00:00h ALARM! +11.0°C 2h 55min 12:05h ok 0min
16 12/22/2017a,19:35 +3.3°C ALARM -0.5°C 7h 25min 06:37h ALARM +8.2°C 13min 12:53h ok 0min
17 12/21/2017+5.0°C ALARM +1.7°C 38min 22:41h ALARM +8.3°C 32min 09:30h ok 0min
18 12/20/2017+3.1°C ALARM +0.3°C 10h 32min 00:00h ALARM +10.2°C 2h 38min 11:27h ok 0min
19 12/19/2017+4.0°C ALARM +0.7°C 7h 33min 05:36h ALARM +9.3°C 3h 4min 10:29h ok 0min
20 12/18/2017+5.4°C ALARM +0.4°C 4h 9min 00:00h ALARM +10.8°C 4h 54min 10:03h ok 0min
21 12/17/2017+4.6°C ALARM +1.1°C 3h 18min 18:54h ALARM +8.8°C 1h 36min 11:57h ok 0min
22 12/16/2017+5.3°C ALARM +1.9°C 3min 00:11h ALARM +9.0°C 1h 14min 11:43h ok 0min
23 12/15/2017+0.5°C ALARM -2.8°C 14h 59min 00:00h ok +5.1°C 0min ok 0min
24 12/14/2017-1.2°C ALARM -4.1°C 20h 57min 00:01h ok +4.1°C 0min ok 0min
25 12/13/2017-2.1°C ALARM -5.7°C 21h 53min 00:00h ok +3.1°C 0min ok 0min
26 12/12/2017+0.3°C ALARM -4.5°C 19h 1min 00:00h ok +5.1°C 0min ok 0min
27 12/11/2017-0.5°C ALARM -1.7°C 5h 34min 18:27h ok +1.4°C 0min ALARM 18h 26min 00:00h
28 12/10/2017+26.6°C ok +25.3°C 0min ALARM +27.5°C 2h 20min 13:42h ALARM 8h 16:16h
Page 1/8
Logging interval:
5min
Measurement interval:
1)
Lower alarm limit:
Upper alarm limit:
Activation date:
Date and time of report creation:
Identification number:
510500000006
12/10/201720:37h
01/05/2018 13:40h
Above +8.0°C for 1min
Below +2.0°C for 1min
1min (fixed)
PDF document of the Fridge-tag® 2 L
No. Date
(MM/dd/yyyy)
Events2) Average
temp.
Status
Lower alarm limit
Min.
temp.
Cumulative
daily time
below the limit
Alarm
trigger
time
Status
Upper alarm limit
Max.
temp.
Cumulative
daily time
above the limit
Alarm
trigger
time
Status
Ext. sensor connection error
Duration Alarm
trigger
time
Signature / notes
Action taken
1) Sampling and data analysis every minute
2) t = time / date changed, a = alarm configuration changed, hh:mm = status checked
Date and place: ____________________________ Signature: ____________________________
Low battery since:12/25/2017
12/11/2017
23h 59min 08:27h
10.4. PDF report explanaon
Document tle and device
type
Device ID and self-explaining
informaon
Alarm sengs
Measuring and logging
interval
Event and alarm table (latest
info in line 1, top line)
Up to 3 user-denable strings
(max. 30 characters each).
Factory preseng
Placeholder for notes
Note 1: Reference for ma-
surement interval
Note 2: Legend for events
column (hh:mm --> 1 me
stamp/half day)
Placeholder for date and
signature
Baery warning with
mestamp
Test String 2
Test String 3
34
35

