Bewator Bewacard BC610 User manual

Bewacard BC610
Installation and User manual
GB

Copyright © January 1998 Bewator AB, Solna, Sweden.
Material from the BC610 Technical manual may only be copied with the
consent in writing of Bewator. Bewator reserves the right to alter both the
content of the manual and the design of the product.
Document no: BC6100203-GB
Text and layout: WM-data Education AB, Sweden.
Address (Sweden):
Bewator AB
Box 1275
S-171 24 SOLNA, Sweden
Visiting address: Englundavägen 7
Phone: +46 8 627 00 85 (Customer Service)
+46 8 627 00 95 (Reception)
Fax: +46 8 627 00 96
Website: www.bewator.se
E-mail: support@bewator.se
Bewator AB are parts of Bewator Group, which develops and markets a
complete security product range that includes access control, alarm and
time & attendance. Sales, installation and servicing are handled by a national
dealer network.
Actions (such as unauthorised manipulation, copying etc.), must not be taken
with the software contained in the products and systems. Such actions are
regarded as copyright violation and may result in imprisonment or fines and
may likewise lead to an obligation to pay damages and compensation for
using the software.

BC610 Installation and User manual 3
Contents
THIS IS THE BC610......................................................... 4
How does the card reader work?...................................4
Timing security levels......................................................4
Duress...............................................................................5
INSTALLING THE CARD READER ................................ 6
HOW TO SELECT CONNECTING CABLES .................. 7
INSTALLATION ............................................................... 8
LAYOUT OF THE KEYPAD........................................... 10
PROGRAMMING ........................................................... 11
Buzzer and LEDs...........................................................11
Set password..................................................................12
Set the card reader to programming mode.................12
Log on a card (with a card)..........................................13
Log on a card (without the card) .................................13
Log on a series of cards.................................................14
Cancel card (with card) ................................................14
Cancel card (without card)...........................................15
Program/change/erase the common code....................15
Change the Door Opening time....................................16
Buzzer on/off..................................................................16
Erase the memory and reset the default settings........17
Change password ..........................................................18
Card parameters ...........................................................19
Door operation on change of toggle enable.................20
PROGRAMMING OVERVIEW....................................... 21
NAME CHART................................................................ 22
DAILY USE..................................................................... 23
Entrance.........................................................................23
The toggle function........................................................23
Choose/change PIN code...............................................24
Duress.............................................................................24
TROUBLESHOOTING................................................... 25
TECHNICAL INFORMATION ........................................ 26

4 BC610 Installation and User manual
This is the BC610
BC610 is a 500 card capacity compact card reader designed
for one door. All programming is done from the keypad.
How does the card reader work?
BC610 can be used in different ways depending on the
security requirements. If no external equipment (time clocks,
push buttons etc.) is connected, card and common code can be
used 24 hours a day. If no common code is programmed the
card reader will only accept cards.
Timing security levels
Using external time clocks, a number of security levels can be
set up. The security level determines what action is required
to open the door. The following security levels exist:
•Unlocked door.
•Common code. A four-digit code (common to all users) is
required to open the door. The common code is
programmed by the person responsible for the card reader.
•Card. The visitor must swipe his card to open the door.
•Card + PIN. The visitor must swipe his card and enter a
personal code to open the door. The card holder can
choose/change his or her personal code on the keypad.
•Toggle function. Used together with current security level,
i.e. Card, Common code or Card + PIN. When the
card/code is swiped/entered the first time the door is
opened and remains unlocked until the card/code is
swiped/entered the next time.
•Card reader disconnected. The card reader is completely
disconnected. Only exit request works.

BC610 Installation and User manual 5
Examples of timing security levels,
During office hours, when there are people in the premises,
the security level may not need to be so high: Unlocked door
or Common code are probably suitable levels.
During lunch time, the level may be raised to Card.
The remaining time, i.e. evenings, nights and weekends, Card
+ PIN is a suitable security level.
The Toggle function can be used in premises where a person
is responsible during certain hours, e.g. a class-room or a
loading bay door.
In a class-room, the teacher can open the door, which remains
open until he or she locks the door. The pupils may come in
and out without having cards or common code.
Duress
BC610 is equipped with a duress output. If a visitor is forced
to open the door under threat, he or she may enter a special
code that activates an alarm.
Note! Duress is only applicable during the Card + PIN
security level.

6 BC610 Installation and User manual
Installing the card reader
Install the card reader at a height of 120–140 cm (from the
floor to the bottom edge of the card reader). To cater for
disabled persons, a suitable height is approximately 95 cm.
To install the card reader:
1Open the card reader with the key supplied. The lock is
located on the underside of the reader.
2Fasten the back plate against the wall, using three screws
according to the illustration below. Seal the screw and
cable holes with sealant if the unit is externally mounted.
3Make sure the back plate is earthed. Use a separate cable
to the earthing point. Make sure the front and back plate
are connected with the internal strap.
4Fit the front and check that the card reader is securely
fastened.

