BFCMA Wood Burning & Multi Fuel Appliances Instruction sheet

Installation
Guidelines
www.bfcma.co.uk
for Wood Burning &
Multi Fuel Appliances

Adaptor
Twin wall flue
Vitreous enamel
or single wall
connecting flue pipe
Cover Band
Existing Masonry Chimney
Top outlet on stove
Adaptor
Inspection Bends
90˚Tee
135˚Tee
Inspection
Length
Tee Cap
Offset no greater
than 45˚
Flexible Liner
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Wood Burning & Multi Fuel Stoves
The stove should be connected
to the flue using vitreous enamel
or 1mm thick single wall
stainless steel pipe.
New System Chimney
Top outlet on stove
Rear outlet on stove
Connecting Flue Pipe

Vitreous Enamel or Single Wall
Connecting Flue Pipe
Top Clamp
This item is used in conjunction
with the top plate to secure the
liner at the top of the stack.
Top Plate
This item is used in conjunction
with the top clamp to support
the liner at the top of the stack.
Can also be used as a debris
plate above the appliance.
Debris Plate
Bottom Support
Bracket
Top Insert
Twin Wall Liner
15mm Angled Vent Tubes
Vitreous Enamel or
Connecting Flue Pipe
Adaptor to Flexible Liner
Different terminal options
available including clay
chimney pot as shown
or a range of stainless
steel terminals.
Inspection Length
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Wood Burning & Multi Fuel Stoves
Existing Chimneys
Relining an existing chimney
with twin wall flexible liner

Tapered Terminal
Adjustable Pipe
Slides inside pipe below.
Complete with locking
band. This component
is not load bearing.
Pipe
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Relining an existing chimney
with single wall liner.
Wood Burning & Multi Fuel Stoves
Existing Chimneys
If the 0.6mm thick liner has been tested
in accordance with BSEN1856 part 2
then it may be used. If not then 1mm
single wall liner must be used.

Internal Twin Wall
Stainless Steel Chimney
System for Stove
Stainless Steel Terminal
Flashing
Roof Support
Protective Wire Mesh
(required in loft space)
Support plate
Firestop plate
Combustible Shaft
Stove Pipe Connector
Connecting Flue Pipe
or Vitreous Enamel
Firestop Plate
Twin Wall Flue
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Wood Burning & Multi Fuel Stoves
New Chimneys

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Capping for
brick stack
Free Standing Stove in an Alcove
Support block
and adaptor
for connection
to stove
Corbel for
brick stack
Flue blocks
installed with
socket uppermost
Staggered joints
between casing
and flue block Outer casings
dry lined or
plastered
Chimney tray
and flashing
Structural timber
40mm from outside
of chimney or 200mm
from inside of flue liner
All joints sealed
with flue jointing
compound
Suitable
pre-stressed
lintels to support
chimney
Suitable
foundation
and hearth
Support block
and adaptor for
connection to
stove pipe
Stove recess
Firebrick
lining or
render finish
Stove Recess
Continue to build chimney
as show for freestanding
stove in alcove
Free standing stove with external
chimney with preformed stove entry kit
2 x casing
ties at maximum
intervals of
1.5 metres
Outer casing
with soot door
Flue pipe fitted
into access
casing at 45˚
Capping for
rendered stack
Lead flashing
Outer casing
rendered along
entire length of
external chimney
Suitable
foundation
and hearth
Sand/cement
flaunching
All joints sealed
with flue jointing
compound
Suitable
foundation
and hearth
Wood Burning & Multi Fuel Stoves
Clay Concrete & Pumice
- Chimney Systems

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Pumice
Chimney System
Suitable lintels to
support chimney stack
Support block and
adaptor for connection
to flue pipe
Glass fronted insert fire
Single wall
connecting flue
Concrete or
brick coping
Chimney tray required
High grade ceramic
liner jointed with high
temperature sealant
Corbel to support
external finish
(block or brick)
Expansion plate
Chimney block
400x400x 330mm
Fire chamber
600mm wide
formed with
concrete lintel
and hollow
blocks
675mm
1640mm
Holes to facilitate
reinforcement bars
where necessary
Standard gap of
40mm to be kept
between outer
surface of chimney
and structural timbers
Special size
concrete blocks
Timber frame wall
attached to chimney
with flexible timber
frame ties
Chimney Breast Bend Kit
Two Bend Kits are available. The Breast Bend Kit
allows the flue to be removed from 200 - 400mm
within the chimney breast. The Standard Bend Kit
allows the flue to be moved horizontally as desired
so long as it is supported in the traditional manner.
Standard chimney
blocks may be
inserted to
extend offset
Traditional support
required for standard
bend kit
Wood Burning & Multi Fuel Stoves
Clay Concrete & Pumice
- Chimney Systems
Ceramic
Chimney System
Chimney block
400x400x 330mm