Graph 1 Graph 2
Graph 3 Graph 4
Page 2/2
Date and time of report creation: 01/06/2016 20:37h
Identification number:
510500000006
PDF document of the Fridge-tag® 2 L
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
Alarm limits
12/10/2017- 12/16/201712/17/2017- 12/24/2017
12/25/2017- 01/01/2018 01/02/2018 - 01/09/2018
12/16/2017
00:00
12/145/2017
00:00
12/10/2017
00:00
12/13/2017
00:00
12/12/2017
00:00
12/11/2017
00:00
12/10/2017
00:00
12/24/2017
00:00
12/23/2017
00:00
12/22/2017
00:00
12/21/2017
00:00
12/20/2017
00:00
12/19/2017
00:00
12/18/2017
00:00
12/17/2017
00:00
01/01/2018
00:00
01/31/2017
00:00
12/30/2017
00:00
12/29/2017
00:00
12/28/2017
00:00
12/27/2017
00:00
12/26/2017
00:00
12/25/2017
00:00
01/09/2018
00:00
01/08/2018
00:00
01/07/2018
00:00
01/06/2018
00:00
01/05/2018
00:00
01/04/2018
00:00
01/03/2018
00:00
01/02/2018
00:00
Each graph shows data
from a period of 7 days
Incrementally numbered
graphs
Temperature scale
Time scale
Alarm limits
Alarm limits
Date change posive
Date change negave
Time change posive
(e.g. summer/winter me)
Time change negave
(e.g. summer/winter me)
Graph 1 12/10/2017 - 12/16/2017 Graph 2 12/17/2017 - 12/24/2017
Graph 3 12/25/2017 - 01/01/2018 Graph 4 01/02/2018 - 01/09/2018
Page 2/8
Date and time of report creation: 01/01/2001 04:05h
Identification number:
ser123
PDF document of the Fridge-tag® 2 L
t
T
-40.0°F
-20.0°F
+0.0°F
-20.0°F
+40.0°F
+60.0°F
+80.0°F
+100°F
+120°F
+140°F
t
T
-40.0°F
-20.0°F
+0.0°F
-20.0°F
+40.0°F
+60.0°F
+80.0°F
+100°F
+120°F
+140°F
t
T
-40.0°F
-20.0°F
+0.0°F
-20.0°F
+40.0°F
+60.0°F
+80.0°F
+100°F
+120°F
+140°F
t
T
-40.0°F
-20.0°F
+0.0°F
-20.0°F
+40.0°F
+60.0°F
+80.0°F
+100°F
+120°F
+140°F
12/16/2017
00:00
12/145/2017
00:00
12/10/2017
00:00
12/13/2017
00:00
12/12/2017
00:00
12/11/2017
00:00
12/10/2017
00:00
12/24/2017
00:00
12/23/2017
00:00
12/22/2017
00:00
12/21/2017
00:00
12/20/2017
00:00
12/19/2017
00:00
12/18/2017
00:00
12/17/2017
00:00
01/01/2018
00:00
01/31/2017
00:00
12/30/2017
00:00
12/29/2017
00:00
12/28/2017
00:00
12/27/2017
00:00
12/26/2017
00:00
12/25/2017
00:00
01/09/2018
00:00
01/08/2018
00:00
01/07/2018
00:00
01/06/2018
00:00
01/05/2018
00:00
01/04/2018
00:00
01/03/2018
00:00
01/02/2018
00:00
1
2
3
4
36
37