BC610 Installation and User manual 7
How to select connecting cables
It is important to use cables with the correct conductor gauge,
to keep the voltage drop in the cables as low as possible.
•12 volt supplies. A 12 V electric locking device generally
needs at least 11 V to work properly, so the voltage at the
card reader should never be less than 11 V.
•24 volt supplies. A 24 V electric locking device generally
needs at least 21 V to work properly, so the voltage at the
card reader should never be less than 21 V.
The recommended gauge (cross-sectional area) of the
conductor depends on the distance between the power supply
and the card reader, and on the load at the card reader.
The table below is for a Bewacard 610 with an electric
release. The total load is 300 mA at 24 V or 600 mA at 12 V.
24 V Supply 12 V Supply
Cable
length
(metres)
Min conductor Min conductor
area
(mm2)dia
(mm) area
(mm2)dia
(mm)
0-50 0.17 0.46 0.51 0.80
51-100 0.34 0.65 1.02 1.14
101-150 0.51 0.80 1.53 1.40
151-200 0.68 0.93 2.04 1.61
201-250 0.85 1.04 2.55 1.80
251-300 1.02 1.14 3.06 1.95

8 BC610 Installation and User manual
Installation
1 2 3 4 5 6 7
DURESS
0V
CODE
PIN
TOGGLE
READER
INHIBIT
EXIT
BUTTON
LOCK
12-30V
0V
BACK
LIGHT
SW1
15 14
TAMPER
TAMPER
1
2
3 4
5
67
8
9
10
11
8 9 10 11 12 13
+

BC610 Installation and User manual 9
Installation continued
The numbers below refer to the numbers on the wiring diagram.
1Electric locking device. Dashed line shows connection to
locks with fail unlocked operation.
2Power in, terminal block nos. 1 and 2.
3Exit Request button. To operate short terminal nos. 6 and 9.
Optionally, a time-clock can be connected to control a door
that should be permanently open.
4Input for reader inhibit. To operate short terminal nos. 7 and
9. The red LED on the fascia will be lit.
5Duress output. Used for activating an external alarm. Use an
E7 relay. Connect between terminal nos. 8 and + (1).
6Remove the jumper if back lighting is not required.
7Control input for Common code. Terminal nos. 10 and 13
open: Common code enabled. Terminal nos. 10 and 13 linked:
Common code disabled.
8Control input of Card and Card + PIN security levels.
Terminal nos. 11 and 13 open: Card. Terminal nos. 11 and 13
linked: Card + PIN.
9Control input for Toggle function. Link terminal nos. 12 and
13 to activate the toggle function.
10 The SW1 push button. Used to erase the memory and to set a
new password.
11 Tamper switch. Normally closed when the housing is closed.

10 BC610 Installation and User manual
Layout of the keypad
Diagram of the LEDs and push-buttons on the BC610 keypad.
123
456
789
A0B
All LEDs are flashing in programming mode. The LEDs also
have other indications explained in full later.
Red LED.
Indicates errors. E.g.
cancellation of card
following 3 incorrect
PIN codes.
Yellow LED.
Indicates keypresses. Lit when PIN
code should be entered.
Green LED.
Lit when the door is unlocked.
E.g. Accepted card transaction
A.
Initiates program-
ming sequence,
e.g A01 to log on
cards. Also used
when choosing
PIN code
(see page 24).
B.
Press B + the 6-digit password
whenever you want to program
BC610. Press B to leave
programming mode.

BC610 Installation and User manual 11
Programming
In the sections below are the instructions on how to program
BC610. To be able to program the card reader you have to set
the card reader to programming mode. This is done by
entering a six-digit code (see the next page).
Buzzer and LEDs
During programming you will be guided by the buzzer and the
LEDs.
In this manual the LEDs are illustrated in the following way:
!= Off "= Lit #= Flashes
In programming mode before a function is chosen: All three
LEDs are flashing. ###
During programming: The LEDs are lit or off depending on
the function being programmed.
Correct programming: Confirmed by a rising signal
consisting of two quick beeps.
Faulty programming: Confirmed by a falling signal
consisting of one long and one short beep.
Note! If, having entered programming mode, no key is
pressed within 20 seconds, the unit will leave programming
mode.

12 BC610 Installation and User manual
Set password
The first thing to do before starting to programme the card
reader is to set a password.
1Open the card reader with the key supplied. The lock is
located on the underside of the card reader.
2Press the SW1 button (see wiring diagram on page 8).
3Enter the desired 6-digit password on the card reader’s
keypad.
The password is now set.
Set the card reader to programming mode
To program a function, the card reader has to be in
programming mode. Proceed as follows:
1Press B. !!#
2Enter the 6-digit password. ###
The card reader is now in programming mode.
Note! If the wrong password is entered two times in
succession, the card reader is blocked from further attempts
for 10 seconds. From then on the card reader is blocked for 40
seconds each time two incorrect passwords are entered.

