Besantek BST-DL116 User manual

BST-DL114 / BST-DL115/BST-DL116/BST-DL117
Wireless Monitor Temperature Humidity
Data Logger
Manual
V1.0
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

CONTENTS
Chapter I product introduction ....................................................................1
1.1 Product Features....................................................................................................................................1
1.2 Range of Application...............................................................................................................................2
1.3 Performance parameters........................................................................................................................2
1.4 BST-WDL07 wireless basE station appearance diagram ......................................................................2
1.5 Wireless data logger with LCD display...................................................................................................3
1.6 Wireless data logger LCD Symbol Description ......................................................................................3
1.7 Install battery .........................................................................................................................................4
Chapter II Software Usage Guide.................................................................5
2.1 Install software........................................................................................................................................5
2.2 Set RJ45 module in BST-WDL07 wireless basic station.......................................................................5
2.3 BSTServer software ...............................................................................................................................6
2.3.1 Open and running software..........................................................................................................6
2.3.2 System Settings...........................................................................................................................7
2.3.3 Communication Settings..............................................................................................................7
2.3.4 User Managemen ........................................................................................................................8
2.3.5 Partition managemen...................................................................................................................8
2.3.6 Device managemen.....................................................................................................................9
2.3.7 Real-time curve button...............................................................................................................10
2.3.8 Text display button ..................................................................................................................... 11
2.3.9 Previous area / next area button................................................................................................ 11
2.3.10 Monitor list button..................................................................................................................... 11
2.4 View and export the data to be uploaded............................................................................................. 11
Chapter III Precaution.................................................................................14
3.1 Precaution.............................................................................................................................................14
3.2 FAQ.......................................................................................................................................................14

1
Chapter I Product Introducon
Besantek wireless temperature and humidity recorder design of a high-speed, intelligent temperature and
humidity recorder. The instrument uses wireless data transmission method to collect and record temperature an
d
humidity data. It comes with record memory, can store 8192 sets of data, can realize remote real-me monitoring
of warehouses, laboratories, refrigerators, cold storage and other environments, using 2.4G wireless network to
send data without wiring, simple operaon, reliable performance.
1.1 Product Features
(1)Zigbee to RJ45 wireless relay technical parameters
Wireless transmission rate: 115200bps.
The number of wireless recorder can be Max connected to 32 units.
Support frequency band number: 15 frequency bands
Wireless Interface: Zigbee ad hoc network, automacally find the best link to transmit data
built-in RJ45 interface, will receive the wireless data from LAN and transmit data to the server
Can be used as relay / gateway at the same me, used for receiving wireless s ignal sent by wireless
temperature and humidity recorder.
Power : 12V DC adapter
(2) Wireless recorder technical parameters
Wireless transmission rate: 115200bps.
LCD resoluon: temperature 0.1 ℃/ humidity 0.1% RH.
Sound and light alarm (LED lights + buzzer). More than any channel set the upper and lower limits, then
automacally alarm.
Switzerland imported integrated temperature and humidity sensor.
recording interval: 2s-24h
Support connue transferring from breakpoint funcon.
Wireless transmission rate: 115200bps, the maximum transmission distance: 50-500 meters (test data in
empty without blocking environment).
Use Zigbee 2.4G wireless network

2
1.2 Range of Application
Widely used in agricultural research, food, medicine, warehouses, cold storage, refrigerator, computer room,
chemical industry, meteorology, environmental protecon, electronics, laboratory and other fields of temperature
and humidity monitoring.
1.3 Performance parameters
1.4 BST-WDL07 wireless base station appearance diagram
Model Measurement
Accuracy
Measurement
Range
Probe Type
(T:Temperatur; H:Humidity)
Capacity of
Records
BST-DL114 ±0.5℃/±3%RH
-20~70℃
0
~
100%RH
T&H
8,192
BST-DL115 ±0.5℃/±3%RH
-40~85℃
0~100%RH T&H External
BST-DL116
±0.5℃-40~85℃Double T External
BST-DL117
±2℃-100~200℃Thermocouple Type K

