10
ELECTRICALCONNECTION
Theapplianceshallbeconnectedtoasingle
phaseelectriclineratedat120/208Vacor
120/240Vacand60Hzfrequency.
Electricpowerrating:
‐120/208Vac:11800Wattor53Amax.
‐120/240Vac:12900Wattor56Amax.
Ovenheatingelementspowerrating:
‐Ovenbakeelement=2100Watt
‐Ovencircularelement=3300Watt
‐Ovenbroilelement=3400Watt
Inductionheatingelementspowerrating:
‐210inductionelement=2300–3700Watt
‐ 180inductionelement=1850–3000Watt
(nr.2zones)
‐145inductionelement=1400–2200Watt
Installasuitableelectricpowersupplyreceptacle
connectiontypeNEMA14‐50Rabletosupporta
loadofatleast50A(perline)accordingtolocal
coderequirements.Forfourorthreewirespower
supplyconnectionsystemseediagrambelow.
FOUR-WIRE CONN.RECEPTACLE NEMA 14-50R
THREE-WIRE CONN.RECEPTACLE NEMA 14-50R
Checkyourlocalcodeforwhichoftheoptions
belowshouldbeusedingroundingthe
receptaclepowersupplyconnections.
OPTION 1 – FOUR Wires connection:
‐ ConnecttheL1receptacleterminaltothe
incomingBLACKelectricalsupplywire(L1‐hot
wire)
‐ ConnecttheL2receptacleterminaltothe
incomingREDelectricalsupplywire(L2‐hot
wire)
‐ ConnecttheNEUTRALreceptacleterminalto
theincomingNEUTRAL(WHITE)electrical
supplywire
‐ ConnecttheGROUNDreceptacleterminalto
theincomingGROUND(GREEN)electrical
supplywire
OPTION2‐THREE‐Wiresconnection:
‐ ConnecttheL1receptacleterminaltothe
incomingBLACKelectricalsupplywire(L1‐hot
wire)
‐ ConnecttheL2receptacleterminaltothe
incomingREDelectricalsupplywire(L2‐hot
wire)
‐ ConnecttheNEUTRALwiththeGROUND
receptacleterminaltotheincomingNEUTRAL
(WHITE)electricalsupplywire
DONOTUSEEXTENSIONCORDSWITHTHIS
APPLIANCEASITMAYRESULTINFIRE,ELECTRIC
SHOCKOROTHERtypeofPERSONALINJURY.
Theapplianceisequippedatthefactorywithan
electricsupplycordset4wirestypewithring
terminals(L1,L2,N,Ground)suitableforrange
useUL/CSAlistedtypeSRDT/DRT2x6AWG(L1,
L2)+2x8AWG(N,G)rated300V,50Awithfused
plugtypeNEMA14‐50P;cablelength1,5m.;in
casethesupplycordsetmustbereplaced,itshall
bereplacedwithanidenticalsethavingthesame
technicalspecsandfollowingcarefullythe
instructionsanddiagramsbelow:
1) Disconnectappliancefromelectricalpower
supplyreceptacle
2) Slideouttheappliancefrominstallationplace
toaccesstobackenclosurepanel
3) Removebackenclosurepanelbyremoving
the6screwsasshownbelow.
4) Loosestrainreliefbyunscrewingthetwo
strainrelief'sscrewsasindiagram.