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Concrete or brick coping
Chimney tray required
High grade ceramic
liner jointed with high
temperature sealant
Corbel to support external
finish (block or brick)
Expansion plate
Chimney block
Holes to facilitate
reinforcement bars
where necessary
Standard gap of 40mm
to be kept between outer
surface of chimney and
structural timbers
Support block
and adaptor for
connection to stove
Chimney secured to
masonry wall every
metre with expanded
metal ties
Suitable pre-stressed
lintels to support
chimney
Wood Burning & Multi Fuel Stoves
Clay Concrete & Pumice
- Chimney Systems
Ceramic
Chimney System
for Stoves

Insert Fire
Cast in situ slab
to support chimney
Support block and
adaptor for connection
to flue pipe
Glass fronted
insert fire
Free Standing Stove
Sand/cement flaunching
around flue liner or
chimney pot
Chimney tray
and flashing
Structural timber
40mm from outside
of chimney or 200mm
from inside of flue liner
Joints sealed with flue
joining compound
Standard flue liners
with socket uppermost
Voids filled with
suitable insulating
material
Support block and
adaptor for stove
connection
Cast in situ slab to
support chimney
Continue to build chimney
as in free standing stove
Suitable foundation
and hearth
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Suitable foundation
and hearth
Wood Burning & Multi Fuel Stoves
Clay Concrete & Pumice
- Liners

Open Fires
Clay Concrete & Pumice
- Liners
Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems
Pumice Liners
with Preformed
Wood Burning Firechest
Terminated with chimney pot
Sand/cement flaunching
Chimney tray
and flashing
Joints sealed with suitable
flue jointing compound
Standard flue liners with
socket uppermost
Voids filled with suitable
insulating material
Firebrick lining
Firechest
Suitable lintel

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Schiedel Chimney Systems except Standard Methodology for Clay, Concrete & Pumice Liners; courtesy of Wavin.
Suitable foundation
Open Fire using
Standard Firechest
Capping for rendered stack
Sand/cement flaunching
Seal joints
corbel to complete
brick stack
Inner flue blocks with
socket uppermost
Staggered joints
between casing
and flue block
Outer casings built
into inner leaf of
cavity wall
Outer gather
Standard firechest
Firechest
Staggered joints
between casings
and flue block
Firechest
complete
with damper
Firebrick lining
inside firechest
Built on suitable
foundation
Open Fires
Clay Concrete & Pumice
- Chimney Systems
Flue liners
jointed with
flue liner jointing
compound
Standard Methodology for
Clay, Concrete & Pumice Liners
Chimney stack
Void
Chimney
breast
Lightweight
insulating infill
Decorative
fireplace
surround
Superimposed
quarry tile hearth
Constructional hearth
Flue adaptor
Fireplace lintel
600 back section
Fireplace lintel
600 front section

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Exodraft
Wood Burning & Multi Fuel Appliances
Chimney Fan System

Installations show are by way of illustration only. Manufacturer's installation instructions should always be consulted before installation.
Drawings courtesy of Brewer Cowls
Examples of Terminals
Examples of Stainless Steel
Terminals, Birdguards &
Anti-Downdraught Terminals
Anti-Downdraught
fitted to Twin Wall System
(with or without mesh)
Birdguard
fitted to Twin Wall System
(with or without mesh)
Anti-Downdraught Pot Hanger
fitted to Twin Wall Flexible Liner
(with or without mesh)
Birdguard Pot Hanger
fitted to Twin Wall Flexible Liner
(with or without mesh)
Solid Fuel Anti-Downdraught
fitted to Chimney Pot
(with or without mesh)
Raincap
fitted to Chimney Pot
Pot Hanger
fitted to Twin Wall Flexible Liner
Birdguard
fitted to Chimney Pot