10.5. Autoscaling of graphs in PDF
The graph of the report is created dynamically depending on
the following sengs
•
•
This is valid for all graphs in the PDF le unl
•
•
Graph 1 10.12.17 - 16.12.2017
28.02.2018
00:00
27.02.2018
00:00
26.02.2018
00:00
25.02.2018
00:00
24.02.2018
00:00
23.02.2018
00:00
22.02.2018
00:00
21.02.2018
00:00
Graph 2 21.02.2018 - 27.02.2018
Graph 3 Graph 4
Alarm limits Page 2/8
Date and time of report creation:
Identification number:
PDF document of the Fridge-tag® 2 L
t
T
-5.0°C
+0.0°C
+5.0°C
+10.0°C
+15.0°C
+20.0°C
+25.0°C
+30.0°C
+35.0°C
+40.0°C
t
T
-5.0°C
+0.0°C
+5.0°C
+10.0°C
+15.0°C
+20.0°C
+25.0°C
+30.0°C
+35.0°C
+40.0°C
t
T
-5.0°C
+0.0°C
+5.0°C
+10.0°C
+15.0°C
+20.0°C
+25.0°C
+30.0°C
+35.0°C
+40.0°C
t
T
-5.0°C
+0.0°C
+5.0°C
+10.0°C
+15.0°C
+20.0°C
+25.0°C
+30.0°C
+35.0°C
+40.0°C
510500000006
01.06.2018 20:37h )
16.12.2017
00:00
15.12.2017
00:00
14.12.2017
00:00
13.12.2017
00:00
12.12.2017
00:00
11.12.2017
00:00
10.12.2017
00:00
Graph 1
28.02.2018
00:00
27.02.2018
00:00
26.02.2018
00:00
25.02.2018
00:00
24.02.2018
00:00
23.02.2018
00:00
22.02.2018
00:00
21.02.2018
00:00
Graph 2 21.02.2018 - 27.02.2018
Graph 3 Graph 4
Alarm limits Page 2/8
Date and time of report creation:
Identification number:
PDF document of the Fridge-tag® 2 L
t
T
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
+60.0°C
t
T
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
+60.0°C
t
T
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
+60.0°C
t
T
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
+60.0°C
10.12.2017- 16.12.2017
510500000006
01/06/2018 20:37h )
16.12.2017
00:00
15.12.2017
00:00
14.12.2017
00:00
13.12.2017
00:00
12.12.2017
00:00
11.12.2017
00:00
10.12.2017
00:00
Example below
Example below
1 Today +1.8°C ALARM! -1.0°C 11h 4min 00:00h In progress +5.8°C 0min
In progress 0min
2 01/05/2016 +1.5°C ALARM! -0.8°C 17h 29min 00:00h ok +5.7°C 0min
ok 0min
3 01/04/2016 +1.5°C ALARM! -1.0°C 15h 1min 00:26h ok +4.5°C 0min
ok 0min
4 01/03/2016 +2.0°C ALARM! -0.1°C 16h 9min 00:00h ok +6.4°C 0min
ok 0min
5 01/02/2016 +1.7°C ALARM! -1.1°C 14h 54min 00:00h ok +7.5°C 0min
ok 0min
6 01/01/2016 +2.3°C ALARM! -0.7°C 9h 35min 06:19h ok +5.5°C 0min
ok 0min
7 12/31/2015 +0.9°C ALARM! -5.3°C 9h 24min 00:00h ok +5.3°C 0min
ok 0min
8 12/30/2015 -1.7°C ALARM! -5.1°C 22h 46min 00:01h ok +2.5°C 0min
ok 0min
9 12/29/2015 +0.9°C ALARM! -4.2°C 13h 22min 00:00h ALARM! +8.5°C 14min 13:48h
ok 0min
10 12/28/2015 -0.3°C ALARM! -3.4°C 20h 1min 00:00h ok +6.0°C 0min
ok 0min
11 12/27/2015 +0.0°C ALARM! -2.9°C 19h 42min 00:00h ok +5.9°C 0min
ok 0min
12 12/26/2015 +0.0°C ALARM! -2.2°C 19h 47min 00:00h ok +6.4°C 0min
ok 0min
13 12/25/2015 +2.3°C ALARM! -0.5°C 13h 19min 02:28h ALARM! +8.3°C 24min 12:51h
ok 0min
14 12/24/2015 +2.4°C ALARM! -1.2°C 11h 14min 00:00h ALARM! +8.6°C 30min 10:59h
ok 0min
15 12/23/2015 +3.3°C ALARM! -1.3°C 10h 34min 00:00h ALARM! +11.0°C 2h 55min 12:05h
ok 0min
16 12/22/2015 a,19:35 +3.3°C ALARM -0.5°C 7h 25min 06:37h ALARM +8.2°C 13min 12:53h
ok 0min
17 12/21/2015 +5.0°C ALARM +1.7°C 38min 22:41h ALARM +8.3°C 32min 09:30h
ok 0min
18 12/20/2015 +3.1°C ALARM +0.3°C 10h 32min 00:00h ALARM +10.2°C 2h 38min 11:27h
ok 0min
19 12/19/2015 +4.0°C ALARM +0.7°C 7h 33min 05:36h ALARM +9.3°C 3h 4min 10:29h