3
BST-WDL07
Ethernet interface(RJ45)
12V DC power interface
Antenna
1.5 wireless data logger with LCD display
LCD display Wall-mounted back cover
LCD indicator Back cover screw-fixed posion
USB port & DC power Jack (9-12V)
1.6 LCD Symbol Description
Battery symbol DC power symbol
Signal symbol Auto logging symbol
Wireless symbol Selectable ℃/℉symbol
Temperature display area Humidity symbol
Humidity display area

4
1
.7 Install battery
Loosen the back cover screw with the screwdriver, and install 4*1.5V AA batteries according to th
e
d
irecon of the battery.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

5
Chapter II Soware Usage Guide
2.1 Install software
(1)Put Monitor soware CD-ROM into the drive, copy BSTServer soware to the computer hard disk.
(note: do not install in C disk, prevent the operang system crash data loss, is beneficial to protect
data.)
(2)open the folder and find the BSTServer
2.2 Set RJ45 module in BST-WDL07 wireless basic station
BST-WDL07 connect 12V power supply and RJ45 network port, open Lanconfig in the folder, pop-up interface
as shown below:
(1) Click [Search ] to search the device, the right half of the interface will display the name and IP address of
wireless basic staon that has been connected to LAN. Note: The LanConfig soware uses the UDP
broadcast protocol to search the module, ensuring that the firewall or anvirus soware does not block
the software.
(2) select the serial number of the selected BST-WDL07 wireless base staon and double-click to obtain the
property.
(3) Instrument Name: can be modified according to actual needs.(Note: the factory seng is the instrument
serial number)
(4) Work Model: : set to TCP Client mode.

6
(5) Baud Rate: set to 115200
(6) DHCP Mode Relay Service: select Disable offstate. It is recommended to choose a fixed IP address to ensure
network stability.
(7) IP Address/Net Make/IP Gateway: modify IP informaon, the Gateway should be consistent with the current
LAN, and the IP Address is BST-WDL07 wireless base staon IP address(note: this IP should not conflict with
other instrument IP)
(8) Server IP: This IP address is the same as the fixed IP address of the controlling computer.
(9) Server Port: The default is 4588 Same as the TCP listening port of ToMonitor soware
(
10)Click [Synchronize] to submit changes, a "Change Device Informaon Success" dialog box will pop up, and
click to confirm finally.
2.3 ToMonitor software
2.3.1 Open and running soware
The instrument is powered on, the BST-WDL07 is powered on and connected to the Ethernet.
Double click , Click [Login] button to enter the login interface as shown below, the inial user
name and password are "admin" (not case-sensive).
Aer successful login to ToMonitor soware, the toolbar and menu keys are all acvated, as shown below:

7
2.3.2 System Setngs
Click , The following dialog box will pop up:
(1) custom soware name: customize the soware tle name according to actual requirements.
(2) Set the window arrangement number.
(3) record keeping interval
2.3.3 Communicaon Setngs
Click , The following dialog box will pop up:
Wireless Server Port Setngs:
a. TCP listening port (RJ45): 4588 (BST-WDL07 wireless base staon to set this port)
(1)
(2)
(3)

8
b. USB Port (USB): port selecon COM1 ~ COM9(RS485 base staon to set this port, the Port number is
consistent with the USB Port number that connects devices)
2.3.4 User Management
Click , Pop-up the following dialog box, add the user name as needed:
2.3.5 Paron management
Click ,Pop-up the following dialog box, add parons as needed:
a
b

9
Note: After add a new recorder must be divided into regions, otherwise the window page will not display the
new recorder monitoring
2.3.6 Device management
Click , The following dialog box will pop up:
Type of instrument