www.bfcma.co.uk
Mi-Flues
Spiro House, Cocker Avenue,
Poulton Business Park,
Poulton-Le-Fylde,
Lancashire,
FY6 8JU,
T: 01253 884 972
F: 01253 893 752
www.mi-flues.com
MMF
Flue House,
55 Woodburn Road,
Smethwick,
West Midlands,
B66 2PU,
T: 0121 555 6555
F: 0121 555 1606
www.fluepipes.com
Muelink & Grol B.V.
Postbus 509,
9700 AM Groningen - Holland,
Duinkeerkenstraat 27,
9723 BP Groningen - Holland,
T: +31 (0) 50 313 9944
F: +31 (0) 50 318 5423
www.muelink-grol.com
Pennine Systems
Crossley Works, Stockfield Mount,
Off Peel Street, Chadderton,
Oldham,
Lancashire,
OL9 9LR,
T: 0161 678 2998
F: 0161 678 2997
www.penninesystems.co.uk
Poujoulat (UK)
Unit 1, Quadrum Park,
Old Portsmouth Road,
Guildford,
Surrey,
GU3 1LU,
T: 01483 461700
F: 01483 533435
www.poujoulat.co.uk
W.T. Knowles & Sons
Ash Grove Pipe Works,
Elland,
West Yorkshire,
HX5 9JA,
T: 01422 372 833
F: 01422 370 900
www.wtknowles.co.uk
List of Members
Schiedel Chimney Systems
Crowther Estate, Washington,
Tyne & Wear,
NE38 0AQ
Schiedel Rite-Vent
T: 0191 4161150
F:0191 415 1263
Schiedel Isokern
T: 01202 861650
F: 01202 861632
W: www.schiedel.co.uk
SFL Flues & Chimneys
Pottington Business Park,
Barnstaple,
Devon,
EX31 1LZ,
T: 01271 326633
F: 01271 334303
www.sflchimneys.com
Simplefit
Central Crescent,
Marchwood Industrial Park,
Marchwood,
Southampton,
SO40 4BJ,
T: 023 8066 3210
F: 023 8066 3086
www.simplefit.co.uk
Specflue
8 Curzon Road,
Chilton Industrial Estate,
Sudbury,
Suffolk,
CO10 2XW,
T: 01787 880333
F: 01787 880555
www.specflue.com
Wavin
Hazlehead,
Crow Edge,
Sheffield,
South Yorkshire,
S36 4HG,
T: 0844 856 5152
F: 0870 443 8000
www.hepworthterracotta.co.uk
Brewer Metalcraft
Units C & D,
Ford Lane Industrial Estate,
Ford, Arundel,
West Sussex,
BN18 0DF,
T: 0745 676 0702
F: 0845 676 0703
E: sales@brewercowls.co.uk
www.brewercowls.co.uk
Deks UK
West End Trading Estate,
Blackfriars Road,
Nailsea, Bristol,
BS48 4DJ,
T: 01275 858 866
F: 01275 855 887
www.deks.co.uk
Exodraft
Unit 3 Lancaster Court Coronation Road,
Cressex Business Park,
High Wycombe,
Buckinghamshire,
HP12 3TD,
T: 01494 465166
F: 01494 465163
www.exodraft.co.uk
H. Docherty
15/16 Colthrop Business Park,
Thatcham,
Berkshire,
RG19 4NB,
T: 01635 292 400
F: 01635 201 737
E: sales@docherty.co.uk
www.docherty.co.uk
Hanson Red Bank
Atherstone Road,
Measham,
Swadlincote,
Derbyshire,
DE12 7EL,
T: 01530 270333
F: 01530 273667
www.redbankmfg.co.uk
JRF Chimney Specialists
& Heating Distributors
50 Nasmyth Road,
Southfield Industrial Estate,
Glenrothes, Fife,
KY6 2SD,
T: 01592 771199
F: 01592 771135
www.jrf-chimney-spec.co.uk
www.bfcma.co.uk
Table of contents
Popular Wood Stove manuals by other brands

RAIS
RAIS attika NEXO 100 GAS installation guide

WoodPro
WoodPro WS-TS-1500 owner's manual

Contura
Contura C 586W installation instructions

Palazzetti
Palazzetti EVA GENERAL INFORMATION - WARNINGS - INSTALLATION - MAINTENANCE

Lopi
Lopi 1250 Republic owner's manual

Panadero
Panadero CAPRI 3V Usage and maintenance instructions