ok 0min
20 12/18/2015 +5.4°C ALARM +0.4°C 4h 9min 00:00h ALARM +10.8°C 4h 54min 10:03h
ok 0min
21 12/17/2015 +4.6°C ALARM +1.1°C 3h 18min 18:54h ALARM +8.8°C 1h 36min 11:57h
ok 0min
22 12/16/2015 +5.3°C ALARM +1.9°C 3min 00:11h ALARM +9.0°C 1h 14min 11:43h
ok 0min
23 12/15/2015 +0.5°C ALARM -2.8°C 14h 59min 00:00h ok +5.1°C 0min
ok 0min
24 12/14/2015 -1.2°C ALARM -4.1°C 20h 57min 00:01h ok +4.1°C 0min
ok 0min
25 12/13/2015 -2.1°C ALARM -5.7°C 21h 53min 00:00h ok +3.1°C 0min
ok 0min
26 12/12/2015 +0.3°C ALARM -4.5°C 19h 1min 00:00h ok +5.1°C 0min
ok 0min
27 12/11/2015 -0.5°C ALARM -1.7°C 5h 34min 18:27h ok +1.4°C 0min
ALARM 18h 26min 00:00h
28 12/10/2015 +26.6°C ok +25.3°C 0min ALARM +27.5°C 2h 20min 13:42h
ALARM 8h 16:16h
Page 1/2
Logging interval: 5min
Measurement interval:1) 1min (fixed)
Lower alarm limit: Below +2.0°C for 1min
Upper alarm limit: Above +8.0°C for 1min
Activation date: 12/10/2015 13:40h
Date and time of report creation: 01/06/2016 20:37h
Identification number: 510500000006
PDF document of the Fridge-tag® 2 L
No. Date
(MM/dd/yyyy)
Events2) Average
temp.
Status
Lower alarm limit
Min.
temp.
Cumulative
daily time
below the limit
Alarm
trigger
time
Status
Upper alarm limit
Max.
temp.
Cumulative
daily time
above the limit
Alarm
trigger
time
Status
Ext. sensor connection error
Duration Alarm
trigger
time
Signature / notes
Action taken
1) Sampling and data analysis every minute
2) t = time / date changed, a = alarm configuration changed, hh:mm = status checked
Date and place: ____________________________ Signature: ____________________________
1 Today +1.8°C ALARM! -1.0°C 11h 4min 00:00h In progress +5.8°C 0min In progress 0min
2 01/05/2016 +1.5°C ALARM! -0.8°C 17h 29min 00:00h ok +5.7°C 0min ok 0min
3 01/04/2016 +1.5°C ALARM! -1.0°C 15h 1min 00:26h ok +4.5°C 0min ok 0min
4 01/03/2016 +2.0°C ALARM! -0.1°C 16h 9min 00:00h ok +6.4°C 0min ok 0min
5 01/02/2016 +1.7°C ALARM! -1.1°C 14h 54min 00:00h ok +7.5°C 0min ok 0min
6 01/01/2016 +2.3°C ALARM! -0.7°C 9h 35min 06:19h ok +5.5°C 0min ok 0min
7 12/31/2015 +0.9°C ALARM! -5.3°C 9h 24min 00:00h ok +5.3°C 0min ok 0min
8 12/30/2015 -1.7°C ALARM! -5.1°C 22h 46min 00:01h ok +2.5°C 0min ok 0min
9 12/29/2015 +0.9°C ALARM! -4.2°C 13h 22min 00:00h ALARM! +8.5°C 14min 13:48h ok 0min
10 12/28/2015 -0.3°C ALARM! -3.4°C 20h 1min 00:00h ok +6.0°C 0min ok 0min
11 12/27/2015 +0.0°C ALARM! -2.9°C 19h 42min 00:00h ok +5.9°C 0min ok 0min
12 12/26/2015 +0.0°C ALARM! -2.2°C 19h 47min 00:00h ok +6.4°C 0min ok 0min
13 12/25/2015 +2.3°C ALARM! -0.5°C 13h 19min 02:28h ALARM! +8.3°C 24min 12:51h ok 0min
14 12/24/2015 +2.4°C ALARM! -1.2°C 11h 14min 00:00h ALARM! +8.6°C 30min 10:59h ok 0min
15 12/23/2015 +3.3°C ALARM! -1.3°C 10h 34min 00:00h ALARM! +11.0°C 2h 55min 12:05h ok 0min
16 12/22/2015 a,19:35 +3.3°C ALARM -0.5°C 7h 25min 06:37h ALARM +8.2°C 13min 12:53h ok 0min
17 12/21/2015 +5.0°C ALARM +1.7°C 38min 22:41h ALARM +8.3°C 32min 09:30h ok 0min
18 12/20/2015 +3.1°C ALARM +0.3°C 10h 32min 00:00h ALARM +10.2°C 2h 38min 11:27h ok 0min
19 12/19/2015 +4.0°C ALARM +0.7°C 7h 33min 05:36h ALARM +9.3°C 3h 4min 10:29h ok 0min
20 12/18/2015 +5.4°C ALARM +0.4°C 4h 9min 00:00h ALARM +10.8°C 4h 54min 10:03h ok 0min
