6
Installingadualfuelrangecooker
RatingofServices
Theratingplateisvisibleattherearofthecookerandacopyisalsoattachedtothefrontofthe
manual.Beforeconnectingthecooker,checkthattherequirementsontheratingplatecorrespond
withthoseoftheelectricalsystemandgassupply(whereapplicable).Ensurethattheelectrical
systemandisolatingswitcheshaveasuitablecapacitytocarrythemaximumpowerasindicatedon
theratingplate.
Ventilation
Yourapplianceisnotconnectedtoacombustionproductsevacuationdevice.Theroominwhichitis
tobeinstalledmusthaveanairsupplyinaccordancewithBS5440(latestedition).Theroommust
haveanopeningwindoworequivalent,andsomeroomsmayrequireapermanentventinadditionto
theopeningwindow.Generalguidelines:Thecookermustnotbeinstalledinabedsitroomof20m³
orless.Ifthecookerisinstalledinaroomwithavolumeoflessthan5m³,thenaventwithan
effectiveareaof100cm³isrequired.Ifitisinstalledinaroomwithavolumeofbetween5m³and
10m³,thenanairventwithaneffectivearea50cm³isnecessary.Ifthereareotherfuelburning
appliancesintheroom,pleaseconsultBS5440(latestedition)forguidance.
Gasconnection
GasconnectiontothehobshouldbemadebyflexibleconnectingreinforcedtubecompliantwithBS
669‐1.A½”flexiblehosewithalowprofileselfsealingbayonetconnectorisrecommended.A½”BSP
socketissuppliedwiththecookersothattheflexibletubecanbeconnectedtothecookergasinlet.
Duetotheweightofthecookerastabilitybracketorrestrainingchainisrequired(BS6172‐2010).
Ensurethatthecorrectgastypeandpressureisavailable,andthatthesupplyissoundbeforegoing
ontotesttheburners.
Electricalconnection
Ensurethattheelectricitysupplyisswitchedoffbeforemakingtheconnection.Thisappliancemust
beearthed.
Connectiontotheelectricitysupplymustbemadethroughtheflexcablethatisalreadyattachedto
therearofthecooker.Theendofthecableistuckedintothecookerdrawer.
Connectiontothesupplymustbemadethroughfixedwiring.Itcannotbeconnectedtoanormal
domesticpowersocket.Adoublepoleswitchedcookerboxshouldbeusedwithcontactseparationof
atleast3mm.
Turnoneachhobzonetocheckthatallelementsarefunctioningcorrectly.Removeallpackagingand
combustibleitemsfromtheoven.Turnontheovenselectorswitchandthermostatknobtocheck
thattheovenisfunctionalonallmodes.
LPG
Theapplianceissuppliedforusewithnaturalgas.ConversiontoLPGmayonlybeundertakenbyaGas
Saferegisteredengineer.LPGjetsaresuppliedwitheverycooker.