10
(1) [Basic Setngs] Logger parameter setngs
Name: can be named according to the actual situaon, the name of each instrument can not be repeated.
Serial Number: Enter the 10-digit serial number posted on the instrument.
Instrument Type: Set to "Wireless Instrument".
Sampling interval (minutes): The refresh interval of instrument data can be set according to the actual situaon.
The number of sensors: select a single channel shows only 1 (only display the data of a channel, single
temperature recorder can select this), select dual channel display 2 (display two channels of data, temperatur
e
and humidity recorder can select this ).
(2)[Sensor I]
High : the upper limit can be set. When the set value is exceeded, the monitoring value is displayed in the red font
.
Please set the alarm mode to send the alarm informaon according to the actual demand.
Low : the lower limit can be set. When the set value is exceeded, the monitoring value is displayed in red font.
Please set the alarm mode to send the alarm informaon according to the actual demand.
Type: temperature/humidity (please choose according to the type of purchase recorder).
(3)[Sensor II]
High / low : The upper limit and lower limit can be set according to the actual situaon. When the setng value is
exceeded, the monitoring value will be displayed in red font, meanw hile, the alarm informaon will be sent
according to the setng alarm mode.
Type: temperature / humidity
Sound & Light Alarming: Optional working hours are off or open all the me.
Add button funcon: First, select one of the recorder in the dialog box, the properes displayed, enter a new
name and serial number, other parameters set according to the actual situaon, and then click to increase.
Apply button funcon: First, select one of the recorder in the dialog box, set the relevant parameters according t
o
the actual situaon, click the Modify button will pop up to modify the success dialog box, and then click OK.
Delete button funcon: First, select one of the recorder in the dialog box, click the delete button will pop up to
delete the success dialog box, and then click OK.
Exit button: Click the Exit button to exit the Device Management dialog box.
2.3.7 Real-me curve button
Click , The window is displayed as a curve, as shown below:

11
2.3.8 Text display button
Click , The window is displayed as a text number, as shown below:
2.3.9 Previous area / next area button
Click , can switch the window page to view monitor data, the keyboard up and down leand right
buttons can also be switched.
2.3.10 Monitor list button
Click , Show or hide the paron list
2.4 View and export the data to be uploaded
(1)Click BSTClient in BESANTEK software folder and open the software, as shown below:

12
(Note: When ToClient is opened, it is used when ToMonitor is open, otherwise, it will prompt to connect to th
e
server failed and can not view the data)
(2)Login system
(note: the port number is the number of [LAN] add 1, the number of [LAN] shown under ToMonitor, user nam
e
and password are admin)
(3)Click [Query] icon, the following dialog box will pop up. To select the instrument to query, select the
time period to be queried, click [Start Search]
Click connecon
Select instrument
Start Search
Select me period

13
(4)The following dialog box will pop up to check the corresponding data analysis diagram.
(5)Click [ DATALIST ] icon, the following dialog box will pop up and view the real-me data.
(6)Click [PDF] to export the query data to PDF file, and click [BMP] to export the analysis diagram t
o
BMP image file.
Click to view the data

14
Chapter III Precauons
3.1 Precauons
The data logger waterproof grade is IP34, if has water on the case, do not connect USB, to prevent th
e
electronic circuit short circuit under the influence of water. Short circuit may cause damage to th
e
instrument.
The data logger uses ABS fireproof plasc shell, to prevent the corrosion of acid and alkali and othe
r
chemicals for shell.
If it fails, it must be repaired by an authorized professional. Do not repair or modify it by yourself.
The device configured 4*1.5V lithium battery, it can’t be charged and don’t allow short circuit,
otherwise it may be dangerous. Waste battery should be properly handled to protect the environment.
3.2 FAQ
LCD display dim
Cause: The battery is low or the ambient temperature is too low or too high.
Soluon: replace the battery. If it is caused by ambient temperature, please take out the recorde
r
immediately and avoid damage to the recorder.
LOG symbols disappear
Cause: When the battery is low, there will not be enough power to maintain the recording funcon.
Soluon: replace the battery.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
This manual suits for next models
3
Table of contents
Other Besantek Data Logger manuals
Popular Data Logger manuals by other brands

Drew Technologies
Drew Technologies DashDAQ Series II instruction manual

Skipper
Skipper EML224 Compact Operation and installation manual

MadgeTech
MadgeTech Titan S8 Product user guide

Keller
Keller DCX Series operating instructions

Keithley
Keithley Integra 27 Series quick start guide

Xylem
Xylem ebro EBI 10 Series manual