21 12/17/2015 +4.6°C ALARM +1.1°C 3h 18min 18:54h ALARM +8.8°C 1h 36min 11:57h ok 0min
22 12/16/2015 +5.3°C ALARM +1.9°C 3min 00:11h ALARM +9.0°C 1h 14min 11:43h ok 0min
23 12/15/2015 +0.5°C ALARM -2.8°C 14h 59min 00:00h ok +5.1°C 0min ok 0min
24 12/14/2015 -1.2°C ALARM -4.1°C 20h 57min 00:01h ok +4.1°C 0min ok 0min
25 12/13/2015 -2.1°C ALARM -5.7°C 21h 53min 00:00h ok +3.1°C 0min ok 0min
26 12/12/2015 +0.3°C ALARM -4.5°C 19h 1min 00:00h ok +5.1°C 0min ok 0min
27 12/11/2015 -0.5°C ALARM -1.7°C 5h 34min 18:27h ok +1.4°C 0min ALARM 18h 26min 00:00h
28 12/10/2015 +26.6°C ok +25.3°C 0min ALARM +27.5°C 2h 20min 13:42h ALARM 8h 16:16h
Page 1/2
Logging interval: 5min
Measurement interval:1) 1min (fixed)
Lower alarm limit: Below +2.0°C for 1min
Upper alarm limit: Above +8.0°C for 1min
Activation date: 12/10/2015 13:40h
Date and time of report creation: 01/06/2016 20:37h
Identification number: 510500000006
PDF document of the Fridge-tag® 2 L
No. Date
(MM/dd/yyyy)
Events2) Average
temp.
Status
Lower alarm limit
Min.
temp.
Cumulative
daily time
below the limit
Alarm
trigger
time
Status
Upper alarm limit
Max.
temp.
Cumulative
daily time
above the limit
Alarm
trigger
time
Status
Ext. sensor connection error
Duration Alarm
trigger
time
Signature / notes
Action taken
1) Sampling and data analysis every minute
2) t = time / date changed, a = alarm configuration changed, hh:mm = status checked
Date and place: ____________________________ Signature: ____________________________
Graph 1 Graph 2
Graph 3 Graph 4
Page 2/2
Date and time of report creation: 01/06/2016 20:37h
Identification number: 510500000006
PDF document of the Fridge-tag® 2 L
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
t
T
-40.0°C
-30.0°C
-20.0°C
-10.0°C
+0.0°C
+10.0°C
+20.0°C
+30.0°C
+40.0°C
+50.0°C
Alarm limits
12/10/2017- 12/16/201712/17/2017- 12/24/2017
12/25/2017- 01/01/2018 01/02/2018 - 01/09/2018
12/16/2017
00:00
12/145/2017
00:00
12/10/2017
00:00
12/13/2017
00:00
12/12/2017
00:00
12/11/2017
00:00
12/10/2017
00:00
12/24/2017
00:00
12/23/2017
00:00
12/22/2017
00:00
12/21/2017
00:00
12/20/2017
00:00
12/19/2017
00:00
12/18/2017
00:00
12/17/2017
00:00
01/01/2018
00:00
01/31/2017
00:00
12/30/2017
00:00
12/29/2017
00:00
12/28/2017
00:00
12/27/2017
00:00
12/26/2017
00:00
12/25/2017
00:00
01/09/2018
00:00
01/08/2018
00:00
01/07/2018
00:00
01/06/2018
00:00
01/05/2018
00:00
01/04/2018
00:00
01/03/2018
00:00
01/02/2018
00:00
Other manuals for Fridge-tag 2 L
4
Table of contents
Other berlinger Accessories manuals
Popular Accessories manuals by other brands

Dometic
Dometic Cabana Lightweight RV Dome Awning Installation and operation instructions

Spektrum
Spektrum SPMA9575 manual

ETC
ETC echoflex OWS-IR-UW-120/277 installation guide

Kasanova
Kasanova MAS022075 instruction manual

ROSE DISPLAYS
ROSE DISPLAYS ULTRAFRAME WITH SLATWALL manual

Carrier
Carrier Omnizone 50XCW06-24 Installation, Start-Up and Service Instructions

Velux
Velux ACTIVE with NETATMO installation instructions

Lunt Solar Systems
Lunt Solar Systems Ca-K manual

CLEARSCAN
CLEARSCAN CWK-CS-1020 Operation manual

Superfly
Superfly SUPERX8 user manual

Honeywell Home
Honeywell Home RDWL915W2000 Installation and operation guide

Datexx
Datexx UltraBattery BT-2200 user manual