BC610 Installation and User manual 13
Log on a card (with a card)
Using this function, the cards to be used are programmed in to
the card reader.
1Set the card reader to programming mode.
2Press A01. !""
3Swipe the card. If the card is already in the reader, the
”faulty programming” signal is heard.
4Swipe the next card, as required.
5When finished, press B to go back to programming
mode.
6Press B one more time to leave programming mode.
Log on a card (without the card)
Using this function cards can be programmed by keying in the
card number.
1Set the card reader to programming mode.
2Press A03. !""
3Enter the card number on the keypad. If the card is
already logged on, the ”faulty programming” signal is
heard.
4Key in the next card, as required.
5When finished, press B to go back to programming
mode.
6Press B one more time to leave programming mode.

14 BC610 Installation and User manual
Log on a series of cards
Using this function you can quickly log on a contiguous series
of cards.
1Set the card reader to programming mode.
2Press A04. !""
3Enter the card number of the first card in the series.
4Enter the card number of the last card in the series. The
red LED flashes as the cards are logged on.
5Press B to leave programming mode.
Cancel card (with card)
Using this function a card can be cancelled (with the card) so
that it cannot be used in the card reader.
1Set the card reader to programming mode.
2Press A14. "!!
3Swipe the card.
4Swipe the next card, as required.
5When finished, press B to go back to programming
mode.
6Press B one more time to leave programming mode.

BC610 Installation and User manual 15
Cancel card (without card)
Using this function cards can be cancelled using the card
number.
1Set the card reader to programming mode.
2Press A16. "!!
3Enter the card number. If the card is not logged on the
”faulty programming” signal is heard
4Cancel the next card, as required.
5When finished, press B to go back to programming
mode.
6Press B one more time to leave programming mode.
Program/change/erase the common code
This is how to program/change/erase a common code.
1Set the card reader to programming mode.
2Press A21. "!"
3Enter a four-digit common code. The existing code will
be over-written.
To erase the common code so that it does not work, enter
0000.
4Press B to leave programming mode.

16 BC610 Installation and User manual
Change the Door Opening time
The opening time determines for how long the lock should
remain open following a correct entrance. The default is 7
seconds. This is how to change the opening time, if required.
1Set the card reader to programming mode.
2Press A28. """
3Enter the desired opening time (between 01 and 99
seconds).
4Press B to leave programming mode.
Buzzer on/off
The default is that the buzzer is activated. If you do not want
the buzzer to beep on key presses or door opening, it can be
turned off. Note that even when the buzzer is off for normal
operation, it will continue to sound during programming.
1Set the card reader to programming mode.
2Press A65. ""!
3Press 0.
4Press B to leave programming mode.
To reactivate the buzzer, press 1 in step 3 instead.

BC610 Installation and User manual 17
Erase the memory and reset the default settings
When the card reader’s memory is erased, the default settings
are restored (see below).
1Set the card reader to programming mode.
2Open the card reader with the key supplied. The lock is
located on the underside of the card reader.
3Press the SW1 button (see the wiring diagram on page
8).
4Press 112186.
5Press 112186 one more time.
All previously logged on cards have now been erased. The
card reader reverts to the following settings:
•Password: 112233
•Common code: None
•Opening time: 7 seconds
•Toggle security level: 0
•Card parameters: Position 9-16, the last 8 positions if
fewer than 16 positions.

18 BC610 Installation and User manual
Change password
To change the password:
1Press B and enter the present password.
2Press A27. """
3Enter the new password. A warning tone is heard.
4Enter the new password again. The warning tone sounds
until all six digits have been entered.
5Press B to leave programming mode.
6Make a note of the new password.
Note! If you should forget the password can you set a new
password. Read the Set password section on page 12.

BC610 Installation and User manual 19
Card parameters
When BC610 is delivered, the card reader reads positions 9 to
16 on the card’s magnetic strip, or the last 8 positions if they
are fewer than 16. If you want to use your own cards and they
should be read differently, enter from which position on the
magnetic strip the reader should start reading and how many
digits should be read (max. 8).
Note! Previously logged on cards will not work if you change
the card parameters.
1Set the card reader to programming mode.
2Press A97. "!"
3Enter from which digit in the card number (01-40) the
digits should be read.
To reset this function to the default setting, press A at
this point.
4Enter the number of digits to be read (1-8).
5Press B to leave programming mode.

20 BC610 Installation and User manual
Door operation on change of toggle enable
The default setting is that if the door is unlocked when a
security level changes, the door will be locked immediately.
This is setting 0 of this function.
This function can be changed so that the door remains
unlocked when a security level changes. This is setting 1 of
the function.
To lock the door a valid transaction must be performed as
required during the new security level. (e.g. Card + PIN)
1Set the card reader to programming mode.
2Press A96. "!"
3Press 1 for setting 1.
Press 0 for setting 0 (this is the default setting).
4Press B to leave programming mode.