10
BEFOREINSTALLATION
Thisapplianceshallonlybeinstalledbyan
authorizedprofessional.
Thisapplianceshallbeinstalledinaccordance
withthemanufacturer’sinstallationinstructions.
Thisappliancemustbeinstalledinaccordance
withthenorms&standardsofthecountrywhere
itwillbeinstalled.Theinstallationofthis
appliancemustconformtolocalcodesand
ordinances.Intheabsenceoflocalcodes,
InstallationsmustconformstoAmericanNational
Standards,NationalFuelGasCodeANSIZ223.1–
latestedition**orB149.1.
Theappliance,wheninstalled,mustbe
electricallygroundedinaccordancewithlocal
codesor,intheabsenceoflocalcodes,withthe
NationalElectricalCode,ANSI/NFPA70.
Iflocalcodespermit,aflexiblemetalappliance
connectionwiththenewAGAorCGAcertified
design,max.5feet(1,5m)long,½”I.D.is
recommendedforconnectingthisapplianceto
thegassupplyline.Donotbendordamagethe
flexibleconnectorwhenmovingtheappliance.
Thisappliancemustbeusedwiththepressure
regulatorprovided.Theregulatorshallbe
properlyinstalledinordertobeaccessiblewhen
theapplianceisinstalledinitsfinallocation.The
pressureregulatormustbesetforthetypeofgas
tobeused.Thepressureregulatorhas½”female
pipethread.Theappropriatefittingmustbe
determinedbasedonthesizeofyourgassupply
line,theflexiblemetalconnectorandtheshutoff
valve.
Theappliancemustbeisolatedfromthegas
supplypipingsystembyclosingitsindividual
manualshutoffvalveduringanypressuretesting
ofthegassupplypipingsystemattestpressures
equaltoorlessthan½psi(3.5kPa).
Allopeningandholesinthewallandfloor,back
andundertheapplianceshallbesealedbefore
installationoftheappliance.
Amanualvalveshallbeinstalledinanaccessible
locationinthegaslineexternaltotheappliance
forthepurposeofturningonorshuttingoffgas
totheappliance
WARNING!
Donotuseaerosolspraysinthevicinityofthis
appliancewhileitisinoperation
ROOMVENTILATION:Anexhaustfanmaybe
usedwiththeappliance;ineachcaseitshallbe
installedinconformitywiththeappropriate
nationalandlocalstandards.Exhausthood
operationmayaffectotherventedappliances;in
eachcaseitshallbeinstalledinconformitywith
theappropriatenationalandlocalstandards.
TYPEOFGAS
Thisapplianceisshippedfromthefactoryforuse
withnaturalgas.ForusewithpropaneLPgas
pleasefollowtheconversionprocedure
describedonpg.17.Astepbystepconversion
procedureisalsoincludedwitheachsetofLPgas
nozzles.
GASPRESSURE
Themaximuminletgassupplypressureincoming
tothegasappliancepressureregulatoris20’’
watercolumn(5kPa).
Theminimumgassupplypressureforchecking
theregulatorsettingshallbeatleast1“w.c.(249
Pa)abovetheinletspecifiedmanifoldpressureto
theappliance(thisoperatingpressureis4”w.c.
(1.00kPa)forNaturalGasand11”w.c.(2.75kPa
forLPGas).